Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
ACS Sens ; 8(1): 3-11, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36574491

RESUMO

Chemiluminescent molecules which emit light in response to a chemical reaction are powerful tools for the detection and measurement of biological analytes and enable the understanding of complex biochemical processes in living systems. Triggerable chemiluminescent 1,2-dioxetanes have been studied and tuned over the past decades to advance quantitative measurement of biological analytes and molecular imaging in live cells and animals. A crucial determinant of success for these 1,2-dioxetane based sensors is their chemical structure, which can be manipulated to achieve desired chemical properties. In this Perspective, we survey the structural space of triggerable 1,2-dioxetane and assess how their design features affect chemiluminescence properties including quantum yield, emission wavelength, and decomposition kinetics. Based on this appraisal, we identify some structural modifications of 1,2-dioxetanes that are ripe for exploration in the context of chemiluminescent biological sensors.


Assuntos
Compostos Heterocíclicos , Compostos Heterocíclicos/química , Medições Luminescentes , Compostos Heterocíclicos com 1 Anel , Luminescência
2.
ACS Cent Sci ; 8(1): 67-76, 2022 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-35106374

RESUMO

Patterning chemical reactivity with a high spatiotemporal resolution and chemical versatility is critically important for advancing revolutionary emergent technologies, including nanorobotics, bioprinting, and photopharmacology. Current methods are complex and costly, necessitating novel techniques that are easy to use and compatible with a wide range of chemical functionalities. This study reports the development of a digital light processing (DLP) fluorescence microscope that enables the structuring of visible light (465-625 nm) for high-resolution photochemical patterning and simultaneous fluorescence imaging of patterned samples. A range of visible-light-driven photochemical systems, including thiol-ene photoclick reactions, Wolff rearrangements of diazoketones, and photopolymerizations, are shown to be compatible with this system. Patterning the chemical functionality onto microscopic polymer beads and films is accomplished with photographic quality and resolutions as high as 2.1 µm for Wolff rearrangement chemistry and 5 µm for thiol-ene chemistry. Photoactivation of molecules in living cells is demonstrated with single-cell resolution, and microscale 3D printing is achieved using a polymer resin with a 20 µm xy-resolution and a 100 µm z-resolution. Altogether, this work debuts a powerful and easy-to-use platform that will facilitate next-generation nanorobotic, 3D printing, and metamaterial technologies.

3.
J Mater Chem A Mater ; 35: 19698-19704, 2021 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-34721878

RESUMO

The controlled introduction of defects into MOFs is a powerful strategy to induce new physiochemical properties and improve their performance for target applications. Herein, we present a new strategy for defect formation and amorphization of the canonical MOF-74 frameworks based on fine-tuning of adsorbate-framework interactions in the metal congener, hence introducing structural defects. Specifically, we demonstrate that controlled interactions between the MOF and bidentate ligands adsorbed in the pores initiates defect formation and eventual amorphization of the crystal. These structural features unlock properties that are otherwise absent in the ordered framework, such as broad-band fluorescence. The ability to introduce defects by adsorbate-framework interactions, coupled with the inherent tunability and modularity of these structures, provides a new route for the synthesis of diverse heterogeneous and hybrid materials.

4.
Acc Chem Res ; 54(13): 2844-2857, 2021 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-34110136

RESUMO

Chemiluminescence is a fascinating phenomenon that evolved in nature and has been harnessed by chemists in diverse ways to improve life. This Account tells the story of our research group's efforts to formulate and manifest spiroadamantane 1,2-dioxetanes with triggerable chemiluminescence for imaging and monitoring important reactive analytes in living cells, animals, and human clinical samples. Analytes like reactive sulfur, oxygen and nitrogen species, as well as pH and hypoxia can be indicators of cellular function or dysfunction and are often implicated in the causes and effects of disease. We begin with a foundation in binding-based and activity-based fluorescence imaging that has provided transformative tools for understanding biological systems. The intense light sources required for fluorescence excitation, however, introduce autofluorescence and light scattering that reduces sensitivity and complicates in vivo imaging. Our work and the work of our collaborators were the first to demonstrate that spiroadamantane 1,2-dioxetanes had sufficient brightness and biological compatibility for in vivo imaging of enzyme activity and reactive analytes like hydrogen sulfide (H2S) inside of living mice. This launched an era of renewed interest in 1,2-dioxetanes that has resulted in a plethora of new chemiluminescence imaging agents developed by groups around the world. Our own research group focused its efforts on reactive sulfur, oxygen, and nitrogen species, pH, and hypoxia, resulting in a large family of bright chemiluminescent 1,2-dioxetanes validated for cell monitoring and in vivo imaging. These chemiluminescent probes feature low background and high sensitivity that have been proven quite useful for studying signaling, for example, the generation of peroxynitrite (ONOO-) in cellular models of immune function and phagocytosis. This high sensitivity has also enabled real-time quantitative reporting of oxygen-dependent enzyme activity and hypoxia in living cells and tumor xenograft models. We reported some of the first ratiometric chemiluminescent 1,2-dioxetane systems for imaging pH and have introduced a powerful kinetics-based approach for quantification of reactive species like azanone (nitroxyl, HNO) and enzyme activity in living cells. These tools have been applied to untangle complex signaling pathways of peroxynitrite production in radiation therapy and as substrates in a split esterase system to provide an enzyme/substrate pair to rival luciferase/luciferin. Furthermore, we have pushed chemiluminescence toward commercialization and clinical translation by demonstrating the ability to monitor airway hydrogen peroxide in the exhaled breath of asthma patients using transiently produced chemiluminescent 1,2-dioxetanedione intermediates. This body of work shows the powerful possibilities that can emerge when working at the interface of light and chemistry, and we hope that it will inspire future scientists to seek out ever brighter and more illuminating ideas.


Assuntos
Adamantano/análogos & derivados , Compostos Heterocíclicos com 1 Anel/química , Substâncias Luminescentes/química , Compostos de Espiro/química , Adamantano/síntese química , Animais , Compostos Heterocíclicos com 1 Anel/síntese química , Humanos , Concentração de Íons de Hidrogênio , Hipóxia/diagnóstico por imagem , Luminescência , Substâncias Luminescentes/síntese química , Neoplasias/diagnóstico por imagem , Imagem Óptica/métodos , Compostos de Espiro/síntese química , beta-Galactosidase/metabolismo
5.
ACS Sens ; 5(9): 2925-2932, 2020 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-32829636

RESUMO

Regulation of physiological pH is integral for proper whole body and cellular function, and disruptions in pH homeostasis can be both a cause and effect of disease. In light of this, many methods have been developed to monitor pH in cells and animals. In this study, we report a chemiluminescence resonance energy transfer (CRET) probe Ratio-pHCL-1, composed of an acrylamide 1,2-dioxetane chemiluminescent scaffold with an appended pH-sensitive carbofluorescein fluorophore. The probe provides an accurate measurement of pH between 6.8 and 8.4, making it a viable tool for measuring pH in biological systems. Further, its ratiometric output is independent of confounding variables. Quantification of pH can be accomplished using both common luminescence spectroscopy and advanced optical imaging methods. Using an IVIS Spectrum, pH can be measured through tissue with Ratio-pHCL-1, which is shown in vitro and calibrated in sacrificed mouse models. Intraperitoneal injections of Ratio-pHCL-1 into live mice show high photon outputs and consistent increases in the flux ratio when measured at pH 6, 7, and 8.


Assuntos
Compostos Heterocíclicos com 1 Anel , Luminescência , Animais , Transferência de Energia , Concentração de Íons de Hidrogênio , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA