Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1317: 342914, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39030012

RESUMO

BACKGROUND: Human sweat can be collected non-invasively with low infectivity; however, its application as a determination method has been challenged due to the presence of trace amounts of chiral metabolites. Moreover, its application as a biological fluid for disease diagnosis has not been previously reported. In this study, the human dried sweat spot paper (DSSP) method was proposed for the derivatization of a novel mass spectrometric chiral probe, N-[1-Oxo-5-(triphenylphosphonium) pentyl]-(S)-3-aminopyrrolidine (OTPA), determination and resolution of DL-lactic acid (DL-LA) enantiomers in human elbow sweat. RESULTS: The methodological validation revealed the resolution (Rs) as 1.78, the limit of detection (S/N = 3) as 20.83 fmol, good linearity (R2 ≥ 0.9996), and the intra-day and intra-day stability with RSD ranging from 0.53 to 10.85 %, while the average recovery rate of D-LA and L-LA were 104.00 % ± 4.68 % and 107.41 % ± 8.34 %, respectively, with high accuracy. In addition, the method was applied for the determination of DL-LA in the sweat on elbow of 10 healthy volunteers and 30 diabetic patients. The results demonstrated that the D/L ratio and L/D ratio were significantly different (p < 0.0001). In addition, a moderate positive linear correlation between the D/L-LA ratio in human sweat and fasting blood glucose level (r = 0.7744, p < 0.0001) was observed, thereby suggesting that the D/L ratio of lactate in human sweat correlate the glucose level in human fasting blood. SIGNIFICANCE AND NOVELTY: The D/L lactate ratio in human sweat could be used as a potential biomarker for diabetes screening. The method can be used to screen for diabetes by providing a dry sweat paper to test equipment and has the potential to be a non-invasive early-warning diagnostic tool for diabetes.


Assuntos
Biomarcadores , Diabetes Mellitus , Ácido Láctico , Papel , Suor , Humanos , Suor/química , Biomarcadores/análise , Estereoisomerismo , Ácido Láctico/análise , Diabetes Mellitus/diagnóstico , Masculino , Adulto , Espectrometria de Massas , Feminino , Pessoa de Meia-Idade , Limite de Detecção
2.
J Chromatogr A ; 1719: 464757, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38394785

RESUMO

Monitoring changes in the content of chiral thiol compounds in the human body is crucial for the early diagnosis of oxidative stress-related diseases and the exploration of their pathogenesis. To address this, we synthesized a novel isotope mass spectrometry (MS) probe, denoted as (R)-(5-(3-isothiocyanato (13C) pyrrolidin-1-yl)-5-oxopentyl) triphenylphosphonium (N13CS-OTPP), with triphenylphosphine as its parent structure. In this study, we established a new ultra-high-performance liquid chromatography high-resolution mass spectrometry (UHPLCHRMS) relative quantitative method to monitor chiral thiol compounds in human urine under varying oxidative stress conditions. This method relies on the ratio of 12C/13C isotope-labeled peak areas. To assess the chiral separation efficiency of N13CS-OTPP, we employed three types of thiol compounds (D/L-GSH, D/L-Cys, and D/L-Hcy) and observed separation degrees (Rs) ranging from 1.82 to 1.89. We further validated the accuracy and feasibility of our relative quantitative methods using D/L-Cys-as a model compound. N12C/13CS-OTPP-Cys-exhibited excellent linearity (R2 = 0.9993-0.9994) across different molar ratios (D/L-Cys = 10:1, 4:1, 2:1, 1:1, 1:2, 1:4, 1:10) and achieved a low limit of detection (LOD) of 2.5 fmol. Additionally, we monitored the dynamic changes in urine D/L-Cys-and D/L-Hcy ratios in 12 healthy volunteers (six males and six females) under various oxidative stress states. We generated fitting curves and investigated the trends in chiral thiol compounds in vivo. This study introduces a novel method for the relative quantitative monitoring of chiral thiol compounds in different oxidative stress states within the human body. It also presents a new strategy for understanding the pathogenesis of related diseases resulting from the abnormal metabolism of thiol compounds.


Assuntos
Isótopos , Compostos Organofosforados , Masculino , Feminino , Humanos , Espectrometria de Massas , Cisteína , Cromatografia Líquida de Alta Pressão/métodos
3.
Anal Chim Acta ; 1264: 341269, 2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37230719

RESUMO

Acute myocardial infarction (AMI) poses a grave threat to human life. However, most clinical biomarkers have limitations of low sensitivity and specificity. Therefore, screening novel glycan biomarkers with high sensitivity and specificity is crucial for the prevention and treatment of AMI. The novel method of ultrahigh-performance liquid chromatography coupled to quadrupole-Orbitrap high-resolution mass spectrometry (UHPLC-Q-Orbitrap HRMS) with d0/d5-BOTC probe labeling for relative quantification of glycans based on Pronase E digestion was established to screen novel glycan biomarkers in the serum of 34 AMI patients relative to healthy volunteers. The monosaccharide model D-glucosamine was used to investigate the effectiveness of the derivatization; the limit of detection (S/N = 3) was 10 amol. The accuracy was verified based on the consistency of different theoretical molar ratios (d0/d5 = 1:2, 2:1) and intensity ratios following digestion of glycoprotein ribonuclease B. Expressions of H4N4F3SA, H4N6F2, H4N6SA, H4N6F3 and H5N4FSA in the serum were significantly different (p < 0.0005) between AMI patients and healthy volunteers. The area under the receiver operating characteristic curve (AUC) for H4N6SA, H5N4FSA, and H4N6F2 was greater than 0.9039. Based on the proposed method, H4N6SA, H5N4FSA, and H4N6F2 in human serum showed high accuracy and specificity and may serve as potential glycan biomarkers, crucial for the diagnosis and treatment monitoring of AMI.


Assuntos
Polissacarídeos , Humanos , Marcação por Isótopo/métodos , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Cromatografia Líquida , Polissacarídeos/análise , Biomarcadores
4.
J Chromatogr A ; 1677: 463302, 2022 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-35820231

RESUMO

Glycans play important roles in the activity and function of monoclonal antibodies (mAbs). In this study, an isotope labeling method for the relative quantitative analysis of glycans in cetuximab, a chimeric human/mouse IgG1 monoclonal antibody that specifically targets epidermal growth factor receptor, via hydrophilic interaction LC-ultra-high-performance LC-HRMS was established based on Pronase E digestion. To this aim, novel isotope MS probes, i.e., 3-benzoyl-2-oxothiazolidine-4-carboxylic acid (d0-BOTC) and 3-(2,3,4,5,6-pentadeuterio-benzoyl)-2-oxothiazolidine-4-carboxylate acid (d5-BOTC), which include a carboxyl group to target the amino functional group in glycosylamine, were developed. The nonspecific Pronase E enzyme could simultaneously digest the peptide bound to the N- and O-glycans into glycosylamine having only one amino acid. Since the mass difference between the light- and heavy-labeled glycans was 5.0 Da, the relative abundance of their MS peaks was used to achieve the qualitative and relative quantitative analysis of glycans. Sialylglycopeptide was used as a complex glycan model to validate the accuracy of the method. The results demonstrated the good linearity (R2 ≥ 0.9994) between the experimentally detected MS intensity ratios and the theoretical molar ratios of the d0-BOTC to the corresponding d5-BOTC derivatives in the dynamic range of 0.03-10 and 0.03-20 of three orders magnitude for the d5-BOTC/d0-BOTC ratios. The reproducibility was between 0.16% and 10.70%, and the limit of detection was 13 fmol. The feasibility of the relative quantification method was investigated by analyzing the glycan content in cetuximab, finding good consistency between experimental and theoretical molar ratios (5:1, 3:1, 1:1, 1:3, 1:5) of d0/d5-BOTC-labeled glycans. Finally, 13 glycans were successfully identified in cetuximab by applying this method using an in-house Tracefinder database. This study provides a novel strategy for the high throughput analysis, identification, and functional study of glycans in mAbs.


Assuntos
Polissacarídeos , Espectrometria de Massas por Ionização por Electrospray , Animais , Cetuximab , Cromatografia Líquida de Alta Pressão , Digestão , Humanos , Marcação por Isótopo/métodos , Camundongos , Polissacarídeos/química , Pronase , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA