1.
Adv Mater ; 35(26): e2208719, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36932736

RESUMO

Optical biosensors based on plasmonic sensing schemes combine high sensitivity and selectivity with label-free detection. However, the use of bulky optical components is still hampering the possibility of obtaining miniaturized systems required for analysis in real settings. Here, a fully miniaturized optical biosensor prototype based on plasmonic detection is demonstrated, which enables fast and multiplex sensing of analytes with high- and low molecular weight (80 000 and 582 Da) as quality and safety parameters for milk: a protein (lactoferrin) and an antibiotic (streptomycin). The optical sensor is based on the smart integration of: i) miniaturized organic optoelectronic devices used as light-emitting and light-sensing elements and ii) a functionalized nanostructured plasmonic grating for highly sensitive and specific localized surface plasmon resonance (SPR) detection. The sensor provides quantitative and linear response reaching a limit of detection of 10-4 refractive index units once it is calibrated by standard solutions. Analyte-specific and rapid (15 min long) immunoassay-based detection is demonstrated for both targets. By using a custom algorithm based on principal-component analysis, a linear dose-response curve is constructed which correlates with a limit of detection (LOD) as low as 3.7 µg mL-1 for lactoferrin, thus assessing that the miniaturized optical biosensor is well-aligned with the chosen reference benchtop SPR method.


Assuntos
Técnicas Biossensoriais , Lactoferrina , Peso Molecular , Técnicas Biossensoriais/métodos , Ressonância de Plasmônio de Superfície , Limite de Detecção
2.
Stud Health Technol Inform ; 270: 751-755, 2020 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-32570483

RESUMO

Classical approaches for measuring high-quality ECG require the use of gel electrodes and individually shielded cables, which limit patient comfort, especially in long-term use. We recently introduced a novel sensing architecture-so-called cooperative sensors-that allow the use of active dry electrodes connected by two unshielded wires. The aim of this work is to qualitatively evaluate an ECG recorded with a dry-electrode cooperative-sensor system. To that end, preliminary observations were made on three healthy subjects. The ECGs were concurrently recorded with cooperative sensors and a gold-standard 12-lead ECG device during a stress test on a stationary bicycle. First experimental measurements demonstrated the reliability of the approach for a wearable 12-lead ECG monitoring system tested in real settings.


Assuntos
Eletrocardiografia , Eletrodos , Desenho de Equipamento , Teste de Esforço , Humanos , Reprodutibilidade dos Testes