Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38837348

RESUMO

OBJECTIVES: To assess the accuracy of a deep learning-based algorithm for fully automated detection of thoracic aortic calcifications in chest computed tomography (CT) with a focus on the aortic clamping zone. METHODS: We retrospectively included 100 chest CT scans from 91 patients who were examined on second- or third-generation dual-source scanners. Subsamples comprised 47 scans with an electrocardiogram-gated aortic angiography and 53 unenhanced scans. A deep learning model performed aortic landmark detection and aorta segmentation to derive 8 vessel segments. Associated calcifications were detected and their volumes measured using a mean-based density thresholding. Algorithm parameters (calcium cluster size threshold, aortic mask dilatation) were varied to determine optimal performance for the upper ascending aorta that encompasses the aortic clamping zone. A binary visual rating served as a reference. Standard estimates of diagnostic accuracy and inter-rater agreement using Cohen's Kappa were calculated. RESULTS: Thoracic aortic calcifications were observed in 74% of patients with a prevalence of 27-70% by aorta segment. Using different parameter combinations, the algorithm provided binary ratings for all scans and segments. The best performing parameter combination for the presence of calcifications in the aortic clamping zone yielded a sensitivity of 93% and a specificity of 82%, with an area under the receiver operating characteristic curve of 0.874. Using these parameters, the inter-rater agreement ranged from κ 0.66 to 0.92 per segment. CONCLUSIONS: Fully automated segmental detection of thoracic aortic calcifications in chest CT performs with high accuracy. This includes the critical preoperative assessment of the aortic clamping zone.


Assuntos
Aorta Torácica , Doenças da Aorta , Aprendizado Profundo , Tomografia Computadorizada por Raios X , Calcificação Vascular , Humanos , Aorta Torácica/diagnóstico por imagem , Estudos Retrospectivos , Feminino , Masculino , Calcificação Vascular/diagnóstico por imagem , Idoso , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Doenças da Aorta/diagnóstico por imagem , Algoritmos , Idoso de 80 Anos ou mais
2.
Diagnostics (Basel) ; 14(9)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38732294

RESUMO

Reduced iodine loads for computed tomography (CT)-based vascular assessment prior to transcatheter aortic valve implantation (TAVI) may be feasible in conjunction with a spectral detector CT scanner. This prospective single-center study considered 100 consecutive patients clinically referred for pre-TAVI CT. They were examined on a dual-layer detector CT scanner to obtain an ECG-gated cardiac scan and a non-ECG-gated aortoiliofemoral scan. Either a standard contrast media (SCM) protocol using 80 mL Iohexol 350 mgI/mL (iodine load: 28 gI) or a body-mass-index adjusted reduced contrast media (RCM) protocol using 40-70 mL Iohexol 350 mgI/mL (iodine load: 14-24.5 gI) were employed. Conventional images and virtual monoenergetic images at 40-80 keV were reconstructed. A threshold of 250 HU was set for sufficient attenuation along the arterial access pathway. A qualitative assessment used a five-point Likert scale. Sufficient attenuation in the thoracic aorta was observed for all patients in both groups using conventional images. In the abdominal, iliac, and femoral segments, sufficient attenuation was observed for the majority of patients when using virtual monoenergetic images (SCM: 96-100% of patients, RCM: 88-94%) without statistical difference between both groups. Segments with attenuation measurements below the threshold remained qualitatively assessable as well. Likert scores were 'excellent' for virtual monoenergetic images 50 keV and 55 keV in both groups (RCM: 1.2-1.4, SCM: 1.2-1.3). With diagnostic image quality maintained, it can be concluded that reduced iodine loads of 14-24.5 gI are feasible for pre-TAVI vascular assessment on a spectral detector CT scanner.

