Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Hum Fertil (Camb) ; 23(4): 282-288, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30773064

RESUMO

Telomeres are a specific base sequence of DNA, responsible for chromosome stability and DNA protection. We aimed to investigate the association between telomere systems and IVF outcomes according to patients' BMI. For all telomere characteristics, there was a distinct trend towards shorter telomeres and activation of telomere shortening compensatory mechanisms in the BMI group >25 kg/m2, reaching statistical significance for senescence only (r = 0.7, p value <0.01). There was a trend towards a relationship between telomere length and number of oocytes between telomere length and fertilization rate, but these did not reach a statistical significance. For pregnancy outcome, all telomere characteristics were better for the patients who achieved a pregnancy. While there is paucity of data in the literature concerning the association between telomere characteristics and infertility, telomeres might contribute to the association between obesity and sub-optimal IVF results.


Assuntos
Índice de Massa Corporal , Fertilização in vitro/estatística & dados numéricos , Homeostase do Telômero , Adulto , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Humanos , Gravidez , Adulto Jovem
2.
PLoS One ; 13(5): e0196706, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29787560

RESUMO

BACKGROUND: Neutrophils to lymphocytes ratio (NLR) and platelets to lymphocytes ratio (PLR) are both inflammatory ratios that can be easily calculated from a simple blood count. They are frequently reported and tested as prognostic factors in several medical disciplines. Pregnancy involves special reference values for laboratory assays. OBJECTIVE: The aim of this study was to define pregnancy-related reference values for NLR and PLR according to trimester, background morbidity and according to the patient's age. STUDY DESIGN: A retrospective analysis of a large cohort undergoing community-based pregnancy surveillance between the years 2011-2016. Data were analyzed according to high-risk patient versus normal-risk patient. RESULTS: A total of 11,415 patients were included. Mean PLR and NLR values were 136.3±44.3, 2.6±1, respectively during the first trimester, 144.6±47.1, 4.0±1.4 respectively during the second trimester and 118.1±42.0, 3.5±1.2 respectively during the third trimester. No difference was detected between the high-risk and the normal population (P-values 0.3, 0.5 and 0.4 for PLR in each trimester respectively and 0.3, 0.4, 0.6 for NLR in each trimester, respectively). No differences were detected among parity categories. The correlation between patient's age and either PLR and NLR was a weak positive correlation (though statistically significant). Both PLR and NLR reached a maximum value during the second trimester. The differences between mean NLR and PLR between trimesters were significant (P <0.01 for all differences tested). PLR rises in the presence of anemia, reaching statistical significance (P-value for PLR in each trimester was <0.01). NLR showed an opposite trend (P-values for NLR were 0.4, 0.005 and 0.06 in each trimester, respectively). CONCLUSIONS: In our cohort, there were generally no differences between the high-risk and the normal population, excluding patients with a fibroid uterus or inflammatory bowel disease who presented a significantly elevated PLR through all trimesters. Both PLR and NLR reached a maximum value during the second trimester and were positively correlated with age. We anticipate that the population-based data will assist in providing accurate reference values for future research testing NLR and PLR measures during pregnancy.


Assuntos
Plaquetas/fisiologia , Linfócitos/fisiologia , Neutrófilos/fisiologia , Adulto , Feminino , Humanos , Contagem de Linfócitos/métodos , Pessoa de Meia-Idade , Contagem de Plaquetas/métodos , Gravidez , Estudos Retrospectivos , Adulto Jovem
3.
J Matern Fetal Neonatal Med ; 25(10): 2135-7, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22533712

RESUMO

OBJECTIVE: To establish standards for the deviation of vacuum cup placement from the ideal location during operative delivery in an academic center. METHODS: Data on 92 vacuum deliveries were prospectively obtained. The actual point on the newborns head was determined and both midline and anterior-posterior line deviations from the ideal point of placement were calculated. RESULTS: The most common indication for vacuum extraction was a nonreassuring fetal heart rate (66.7%). The average deviation on the mid anterior-posterior line was 3.72 ± 1.46 cm; the average midline-lateral deviation was 1.92 ± 1.33 cm. There was no statistically significant difference in the cup placement deviations between deliveries performed by residents and consultants. The vacuum procedure failed in 8.6% of the cases. CONCLUSIONS: Accurate placement of the vacuum cup on the fetal head is considered to be clinically important. This assumption requires scientific clinical proof. Our local standard for deviation was established and will serve for audit. If safer neonatal and maternal outcomes are demonstrated, the deviation from the ideal placement location ought to become a universal quality measure for vacuum deliveries.


Assuntos
Competência Clínica/estatística & dados numéricos , Erros Médicos/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Vácuo-Extração/normas , Adulto , Competência Clínica/normas , Feminino , Humanos , Erros Médicos/prevenção & controle , Avaliação de Processos e Resultados em Cuidados de Saúde , Gravidez , Estudos Prospectivos , Vácuo-Extração/instrumentação , Vácuo-Extração/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA