RESUMO
Highly efficient electromagnetic wave (EMW)-absorbing multicomposites can be fabricated by constructing particular structures using suitable components. Expanded graphite (EG) has a 3D, low-density porous structure; however, it suffers from poor impedance matching and EMW absorption properties. Based on this information, in the present study, NiCo2S4 components with different morphologies are successfully loaded onto a 3D EG surface using a facile microwave solvothermal method to achieve a synergistic effect between the different components. The NiCo2S4 content is adjusted to alter the compositional morphology and electromagnetic parameters of the composites to achieve impedance-matching and obtain excellent EMW absorption properties. The heterogeneous interface between EG and NiCo2S4 induces an inhomogeneous spatial charge distribution and enhances interfacial polarization. The defects in the material and oxygen-containing groups induce dipole polarization, which enhances the polarization-relaxation process of the composites. The 3D porous heterostructure of the "Fibonacci cauliflower"-shaped NiCo2S4/EG composites results in an optimal reflection loss of -64.93 dB at a filler rate of only 14 wt.%. Analysis of the synergistic conduction loss and polarization loss mechanisms in carbon-based materials with heterogeneous interfaces has led to the development of excellent EMW absorption materials.
RESUMO
This Viewpoint discusses the clinical vs economic success of magnetic resonance imaging combined with linear accelerator technology and its impact on patients.
RESUMO
Objective.We aim to: (1) quantify the benefits of lung sparing using non-adaptive magnetic resonance guided stereotactic body radiotherapy (MRgSBRT) with advanced motion management for peripheral lung cancers compared to conventional x-ray guided SBRT (ConvSBRT); (2) establish a practical decision-making guidance metric to assist a clinician in selecting the appropriate treatment modality.Approach.Eleven patients with peripheral lung cancer who underwent breath-hold, gated MRgSBRT on an MR-guided linear accelerator (MR linac) were studied. Four-dimensional computed tomography (4DCT)-based retrospective planning using an internal target volume (ITV) was performed to simulate ConvSBRT, which were evaluated against the original MRgSBRT plans. Metrics analyzed included planning target volume (PTV) coverage, various lung metrics and the generalized equivalent unform dose (gEUD). A dosimetric predictor for achievable lung metrics was derived to assist future patient triage across modalities.Main results.PTV coverage was high (median V100% > 98%) and comparable for both modalities. MRgSBRT had significantly lower lung doses as measured by V20 (median 3.2% versus 4.2%), mean lung dose (median 3.3 Gy versus 3.8 Gy) and gEUD. Breath-hold, gated MRgSBRT resulted in an average reduction of 47% in PTV volume and an average increase of 19% in lung volume. Strong correlation existed between lung metrics and the ratio of PTV to lung volumes (RPTV/Lungs) for both modalities, indicating that RPTV/Lungsmay serve as a good predictor for achievable lung metrics without the need for pre-planning. A threshold value of RPTV/Lungs< 0.035 is suggested to achieve V20 < 10% using ConvSBRT. MRgSBRT should otherwise be considered if the threshold cannot be met.Significance.The benefits of lung sparing using MRgSBRT were quantified for peripheral lung tumors; RPTV/Lungswas found to be an effective predictor for achievable lung metrics across modalities. RPTV/Lungscan assist a clinician in selecting the appropriate modality without the need for labor-intensive pre-planning, which has significant practical benefit for a busy clinic.
Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Pulmão , Imageamento por Ressonância Magnética , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Humanos , Radiocirurgia/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada Quadridimensional/métodos , Masculino , Feminino , Radioterapia Guiada por Imagem/métodos , Suspensão da Respiração , Idoso , Pessoa de Meia-Idade , Tratamentos com Preservação do Órgão/métodos , Órgãos em RiscoRESUMO
The challenge of mitigating pollution stemming from industrial exhaust emissions is a pressing issue in both academia and industry. This study presents the successful synthesis of nitrogen-defect-enriched graphite carbon nitride (g-C3N4) using a two-step calcination technique. Furthermore, a g-C3N4-Au heterostructure was fabricated through the photo-deposited Au quantum dots (QDs). When subjected to visible light irradiation, this heterostructure exhibited robust nitric oxide (NO) photooxidation activity and stability. With its fluffy, porous structure and large surface area, the nitrogen-defect-enriched g-C3N4 provides more active sites for photooxidation processes. The ability of g-C3N4 to absorb visible light is enhanced by the local surface plasmon resonance (LSPR) effect of Au QDs. Additionally, the lifetime of photogenerated charge carriers is extended by the presence of N defects and Au, which effectively prevent photogenerated electron-hole pairs from recombining during the photooxidation process. Moreover, the oxidation pathway of NO was analyzed through In-situ Fourier transform infrared (FT-IR) spectroscopy and Density Functional Theory (DFT) calculation. Computational findings revealed that the introduction of Au QDs decreases the activation energy of the oxidation reaction, thereby facilitating its occurrence while diminishing the formation of intermediate products. As a result, NO is predominantly converted to nitrate (NO3-). This work unveils a novel approach to constructing semiconductor-cocatalyst heterostructures and elucidates their role in NO photooxidation.
RESUMO
Stereotactic magnetic resonance (MR)-guided adaptive radiotherapy (SMART) for renal cell carcinoma may result in more precise treatment delivery through the capabilities for improved image quality, daily adaptive planning, and accounting for respiratory motion during treatment with real-time MR tracking. In this study, we aimed to characterize the safety and feasibility of SMART for localized kidney cancer. Twenty patients with localized kidney cancer (ten treated in a prospective phase 1 trial and ten in the supplemental cohort) were treated to 40 Gy in five fractions on a 0.35 T MR-guided linear accelerator with daily adaptive planning and a cine MR-guided inspiratory breath hold technique. The median follow-up time was 17 mo (interquartile range: 13-20 months). A single patient developed local failure at 30 mo. No grade ≥3 adverse events were reported. The mean decrease in estimated glomerular filtration rate was -1.8 ml/min/1.73 m2 (95% confidence interval or CI [-6.6 to 3.1 ml/min/1.73 m2]), and the mean decrease in tumor diameter was -0.20 cm (95% CI [-0.6 to 0.2 cm]) at the last follow-up. Anterior location and overlap of the 25 or 28 Gy isodose line with gastrointestinal organs at risk were predictive of the benefit from online adaptive planning. Kidney SMART is feasible and, at the early time point evaluated in this study, was well tolerated with minimal decline in renal function. More studies are warranted to further evaluate the safety and efficacy of this technique. PATIENT SUMMARY: For patients with localized renal cell carcinoma who are not surgical candidates, stereotactic magnetic resonance--guided adaptive radiotherapy is a feasible and safe noninvasive treatment option that results in minimal impact on kidney function.
Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Radiocirurgia , Humanos , Carcinoma de Células Renais/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Prospectivos , Radiocirurgia/métodos , Neoplasias Renais/radioterapia , Rim , Espectroscopia de Ressonância MagnéticaRESUMO
BACKGROUND/PURPOSE: Central/ultra-central thoracic tumors are challenging to treat with stereotactic radiotherapy due potential high-grade toxicity. Stereotactic MR-guided adaptive radiation therapy (SMART) may improve the therapeutic window through motion control with breath-hold gating and real-time MR-imaging as well as the option for daily online adaptive replanning to account for changes in target and/or organ-at-risk (OAR) location. MATERIALS/METHODS: 26 central (19 ultra-central) thoracic oligoprogressive/oligometastatic tumors treated with isotoxic (OAR constraints-driven) 5-fraction SMART (median 50 Gy, range 35-60) between 10/2019-10/2022 were reviewed. Central tumor was defined as tumor within or touching 2 cm around proximal tracheobronchial tree (PBT) or adjacent to mediastinal/pericardial pleura. Ultra-central was defined as tumor abutting the PBT, esophagus, or great vessel. Hard OAR constraints observed were ≤ 0.03 cc for PBT V40, great vessel V52.5, and esophagus V35. Local failure was defined as tumor progression/recurrence within the planning target volume. RESULTS: Tumor abutted the PBT in 31 %, esophagus in 31 %, great vessel in 65 %, and heart in 42 % of cases. 96 % of fractions were treated with reoptimized plan, necessary to meet OAR constraints (80 %) and/or target coverage (20 %). Median follow-up was 19 months (27 months among surviving patients). Local control (LC) was 96 % at 1-year and 90 % at 2-years (total 2/26 local failure). 23 % had G2 acute toxicities (esophagitis, dysphagia, anorexia, nausea) and one (4 %) had G3 acute radiation dermatitis. There were no G4-5 acute toxicities. There was no symptomatic pneumonitis and no G2 + late toxicities. CONCLUSION: Isotoxic 5-fraction SMART resulted in high rates of LC and minimal toxicity. This approach may widen the therapeutic window for high-risk oligoprogressive/oligometastatic thoracic tumors.
Assuntos
Neoplasias Pulmonares , Lesões por Radiação , Radiocirurgia , Neoplasias Torácicas , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Recidiva Local de Neoplasia , Radiocirurgia/métodos , Neoplasias Torácicas/radioterapia , Imageamento por Ressonância Magnética/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patologiaRESUMO
Background: The introduction of magnetic resonance (MR)-guided radiation treatment planning has opened a new space for theranostic nanoparticles to reduce acute toxicity while improving local control. In this work, second-generation AGuIX® nanoparticles (AGuIX-Bi) are synthesized and validated. AGuIX-Bi are shown to maintain MR positive contrast while further amplifying the radiation dose by the replacement of some Gd3+ cations with higher Z Bi3+. These next-generation nanoparticles are based on the AGuIX® platform, which is currently being evaluated in multiple Phase II clinical trials in combination with radiotherapy. Methods: In this clinically scalable methodology, AGuIX® is used as an initial chelation platform to exchange Gd3+ for Bi3+. AGuIX-Bi nanoparticles are synthesized with three ratios of Gd/Bi, each maintaining MR contrast while further amplifying radiation dose relative to Bi3+. Safety, efficacy, and theranostic potential of the nanoparticles were evaluated in vitro and in vivo in a human non-small cell lung cancer model. Results: We demonstrated that increasing Bi3+ in the nanoparticles is associated with more DNA damage and improves in vivo efficacy with a statistically significant delay in tumor growth and 33% complete regression for the largest Bi/Gd ratio tested. The addition of Bi3+ by our synthetic method leads to nanoparticles that present slightly altered pharmacokinetics and lengthening of the period of high tumor accumulation with no observed evidence of toxicity. Conclusions: We confirmed the safety and enhanced efficacy of AGuIX-Bi with radiation therapy at the selected ratio of 30Gd/70Bi. These results provide crucial evidence towards patient translation.
Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Nanopartículas , Humanos , Medicina de Precisão , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Doses de Radiação , Nanomedicina Teranóstica/métodosRESUMO
PURPOSE: The role of biliary stents in image-guided localization for pancreatic cancer has been inconclusive. To date, stent accuracy has been largely evaluated against implanted fiducials on cone beam computed tomography. We aim to use magnetic resonance (MR) soft tissue as a direct reference to examine the geometric and dosimetric impacts of stent-based localization on the newly available MR linear accelerator. METHODS: Thirty pancreatic cancer patients (132 fractions) treated on our MR linear accelerator were identified to have a biliary stent. In our standard adaptive workflow, patients were set up to the target using soft tissue for image registration and structures were re-contoured on daily MR images. The original plan was then projected on treatment anatomy and dose predicted, followed by plan re-optimization and treatment delivery. These online predicted plans were soft tissue-based and served as reference plans. Retrospective image registration to the stent was performed offline to simulate stent-based localization and the magnitude of shifts was taken as the geometric accuracy of stent localization. New predicted plans were generated based on stent-alignment for dosimetric comparison. RESULTS: Shifts were within 3 mm for 90% of the cases (mean = 1.5 mm); however, larger shifts up to 7.2 mm were observed. Average PTV coverage dropped by 1.1% with a maximum drop of 26.8%. The mean increase in V35Gy was 0.15, 0.05, 0.02, and 0.02 cc for duodenum, stomach, small bowel and large bowel, respectively. Stent alignment was significantly worse for all metrics except for small bowel (p = 0.07). CONCLUSIONS: Overall discrepancy between stent- and soft tissue-alignment was modest; however, large discrepancies were observed for select cases. While PTV coverage loss may be compensated for by using a larger margin, the increase in dose to gastrointestinal organs at risk may limit the role of biliary stents in image-guided localization.
Assuntos
Neoplasias Pancreáticas , Radiocirurgia , Radioterapia Guiada por Imagem , Humanos , Radiocirurgia/métodos , Estudos Retrospectivos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/cirurgia , Stents , Espectroscopia de Ressonância Magnética , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem/métodos , Neoplasias PancreáticasRESUMO
Our study aimed to elucidate the function of IMP U3 small nucleolar ribonucleoprotein 4 (IMP4) in lung adenocarcinoma (LUAD) and its potential molecular mechanisms. Cell counting kit-8, 5-ethynyl-20-deoxyuridine, flow cytometry, wound healing, and transwell assays were performed to examine the biological behaviour of LUAD cells. mRNA and protein expression levels were determined using quantitative real-time PCR, Western blotting, and immunohistochemistry. In addition, a mouse tumour xenograft model was used to evaluate the role of IMP4 in tumour progression. Furthermore, glycolysis-related indicators were measured. The levels of IMP4 were up-regulated in both human LUAD tissues and cells. IMP4 silencing significantly suppressed proliferation, migration, invasion, and glycolysis; promoted apoptosis; and induced cell cycle arrest in LUAD cells. IMP4 silencing also inactivated the extracellular signal-regulated kinase (ERK) pathway. Moreover, rescue experiments demonstrated that the function of LUAD cells induced by IMP4 overexpression could be reversed by treatment with an ERK pathway inhibitor (SCH772984). In vivo experiments further verified that IMP4 silencing repressed the growth of subcutaneous tumours and glycolysis. IMP4 silencing suppressed the malignancy of LUAD by inactivating ERK signalling.
RESUMO
Current MRI-guided adaptive radiotherapy (MRgART) workflows require fraction-specific electron and/or mass density maps, which are created by deformable image registration (DIR) between the simulation CT images and daily MR images. Manual density overrides may also be needed where DIR-produced results are inaccurate. This approach slows the adaptive radiotherapy workflow and introduces additional dosimetric uncertainties, especially in the presence of the magnetic field. This study investigated a method based on a conditional generative adversarial network (cGAN) with a multi-planar method to generate synthetic CT images from low-field MR images to improve efficiency in MRgART workflows for prostate cancer. Fifty-seven male patients, who received MRI-guided radiation therapy to the pelvis using the ViewRay MRIdian Linac, were selected. Forty-five cases were randomly assigned to the training cohort with the remaining twelve cases assigned to the validation/testing cohort. All patient datasets had a semi-paired DIR-deformed CT-sim image and 0.35T MR image acquired using a true fast imaging with steady-state precession (TrueFISP) sequence. Synthetic CT images were compared with deformed CT images to evaluate image quality and dosimetric accuracy. To evaluate the dosimetric accuracy of this method, clinical plans were recalculated on synthetic CT images in the MRIdian treatment planning system. Dose volume histograms for planning target volumes (PTVs) and organs-at-risk (OARs) and dose distributions using gamma analyses were evaluated. The mean-absolute-errors (MAEs) in CT numbers were 30.1 ± 4.2 HU, 19.6 ± 2.3 HU and 158.5 ± 26.0 HU for the whole pelvis, soft tissue, and bone, respectively. The peak signal-to-noise ratio was 35.2 ± 1.7 and the structural index similarity measure was 0.9758 ± 0.0035. The dosimetric difference was on average less than 1% for all PTV and OAR metrics. Plans showed good agreement with gamma pass rates of 99% and 99.9% for 1%/1 mm and 2%/2 mm, respectively. Our study demonstrates the potential of using synthetic CT images created with a multi-planar cGAN method from 0.35T MRI TrueFISP images for the MRgART treatment of prostate radiotherapy. Future work will validate the method in a large cohort of patients and investigate the limitations of the method in the adaptive workflow.
RESUMO
Background: The effects and mechanism of 6-pyruvoyl-tetrahydropterin synthase (PTS) on lung adenocarcinoma (LUAD) were studied in LUAD cells and mice with subcutaneously transplanted tumors. Methods: PTS level in tissues and cells was tested by immunohistochemistry, western blot, and quantitative real-time polymerase chain reaction (qRT-PCR). The impacts of PTS on cell viability, proliferation, apoptosis, invasion, and migration were determined by Cell Counting Kit-8 (CCK-8), colony formation assay, flow cytometry, transwell assay, and wound healing assay, respectively. The Cancer Genome Atlas (TCGA) analysis and dual luciferase assay were conducted to predict and verify the relationship between PTS and activating transcription factor 4 (ATF4). A mouse model was established by subcutaneous injection with cancer cells. Tumor volume was calculated as V = ab2/2. Ki67 and terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining were used to measure cell proliferation and apoptosis in tumors. Results: PTS was highly expressed in LUAD. Higher PTS level was correlated with late clinical stages and poor survival of patients. Down-regulation of PTS inhibited the viability and proliferation and induced apoptosis of LUAD cells. PTS was activated by ATF4, and up-regulation of ATF4 reversed the inhibitory effect of PTS silencing on LUAD cells. Silencing of PTS inhibited the Wnt pathway. Down-regulation of PTS inhibited tumor growth in mice. Conclusions: PTS was highly expressed in LUAD. PTS was activated by ATF4 and promoted LUAD development via the Wnt pathway.
RESUMO
OBJECTIVE: Lung cancer is a malignancy with high a mortality rate that threatens human health. This study is aimed to explore the correlation among the triglyceride/high-density lipoprotein ratio (TG/HDL-C), non-high-density lipoprotein/high-density lipoprotein ratio (non-HDL-C/HDL-C) and survival of patients with non-small cell lung cancer (NSCLC) undergoing video-associated thoracic surgery (VATS). METHODS: This retrospective study analyzed 284 patients with NSCLC who underwent VATS at Hebei General Hospital, Shijiazhuang, China. The time-dependent receiver operating characteristic curve was used to determine the optimal cutoff value and evaluate the area under the curve. Kaplan-Meier and Cox regression analyses were performed to determine the prognostic effect. RESULTS: The median overall survival (OS) was 46 months. Patients with low TG/HDL-C and low non-HDL-C/HDL-C had a longer OS. The low non-HDL-C/HDL-C group showed a longer mean survival time (59.00 vs. 52.35 months). Multivariate analysis revealed that TG/HDL-C and non-HDL-C/HDL-C were significantly correlated with OS. CONCLUSIONS: TG/HDL-C and non-HDL-C/HDL-C are associated with the prognosis of patients with NSCLC who received VATS. Preoperative serum TG/HDL-C and non-HDL-C/HDL-C may be effective independent prognostic factors for predicting the outcomes of patients with NSCLC.
Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/cirurgia , HDL-Colesterol , Humanos , Lipoproteínas HDL , Neoplasias Pulmonares/cirurgia , Prognóstico , Estudos Retrospectivos , TriglicerídeosRESUMO
Purpose: Stereotactic magnetic resonance (MR)-guided adaptive radiation therapy (SMART) for prostate cancer allows for MR-based contouring, real-time MR motion management, and daily plan adaptation. The clinical and dosimetric benefits associated with prostate SMART remain largely unknown. Methods and Materials: A phase 1 trial of prostate SMART was conducted with primary endpoints of safety and feasibility. An additional cohort of patients similarly treated with prostate SMART were included in the analysis. SMART was delivered to 36.25 Gy in 5 fractions to the prostate ± seminal vesicles using the MRIdian linear accelerator system (ViewRay, Inc). Rates of urinary and gastrointestinal toxic effects and patient-reported outcome measures were assessed. Dosimetric analyses were conducted to evaluate the specific benefits of daily plan adaptation. Results: The cohort included 22 patients (n = 10 phase 1, n = 12 supplemental) treated in 110 fractions. Median follow-up was 7.9 months. Acute grade 2 urinary and gastrointestinal toxic effects were observed in 22.7% and 4.5%, respectively, and 4.5% and 0%, respectively, at last follow-up. No grade 3+ events were observed. Expanded Prostate Cancer Index-26 urinary obstructive scores decreased during SMART (mean, 9.3 points; P = .03) and returned to baseline by 3 months. No other significant changes in patient-reported outcome measures were observed. One-hundred percent of fractions required plan adaptation owing to exceeding organ-at-risk metrics (68%) or suboptimal target coverage (33%) resulting from anatomic changes. Minimum acceptable planning target volume, rectal, bladder, and urethra/bladder neck metrics were violated in 24%, 20%, 24%, and 33% of predicted plans, respectively; 0% of reoptimized plans violated metrics. Underlying causes for deficient dosimetry before reoptimization included changes in bladder filling, seminal vesicle position, prostate volume (median 4.7% increase by fraction 3; range, 0%-56%), and hotspots shifting into urethra/bladder neck. Conclusions: Prostate SMART results in low risk of acute toxic effects with improvements in target and organ-at-risk dosimetry. The clinical benefits resulting from daily plan adaptation, including urethra/bladder neck protection, warrant further investigation.
RESUMO
Background: The routine clinical nutritional and inflammatory indicators such as serum albumin, total cholesterol and lymphocytes have been widely investigated in the prognosis of small cell lung cancer (SCLC). The Naples prognostic score (NPS), based on nutritional and inflammatory status, has been identified as a prognostic impactor in several malignancies. However, the prognostic role of NPS in SCLC has not been elucidated. This study aims to evaluate the prognostic effect of NPS in SCLC patients. Patients and Methods: Patients with SCLC were recruited at Hebei General Hospital between April 2015 and August 2021. Pretreatment clinical and laboratory data were obtained. Participants were assigned into three groups according to NPS (group 0: NPS=0, group 1: NPS=1 or 2, group 2: NPS=3 or 4). Kaplan-Meier and Cox regression analysis were performed to assess the prognostic significance of NPS. The RMS package in R software was used to draw the nomogram predictive model. Results: A total of 128 patients were enrolled. The median progression-free survival (PFS) and overall survival (OS) was 7.2 and 12.3 months, respectively. The median PFS and OS was 12.3 vs 19.8 months, 7.6 vs 14.1 months and 6.0 vs 8.45 months for the three groups respectively. There were significant differences in both OS and FPS among the three groups. Survival analysis showed that NPS was significantly correlated with both OS and PFS (P<0.05). Lower NPS is associated with longer OS and PFS. Multivariate analysis showed that NPS has an independent prognostic impact on OS (P<0.05). The nomogram predictive model showed that NPS has good predictive power for survival rates. Conclusion: NPS is an independent prognostic factor for OS in SCLC patients. Low NPS may predict longer OS. Therefore NPS plays a vital role in the nomogram predictive model of survival rates in SCLC patients.
RESUMO
PURPOSE: Stereotactic body radiation therapy can be an effective treatment for oligometastases. However, safe delivery of ablative radiation is frequently limited by the proximity of mobile organs sensitive to high radiation doses. The goal of this study was to determine the feasibility, safety, and disease control outcomes of stereotactic magnetic resonance-guided adaptive radiation therapy (SMART) in patients with abdominopelvic oligometastases. METHODS AND MATERIALS: We identified 101 patients with abdominopelvic oligometastases, including 20 patients enrolled on phase 1 protocols, who were consecutively treated with SMART on a 0.35T magnetic resonance linear accelerator (MR linac) at a single institution from October 2019 to September 2021. Local control and overall survival were analyzed using the Kaplan-Meier method. RESULTS: Overall, 114 tumors were treated. The most common histology was prostate adenocarcinoma (60 tumors [53.5%]), and 65 sites (57.0%) were centered in the pelvis. Ninety-one sites (79.8%) were treated to 8 Gy × 5, and 49 (43.0%) were treated with breath-hold respiratory gating. Online adaptation resulted in a clinically significant improvement in coverage or organ sparing in 86.6% of delivered fractions. The median time required for adaptation was 24 minutes, and the median time in the treatment room was 58 minutes. With median follow-up of 11.4 months, the 12-month local control was 93% and was higher for prostate adenocarcinoma versus other histologies (100% vs 84%; P = .009). The 12-month overall survival was 96% and was higher for prostate adenocarcinoma versus other histologies (100% vs 91%; P = .046). Three patients (3.0%) developed grade 3 toxic effects (colonic hemorrhage at 3.4 months and urinary tract obstructions at 10.1 and 18.4 months, respectively). CONCLUSIONS: In this study, SMART was feasible, safe, and effective for delivering ablative radiation therapy to abdominopelvic metastases. Adaptive planning was necessary in the large majority of cases. The advantages of SMART warrant its further investigation as a standard option for the treatment of abdominopelvic oligometastases.
Assuntos
Adenocarcinoma , Neoplasias da Próstata , Radiocirurgia , Masculino , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Neoplasias da Próstata/radioterapia , Espectroscopia de Ressonância Magnética , Adenocarcinoma/radioterapiaRESUMO
Spent carbon cathode (SCC) produced in the process of aluminum electrolysis is a typical toxic and hazardous solid waste. Therefore, the harmless treatment of SCC is extremely important for the green development of aluminum electrolysis industry. In this paper, the microwave-assisted high-temperature roasting technology was developed to remove fluorides in SCC for recycling of this cathode. The melting point, dielectric parameter, crystalline structure, surface chemical property, elemental composition, morphological structure, carbon graphitization and surface area were characterized using thermogravimetric analysis and differential scanning calorimetry, high-temperature composite conductivity analyzer, X-ray diffraction, X-ray fluorescence, X-ray photoelectron spectroscopy, scanning electronic microscopy, transmission electron microscopy, Raman spectroscopy and isothermal N2 adsorption-desorption method. The content of fluorides in raw and treated SCC was measured by ion activity meter. The results showed that the phase of sodium fluoride and cryolite would transform from solid to liquid when the temperature was higher than 1098.5 °C, and the SCC exhibited good performance on wave absorption with the action depth of 1 cm. The SCC was mainly composed of 57.94 wt% C, 14.23 wt% NaF, 1.80 wt%, CaF2, 15.06 wt% Na3AlF6, and 10.97 wt% Other. After treatment under microwave, the graphite carbon exhibited pitting structure and the fluorides could be effectively removed. In addition, the average layer spacing of graphite was increased from 0.34 to 0.36 nm. The defluorination of SCC could be enhanced with the increase of roasting temperature, which would attain 95.4% at 1500 °C. Compared with the traditional roasting method, the process under microwave showed more defects, which would provide a new guidance for the treatment and recycling of spent SCC.
Assuntos
Carbono , Micro-Ondas , Eletrodos , Reciclagem , TemperaturaRESUMO
OBJECTIVE: The advanced lung cancer inflammation index (ALI) predicts overall survival (OS) in patients with advanced lung cancer. However, few studies have tested ALI's prognostic effect in patients with non-small cell lung cancer (NSCLC) following video-assisted thoracic surgery (VATS), especially patients at stage III. This study investigated the relationship between ALI and outcomes of patients with NSCLC following VATS. METHODS: We retrospectively examined 339 patients with NSCLC who underwent VATS at Hebei General Hospital, China. Preoperative clinical and laboratory parameters were collected and analyzed. Optimal cutoff values of potential prognostic factors, including ALI, were determined. Kaplan-Meier and Cox regression analyses were used to determine each factor's prognostic value. RESULTS: The median OS was 31 months. The optimal cutoff value for ALI was 41.20. Patients with high ALI (≥41.20) displayed increased OS (33.87 vs. 30.24 months), higher survival rates, and milder clinical characteristics. Univariate and multivariate analyses showed a significant correlation between ALI and the prognosis of patients with NSCLC, including those at stage IIIA, who underwent VATS. CONCLUSIONS: Low ALI correlated with poor outcomes in patients with NSCLC following VATS. Preoperative ALI might be a potential prognostic biomarker for patients with NSCLC following VATS, including patients at stage IIIA.
Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Humanos , Inflamação , Neoplasias Pulmonares/cirurgia , Estudos Retrospectivos , Cirurgia Torácica VídeoassistidaRESUMO
Linac and MLC-based stereotactic radiosurgery (SRS) using single-isocenter-multiple-target (SIMT) VMAT has become increasingly popular in the management of multi-focal cranial metastases. However, significant geometrical and dosimetric challenges exist due to the typically small target volumes and in most cases, non-isocentric locations. To the best of our knowledge, there hasn't been a study in the optimization of MLC parameters, in the context of SIMT SRS, to ensure TPS calculation accuracy. In this work, we set out to optimize the dosimetric leaf gap (DLG) for the HD MLC installed on dedicated stereotactic Varian STx systems using a diverse group of 21 clinical SRS and SBRT plans. These plans featured a broad range of target sizes and target-to-isocenter distances that are typical of the stereotactic cases treated on these systems. Dose discrepancies between TPS calculations and verification measurements using a previously validated diode array Delta4 (ScandiDos) were minimized in a balanced manner to accommodate the variety of stereotactic plans. A DLG of 0.6 mm was found to be 'optimal' for the HD MLC and for the 'typical' plans treated on our STx systems. The finding was independently verified using commercially available 3D polymer gel dosimeter CrystalBallTM (MGS Research Inc.). 3D verification for 6 SIMT SRS plans, consisted of 5 to 15 targets, achieved an average gamma score of 97.3% (σ = 2.0%) on 3%/2 mm criteria with a cutoff isodose level of 20%. We further examined the practice of routine dosimetric verifications including the selection of appropriate detectors and optimal gamma parameters. We found that the commonly used standard 3%/3 mm criteria would have resulted in all but 4 (out of 2840) clinical plans achieving a gamma score of 95% or better, and therefore, losing sensitivity to detect potential dosimetric discrepancies. Based on the characteristics of stereotactic plans, a more stringent distance-to-agreement parameter is needed.
Assuntos
Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/cirurgia , Radiocirurgia/estatística & dados numéricos , Dosagem Radioterapêutica , Radioterapia/estatística & dados numéricos , Humanos , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Reprodutibilidade dos TestesRESUMO
There is a wide range in the reported photon tenth value distance (TVD) in the maze of high-energy linear accelerator vaults. In order to gain insight into the appropriate use of the TVD value during door design, we performed measurements of the photon dose in the maze of four vaults. In addition, our study represents the first to describe a scenario where an inner borated polyethylene (BPE) door for neutron shielding is installed in the maze downstream to Point A, the point on the maze centerline that is just visible from the isocenter. The measurements were made along the maze centerline at 1 m above the floor. In all cases, the accelerator operated at a nominal energy of 15 MV. Of the four vaults, three were equipped with an inner BPE door at a distance of 1.0-2.1 m downstream to Point A. The door was made of 10.16 cm (4â³) BPE sandwiched between two 0.635 cm (1/4â³) steel face plates. The photon dose in the maze without a BPE door decreases exponentially with a characteristic TVD of 6 m beyond a distance of 2.5 m from Point A. The presence of a BPE door in an identical vault not only reduces the photon intensity in the maze by about an order of magnitude, but also softens the energy spectrum with a shortened TVD of 4.7 m, significantly lessening the shielding burden at the outer maze entrance. In contrast to the common use of Point A as the reference point to specify distance, the photon dose in the maze with a BPE door located downstream to Point A can be satisfactorily described as exponential functions of the distance measured from the door, which shows good consistency among the three vaults of different room parameters.