1.
Int J Radiat Biol ; 97(7): 888-905, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33970757

RESUMO

PURPOSE: In case of a mass-casualty radiological event, there would be a need for networking to overcome surge limitations and to quickly obtain homogeneous results (reported aberration frequencies or estimated doses) among biodosimetry laboratories. These results must be consistent within such network. Inter-laboratory comparisons (ILCs) are widely accepted to achieve this homogeneity. At the European level, a great effort has been made to harmonize biological dosimetry laboratories, notably during the MULTIBIODOSE and RENEB projects. In order to continue the harmonization efforts, the RENEB consortium launched this intercomparison which is larger than the RENEB network, as it involves 38 laboratories from 21 countries. In this ILC all steps of the process were monitored, from blood shipment to dose estimation. This exercise also aimed to evaluate the statistical tools used to compare laboratory performance. MATERIALS AND METHODS: Blood samples were irradiated at three different doses, 1.8, 0.4 and 0 Gy (samples A, C and B) with 4-MV X-rays at 0.5 Gy min-1, and sent to the participant laboratories. Each laboratory was requested to blindly analyze 500 cells per sample and to report the observed frequency of dicentric chromosomes per metaphase and the corresponding estimated dose. RESULTS: This ILC demonstrates that blood samples can be successfully distributed among laboratories worldwide to perform biological dosimetry in case of a mass casualty event. Having achieved a substantial harmonization in multiple areas among the RENEB laboratories issues were identified with the available statistical tools, which are not capable to advantageously exploit the richness of results of a large ILCs. Even though Z- and U-tests are accepted methods for biodosimetry ILCs, setting the number of analyzed metaphases to 500 and establishing a tests' common threshold for all studied doses is inappropriate for evaluating laboratory performance. Another problem highlighted by this ILC is the issue of the dose-effect curve diversity. It clearly appears that, despite the initial advantage of including the scoring specificities of each laboratory, the lack of defined criteria for assessing the robustness of each laboratory's curve is a disadvantage for the 'one curve per laboratory' model. CONCLUSIONS: Based on our study, it seems relevant to develop tools better adapted to the collection and processing of results produced by the participant laboratories. We are confident that, after an initial harmonization phase reached by the RENEB laboratories, a new step toward a better optimization of the laboratory networks in biological dosimetry and associated ILC is on the way.


Assuntos
Laboratórios , Radiometria , Aberrações Cromossômicas/efeitos da radiação , Humanos , Exposição à Radiação , Reprodutibilidade dos Testes
2.
Artigo em Inglês | MEDLINE | ID: mdl-33551098

RESUMO

Five occupational workers in an industrial sterilization unit at Stamboliyski in Bulgaria were accidentally exposed to a very high specific activity of Cobalt-60 source on June 14, 2011. Initial cytogenetic analysis performed on days 2 and 7 after radiation exposure revealed the whole body absorbed radiation doses of 5.32 Gy for patient 1, 3.40 Gy for patient 2, 2.50 Gy for patient 3, 1.91 Gy for patient 4 and 1.24 Gy for patient 5 [1]. Here, a retrospective multicolor FISH analysis was performed on three patients (patients 1, 2 and 3) using the blood samples collected over a period of 4 years from 2012 through 2015. In all the three patients, cells with stable chromosome aberrations (simple and complex chromosome translocations) were 3-4 folds more than cells with unstable chromosome aberrations (dicentric, rings and excess acentric chromosome fragments). In corroboration with the results reported in the literature, we observed that the time dependent decline of dicentrics, rings and excess acentric fragments occurred much more rapidly than chromosome translocations in the blood samples of the three victims. Further, inter-individual variation in the decline of radiation induced chromosome aberrations was also noticed among the three victims. The reason for the increased persistence of balanced chromosome translocations is not entirely clear but may be attributed to certain subsets of long-lived T-lymphocytes. The retrospective cytogenetic follow up studies on radiation-exposed victims may be useful for determining the extent of genomic/chromosomal instability in the hematopoietic system.


Assuntos
Aberrações Cromossômicas/efeitos da radiação , Análise Citogenética/métodos , Raios gama/efeitos adversos , Linfócitos/patologia , Exposição à Radiação/efeitos adversos , Liberação Nociva de Radioativos/estatística & dados numéricos , Adulto , Idoso , Feminino , Humanos , Linfócitos/efeitos da radiação , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos
3.
Int J Radiat Biol ; 93(1): 118-126, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27735728

RESUMO

PURPOSE: In the frame of the QA program of RENEB, an inter-laboratory comparison (ILC) of calibration sources used in biological dosimetry was achieved to investigate the influence of calibration practices and protocols on the results of the dose estimation performance as a first step to harmonization and standardization of dosimetry and irradiation practices in the European biological dosimetry network. MATERIALS AND METHODS: Delivered doses by irradiation facilities used by RENEB partners were determined with EPR/alanine dosimetry system. Dosimeters were irradiated in the same conditions as blood samples. A short survey was also performed to collect the information needed for the data analysis and evaluate the diversity of practices. RESULTS: For most of partners the deviation of delivered dose from the targeted dose remains below 10%. Deviations larger than 10% were observed for five facilities out of 21. Origins of the largest discrepancies were identified. Correction actions were evaluated as satisfactory. The re-evaluation of some ILC results for the fluorescence in situ hybridization (FISH) and premature chromosome condensation (PCC) assays has been performed leading to an improvement of the overall performances. CONCLUSIONS: This work has shown the importance of dosimetry in radiobiology studies and the needs of harmonization, standardization in irradiation and dosimetry practices and educational training for biologists using ionizing radiation.


Assuntos
Calibragem/normas , Análise Citogenética/normas , Laboratórios/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde/normas , Exposição à Radiação/análise , Monitoramento de Radiação/normas , Análise Citogenética/estatística & dados numéricos , Europa (Continente) , Humanos , Laboratórios/normas , Guias de Prática Clínica como Assunto , Doses de Radiação , Monitoramento de Radiação/estatística & dados numéricos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Int J Radiat Biol ; 93(1): 136-141, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27557790

RESUMO

PURPOSE: To identify and assess, among the participants in the RENEB (Realizing the European Network of Biodosimetry) project, the emergency preparedness, response capabilities and resources that can be deployed in the event of a radiological or nuclear accident/incident affecting a large number of individuals. These capabilities include available biodosimetry techniques, infrastructure, human resources (existing trained staff), financial and organizational resources (including the role of national contact points and their articulation with other stakeholders in emergency response) as well as robust quality control/assurance systems. MATERIALS AND METHODS: A survey was prepared and sent to the RENEB partners in order to acquire information about the existing, operational techniques and infrastructure in the laboratories of the different RENEB countries and to assess the capacity of response in the event of radiological or nuclear accident involving mass casualties. The survey focused on several main areas: laboratory's general information, country and staff involved in biological and physical dosimetry; retrospective assays used, the number of assays available per laboratory and other information related to biodosimetry and emergency preparedness. Following technical intercomparisons amongst RENEB members, an update of the survey was performed one year later concerning the staff and the available assays. CONCLUSIONS: The analysis of RENEB questionnaires allowed a detailed assessment of existing capacity of the RENEB network to respond to nuclear and radiological emergencies. This highlighted the key importance of international cooperation in order to guarantee an effective and timely response in the event of radiological or nuclear accidents involving a considerable number of casualties. The deployment of the scientific and technical capabilities existing within the RENEB network members seems mandatory, to help other countries with less or no capacity for biological or physical dosimetry, or countries overwhelmed in case of a radiological or nuclear accident involving a large number of individuals.


Assuntos
Pesquisa Biomédica/organização & administração , Planejamento em Desastres/organização & administração , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Liberação Nociva de Radioativos , Gestão da Segurança/organização & administração , Europa (Continente) , Modelos Organizacionais , Radiobiologia/organização & administração
5.
Int J Radiat Biol ; 93(1): 75-80, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27559844

RESUMO

PURPOSE: The RENEB accident exercise was carried out in order to train the RENEB participants in coordinating and managing potentially large data sets that would be generated in case of a major radiological event. MATERIALS AND METHODS: Each participant was offered the possibility to activate the network by sending an alerting email about a simulated radiation emergency. The same participant had to collect, compile and report capacity, triage categorization and exposure scenario results obtained from all other participants. The exercise was performed over 27 weeks and involved the network consisting of 28 institutes: 21 RENEB members, four candidates and three non-RENEB partners. RESULTS: The duration of a single exercise never exceeded 10 days, while the response from the assisting laboratories never came later than within half a day. During each week of the exercise, around 4500 samples were reported by all service laboratories (SL) to be examined and 54 scenarios were coherently estimated by all laboratories (the standard deviation from the mean of all SL answers for a given scenario category and a set of data was not larger than 3 patient codes). CONCLUSIONS: Each participant received training in both the role of a reference laboratory (activating the network) and of a service laboratory (responding to an activation request). The procedures in the case of radiological event were successfully established and tested.


Assuntos
Planejamento em Desastres/organização & administração , Monitoramento de Radiação/métodos , Liberação Nociva de Radioativos , Radiobiologia/educação , Gestão da Segurança/organização & administração , Triagem/organização & administração , Europa (Continente)
6.
Int J Radiat Biol ; 93(1): 36-47, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27673504

RESUMO

PURPOSE: In the framework of the 'Realizing the European Network of Biodosimetry' (RENEB) project, two intercomparison exercises were conducted to assess the suitability of an optimized version of the cytokinesis-block micronucleus assay, and to evaluate the capacity of a large laboratory network performing biodosimetry for radiation emergency triages. Twelve European institutions participated in the first exercise, and four non-RENEB labs were added in the second one. MATERIALS AND METHODS: Irradiated blood samples were shipped to participating labs, whose task was to culture these samples and provide a blind dose estimate. Micronucleus analysis was performed by automated, semi-automated and manual procedures. RESULTS: The dose estimates provided by network laboratories were in good agreement with true administered doses. The most accurate estimates were reported for low dose points (≤ 0.94 Gy). For higher dose points (≥ 2.7 Gy) a larger variation in estimates was observed, though in the second exercise the number of acceptable estimates increased satisfactorily. Higher accuracy was achieved with the semi-automated method. CONCLUSION: The results of the two exercises performed by our network demonstrate that the micronucleus assay is a useful tool for large-scale radiation emergencies, and can be successfully implemented within a large network of laboratories.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Testes para Micronúcleos/métodos , Garantia da Qualidade dos Cuidados de Saúde , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Bioensaio/normas , Europa (Continente) , Humanos , Linfócitos/efeitos da radiação , Monitoramento de Radiação/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Int J Radiat Biol ; 93(1): 110-117, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27547893

RESUMO

PURPOSE: To establish a training data set of digital images and to investigate the scoring criteria and dose assessment of the dicentric assay within the European network of biodosimetry (RENEB), a web based scoring inter-comparison was undertaken by 17 RENEB partners. MATERIALS AND METHODS: Two sets of 50 high resolution images were uploaded onto the RENEB website. One set included metaphases after a moderate exposure (1.3 Gy) and the other set consisted of metaphases after a high dose exposure (3.5 Gy). The laboratories used their own calibration curves for estimating doses based on observed aberration frequencies. RESULTS: The dose estimations and 95% confidence limits were compared to the actual doses and the corresponding z-values were satisfactory for the majority; only the dose estimations from two laboratories were too low or too high. The coefficients of variation were 17.6% for the moderate and 11.2% for the high dose. Metaphases with controversial results could be identified for training purposes. CONCLUSIONS: Overall, the web based scoring of the two galleries by the 17 laboratories produced very good results. Application of web based scoring for the dicentric assay may therefore be a relevant strategy for an operational biodosimetry assistance network.


Assuntos
Bioensaio/métodos , Análise Citogenética/métodos , Internet/organização & administração , Linfócitos/efeitos da radiação , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Europa (Continente) , Humanos , Laboratórios/estatística & dados numéricos , Linfócitos/citologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Int J Radiat Biol ; 93(1): 2-14, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27707245

RESUMO

PURPOSE: A European network was initiated in 2012 by 23 partners from 16 European countries with the aim to significantly increase individualized dose reconstruction in case of large-scale radiological emergency scenarios. RESULTS: The network was built on three complementary pillars: (1) an operational basis with seven biological and physical dosimetric assays in ready-to-use mode, (2) a basis for education, training and quality assurance, and (3) a basis for further network development regarding new techniques and members. Techniques for individual dose estimation based on biological samples and/or inert personalized devices as mobile phones or smart phones were optimized to support rapid categorization of many potential victims according to the received dose to the blood or personal devices. Communication and cross-border collaboration were also standardized. To assure long-term sustainability of the network, cooperation with national and international emergency preparedness organizations was initiated and links to radiation protection and research platforms have been developed. A legal framework, based on a Memorandum of Understanding, was established and signed by 27 organizations by the end of 2015. CONCLUSIONS: RENEB is a European Network of biological and physical-retrospective dosimetry, with the capacity and capability to perform large-scale rapid individualized dose estimation. Specialized to handle large numbers of samples, RENEB is able to contribute to radiological emergency preparedness and wider large-scale research projects.


Assuntos
Bioensaio/métodos , Planejamento em Desastres/organização & administração , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Gestão da Segurança/organização & administração , Emergências , Europa (Continente) , Humanos , Objetivos Organizacionais , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Liberação Nociva de Radioativos/prevenção & controle
9.
Int J Radiat Biol ; 93(1): 20-29, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27766931

RESUMO

PURPOSE: Two quality controlled inter-laboratory exercises were organized within the EU project 'Realizing the European Network of Biodosimetry (RENEB)' to further optimize the dicentric chromosome assay (DCA) and to identify needs for training and harmonization activities within the RENEB network. MATERIALS AND METHODS: The general study design included blood shipment, sample processing, analysis of chromosome aberrations and radiation dose assessment. After manual scoring of dicentric chromosomes in different cell numbers dose estimations and corresponding 95% confidence intervals were submitted by the participants. RESULTS: The shipment of blood samples to the partners in the European Community (EU) were performed successfully. Outside the EU unacceptable delays occurred. The results of the dose estimation demonstrate a very successful classification of the blood samples in medically relevant groups. In comparison to the 1st exercise the 2nd intercomparison showed an improvement in the accuracy of dose estimations especially for the high dose point. CONCLUSIONS: In case of a large-scale radiological incident, the pooling of ressources by networks can enhance the rapid classification of individuals in medically relevant treatment groups based on the DCA. The performance of the RENEB network as a whole has clearly benefited from harmonization processes and specific training activities for the network partners.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Testes para Micronúcleos/métodos , Garantia da Qualidade dos Cuidados de Saúde , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Bioensaio/normas , Europa (Continente) , Humanos , Linfócitos/efeitos da radiação , Monitoramento de Radiação/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Int J Radiat Biol ; 93(1): 99-109, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27437830

RESUMO

PURPOSE: RENEB, 'Realising the European Network of Biodosimetry and Physical Retrospective Dosimetry,' is a network for research and emergency response mutual assistance in biodosimetry within the EU. Within this extremely active network, a number of new dosimetry methods have recently been proposed or developed. There is a requirement to test and/or validate these candidate techniques and inter-comparison exercises are a well-established method for such validation. MATERIALS AND METHODS: The authors present details of inter-comparisons of four such new methods: dicentric chromosome analysis including telomere and centromere staining; the gene expression assay carried out in whole blood; Raman spectroscopy on blood lymphocytes, and detection of radiation-induced thermoluminescent signals in glass screens taken from mobile phones. RESULTS: In general the results show good agreement between the laboratories and methods within the expected levels of uncertainty, and thus demonstrate that there is a lot of potential for each of the candidate techniques. CONCLUSIONS: Further work is required before the new methods can be included within the suite of reliable dosimetry methods for use by RENEB partners and others in routine and emergency response scenarios.


Assuntos
Bioensaio/métodos , Planejamento em Desastres/métodos , Laboratórios , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Gestão da Segurança/métodos , União Europeia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Integração de Sistemas
11.
Int J Radiat Biol ; 93(1): 48-57, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27813725

RESUMO

PURPOSE: Dose assessment intercomparisons within the RENEB network were performed for triage biodosimetry analyzing G0-lymphocyte PCC for harmonization, standardization and optimization of the PCC assay. MATERIALS AND METHODS: Comparative analysis among different partners for dose assessment included shipment of PCC-slides and captured images to construct dose-response curves for up to 6 Gy γ-rays. Accident simulation exercises were performed to assess the suitability of the PCC assay by detecting speed of analysis and minimum number of cells required for categorization of potentially exposed individuals. RESULTS: Calibration data based on Giemsa-stained fragments in excess of 46 PCC were obtained by different partners using galleries of PCC images for each dose-point. Mean values derived from all scores yielded a linear dose-response with approximately 4 excess-fragments/cell/Gy. To unify scoring criteria, exercises were carried out using coded PCC-slides and/or coded irradiated blood samples. Analysis of samples received 24 h post-exposure was successfully performed using Giemsa staining (1 excess-fragment/cell/Gy) or centromere/telomere FISH-staining for dicentrics. CONCLUSIONS: Dose assessments by RENEB partners using appropriate calibration curves were mostly in good agreement. The PCC assay is quick and reliable for whole- or partial-body triage biodosimetry by scoring excess-fragments or dicentrics in G0-lymphocytes. Particularly, analysis of Giemsa-stained excess PCC-fragments is simple, inexpensive and its automation could increase throughput and scoring objectivity of the PCC assay.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Testes para Micronúcleos/métodos , Garantia da Qualidade dos Cuidados de Saúde , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Bioensaio/normas , Europa (Continente) , Humanos , Linfócitos/citologia , Linfócitos/efeitos da radiação , Monitoramento de Radiação/normas , Reprodutibilidade dos Testes , Fase de Repouso do Ciclo Celular/genética , Fase de Repouso do Ciclo Celular/efeitos da radiação , Sensibilidade e Especificidade
12.
Mutat Res ; 749(1-2): 3-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23994714

RESUMO

Multiple sclerosis is a clinically heterogeneous autoimmune disease leading to severe neurological disability. Although during the last years many disease-modifying agents as treatment options for multiple sclerosis have been made available, their mechanisms of action are still not fully determined. In the present study radiosensitivity in lymphocytes of patients with relapsing-remitting multiple sclerosis, secondary progressive multiple sclerosis and healthy controls was investigated. Whole blood cultures from multiple sclerosis patients and healthy controls were used to analyze the spontaneous and radiation-induced micronuclei in binucleated lymphocytes. A subgroup of patients with relapsing-remitting multiple sclerosis was treated with immunomodulatory agents, interferon ß or glatiramer acetate. The secondary progressive multiple sclerosis patients group was not receiving any treatment. Our results reveal that the basal DNA damage was not different between relapsing-remitting and secondary progressive multiple sclerosis patients, and healthy controls. No differences between gamma-irradiation induced micronuclei frequencies in binucleated cells from relapsing-remitting and secondary progressive multiple sclerosis patients, and healthy controls were found either. Nevertheless, when we compared the radiation induced DNA damage in binucleated cells from healthy individuals with the whole group of patients, a reduction in the frequency of micronuclei was obtained in the patients group. Induced micronuclei yield was significantly lower in the irradiated samples from treated relapsing-remitting multiple sclerosis patients than in healthy controls and relapsing-remitting not treated patients. Intrinsic sensitivity of lymphocytes subpopulations to the apoptotic effect of immunomodulatory treatment could be responsible for this result.


Assuntos
Cromossomos Humanos/efeitos da radiação , Esclerose Múltipla/fisiopatologia , Tolerância a Radiação/genética , Adolescente , Adulto , Estudos de Casos e Controles , Células Cultivadas , Feminino , Acetato de Glatiramer , Humanos , Imunossupressores/uso terapêutico , Interferon beta/uso terapêutico , Leucócitos Mononucleares/efeitos dos fármacos , Leucócitos Mononucleares/patologia , Leucócitos Mononucleares/efeitos da radiação , Masculino , Micronúcleos com Defeito Cromossômico/efeitos dos fármacos , Micronúcleos com Defeito Cromossômico/efeitos da radiação , Micronúcleos com Defeito Cromossômico/estatística & dados numéricos , Testes para Micronúcleos , Pessoa de Meia-Idade , Esclerose Múltipla/sangue , Esclerose Múltipla/tratamento farmacológico , Esclerose Múltipla/genética , Peptídeos/uso terapêutico , Adulto Jovem
13.
J Radiat Res ; 54(5): 832-9, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23536543

RESUMO

The aim of this study was to evaluate the genotoxic effects of ionizing radiation in vivo in exposed Bulgarian nuclear power plant workers by using classical cytogenetic and molecular cytogenetic analyses of peripheral lymphocytes. Chromosome analysis using fluorescence in situ hybrydization (FISH) and Giemsa techniques was undertaken on 63 workers and 45 administrative staff controls from the Bulgarian Nuclear Power Plant. Using the Giemsa method, the frequencies of cells studied with chromosome aberrations, dicentrics plus rings and chromosome fragments in the radiation workers were significantly higher compared with the control group (P = 0.044, P = 0.014, and P = 0.033, respectively). A significant association between frequencies of dicentrics plus rings and accumulated doses was registered (P < 0.01). In the present study, a FISH cocktail of whole chromosome paints for chromosomes 1, 4 and 11 was used. A significant association between frequency of translocations and accumulated doses was also observed (P < 0.001). Within the control group, a correlation was found between age and the spontaneous frequency of translocations. No correlation was found between smoking status and frequency of translocations. When compared with the control group, workers with accumulated doses up to 100 mSv showed no increase in genome translocation frequency, whereas workers with accumulated doses from 101 to 200 mSv showed a statistically significant doubling of genome translocation frequency (P = 0.009). Thus, in cases of chronic exposure and for purposes of retrospective dosimetry, the genome frequency of translocations is a more useful marker for evaluation of genotoxic effects than dicentric frequency.


Assuntos
Bioensaio/estatística & dados numéricos , Aberrações Cromossômicas/efeitos da radiação , Aberrações Cromossômicas/estatística & dados numéricos , Hibridização in Situ Fluorescente/estatística & dados numéricos , Centrais Nucleares/estatística & dados numéricos , Lesões por Radiação/epidemiologia , Adolescente , Adulto , Idoso , Consumo de Bebidas Alcoólicas/epidemiologia , Corantes Azur , Bioensaio/métodos , Bulgária/epidemiologia , Comorbidade , Análise Citogenética/estatística & dados numéricos , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional , Prevalência , Doses de Radiação , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade , Fumar/epidemiologia , Adulto Jovem
14.
Mutat Res ; 728(3): 88-97, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21763453

RESUMO

The human buccal micronucleus cytome assay (BMCyt) is one of the most widely used techniques to measure genetic damage in human population studies. Reducing protocol variability, assessing the role of confounders, and estimating a range of reference values are research priorities that will be addressed by the HUMN(XL) collaborative study. The HUMN(XL) project evaluates the impact of host factors, occupation, life-style, disease status, and protocol features on the occurrence of MN in exfoliated buccal cells. In addition, the study will provide a range of reference values for all cytome endpoints. A database of 5424 subjects with buccal MN values obtained from 30 laboratories worldwide was compiled and analyzed to investigate the influence of several conditions affecting MN frequency. Random effects models were mostly used to investigate MN predictors. The estimated spontaneous MN frequency was 0.74‰ (95% CI 0.52-1.05). Only staining among technical features influenced MN frequency, with an abnormal increase for non-DNA-specific stains. No effect of gender was evident, while the trend for age was highly significant (p<0.001). Most occupational exposures and a diagnosis of cancer significantly increased MN and other endpoints frequencies. MN frequency increased in heavy smoking (≥40cig/day, FR=1.37; 95% CI 1.03-.82) and decreased with daily fruit consumption (FR=0.68; 95% CI 0.50-0.91). The results of the HUMN(XL) project identified priorities for validation studies, increased the basic knowledge of the assay, and contributed to the creation of a laboratory network which in perspective may allow the evaluation of disease risk associated with MN frequency.


Assuntos
Testes para Micronúcleos/métodos , Mucosa Bucal/citologia , Fatores Etários , Bochecha , Nível de Saúde , Humanos , Estilo de Vida , Exposição Ocupacional , Padrões de Referência , Fatores Sexuais
15.
Rep Pract Oncol Radiother ; 17(1): 24-31, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-24376993

RESUMO

BACKGROUND: Pelvic organs morbidity after irradiation of cancer patients remains a major problem although new technologies have been developed and implemented. A relatively simple and suitable method for routine clinical practice is needed for preliminary assessment of normal tissue intrinsic radiosensitivity. The micronucleus test (MNT) determines the frequency of the radiation induced micronuclei (MN) in peripheral blood lymphocytes, which could serve as an indicator of intrinsic cell radiosensitivity. AIM: To investigate a possible use of the micronucleus test (MNT) for acute radiation morbidity prediction in gynecological cancer patients. MATERIALS AND METHODS: Forty gynecological cancer patients received 50 Gy conventional external pelvic irradiation after radical surgery. A four-field "box" technique was applied with 2D planning. The control group included 10 healthy females. Acute normal tissue reactions were graded according to NCI CTCAE v.3.0. From all reaction scores, the highest score named "summarized clinical radiosensitivity" was selected for a statistical analysis. MNT was performed before and after in vitro irradiation with 1.5 Gy. The mean radiation induced frequency of micronuclei per 1000 binucleated cells (MN/1000) and lymphocytes containing micronuclei per 1000 binucleated cells (cells with MN/1000) were evaluated for both patients and controls. AN ARBITRARY CUT OFF VALUE WAS CREATED TO PICK UP A RADIOSENSITIVE INDIVIDUAL: the mean value of spontaneous frequency of cells with MN/1000 ± 2SD, found in the control group. RESULTS: Both mean spontaneous frequency of cells with MN/1000 and MN/1000 were registered to be significantly higher in cancer patients compared to the control group (t = 2.46, p = 0.02 and t = 2.51, p = 0.02). No statistical difference was registered when comparing radiation induced MN frequencies between those groups. Eighty percent (32) of patients developed grade 2 summarized clinical radiosensitivity, with great variations in MNT parameters. Only three patients with grade 2 "summarized clinical radiosensitivity" had values of cells with MN/1000 above the chosen radiosensitivity threshold. CONCLUSION: The present study was not able to confirm in vitro MNT applicability for radiosensitivity prediction in pelvic irradiation.

16.
Health Phys ; 98(2): 252-7, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20065690

RESUMO

This paper details the construction of a 137Cs gamma calibration curve that has been established for dicentric assay and the testing and validation of the curve through biological dosimetry in three situations of suspected workplace overexposure that arose accidentally or through negligence or lack of appropriate safety measures. The three situations were: (1) suspected 137Cs contamination in a factory air supply; (2) suspected exposure to an industrial 192Ir source; and (3) accidental exposure of construction workers to radiation from a 60Co radiotherapy source in a hospital medical physics department. From a total of 24 potentially-exposed subjects, only one worker was found to have a statistically significant dose (0.16 Gy, 95% confidence intervals 0.02-0.43 Gy). In all other cases, the main function of the biological dosimetry was to reassure the subjects that any dose received was low.


Assuntos
Bioensaio/métodos , Carga Corporal (Radioterapia) , Aberrações Cromossômicas/efeitos da radiação , Exposição Ambiental/análise , Testes para Micronúcleos/métodos , Liberação Nociva de Radioativos , Radiometria/métodos , Bulgária , Humanos , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Hell J Nucl Med ; 8(1): 54-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15886755

RESUMO

Cytokinesis-blocked micronucleus assay (MNT) was applied in the peripheral blood lymphocytes of patients undergoing radioiodine-131 ((131)I) therapy for differentiated thyroid carcinoma (DTC) after thyroidectomy to assess the genotoxic risk of this therapy. The amount of administered (131)I activity varied from 3,330 to 4,030 MBq. Blood samples were taken immediately before (131)I administration and one month later, along with routine blood tests. Twenty-six patients underwent radioiodine ablation (RIA) or radioiodine therapy (RIT) after radical thyroidectomy. The aim of this therapy was to ablate residual thyroid tissue, to treat lymph node metastases and/or distant lung metastases. The amount of orally administered activity of (131)I ranged between 3,330 and 4,030 MBq according to the kind of therapy (RIA or RIT). In five patients the cytogenetic analysis was performed immediately before and one month after the second therapy which was given to them 6 months to 1 year after the first. Three patients were male and 23 female. The age of the patients ranged between 23 and 76 years (mean age: 48.6 years). Results show that after radioiodine therapy there is a significant increase in the frequency of micronuclei. Comparing the average frequency of micronuclei in the patients studied before and after (131)I, a more than doubling increase was found. Mean values +/- SD of the patients before and after (131)I therapy were 10.72 per thousand +/- 5.84 per thousandand 25.28 per thousand +/- 12.6 per thousand respectively. These findings indicate a genotoxic activity of (131)I therapy estimated after a period of one month.


Assuntos
Quebra Cromossômica , Radioisótopos do Iodo/efeitos adversos , Radioisótopos do Iodo/uso terapêutico , Linfócitos/efeitos da radiação , Lesões por Radiação/diagnóstico , Radiometria/métodos , Medição de Risco/métodos , Neoplasias da Glândula Tireoide/radioterapia , Adulto , Idoso , Carga Corporal (Radioterapia) , Cromossomos Humanos/efeitos da radiação , Citocinese/efeitos da radiação , Feminino , Humanos , Masculino , Testes para Micronúcleos , Pessoa de Meia-Idade , Lesões por Radiação/etiologia , Proteção Radiológica/métodos , Compostos Radiofarmacêuticos/efeitos adversos , Compostos Radiofarmacêuticos/uso terapêutico , Dosagem Radioterapêutica , Fatores de Risco
18.
Radiat Res ; 160(6): 684-90, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14640795

RESUMO

Nuclear power plant workers are exposed to ionizing radiation at relatively low doses and for prolonged periods of time. To investigate the extent of genetic damage in these workers, a group of 133 nuclear power plant workers and 39 healthy controls were compared using the cytokinesis-block micronucleus assay. The frequency of micronuclei was significantly increased in peripheral lymphocytes of nuclear power plant workers (20.5 +/- 9.7% compared to 13.7 +/- 5.9%). A significant dose-response relationship was observed between micronucleus (MN) frequency and both the accumulated dose and the duration of employment (P < 0.01 for both variables after adjusting for age, gender and cigarette smoking) with an evident leveling off for exposures over 200 mSv. Accumulated dose and duration of employment were significantly correlated but exerted independent effects on MN frequency. For non-occupational parameters, age was significantly associated with the frequency of micronuclei, while gender was not. Smoking habit showed no overall effect, whereas increased chromosome damage was evident in smokers of more than 20 cigarettes per day. In conclusion, a dose-related association between MN frequency and exposure to ionizing radiation was evident in nuclear power plant workers, encouraging the application of the cytokinesis-block micronucleus assay in biomonitoring studies of human populations with prolonged exposure to ionizing radiation.


Assuntos
Linfócitos/efeitos da radiação , Micronúcleos com Defeito Cromossômico/efeitos da radiação , Exposição Ocupacional , Centrais Elétricas , Adulto , Relação Dose-Resposta à Radiação , Feminino , Humanos , Linfócitos/ultraestrutura , Masculino , Pessoa de Meia-Idade
19.
Mutat Res ; 534(1-2): 45-64, 2003 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-12504754

RESUMO

One of the objectives of the HUman MicroNucleus (HUMN) project is to identify the methodological variables that have an important impact on micronucleus (MN) or micronucleated (MNed) cell frequencies measured in human lymphocytes using the cytokinesis-block micronucleus assay. In a previous study we had shown that the scoring criteria used were likely to be an important variable. To determine the extent of residual variation when laboratories scored cells from the same cultures using the same set of standard scoring criteria, an inter-laboratory slide-scoring exercise was performed among 34 laboratories from 21 countries with a total of 51 slide scorers involved. The results of this study show that even under these optimized conditions there is a great variation in the MN frequency or MNed cell frequency obtained by individual laboratories and scorers. All laboratories ranked correctly the MNed cell frequency in cells from cultures that were unirradiated, or exposed to 1 or 2Gy of gamma rays. The study also estimated that the intra-scorer median coefficient of variation for duplicate MNed cell frequency scores is 29% for unexposed cultures and 14 and 11% for cells exposed to 1 and 2Gy, respectively. These values can be used as a standard for quality or acceptability of data in future studies. Using a Poisson regression model it was estimated that radiation dose explained 67% of the variance, while staining method, cell sample, laboratory, and covariance explained 0.6, 0.3, 6.5, and 25.6% of the variance, respectively, leaving only 3.1% of the variance unexplained. As part of this exercise, nucleoplasmic bridges were also estimated by the laboratories; however, inexperience in the use of this biomarker of chromosome rearrangement was reflected in the much greater heterogeneity in the data and the unexplained variation estimated by the Poisson model. The results of these studies indicate clearly that even after standardizing culture and scoring conditions it will be necessary to calibrate scorers and laboratories if MN, MNed cell and nucleoplasmic bridge frequencies are to be reliably compared among laboratories and among populations.


Assuntos
Estruturas do Núcleo Celular/genética , Linfócitos/fisiologia , Testes para Micronúcleos/normas , Variações Dependentes do Observador , Análise de Variância , Humanos , Cooperação Internacional , Laboratórios , Linfócitos/efeitos da radiação , Masculino , Distribuição de Poisson , Padrões de Referência
20.
Mutat Res ; 514(1-2): 29-38, 2002 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-11815242

RESUMO

The aim of the present study was to evaluate the genotoxic effects of hexavalent chromium (Cr(VI)) in vivo in exposed Bulgarian chromium platers by using classical cytogenetic and molecular cytogenetic analyses of peripheral lymphocytes and exfoliated buccal cells. No significant difference was observed between the exposed workers and the controls with regard to the frequency of cells with chromosome aberrations (CAs) using conventional Giemsa staining and in the frequency of sister chromatid exchanges (SCEs). However, there was a significant increase in the number of cells with micronuclei (MN) in peripheral lymphocytes from chromium exposed workers as compared to the controls. In the buccal cells from these workers, this increase was even more pronounced. Cytosine arabinoside (AraC), an inhibitor of DNA synthesis and repair, was found to significantly increase the levels of MN in vitro in the lymphocytes of both groups. The increase was more expressed in the lymphocytes of chromium exposed workers. Both centromere positive (C(+)) as well as centromere negative (C(-)) MN were observed by the fluorescence in situ hybridization (FISH) technique in both of the cell types studied. No difference between C(+) and C(-) MN frequencies was found in the lymphocytes as well as in the buccal cells. Thus, Cr(VI) appears to have both clastogenic as well as aneugenic effects in humans.


Assuntos
Carcinógenos Ambientais/toxicidade , Cromo/toxicidade , Aberrações Cromossômicas , Exposição Ocupacional , Troca de Cromátide Irmã , Adulto , Antimetabólitos Antineoplásicos/farmacologia , Bulgária , Células Cultivadas , Estudos de Coortes , Citarabina/farmacologia , Análise Citogenética , Feminino , Humanos , Exposição por Inalação , Linfócitos/efeitos dos fármacos , Linfócitos/fisiologia , Masculino , Micronúcleos com Defeito Cromossômico/metabolismo , Testes para Micronúcleos , Pessoa de Meia-Idade , Mucosa Bucal/citologia , Mucosa Bucal/efeitos dos fármacos , Mucosa Bucal/metabolismo , Testes de Mutagenicidade
SELEÇÃO DE REFERÊNCIAS