3.
Radiol Med ; 129(5): 669-676, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38512614

RESUMO

PURPOSE: To investigate the value of photon-counting detector CT (PCD-CT) derived virtual non-contrast (VNC) reconstructions to identify renal cysts in comparison with conventional dual-energy integrating detector (DE EID) CT-derived VNC reconstructions. MATERIAL AND METHODS: We prospectively enrolled consecutive patients with simple renal cysts (Bosniak classification-Version 2019, density ≤ 20 HU and/or enhancement ≤ 20 HU) who underwent multiphase (non-contrast, arterial, portal venous phase) PCD-CT and for whom non-contrast and portal venous phase DE EID-CT was available. Subsequently, VNC reconstructions were calculated for all contrast phases and density as well as contrast enhancement within the cysts were measured and compared. MRI and/or ultrasound served as reference standards for lesion classification. RESULTS: 19 patients (1 cyst per patient; age 69.5 ± 10.7 years; 17 [89.5%] male) were included. Density measurements on PCD-CT non-contrast and VNC reconstructions (arterial and portal venous phase) revealed no significant effect on HU values (p = 0.301). In contrast, a significant difference between non-contrast vs. VNC images was found for DE EID-CT (p = 0.02). For PCD-CT, enhancement for VNC reconstructions was < 20 HU for all evaluated cysts. DE EID-CT measurements revealed an enhancement of > 20 HU in five lesions (26.3%) using the VNC reconstructions, which was not seen with the non-contrast images. CONCLUSION: PCD-CT-derived VNC images allow for reliable and accurate characterization of simple cystic renal lesions similar to non-contrast scans whereas VNC images calculated from DE EID-CT resulted in substantial false characterization. Thus, PCD-CT-derived VNC images may substitute for non-contrast images and reduce radiation dose and follow-up imaging.


Assuntos
Doenças Renais Císticas , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Doenças Renais Císticas/diagnóstico por imagem , Pessoa de Meia-Idade , Fótons , Idoso de 80 Anos ou mais , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
4.
Int J Cardiovasc Imaging ; 40(4): 811-820, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38360986

RESUMO

To compare the diagnostic value of ultrahigh-resolution CT-angiography (UHR-CTA) compared with high-pitch spiral CTA (HPS-CTA) using a first-generation, dual-source photon-counting CT (PCD-CT) scanner for preprocedural planning of transcatheter aortic valve replacement (TAVR). Clinically referred patients with severe aortic valve stenosis underwent both, retrospective ECG-gated cardiac UHR-CTA (collimation: 120 × 0.2 mm) and prospective ECG-triggered aortoiliac HPS-CTA (collimation: 144 × 0.4 mm, full spectral capabilities) for TAVR planning from August 2022 to March 2023. Radiation dose was extracted from the CT reports, and the effective dose was calculated. Two radiologists analyzed UHR-CTA and HPS-CTA datasets, assessing the image quality of the aortic annulus, with regard to the lumen visibility and margin delineation using a 4-point visual-grading scale (ranges: 4 = "excellent" to 1 = "poor"). Aortic annulus area (AAA) measurements were taken for valve prosthesis sizing, with retrospective UHR-CTA serving as reference standard. A total of 64 patients were included (mean age, 81 years ± 7 SD; 28 women) in this retrospective study. HPS-CTA showed a lower radiation dose, 4.1 mSv vs. 12.6 mSv (p < 0.001). UHR-CTA demonstrated higher image quality to HPS-CTA (median score, 4 [IQR, 3-4] vs. 3 [IQR, 2-3]; p < 0.001). Quantitative assessments of AAA from both CTA datasets were strongly positively correlated (mean 477.4 ± 91.1 mm2 on UHR-CTA and mean 476.5 ± 90.4 mm2 on HPS-CTA, Pearson r2 = 0.857, p < 0.001) with a mean error of 22.3 ± 24.6 mm2 and resulted in identical valve prosthesis sizing in the majority of patients (91%). Patients with lower image quality on HPS-CTA (score value 1 or 2, n = 28) were more likely to receive different sizing recommendations (82%). Both UHR-CTA and HPS-CTA acquisitions using photon-counting CT technology provided reliable aortic annular assessments for TAVR planning. While UHR-CTA offers superior image quality, HPS-CTA is associated with lower radiation exposure. However, severely impaired image quality on HPS-CTA may impact on prosthesis sizing, suggesting that immediate post-scan image evaluations may require complementary UHR-CTA scanning.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Técnicas de Imagem de Sincronização Cardíaca , Angiografia por Tomografia Computadorizada , Eletrocardiografia , Próteses Valvulares Cardíacas , Valor Preditivo dos Testes , Desenho de Prótese , Doses de Radiação , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Feminino , Masculino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Idoso , Substituição da Valva Aórtica Transcateter/instrumentação , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Exposição à Radiação , Tomada de Decisão Clínica , Fótons , Tomografia Computadorizada Multidetectores
5.
Eur Radiol ; 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38177617

RESUMO

OBJECTIVES: To determine the diagnostic accuracy of ultra-high-resolution photon-counting detector CT angiography (UHR PCD-CTA) for evaluating coronary stent patency compared to invasive coronary angiography (ICA). METHODS: Consecutive, clinically referred patients with prior coronary stent implantation were prospectively enrolled between August 2022 and March 2023 and underwent UHR PCD-CTA (collimation, 120 × 0.2 mm). Two radiologists independently analyzed image quality of the in-stent lumen using a 5-point Likert scale, ranging from 1 ("excellent") to 5 ("non-diagnostic"), and assessed all coronary stents for the presence of in-stent stenosis (≥ 50% lumen narrowing). The diagnostic accuracy of UHR PCD-CTA was determined, with ICA serving as the standard of reference. RESULTS: A total of 44 coronary stents in 18 participants (mean age, 83 years ± 6 [standard deviation]; 12 women) were included in the analysis. In 3/44 stents, both readers described image quality as non-diagnostic, whereas reader 2 noted a fourth stent to have non-diagnostic image quality. In comparison to ICA, UHR PCD-CTA demonstrated a sensitivity, specificity, and accuracy of 100% (95% CI [confidence interval] 47.8, 100), 92.3% (95% CI 79.1, 98.4), and 93.2% (95% CI 81.3, 98.6) for reader 1 and 100% (95% CI 47.8, 100), 87.2% (95% CI 72.6, 95.7), and 88.6% (95% CI 75.4, 96.2) for reader 2, respectively. Both readers observed a 100% negative predictive value (36/36 stents and 34/34 stents). Stent patency inter-reader agreement was 90.1%, corresponding to a substantial Cohen's kappa value of 0.72. CONCLUSIONS: UHR PCD-CTA enables non-invasive assessment of coronary stent patency with high image quality and diagnostic accuracy. CLINICAL RELEVANCE STATEMENT: Ultra-high-resolution photon-counting detector CT angiography represents a reliable and non-invasive method for assessing coronary stent patency. Its high negative predictive value makes it a promising alternative over invasive coronary angiography for the rule-out of in-stent stenosis. KEY POINTS: • CT-based evaluation of coronary stent patency is limited by stent-induced artifacts and spatial resolution. • Ultra-high-resolution photon-counting detector CT accurately evaluates coronary stent patency compared to invasive coronary angiography. • Photon-counting detector CT represents a promising method for the non-invasive rule-out of in-stent stenosis.

6.
Rofo ; 196(1): 25-35, 2024 Jan.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37793417

RESUMO

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. KEY POINTS: · Photon-counting computed tomography (PCD-CT) is being used for the first time in routine clinical practice, enabling a significant dose reduction in critical patient populations such as oncology, cardiology, and pediatrics.. · Compared to conventional CT, PCD-CT enables a reduction in electronic image noise.. · Due to the spectral data sets, PCD-CT enables fully comprehensive post-processing applications.. CITATION FORMAT: · Hagen F, Soschynski M, Weis M et al. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. Fortschr Röntgenstr 2024; 196: 25 - 34.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Criança , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Tórax , Imagens de Fantasmas , Pulmão
7.
Sci Rep ; 13(1): 14806, 2023 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-37684412

RESUMO

Accurate small vessel stent visualization using CT remains challenging. Photon-counting CT (PCD-CT) may help to overcome this issue. We systematically investigate PCD-CT impact on small vessel stent assessment compared to energy-integrating-CT (EID). 12 water-contrast agent filled stents (3.0-8 mm) were scanned with patient-equivalent phantom using clinical PCD-CT and EID-CT. Images were reconstructed using dedicated vascular kernels. Subjective image quality was evaluated by 5 radiologists independently (5-point Likert-scale; 5 = excellent). Objective image quality was evaluated by calculating multi-row intensity profiles including edge rise slope (ERS) and coefficient-of-variation (CV). Highest overall reading scores were found for PCD-CT-Bv56 (3.6[3.3-4.3]). In pairwise comparison, differences were significant for PCD-CT-Bv56 vs. EID-CT-Bv40 (p ≤ 0.04), for sharpness and blooming respectively (all p < 0.05). Highest diagnostic confidence was found for PCD-CT-Bv56 (p ≤ 0.2). ANOVA revealed a significant effect of kernel strength on ERS (p < 0.001). CV decreased with stronger PCD-CT kernels, reaching its lowest in PCD-CT-Bv56 and highest in EID-CT reconstruction (p ≤ 0.05). We are the first study to verify, by phantom setup adapted to real patient settings, PCD-CT with a sharp vascular kernel provides the most favorable image quality for small vessel stent imaging. PCD-CT may reduce the number of invasive coronary angiograms, however, more studies needed to apply our results in clinical practice.


Assuntos
Prótese Vascular , Doença da Artéria Coronariana , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Diagnóstico por Imagem , Imagens de Fantasmas , Humanos , Doença da Artéria Coronariana/terapia
8.
Eur Heart J Cardiovasc Imaging ; 24(12): 1672-1681, 2023 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-37409579

RESUMO

AIMS: To determine the conditions under which early hypoattenuated leaflet thickening (HALT) after transcatheter aortic valve implantation (TAVI) becomes haemodynamically relevant. METHODS AND RESULTS: The study included 100 patients (age: 81.5 ± 5.5 years; female 63%), thereof 50 patients with HALT. After anonymization and randomization, blinded readers measured maximum thrombus thickness per prosthesis (MT_pr) and movement restriction (MR_pr) on electrocardiogram (ECG)-gated whole heart cycle computed tomography angiography. These measurements were compared with echocardiographic mean pressure gradient (mPG), its increase from baseline (ΔmPG), and Doppler velocity index (DVI). Haemodynamic valve deterioration (HVD) was defined as mPG > 20 mmHg. Age, body mass index, valve type, valve size, left ventricular ejection fraction, and atrial fibrillation were considered as influencing factors. Multiple regression analysis revealed that only valve size (P = 0.001) and MT_pr (P = 0.02) had a significant influence on mPG. In an interaction model, valve size moderated the effect of MT_pr on mPG significantly (P = 0.004). Sub-group analysis stratified by valve sizes showed a strong correlation between MT_pr and echocardiographic parameters for 23 mm valves (mPG: r = 0.57, ΔmPG: r = 0.68, DVI: r = 0.55, each with P < 0.001), but neither for 26 nor 29 mm valves (r < 0.2, P > 0.2 for all correlations). Six of seven prostheses with HVD had a 23 mm valve diameter, while one had 29 mm (P = 0.02). CONCLUSION: Early HALT rarely causes significant mPG increase. Our study shows that valve size is a key factor influencing the haemodynamic impact of HALT. In small valve sizes, mPG is more likely to increase. Our study is the first to offer in vivo evidence supporting previous in vitro findings on this topic.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Volume Sistólico , Trombose/diagnóstico por imagem , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Masculino
9.
Radiology ; 307(5): e223305, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37338354

RESUMO

Background Recently introduced photon-counting CT may improve noninvasive assessment of patients with high risk for coronary artery disease (CAD). Purpose To determine the diagnostic accuracy of ultrahigh-resolution (UHR) coronary CT angiography (CCTA) in the detection of CAD compared with the reference standard of invasive coronary angiography (ICA). Materials and Methods In this prospective study, participants with severe aortic valve stenosis and clinically indicated CT for transcatheter aortic valve replacement planning were consecutively enrolled from August 2022 to February 2023. All participants were examined with a dual-source photon-counting CT scanner using a retrospective electrocardiography-gated contrast-enhanced UHR scanning protocol (tube voltage, 120 or 140 kV; collimation, 120 × 0.2 mm; 100 mL of iopromid; no spectral information). Subjects underwent ICA as part of their clinical routine. A consensus assessment of image quality (five-point Likert scale: 1 = excellent [absence of artifacts], 5 = nondiagnostic [severe artifacts]) and a blinded independent reading for the presence of CAD (stenosis ≥50%) were performed. UHR CCTA was compared with ICA using area under the receiver operating characteristic curve (AUC). Results Among 68 participants (mean age, 81 years ± 7 [SD]; 32 male, 36 female), the prevalence of CAD and prior stent placement was 35% and 22%, respectively. The overall image quality was excellent (median score, 1.5 [IQR, 1.3-2.0]). The AUC of UHR CCTA in the detection of CAD was 0.93 per participant (95% CI: 0.86, 0.99), 0.94 per vessel (95% CI: 0.91, 0.98), and 0.92 per segment (95% CI: 0.87, 0.97). Sensitivity, specificity, and accuracy, respectively, were 96%, 84%, and 88% per participant (n = 68); 89%, 91%, and 91% per vessel (n = 204); and 77%, 95%, and 95% per segment (n = 965). Conclusion UHR photon-counting CCTA provided high diagnostic accuracy in the detection of CAD in a high-risk population, including subjects with severe coronary calcification or prior stent placement. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Williams and Newby in this issue.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos Prospectivos , Estudos Retrospectivos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos
10.
Diagnostics (Basel) ; 13(12)2023 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-37370957

RESUMO

BACKGROUND: This study investigates whether the scan length adjustment of prospectively ECG-triggered coronary CT angiography (CCTA) using calcium-scoring CT (CAS-CT) images can reduce overall radiation doses. METHODS: A retrospective analysis was conducted on 182 patients who underwent CAS-CT and prospectively ECG-triggered CCTA using a second-generation Dual-Source CT scanner. CCTA planning was based on CAS-CT images, for which simulated scout view planning was performed for comparison. Effective doses were compared between two scenarios: Scenario 1-CAS-CT-derived CCTA + CAS-CT and Scenario 2-scout-view-derived CCTA without CAS-CT. Dose differences were further analyzed with respect to scan mode and body mass index. RESULTS: Planning CCTA using CAS-CT led to a shorter scan length than planning via scout view (114.3 ± 9.7 mm vs. 133.7 ± 13.2 mm, p < 0.001). The whole-examination effective dose was slightly lower for Scenario 1 (3.2 [1.8-5.3] mSv vs. 3.4 [1.5-5.9] mSv; p < 0.001, n = 182). Notably, Scenario 1 resulted in a significantly lower radiation dose for sequential scans and obese patients. Only high-pitch spiral CCTA showed dose reduction in Scenario 2. CONCLUSIONS: Using CAS-CT for planning prospectively ECG-triggered CCTA reduced the overall radiation dose administered compared to scout view planning without CAS-CT, except for high-pitch spiral CCTA, where a slightly opposite effect was observed.

11.
Rofo ; 195(6): 495-504, 2023 06.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-36863368

RESUMO

BACKGROUND: Kidney transplantations are increasing due to demographic changes and are the treatment of choice for end-stage renal disease. Non-vascular and vascular complications may occur in the early phase after transplantation and at later stages. Overall postoperative complications after renal transplantations occur in approximately 12 % to 25 % of renal transplant patients. In these cases, minimally invasive therapeutic interventions are essential to ensure long-term graft function. This review article focuses on the most critical vascular complications after renal transplantation and highlights current recommendations for interventional treatment. METHOD: A literature search was performed in PubMed using the search terms "kidney transplantation", "complications", and "interventional treatment". Furthermore, the 2022 annual report of the German Foundation for Organ Donation and the EAU guidelines for kidney transplantation (European Association of Urology) were considered. RESULTS AND CONCLUSION: Image-guided interventional techniques are favorable compared with surgical revision and should be used primarily for the treatment of vascular complications. The most common vascular complications after renal transplantation are arterial stenoses (3 %-12.5 %), followed by arterial and venous thromboses (0.1 %-8.2 %) and dissection (0.1 %). Less frequently, arteriovenous fistulas or pseudoaneurysms occur. In these cases, minimally invasive interventions show a low complication rate and good technical and clinical results. Diagnosis, treatment, and follow-up should be performed in an interdisciplinary approach at highly specialized centers to ensure the preservation of graft function. Surgical revision should be considered only after exhausting minimally invasive therapeutic strategies. KEY POINTS: · Vascular complications after renal transplantation occur in 3 % to 15 % of patients.. · Image-guided interventional procedures should be performed primarily to treat vascular complications of renal transplantation.. · Minimally invasive interventions have a low complication rate with good technical and clinical outcomes.. CITATION FORMAT: · Verloh N, Doppler M, Hagar MT et al. Interventional Management of Vascular Complications after Renal Transplantation. Fortschr Röntgenstr 2023; 195: 495 - 504.


Assuntos
Falso Aneurisma , Fístula Arteriovenosa , Transplante de Rim , Humanos , Transplante de Rim/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/terapia , Fístula Arteriovenosa/terapia
12.
J Clin Med ; 11(20)2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36294324

RESUMO

The aim of this paper is to evaluate the diagnostic image quality of spectral dual-source photon-counting detector coronary computed tomography angiography (PCD-CCTA) for coronary artery disease in a multicenter study. The image quality (IQ), assessability, contrast-to-noise ratio (CNR), Agatston score, and radiation exposure were measured. Stenoses were quantified and compared with invasive coronary angiography, if available. A total of 92 subjects (65% male, age 58 ± 14 years) were analyzed. The prevalence of significant coronary artery disease (CAD) (stenosis ≥ 50%) was 17% of all patients, the range of the Agatston score was 0−2965 (interquartile range (IQR) 0−135). The IQ was very good (one, IQR one−two), the CNR was very high (20 ± 10), and 5% of the segments were rated non-diagnostic. The IQ and assessability were higher in proximal coronary segments (p < 0.001). Agatston scores up to 600 did not significantly affect the assessability of the coronary segments (p = 0.3). Heart rate influenced assessability only at a high-pitch mode (p = 0.009). For the invasive coronary angiography (ICA) subgroup (n = nine), the diagnostic performance for CAD per segment was high (sensitivity 92%, specificity 96%), although the limited number of patients who underwent both diagnostic modalities limits the generalization of this finding at this stage. PCD-CCTA provides good image quality for low and moderate levels of coronary calcifications.

13.
Front Cardiovasc Med ; 9: 911548, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35734273

RESUMO

Background: Aim of this study was to report and to identify risk factors for distal aortic failure following aortic arch replacement via the frozen elephant trunk (FET) procedure. Methods: One hundred eighty-six consecutive patients underwent the FET procedure for acute and chronic aortic dissection. Our cohort was divided into patients with and without distal aortic failure. Distal aortic failure was defined as: (I) distal aortic reintervention, (II) aortic diameter dilatation to ≥ 6 cm or > 5 mm growth within 6 months, (III) development of a distal stent-graft-induced new entry (dSINE) and/or (IV) aortic-related death. Preoperative, intraoperative, postoperative and aortic morphological data were analyzed. Results: Distal aortic failure occurred in 88 (47.3%) patients. Forty-six (24.7%) required a distal reintervention, aortic diameter dilatation was observed in 9 (4.8%) patients, a dSINE occurred in 22 (11.8%) patients and 11 (6.4%) suffered an aortic-related death. We found no difference in the number of communications between true and false lumen (p = 0.25) but there were significantly more communications between Ishimaru zone 6-8 in the distal aortic failure group (p = 0.01). The volume of the thoracic descending aorta measured preoperatively and postoperatively within 36 months afterward was significantly larger in patients suffering distal aortic failure (p < 0.001; p = 0.011). Acute aortic dissection (SHR 2.111; p = 0.007), preoperative maximum descending aortic diameter (SHR 1.029; p = 0.018) and preoperative maximum aortic diameter at the level of the diaphragm (SHR 1.041; p = 0.012) were identified as risk factors for distal aortic failure. Conclusion: The incidence and risk of distal aortic failure following the FET procedure is high. Especially those patients with more acute and more extensive aortic dissections or larger preoperative descending aortic diameters carry a substantially higher risk of developing distal aortic failure. The prospective of the FET technique as a single-step treatment for aortic dissection seems low and follow-up in dedicated aortic centers is therefore paramount.

14.
Rofo ; 194(6): 613-624, 2022 06.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-35231938

RESUMO

BACKGROUND: Coronary CT angiography (cCTA) is a class 1 recommendation in the current guidelines by the European Society of Cardiology (ESC) for excluding significant coronary artery stenosis. To achieve optimal image quality at a low radiation dose, the imaging physician may choose different acquisition modes. Therefore, the consensus guidelines by the Society of Cardiovascular Computed Tomography (SCCT) provide helpful guidance for this procedure. METHOD: The article provides practical recommendations for the application and acquisition of cCTA based on the current literature and our own experience. RESULTS AND CONCLUSION: According to current ESC guidelines, cCTA is recommended in symptomatic patients with a low or intermediate clinical likelihood for coronary artery disease. We recommend premedication with beta blockers and nitrates prior to CT acquisition under certain conditions even with the latest CT scanner generations. The most current CT scanners offer three possible scan modes for cCTA acquisition. Heart rate is the main factor for selecting the scan mode. Other factors may be coronary calcifications and body mass index (BMI). KEY POINTS: · CCTA is a valid method to exclude coronary artery disease in patients with a low to intermediate clinical likelihood.. · Even with the latest generation CT scanners, premedication with beta blockers and nitrates can improve image quality at low radiation exposure.. · Current CT scanners usually provide retrospective ECG gating and prospective ECG triggering. Dual-source scanners additionally provide a "high pitch" scan mode to scan the whole heart during one heartbeat, which may also be achieved using single-source scanners with broad detectors in some cases.. · Besides the available scanner technology, the choice of scan mode primarily depends on heart rate and heart rate variability (e. g., arrhythmia).. CITATION FORMAT: · Soschynski M, Hagar MT, Taron J et al. Update for the Performance of CT Coronary Angiography. Fortschr Röntgenstr 2022; 194: 613 - 624.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Nitratos , Estudos Prospectivos , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
15.
Eur J Radiol ; 133: 109366, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33166834

RESUMO

OBJECTIVES: To evaluate a systolic ECG-gated high-pitch aortoiliac computed tomography (CT) angiography for planning transcatheter aortic valve implantation (TAVI). METHODS: Patients referred for TAVI underwent a combined CT imaging with retrospective, multiphasic ECG-gating of the heart and systolic ECG-gated high-pitch aortoiliac CT angiography. Consecutive patients were retrospectively included in this study group. Heart rate (HR) and heart rate variability (HRV) were assessed during the high-pitch ECG prediction phase. Aortic annulus area (AAA) was planimetrically quantified on both datasets. While only one moment of cardiac cycle was available for measurements in the high-pitch CT, the point of time in the multiphasic CT was chosen, where AAA yielded maximum size. Hypothetical prosthesis sizing was compared between multiphasic vs. high-pitch CT. RESULTS: Among 61 patients (44.2 % men, mean age: 83.3 ± 5.5 years) average heart rate and HRV were 71.0 ± 13.4 bpm and 7.3 ± 8.5 bpm. 20 patients (32.7 %) had atrial fibrillation at the time of image acquisition. There was a strong correlation of AAA as derived from multiphasic vs. the high-pitch CT (r = 0.98). The difference in AAA was 10.5 ± 17.1mm2 (455.1 ± 83.0 mm2 for multiphasic vs. 444.5 ± 87.2 mm2 for high-pitch CT) and did not reach statistical significance (p = 0.08). Hypothetical prosthesis sizing showed an agreement in 55 of 61 patients (90.2 %). A sizing based on the high-pitch CT resulted in smaller prosthesis choice in 6 patients, all of them suffering from atrial fibrillation. Mean effective radiation dose was 10.9 ± 6.1 mSv for cardiac CTA and 4.1 ± 1.0 mSv for high-pitch CTA. CONCLUSION: For patients with sinus rhythm, systolic high-pitch aortoiliac CTA provides adequate prosthesis size selection as compared with multiphasic ECG-gated cardiac CTA and may result in significantly reduced radiation exposition.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Aorta , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA