Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Appl Clin Med Phys ; : e14463, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39138877

RESUMO

PURPOSE: This study investigated the use of surface guided radiotherapy (SGRT) in combination with a tomotherapy treatment mode using discrete delivery angles for deep inspiration breath hold (DIBH) treatments of breast cancer (bc). We aimed to assess the feasibility and dosimetric advantages of this approach. MATERIALS AND METHODS: We evaluated camera occlusion in the Radixact treatment system bore and the stability of DIBH signals during couch movement. The SGRT system's ability to maintain signal and surface image accuracy was analyzed at different depths within the bore. Dosimetric parameters were compared and measured for 20 left-sided bc patients receiving TomoDirect (TD) tangential radiotherapy in both DIBH and free breathing (FB). RESULTS: The SGRT system maintained surface coverage and precise DIBH-signal at depths up to 40 cm beyond the treatment center. Camera occlusion occurred in the clavicular and neck regions due to the patient's morphology and gantry geometry. Nonetheless, the system accurately detected respiratory motion for all measurements. The DIBH plans significantly (p < 0.001) reduced mean heart and left anterior descending artery (LAD) radiation doses by up to 40%, with a 50% reduction in near-maximum heart and LAD doses, respectively. No significant dosimetric differences between DIBH and FB were observed in other investigated parameters and volumes. CONCLUSIONS: Camera occlusion and couch movement minimally impacted the real-time surface image accuracy needed for DIBH treatments of bc. DIBH reduced heart and LAD radiation doses significantly compared to FB, indicating the feasibility and dosimetric benefits of combining these modalities.

2.
Int J Radiat Oncol Biol Phys ; 117(5): 1222-1231, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37423292

RESUMO

PURPOSE: Stereotactic body radiation therapy for tumors near the central airways implies high-grade toxic effects, as concluded from the HILUS trial. However, the small sample size and relatively few events limited the statistical power of the study. We therefore pooled data from the prospective HILUS trial with retrospective data from patients in the Nordic countries treated outside the prospective study to evaluate toxicity and risk factors for high-grade toxic effects. METHODS AND MATERIALS: All patients were treated with 56 Gy in 8 fractions. Tumors within 2 cm of the trachea, the mainstem bronchi, the intermediate bronchus, or the lobar bronchi were included. The primary endpoint was toxicity, and the secondary endpoints were local control and overall survival. Clinical and dosimetric risk factors were analyzed for treatment-related fatal toxicity in univariable and multivariable Cox regression analyses. RESULTS: Of 230 patients evaluated, grade 5 toxicity developed in 30 patients (13%), of whom 20 patients had fatal bronchopulmonary bleeding. The multivariable analysis revealed tumor compression of the tracheobronchial tree and maximum dose to the mainstem or intermediate bronchus as significant risk factors for grade 5 bleeding and grade 5 toxicity. The 3-year local control and overall survival rates were 84% (95% CI, 80%-90%) and 40% (95% CI, 34%-47%), respectively. CONCLUSIONS: Tumor compression of the tracheobronchial tree and high maximum dose to the mainstem or intermediate bronchus increase the risk of fatal toxicity after stereotactic body radiation therapy in 8 fractions for central lung tumors. Similar dose constraints should be applied to the intermediate bronchus as to the mainstem bronchi.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Neoplasias Pulmonares/patologia , Brônquios/efeitos da radiação , Fatores de Risco , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos
3.
Eur J Haematol ; 107(4): 393-407, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34107104

RESUMO

OBJECTIVES: Total body irradiation (TBI) is commonly used prior to hematopoietic stem cell transplantation (HSCT) in myeloablative conditioning regimens. However, TBI may be replaced by total marrow irradiation (TMI) at centres with access to Helical TomoTherapy, a modality that has the advantage of delivering intensity-modulated radiotherapy to long targets such as the entire bone marrow compartment. Toxicity after organ sparing TMI prior to HSCT has not previously been reported compared to TBI or with regard to engraftment data. METHODS: We conducted a prospective observational study on 37 patients that received organ sparing TMI prior to HSCT and compared this cohort to retrospective data on 33 patients that received TBI prior to HSCT. RESULTS: The 1-year graft-versus-host disease-free, relapse-free survival (GRFS) was 67.5% for all patients treated with TMI and 80.5% for patients with matched unrelated donor and treated with TMI, which was a significant difference from historical data on TBI patients with a hazard ratio of 0.45 (P = .03) and 0.24 (P < .01). Engraftment with a platelet count over 20 [K/µL] and 50 [K/µL] was significantly shorter for the TMI group, and neutrophil recovery was satisfactory in both treatment cohorts. There was generally a low occurrence of other treatment-related toxicities. CONCLUSIONS: Despite small cohorts, some significant differences were found; TMI as part of the myeloablative conditioning yields a high 1-year GRFS, fast and robust engraftment, and low occurrence of acute toxicity.


Assuntos
Doença Enxerto-Hospedeiro/patologia , Transplante de Células-Tronco Hematopoéticas/métodos , Síndromes Mielodisplásicas/terapia , Transtornos Mieloproliferativos/terapia , Radioterapia de Intensidade Modulada/métodos , Irradiação Corporal Total/métodos , Adolescente , Adulto , Medula Óssea/efeitos dos fármacos , Medula Óssea/patologia , Medula Óssea/efeitos da radiação , Criança , Pré-Escolar , Feminino , Sobrevivência de Enxerto/fisiologia , Doença Enxerto-Hospedeiro/diagnóstico , Doença Enxerto-Hospedeiro/imunologia , Humanos , Masculino , Pessoa de Meia-Idade , Agonistas Mieloablativos/uso terapêutico , Síndromes Mielodisplásicas/mortalidade , Síndromes Mielodisplásicas/patologia , Transtornos Mieloproliferativos/mortalidade , Transtornos Mieloproliferativos/patologia , Estudos Prospectivos , Radioterapia de Intensidade Modulada/mortalidade , Análise de Sobrevida , Condicionamento Pré-Transplante/métodos , Transplante Homólogo , Irradiação Corporal Total/mortalidade
4.
J Thorac Oncol ; 16(7): 1200-1210, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33823286

RESUMO

INTRODUCTION: Stereotactic body radiation therapy of thoracic tumors close to the central airways implies risk of severe toxicity. We report a prospective multicenter phase 2 trial for tumors located less than or equal to 1 cm from the proximal bronchial tree with primary end point of local control and secondary end point of toxicity. METHODS: Stereotactic body radiation therapy with 7 Gy × 8 was prescribed to the 67% isodose encompassing the planning target volume. The patients were stratified to group A (tumors ≤ 1 cm from the main bronchi and trachea) or group B (all other tumors). Risk factors for treatment-related death were tested in univariate analysis, and a logistic regression model was developed for fatal bronchopulmonary bleeding versus dose to the main bronchi and trachea. RESULTS: A total of 65 patients (group A/group B, n = 39/26) were evaluated. The median distance between the tumor and the proximal bronchial tree was 0 mm (0-10 mm). The 2-year local control was 83%. Grade 3 to 5 toxicity was noted in 22 patients, including 10 cases of treatment-related death (bronchopulmonary hemorrhage, n = 8; pneumonitis, n = 1; fistula, n = 1). Dose to the combined structure main bronchi and trachea and tumor distance to the main bronchi were important risk factors. Dose modeling revealed minimum dose to the "hottest" 0.2 cc to the structure main bronchi and trachea as the strongest predictor for lethal bronchopulmonary hemorrhage. CONCLUSIONS: On the basis of the presented data, 7 Gy × 8, prescribed to the planning target volume-encompassing isodose, should not be used for tumors located within 1 cm from the main bronchi and trachea. Group B-type tumors may be considered for the treatment on the basis of an individual risk-benefit assessment and a maximum dose to the main bronchi and trachea in the order of 70 to 80 Gy (equivalent dose in 2 Gy fractions).


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Fracionamento da Dose de Radiação , Humanos , Pulmão , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Estudos Prospectivos , Radiocirurgia/efeitos adversos , Dosagem Radioterapêutica
5.
J Appl Clin Med Phys ; 21(8): 139-148, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32592288

RESUMO

PURPOSE: In this study, we have quantified the setup deviation and time gain when using fast surface scanning for daily setup/positioning with weekly megavoltage computed tomography (MVCT) and compared it to daily MVCT. METHODS: A total of 16 835 treatment fractions were analyzed, treated, and positioned using our TomoTherapy HD (Accuray Inc., Madison, USA) installed with a Sentinel optical surface scanning system (C-RAD Positioning AB, Uppsala, Sweden). Patients were positioned using in-room lasers, surface scanning and MVCT for the first three fractions. For the remaining fractions, in-room laser was used for setup followed by daily surface scanning with MVCT once weekly. The three-dimensional (3D) setup correction for surface scanning was evaluated from the registration between MVCT and the planning CT. The setup correction vector for the in-room lasers was assessed from the surface scanning and the MVCT to planning CT registration. The imaging time was evaluated as the time from imaging start to beam-on. RESULTS: We analyzed 894 TomoTherapy treatment plans from 2012 to 2018. Of all the treatment fractions performed with surface scanning, 90 % of the residual errors were within 2.3 mm for CNS (N = 284), 2.9 mm for H&N (N = 254), 8.7 mm for thorax (N = 144) and 10.9 for abdomen (N = 134) patients. The difference in residual error between surface scanning and positioning with in-room lasers was significant (P < 0.005) for all sites. The imaging time was assessed as total imaging time per treatment plan, modality, and treatment site and found that surface scanning significantly reduced patient on-couch time compared to MVCT for all treatment sites (P < 0.005). CONCLUSIONS: The results indicate that daily surface scanning with weekly MVCT can be used with the current target margins for H&N, CNS, and thorax, with reduced imaging time.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Estudos Retrospectivos , Suécia
6.
Radiat Oncol ; 15(1): 149, 2020 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-32522233

RESUMO

BACKGROUND: Optimal alignment is of utmost importance when treating pediatric patients with craniospinal irradiation (CSI), especially with regards to field junctions and multiple isocenters and techniques applying high dose gradients. Here, we investigated the setup errors and uncertainties for pediatric CSI using different setup verification protocols. METHODS: A total of 38 pediatric patients treated with CSI were identified for whom treatment records and setup images were available. The setup images were registered retrospectively to the reference image using an automated tool and matching on bony anatomy, subsequently, the impact of different correction protocols was simulated. RESULTS: For an action-level (AL)-protocol and a non-action level (NAL)-protocol, the translational residual setup error can be as large as 24 mm for an individual patient during a single fraction, and the rotational error as large as 6.1°. With daily IGRT, the maximum setup errors were reduced to 1 mm translational and 5.4° rotational versus 1 mm translational and 2.4° rotational for 3- and 6- degrees of freedom (DoF) couch shifts, respectively. With a daily 6-DoF IGRT protocol for a wide field junction irradiation technique, the residual positioning uncertainty was below 1 mm and 1° for translational and rotational directions, respectively. The largest rotational uncertainty was found for the patients' roll even though this was the least common type of rotational error, while the largest translational uncertainty was found in the patients' anterior-posterior-axis. CONCLUSIONS: These results allow for informed margin calculation and robust optimization of treatments. Daily IGRT is the superior choice for setup of pediatric patients treated with CSI, although centers that do not have this option could use the results presented here to improve their margins and uncertainty estimates for a more accurate treatment alignment.


Assuntos
Neoplasias do Sistema Nervoso Central/radioterapia , Radiação Cranioespinal/métodos , Erros de Configuração em Radioterapia , Radioterapia Guiada por Imagem/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Posicionamento do Paciente/métodos , Incerteza , Adulto Jovem
7.
J Appl Clin Med Phys ; 20(5): 44-54, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31033159

RESUMO

Mycosis fungoides is a disease with manifestation of the skin that has traditionally been treated with electron therapy. In this paper, we present a method of treating the entire skin with megavoltage photons using helical tomotherapy (HT), verified through a phantom study and clinical dosimetric data from our first two treated patients. A whole body phantom was fitted with a wetsuit as bolus, and scanned with computer tomography. We accounted for variations in daily setup using virtual bolus in the treatment plan optimization. Positioning robustness was tested by moving the phantom, and recalculating the dose at different positions. Patient treatments were verified with in vivo film dosimetry and dose reconstruction from daily imaging. Reconstruction of the actual delivered dose to the patients showed similar target dose as the robustness test of the phantom shifted 10 mm in all directions, indicating an appropriate approximation of the anticipated setup variation. In vivo film measurements agreed well with the calculated dose confirming the choice of both virtual and physical bolus parameters. Despite the complexity of the treatment, HT was shown to be a robust and feasible technique for total skin irradiation. We believe that this technique can provide a viable option for Tomotherapy centers without electron beam capability.


Assuntos
Micose Fungoide/radioterapia , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Cutâneas/radioterapia , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Prognóstico , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X/métodos
8.
Phys Med ; 60: 162-167, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31000078

RESUMO

Total Marrow Irradiation (TMI) with Helical Tomotherapy is a radiotherapy treatment technique that targets bone marrow and sanctuary sites prior to stem cell or bone marrow transplantation (SCT/BMT). TMI is a complex procedure that involves several critical steps that all need to be carefully addressed for a successful implementation, such as dose homogeneity in field junctions, choice of target margins, integrity of treatment and back-up planning. In this work we present our solution for a robust and reproducible workflow throughout the treatment chain and data for twenty-three patients treated to date. MATERIAL & METHODS: Patients were immobilized in a whole body vacuum cushion and thermoplastic mask. CT-scanning and treatment were performed in two parts with field matching at the upper thigh. Target consisted of marrow containing bone and sanctuary sites. Lungs, kidneys, bowel, heart and liver were defined as organs at risk (OAR). A fast surface scanning system was used to position parts of the body not covered by the imaging system (MVCT) as well as to reduce treatment time. RESULTS: All patients completed their treatment and could proceed with SCT/BMT. Doses to OARs were significantly reduced and target dose homogeneity was improved compared to TBI. Robustness tests performed on field matching and patient positioning support that the field junction technique is adequate. Replacing MVCT with optical surface scanning reduced the treatment time by 25 min per fraction. CONCLUSION: The methodology presented here has shown to provide a safe, robust and reproducible treatment for Total Marrow Irradiation using Tomotherapy.


Assuntos
Medula Óssea , Radioterapia de Intensidade Modulada/métodos , Adolescente , Adulto , Medula Óssea/efeitos da radiação , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/terapia , Órgãos em Risco , Equipe de Assistência ao Paciente , Posicionamento do Paciente/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/instrumentação , Transplante de Células-Tronco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA