Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
J Nucl Med ; 65(5): 688-692, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38514085

RESUMO

Small functional pituitary tumors can cause severely disabling symptoms and early death. The gold standard diagnostic approach includes laboratory tests and MRI, with or without inferior petrosal sinus sampling (IPSS). In up to 40% of patients, however, the source of excess hormone production remains unidentified or uncertain. This excludes patients from surgical, Gamma Knife, and CyberKnife therapy and adversely affects overall cure rates. We here assess the diagnostic yield of O-(2-[18F]fluoroethyl)-l-tyrosine ([18F]FET) PET/MRI for detection of small functional pituitary tumors in these patients. Methods: This retrospective analysis included patients with Cushing disease (CD) but prior negative or inconclusive MRI results who underwent [18F]FET PET/MRI between February 1, 2021, and December 1, 2022. PET/MR images and MR images alone were evaluated by experienced nuclear radiologists, neuroradiologists, or radiologists. Postoperative tissue analysis (when performed) was used as a reference standard to assess diagnostic metrics (i.e., sensitivity and positive predictive value). Results were also compared with previously obtained MR images, preceding IPSS, and clinical or biochemical follow-up. Results: Twenty-two patients (68% female; mean age ± SD, 48 ± 15 y; range, 24-68 y) were scanned. All patients showed a clear metabolic focus on [18F]FET PET, whereas reading of the MRI alone yielded a suspected lesion in only 50%. Fifteen patients underwent surgery directed at the [18F]FET-positive focus. Tissue analysis confirmed a pituitary adenoma/pituitary neuroendocrine tumor of the corticotroph cell type (TPIT lineage) in 10 of 15 and a pituicytoma in 1 of 15, rendering a sensitivity of 100% and a positive predictive value of 73%. Lateralization was more accurate with [18F]FET PET/MRI than with IPSS in 33%. Twelve of 16 (75%) patients who received surgical, Gamma Knife, or CyberKnife therapy after [18F]FET PET/MRI reached short-term remission. Conclusion: [18F]FET PET/MRI shows a high diagnostic yield for localizing small functional pituitary tumors. This multimodal imaging technique provides a welcome improvement for diagnosis, planning of surgery, and clinical outcome in patients with Cushing disease, particularly those with repeated negative or inconclusive MRI results with or without IPSS.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias Hipofisárias , Tomografia por Emissão de Pósitrons , Tirosina/análogos & derivados , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Neoplasias Hipofisárias/diagnóstico por imagem , Neoplasias Hipofisárias/cirurgia , Adulto , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons/métodos , Imagem Multimodal , Idoso , Adulto Jovem
2.
EBioMedicine ; 102: 105068, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38518652

RESUMO

BACKGROUND: The aim of this study was to provide quantitative evidence for the potential of PSMA-targeting radioligand therapy (RLT) as treatment approach for malignant brain tumours, and to explore whether tumour uptake could be enhanced by super-selective intra-arterial (ssIA)-administration. METHODS: Ten patients (n = 5 high-grade glioma, n = 5 brain metastasis) received 1.5 MBq/kg [68Ga]Ga-PSMA-11 intravenously and, within 7 days, intra-arterially (i.e., selectively in tumour-feeding arteries), followed twice by PET-MRI at 90, 165 and 240 min post-injection. Patient safety was monitored for each procedure. Standardised uptake values (SUVs) were obtained for tumour, healthy-brain, salivary glands and liver. Tumour-to-salivary-gland (T/SG) and tumour-to-liver (T/L) uptake-ratios were calculated. FINDINGS: No adverse events requiring study termination occurred. All patients showed uptake of [68Ga]Ga-PSMA-11 at the tumour site. Uptake was a median 15-fold higher following ssIA-administration (SUVmax median: 142.8, IQR: 102.8-245.9) compared to IV-administration (10.5, IQR:7.5-13.0). According to the bootstrap analysis, mean SUVmax after ssIA (168.8, 95% CI: 110.6-227.0) was well beyond the 95% confidence-interval of IV administration (10.5, 95% CI: 8.4-12.7). Uptake in healthy-brain was negligible, independent of administration route (SUVmean <0.1-0.1). Off-target uptake was comparable, resulting in more favourable T/SG- and T/L-ratios of 8.4 (IQR: 4.4-11.5) and 26.5 (IQR: 14.0-46.4) following ssIA, versus 0.5 (IQR: 0.4-0.7) and 1.8 (IQR: 1.0-2.7) for IV-administration. INTERPRETATION: ssIA-administration is safe and leads to a median fifteen-fold higher radioligand uptake at the tumour site, therewith qualifying more patients for treatment and enhancing the potential of therapy. These results open new avenues for the development of effective RLT-based treatment strategies for patients with brain tumours. FUNDING: Semmy Foundation.


Assuntos
Neoplasias Encefálicas , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Encéfalo , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Estudos Prospectivos
3.
Front Radiol ; 4: 1338418, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38426079

RESUMO

Background and purpose: Arterial calcifications on unenhanced CT scans and vessel wall lesions on MRI are often used interchangeably to portray intracranial arterial disease. However, the extent of pathology depicted with each technique is unclear. We investigated the presence and distribution of these two imaging findings in patients with a history of cerebrovascular disease. Materials and methods: We analyzed CT and MRI data from 78 patients admitted for stroke or TIA at our institution. Vessel wall lesions were assessed on 7 T MRI sequences, while arterial calcifications were assessed on CT scans. The number of vessel wall lesions, severity of intracranial internal carotid artery (iICA) calcifications, and overall presence and distribution of the two imaging findings were visually assessed in the intracranial arteries. Results: At least one vessel wall lesion or arterial calcification was assessed in 69 (88%) patients. Only the iICA and vertebral arteries (VA) showed a substantial number of both calcifications and vessel wall lesions. The other vessels showed almost exclusively vessel wall lesions. The number of vessel wall lesions was associated with the severity of iICA calcification (p = 0.013). Conclusions: The number of vessel wall lesions increases with the severity of iICA calcifications. Nonetheless, the distribution of vessel wall lesions on MRI and arterial calcifications on CT shows remarkable differences. These findings support the need for a combined approach to examine intracranial arterial disease.

4.
Nucl Med Commun ; 45(2): 128-138, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982560

RESUMO

PURPOSE: The purpose of this study was to investigate whether 18F-fluorodeoxyglucose ( 18 F-FDG) PET/MRI may potentially improve tumor detection after neoadjuvant chemoradiotherapy (nCRT) for esophageal cancer. METHODS: This was a prospective, single-center feasibility study. At 6-12 weeks after nCRT, patients underwent standard 18 F-FDG PET/computed tomography (CT) followed by PET/MRI, and completed a questionnaire to evaluate burden. Two teams of readers either assessed the 18 F-FDG PET/CT or the 18 F-FDG PET/MRI first; the other scan was assessed 1 month later. Maximum standardized uptake value corrected for lean body mass (SUL max ) and mean apparent diffusion coefficient (ADC mean ) were measured at the primary tumor location. Histopathology of the surgical resection specimen served as the reference standard for diagnostic accuracy calculations. When patients had a clinically complete response and continued active surveillance, response evaluations until 9 months after nCRT served as a proxy for ypT and ypN (i.e. 'ycT' and 'ycN'). RESULTS: In the 21 included patients [median age 70 (IQR 62-75), 16 males], disease recurrence was found in the primary tumor in 14 (67%) patients (of whom one ypM+, detected on both scans) and in locoregional lymph nodes in six patients (29%). Accuracy (team 1/team 2) to detect yp/ycT+ with 18 F-FDG PET/MRI vs. 18 F-FDG PET/CT was 38/57% vs. 76/61%. For ypN+, accuracy was 63/53% vs. 63/42%, resp. Neither SUL max (both scans) nor ADC mean were discriminatory for yp/ycT+ . Fourteen of 21 (67%) patients were willing to undergo a similar 18 F-FDG PET/MRI examination in the future. CONCLUSION: 18 F-FDG PET/MRI currently performs comparably to 18 F-FDG PET/CT. Improvements in the scanning protocol, increasing reader experience and performing serial scans might contribute to enhancing the accuracy of tumor detection after nCRT using 18 F-FDG PET/MRI. TRIAL REGISTRATION: Netherlands Trial Register NL9352.


Assuntos
Neoplasias Esofágicas , Fluordesoxiglucose F18 , Masculino , Humanos , Idoso , Terapia Neoadjuvante/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Prospectivos , Quimiorradioterapia , Recidiva Local de Neoplasia , Compostos Radiofarmacêuticos , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/terapia , Neoplasias Esofágicas/patologia , Imageamento por Ressonância Magnética
5.
J Nucl Med ; 64(10): 1526-1531, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37652540

RESUMO

Upregulation of prostate-specific membrane antigen (PSMA) in neovasculature has been described in glioblastoma multiforme (GBM), whereas vasculature in nonaffected brain shows hardly any expression of PSMA. It is unclear whether PSMA-targeting tracer uptake on PET is based on PSMA-specific binding to neovasculature or aspecific uptake in tumor. Here, we quantified uptake of various PSMA-targeting tracers in GBM and correlated this with PSMA expression in tumor biopsy samples from the same patients. Methods: Fourteen patients diagnosed with de novo (n = 8) or recurrent (n = 6) GBM underwent a preoperative PET scan after injection of 1.5 MBq/kg [68Ga]Ga-PSMA-11 (n = 7), 200 MBq of [18F]DCFpyl (n = 3), or 200 MBq of [18F]PSMA-1007 (n = 4). Uptake in tumor and tumor-to-background ratios, with contralateral nonaffected brain as background, were determined. In a subset of patients, PSMA expression levels from different regions in the tumor tissue samples (n = 40), determined using immunohistochemistry (n = 35) or RNA sequencing (n = 13), were correlated with tracer uptake on PET. Results: Moderate to high (SUVmax, 1.3-20.0) heterogeneous uptake was found in all tumors irrespective of the tracer type used. Uptake in nonaffected brain was low, resulting in high tumor-to-background ratios (6.1-359.0) calculated by dividing SUVmax of tumor by SUVmax of background. Immunohistochemistry showed variable PSMA expression on endothelial cells of tumor microvasculature, as well as on dispersed individual cells (of unknown origin), and granular staining of the neuropil. No correlation was found between in vivo uptake and PSMA expression levels (for immunohistochemistry, r = -0.173, P = 0.320; for RNA, r = -0.033, P = 0.915). Conclusion: Our results indicate the potential use of various PSMA-targeting tracers in GBM. However, we found no correlation between PSMA expression levels on immunohistochemistry and uptake intensity on PET. Whether this may be explained by methodologic reasons, such as the inability to measure functionally active PSMA with immunohistochemistry, tracer pharmacokinetics, or the contribution of a disturbed blood-brain barrier to tracer retention, should still be investigated.


Assuntos
Glioblastoma , Neoplasias da Próstata , Masculino , Humanos , Glioblastoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Radioisótopos de Gálio , Células Endoteliais/metabolismo , Próstata/patologia , Neoplasias da Próstata/patologia , Tomografia por Emissão de Pósitrons
6.
Magn Reson Med ; 86(1): 131-142, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33538350

RESUMO

PURPOSE: Velocity-selective arterial spin labeling (VSASL) has been proposed for renal perfusion imaging to mitigate planning challenges and effects of arterial transit time (ATT) uncertainties. In VSASL, label generation may shift in the vascular tree as a function of cutoff velocity. Here, we investigate label dynamics and especially the ATT of renal VSASL and compared it with a spatially selective pulsed arterial spin labeling technique, flow alternating inversion recovery (FAIR). METHODS: Arterial spin labeling data were acquired in 7 subjects, using free-breathing dual VSASL and FAIR with five postlabeling delays: 400, 800, 1200, 2000, and 2600 ms. The VSASL measurements were acquired with cutoff velocities of 5, 10, and 15 cm/s, with anterior-posterior velocity-encoding direction. Cortical perfusion-weighted signal, temporal SNR, quantified renal blood flow, and arterial transit time were reported. RESULTS: In contrast to FAIR, renal VSASL already showed fairly high signal at the earliest postlabeling delays, for all cutoff velocities. The highest VSASL signal and temporal SNR was obtained with a cutoff velocity of 10 cm/s at postlabeling delay = 800 ms, which was earlier than for FAIR at 1200 ms. Fitted ATT on VSASL was ≤ 0 ms, indicating ATT insensitivity, which was shorter than for FAIR (189 ± 79 ms, P < .05). Finally, the average cortical renal blood flow measured with cutoff velocities of 5 cm/s (398 ± 84 mL/min/100 g) and 10 cm/s (472 ± 160 mL/min/100 g) were similar to renal blood flow measured with FAIR (441 ± 84 mL/min/100 g) (P > .05) with good correlations on subject level. CONCLUSION: Velocity-selective arterial spin labeling in the kidney reduces ATT sensitivity compared with the recommended pulsed arterial spin labeling method, as well as if cutoff velocity is increased to reduce spurious labeling due to motion. Thus, VSASL has potential as a method for time-efficient, single-time-point, free-breathing renal perfusion measurements, despite lower tSNR than FAIR.


Assuntos
Algoritmos , Artérias , Circulação Cerebrovascular , Humanos , Rim/diagnóstico por imagem , Reprodutibilidade dos Testes , Marcadores de Spin
7.
MAGMA ; 34(3): 377-387, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32954447

RESUMO

OBJECTIVES: Renal multiparametric MRI (mpMRI) is a promising tool to monitor renal allograft health to enable timely treatment of chronic allograft nephropathy. This study aims to validate mpMRI by whole-kidney histology following transplantectomy. MATERIALS AND METHODS: A patient with kidney transplant failure underwent mpMRI prior to transplantectomy. The mpMRI included blood oxygenation level-dependent (BOLD) MRI, T1 and T2 mapping, diffusion-weighted imaging (DWI), 2D phase contrast (2DPC) and arterial spin labeling (ASL). Parenchymal mpMRI measures were compared to normative values obtained in 19 healthy controls. Differences were expressed in standard deviations (SD) of normative values. The mpMRI measures were compared qualitatively to histology. RESULTS: The mpMRI showed a heterogeneous parenchyma consistent with extensive interstitial hemorrhage on histology. A global increase in T1 (+ 3.0 SD) and restricted diffusivity (- 3.6 SD) were consistent with inflammation and fibrosis. Decreased T2 (- 1.8 SD) indicated fibrosis or hemorrhage. ASL showed diminished cortical perfusion (- 2.9 SD) with patent proximal arteries. 2DPC revealed a 69% decrease in renal perfusion. Histological evaluation showed a dense inflammatory infiltrate and fibrotic changes, consistent with mpMRI results. Most interlobular arteries were obliterated while proximal arteries were patent, consistent with ASL findings. DISCUSSION: mpMRI findings correlated well with histology both globally as well as locally.


Assuntos
Transplante de Rim , Imageamento por Ressonância Magnética Multiparamétrica , Humanos , Rim , Masculino , Nefrectomia , Neoplasias da Próstata
8.
J Magn Reson Imaging ; 53(3): 859-873, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32297700

RESUMO

BACKGROUND: Renal multiparametric magnetic resonance imaging (MRI) is a promising tool for diagnosis, prognosis, and treatment monitoring in kidney disease. PURPOSE: To determine intrasubject test-retest repeatability of renal MRI measurements. STUDY TYPE: Prospective. POPULATION: Nineteen healthy subjects aged over 40 years. FIELD STRENGTH/SEQUENCES: T1 and T2 mapping, R2 * mapping or blood oxygenation level-dependent (BOLD) MRI, diffusion tensor imaging (DTI), and intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI), 2D phase contrast, arterial spin labelling (ASL), dynamic contrast enhanced (DCE) MRI, and quantitative Dixon for fat quantification at 3T. ASSESSMENT: Subjects were scanned twice with ~1 week between visits. Total scan time was ~1 hour. Postprocessing included motion correction, semiautomated segmentation of cortex and medulla, and fitting of the appropriate signal model. STATISTICAL TEST: To assess the repeatability, a Bland-Altman analysis was performed and coefficients of variation (CoVs), repeatability coefficients, and intraclass correlation coefficients were calculated. RESULTS: CoVs for relaxometry (T1 , T2 , R2 */BOLD) were below 6.1%, with the lowest CoVs for T2 maps and highest for R2 */BOLD. CoVs for all diffusion analyses were below 7.2%, except for perfusion fraction (FP ), with CoVs ranging from 18-24%. The CoV for renal sinus fat volume and percentage were both around 9%. Perfusion measurements were most repeatable with ASL (cortical perfusion only) and 2D phase contrast with CoVs of 10% and 13%, respectively. DCE perfusion had a CoV of 16%, while single kidney glomerular filtration rate (GFR) had a CoV of 13%. Repeatability coefficients (RCs) ranged from 7.7-87% (lowest/highest values for medullary mean diffusivity and cortical FP , respectively) and intraclass correlation coefficients (ICCs) ranged from -0.01 to 0.98 (lowest/highest values for cortical FP and renal sinus fat volume, respectively). DATA CONCLUSION: CoVs of most MRI measures of renal function and structure (with the exception of FP and perfusion as measured by DCE) were below 13%, which is comparable to standard clinical tests in nephrology. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.


Assuntos
Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Adulto , Difusão , Feminino , Taxa de Filtração Glomerular , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Movimento (Física) , Perfusão , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Marcadores de Spin
9.
Magn Reson Med ; 85(5): 2580-2594, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33251644

RESUMO

PURPOSE: Flow-based arterial spin labeling (ASL) techniques provide a transit-time insensitive alternative to the more conventional spatially selective ASL techniques. However, it is not clear which flow-based ASL technique performs best and also, how these techniques perform outside the brain (taking into account eg, flow-dynamics, field-inhomogeneity, and organ motion). In the current study we aimed to compare 4 flow-based ASL techniques (ie, velocity selective ASL, acceleration selective ASL, multiple velocity selective saturation ASL, and velocity selective inversion prepared ASL [VSI-ASL]) to the current spatially selective reference techniques in brain (ie, pseudo-continuous ASL [pCASL]) and kidney (ie, pCASL and flow alternating inversion recovery [FAIR]). METHODS: Brain (n = 5) and kidney (n = 6) scans were performed in healthy subjects at 3T. Perfusion-weighted signal (PWS) maps were generated and ASL techniques were compared based on temporal SNR (tSNR), sensitivity to perfusion changes using a visual stimulus (brain) and robustness to respiratory motion by comparing scans acquired in paced-breathing and free-breathing (kidney). RESULTS: In brain, all flow-based ASL techniques showed similar tSNR as pCASL, but only VSI-ASL showed similar sensitivity to perfusion changes. In kidney, all flow-based ASL techniques had comparable tSNR, although all lower than FAIR. In addition, VSI-ASL showed a sensitivity to B1 -inhomogeneity. All ASL techniques were relatively robust to respiratory motion. CONCLUSION: In both brain and kidney, flow-based ASL techniques provide a planning-free and transit-time insensitive alternative to spatially selective ASL techniques. VSI-ASL shows the most potential overall, showing similar performance as the golden standard pCASL in brain. However, in kidney, a reduction of B1 -sensitivity of VSI-ASL is necessary to match the performance of FAIR.


Assuntos
Algoritmos , Imagem de Perfusão , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular , Humanos , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Razão Sinal-Ruído , Marcadores de Spin
10.
Magn Reson Med ; 84(4): 1828-1843, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32141655

RESUMO

PURPOSE: Placental function is key for successful human pregnancies. Perfusion may be a sensitive marker for the in vivo assessment of placental function. Arterial spin labeling (ASL) MRI enables noninvasive measurement of tissue perfusion and it was recently suggested that ASL with velocity-selective (VS) labeling could be advantageous in the placenta. We systematically evaluated essential VS-ASL sequence parameters to determine optimal settings for efficient placental perfusion measurements. METHODS: Eleven pregnant women were scanned at 3T using VS-ASL with 2D multislice echo planar imaging (EPI)-readout. One reference VS-ASL scan was acquired in all subjects; within subgroups the following parameters were systematically varied: cutoff velocity, velocity encoding direction, and inflow time. Visual evaluation and region of interest analyses were performed to compare perfusion signal differences between acquisitions. RESULTS: In all subjects, a perfusion pattern with clear hyperintense focal regions was observed. Perfusion signal decreased with inflow time and cutoff velocity. Subject-specific dependence on velocity encoding direction was observed. High temporal signal-to-noise ratios with high contrast on the perfusion images between the hyperintense regions and placental tissue were seen at ~1.6 cm/s cutoff velocity and ~1000 ms inflow time. Evaluation of measurements at multiple inflow times revealed differences in blood flow dynamics between placental regions. CONCLUSION: Placental perfusion measurements are feasible at 3T using VS-ASL with 2D multislice EPI-readout. A clear dependence of perfusion signal on VS labeling parameters and inflow time was demonstrated. Whereas multiple parameter combinations may advance the interpretation of placental circulation dynamics, this study provides a basis to select an effective set of parameters for the observation of placenta perfusion natural history and its potential pathological changes.


Assuntos
Artérias , Imageamento por Ressonância Magnética , Circulação Cerebrovascular , Feminino , Humanos , Angiografia por Ressonância Magnética , Perfusão , Placenta/diagnóstico por imagem , Gravidez , Marcadores de Spin
11.
Magn Reson Med ; 84(4): 1919-1932, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32180263

RESUMO

PURPOSE: Arterial transit time uncertainties and challenges during planning are potential issues for renal perfusion measurement using spatially selective arterial spin labeling techniques. To mitigate these potential issues, a spatially non-selective technique, such as velocity-selective arterial spin labeling (VSASL), could be an alternative. This article explores the influence of VSASL sequence parameters and respiratory induced motion on VS-label generation. METHODS: VSASL data were acquired in human subjects (n = 15), with both single and dual labeling, during paced-breathing, while essential sequence parameters were systematically varied; (1) cutoff velocity, (2) labeling gradient orientation and (3) post-labeling delay (PLD). Pseudo-continuous ASL was acquired as a spatially selective reference. In an additional free-breathing single VSASL experiment (n = 9) we investigated respiratory motion influence on VS-labeling. Absolute renal blood flow (RBF), perfusion weighted signal (PWS), and temporal signal-to-noise ratio (tSNR) were determined. RESULTS: (1) With decreasing cutoff velocity, tSNR and PWS increased. However, undesired tissue labeling occurred at low cutoff velocities (≤ 5.4 cm/s). (2) Labeling gradient orientation had little effect on tSNR and PWS. (3) For single VSASL high signal appeared in the kidney pedicle at PLD < 800 ms, and tSNR and PWS decreased with increasing PLD. For dual VSASL, maximum tSNR occurred at PLD = 1200 ms. Average cortical RBF measured with dual VSASL (264 ± 34 mL/min/100 g) at a cutoff velocity of 5.4 cm/s, and feet-head labeling was slightly lower than with pseudo-continuous ASL (283 ± 55 mL/min/100 g). CONCLUSION: With well-chosen sequence parameters, tissue labeling induced by respiratory motion can be minimized, allowing to obtain good quality RBF maps using planning-free labeling with dual VSASL.


Assuntos
Algoritmos , Imagem de Perfusão , Velocidade do Fluxo Sanguíneo , Circulação Cerebrovascular , Humanos , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Movimento (Física) , Reprodutibilidade dos Testes , Marcadores de Spin
12.
Radiology ; 295(1): 162-170, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32013790

RESUMO

Background Intracranial atherosclerosis is an important cause of ischemic stroke and is associated with several vascular risk factors. Current imaging is mainly based on the assessment of luminal narrowing rather than abnormalities in the vessel wall. Purpose To investigate the relationship between vascular risk factors and atherosclerotic lesion burden of intracranial arteries assessed with vessel wall MRI at 7 T in participants with ischemic stroke or transient ischemic attack (TIA). Materials and Methods In this prospective study (trial identification number: NTR2119; www.trialregister.nl), study participants who presented with ischemic stroke or TIA of the anterior circulation between December 2009 and September 2017 underwent pre- and postcontrast 7-T vessel wall MRI within 3 months of symptom onset. All large arteries of the intracranial circulation were assessed for number, location, and enhancement of vessel wall lesions. Generalized estimating equations for Poisson regression were used to investigate the relationship between vascular risk factors and number or enhancement of vessel wall lesions. Results Ninety participants (52 men; mean age, 60 years) were evaluated. Increasing age (relative risk [RR], 1.02; 95% confidence interval [CI]: 1.01, 1.03), hypertension (RR, 1.46; 95% CI: 1.06, 2.02), diabetes mellitus (RR, 1.67; 95% CI: 1.20, 2.33), and a higher multivariable vascular risk score (Second Manifestations of Arterial Disease risk score) (RR, 1.01; 95% CI: 1.00, 1.02) were associated with a higher number of vessel wall lesions in the anterior circulation. Contrast material-enhancing vessel wall lesions were associated only with increasing age (RR, 1.03; 95% CI: 1.01, 1.05). No association was found between smoking and the number of vessel wall lesions. Conclusion Except for smoking, traditional common cardiovascular risk factors were associated with a higher number and enhancement of intracranial vessel wall lesions at 7-T MRI in individuals evaluated after ischemic stroke or transient ischemic attack. Published under a CC BY 4.0 license. Online supplemental material is available for this article.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Arteriosclerose Intracraniana/diagnóstico por imagem , Ataque Isquêmico Transitório/diagnóstico por imagem , Imageamento por Ressonância Magnética , Acidente Vascular Cerebral/diagnóstico por imagem , Isquemia Encefálica/complicações , Isquemia Encefálica/etiologia , Feminino , Humanos , Arteriosclerose Intracraniana/complicações , Ataque Isquêmico Transitório/etiologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia
13.
Magn Reson Med ; 83(2): 549-560, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31433077

RESUMO

PURPOSE: To study placental function-both perfusion and an oxygenation surrogate ( T2* )-simultaneously and quantitatively in-vivo. METHODS: Fifteen pregnant women were scanned on a 3T MR scanner. For perfusion measurements, a velocity selective arterial spin labeling preparation module was placed before a multi-echo gradient echo EPI readout to integrate T2* and perfusion measurements in 1 joint perfusion-oxygenation (PERFOX) acquisition. Joint motion correction and quantification were performed to evaluate changes in T2* and perfusion over GA. RESULTS: The optimized integrated PERFOX protocol and post-processing allowed successful visualization and quantification of perfusion and T2* in all subjects. Areas of high T2* and high perfusion appear to correspond to placental sub-units and show a systematic offset in location along the maternal-fetal axis. The areas of highest perfusion are consistently closer to the maternal basal plate and the areas of highest T2* closer to the fetal chorionic plate. Quantitative results show a strong negative correlation of gestational age with T2* and weak negative correlation with perfusion. CONCLUSIONS: A strength of the joint sequence is that it provides truly simultaneous and co-registered estimates of local T2* and perfusion, however, to achieve this, the time per slice is prolonged compared to a perfusion only scan which can potentially limit coverage. The achieved interlocking can be particularly useful when quantifying transient physiological effects such as uterine contractions. PERFOX opens a new avenue to elucidate the relationship between maternal supply and oxygen uptake, both of which are central to placental function and dysfunction.


Assuntos
Imagem Ecoplanar , Imageamento por Ressonância Magnética , Oxigênio/metabolismo , Placenta/fisiologia , Algoritmos , Circulação Sanguínea , Meios de Contraste , Feminino , Análise de Fourier , Idade Gestacional , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Angiografia por Ressonância Magnética , Movimento (Física) , Perfusão , Gravidez , Marcadores de Spin
14.
MAGMA ; 33(1): 81-94, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31811490

RESUMO

OBJECTIVE: To compare the most commonly used labeling approaches, flow-sensitive alternating inversion recovery (FAIR) and pseudocontinuous arterial spin labeling (pCASL), for renal perfusion measurement using arterial spin labeling (ASL) MRI. METHODS: Multi-delay FAIR and pCASL were performed in 16 middle-aged healthy volunteers on two different occasions at 3T. Relative perfusion-weighted signal (PWS), temporal SNR (tSNR), renal blood flow (RBF), and arterial transit time (ATT) were calculated for the cortex and medulla in both kidneys. Bland-Altman plots, intra-class correlation coefficient, and within-subject coefficient of variation were used to assess reliability and agreement between measurements. RESULTS: For the first visit, RBF was 362 ± 57 and 140 ± 47 mL/min/100 g, and ATT was 0.47 ± 0.13 and 0.70 ± 0.10 s in cortex and medulla, respectively, using FAIR; RBF was 201 ± 72 and 84 ± 27 mL/min/100 g, and ATT was 0.71 ± 0.25 and 0.86 ± 0.12 s in cortex and medulla, respectively, using pCASL. For both labeling approaches, RBF and ATT values were not significantly different between visits. Overall, FAIR showed higher PWS and tSNR. Moreover, repeatability of perfusion parameters was better using FAIR. DISCUSSION: This study showed that compared to (balanced) pCASL, FAIR perfusion values were significantly higher and more comparable between visits.


Assuntos
Artérias/diagnóstico por imagem , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Marcadores de Spin , Adulto , Feminino , Taxa de Filtração Glomerular , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Córtex Renal/diagnóstico por imagem , Medula Renal/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Perfusão , Estudos Prospectivos , Circulação Renal , Reprodutibilidade dos Testes , Razão Sinal-Ruído
15.
J Magn Reson Imaging ; 52(2): 622-631, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31799793

RESUMO

BACKGROUND: Gadolinium-based contrast agents (GBCAs) are widely used in MRI, despite safety concerns regarding deposition in brain and other organs. In animal studies gadolinium was detected for weeks after administration in the kidneys, but this has not yet been demonstrated in humans. PURPOSE: To find evidence for the prolonged presence of gadobutrol in the kidneys in healthy volunteers. STUDY TYPE: Combined retrospective and prospective analysis of a repeatability study. POPULATION: Twenty-three healthy volunteers with normal renal function (12 women, age range 40-76 years), of whom 21 were used for analysis. FIELD STRENGTH/SEQUENCE: Inversion recovery-based T1 map at 3T. ASSESSMENT: T1 maps were obtained twice with a median interval of 7 (range: 4-16) days. The T1 difference (ΔT1 ) between both scans was compared between the gadolinium group (n = 16, 0.05 mmol/kg gadobutrol administered after T1 mapping during both scan sessions) and the control group (n = 5, no gadobutrol). T1 maps were analyzed separately for cortex and medulla. STATISTICAL TESTS: Mann-Whitney U-tests to detect differences in ΔT1 between groups and linear regression to relate time between scans and estimated glomerular filtration rate (eGFR) to ΔT1 . RESULTS: ΔT1 differed significantly between the gadolinium and control group: median ΔT1 cortex -98 vs. 7 msec (P < 0.001) and medulla -68 msec vs. 19 msec (P = 0.001), respectively. The bias corresponds to renal gadobutrol concentrations of 8 nmol/g tissue (cortex) and 4 nmol/g tissue (medulla), ie, ~2.4 µmol for both kidneys (0.05% of original dose). ΔT1 correlated in the gadolinium group with duration between acquisitions for both cortex (regression coefficient (ß) 16.5 msec/day, R2 0.50, P < 0.001) and medulla (ß 11.5 msec/day, R2 0.32, P < 0.001). Medullary ΔT1 correlated with eGFR (ß 1.13 msec/(ml/min) R2 0.25, P = 0.008). DATA CONCLUSION: We found evidence of delayed renal gadobutrol excretion after a single contrast agent administration in subjects with normal renal function. Even within this healthy population, elimination delay increased with decreasing kidney function. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2020;52:622-631.


Assuntos
Compostos Organometálicos , Adulto , Idoso , Animais , Meios de Contraste , Feminino , Voluntários Saudáveis , Humanos , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos
16.
MAGMA ; 33(1): 141-161, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31833014

RESUMO

OBJECTIVES: This study aimed at developing technical recommendations for the acquisition, processing and analysis of renal ASL data in the human kidney at 1.5 T and 3 T field strengths that can promote standardization of renal perfusion measurements and facilitate the comparability of results across scanners and in multi-centre clinical studies. METHODS: An international panel of 23 renal ASL experts followed a modified Delphi process, including on-line surveys and two in-person meetings, to formulate a series of consensus statements regarding patient preparation, hardware, acquisition protocol, analysis steps and data reporting. RESULTS: Fifty-nine statements achieved consensus, while agreement could not be reached on two statements related to patient preparation. As a default protocol, the panel recommends pseudo-continuous (PCASL) or flow-sensitive alternating inversion recovery (FAIR) labelling with a single-slice spin-echo EPI readout with background suppression and a simple but robust quantification model. DISCUSSION: This approach is considered robust and reproducible and can provide renal perfusion images of adequate quality and SNR for most applications. If extended kidney coverage is desirable, a 2D multislice readout is recommended. These recommendations are based on current available evidence and expert opinion. Nonetheless they are expected to be updated as more data become available, since the renal ASL literature is rapidly expanding.


Assuntos
Circulação Cerebrovascular , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Marcadores de Spin , Pesquisa Translacional Biomédica/tendências , Algoritmos , Consenso , Técnica Delphi , Imagem Ecoplanar , Humanos , Processamento de Imagem Assistida por Computador/métodos , Rim/irrigação sanguínea , Transplante de Rim , Angiografia por Ressonância Magnética , Estudos Multicêntricos como Assunto , Perfusão , Artéria Renal/diagnóstico por imagem , Reprodutibilidade dos Testes , Razão Sinal-Ruído
18.
Magn Reson Med ; 82(1): 276-288, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30883873

RESUMO

PURPOSE: For free-breathing renal perfusion imaging using arterial spin labeling (ASL), retrospective image realignment has been found essential to reduce subtraction artifacts and, independently, background suppression has been demonstrated to reduce physiologic noise. However, negative results on ASL precision and accuracy have been reported for the combination of both. In this study, the effect of background suppression -level in combination with image registration on free-breathing renal ASL signal quality, with registration either on ASL-images themselves or guided by additionally acquired fat-images, was investigated. The results from free-breathing acquisitions were compared with the reference paced-breathing motion compensation strategy. METHODS: Pseudocontinuous ASL (pCASL) data with additional fat-images were acquired from 10 subjects at 1.5T with varying background suppression levels during free-breathing and paced-breathing. Images were registered using the ASL-images themselves (ASLReg) or using their corresponding fat-images (FatReg). Temporal signal-to-noise ratio (tSNR) served to evaluate precision and perfusion weighted signal (PWS) to assess accuracy. RESULTS: In combination with image registration, background suppression significantly improved tSNR by 50% (P < .05). For heavy suppression, ASLReg and FatReg showed similar performance in terms of tSNR and PWS. Background suppression with two inversion pulses induced a small, nonsignificant (P > .05) PWS reduction, but increased PWS accuracy. When applying heavy background suppression, free-breathing acquisitions resulted in similar ASL-quality to paced-breathing acquisitions. CONCLUSION: Background suppression was found beneficial for free-breathing renal pCASL precision without compromising accuracy, despite motion challenges. In combination with ASLReg or FatReg, background suppression enabled clinically viable free-breathing renal pCASL.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Artefatos , Feminino , Humanos , Rim/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Movimento/fisiologia , Imagem de Perfusão/métodos , Respiração , Adulto Jovem
19.
Anat Rec (Hoboken) ; 302(8): 1434-1446, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30332725

RESUMO

Quantitative data on branching patterns of the human cerebral arterial tree are lacking in the 1.0-0.1 mm radius range. We aimed to collect quantitative data in this range, and to study if the cerebral artery tree complies with the principle of minimal work (Law of Murray). To enable easy quantification of branching patterns a semi-automatic method was employed to measure 1,294 bifurcations and 2,031 segments on 7 T-MRI scans of two corrosion casts embedded in a gel. Additionally, to measure segments with a radius smaller than 0.1 mm, 9.4 T-MRI was used on a small cast section to characterize 1,147 bifurcations and 1,150 segments. Besides MRI, traditional methods were employed. Seven hundred thirty-three bifurcations were manually measured on a corrosion cast and 1,808 bifurcations and 1,799 segment lengths were manually measured on a fresh dissected cerebral arterial tree. Data showed a large variation in branching pattern parameters (asymmetry-ratio, area-ratio, length-radius-ratio, tapering). Part of the variation may be explained by the variation in measurement techniques, number of measurements and location of measurement in the vascular tree. This study confirms that the cerebral arterial tree complies with the principle of minimum work. These data are essential in the future development of more accurate mathematical blood flow models. Anat Rec, 302:1434-1446, 2019. © 2018 The Authors. The Anatomical Record published by Wiley Periodicals, Inc. on behalf of American Association of Anatomists.


Assuntos
Encéfalo/anatomia & histologia , Artérias Cerebrais/anatomia & histologia , Modelos Teóricos , Idoso , Encéfalo/fisiologia , Artérias Cerebrais/fisiologia , Circulação Cerebrovascular , Feminino , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
20.
Sci Rep ; 8(1): 14235, 2018 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-30250281

RESUMO

Quantitative data on the morphology of the cerebral arterial tree could aid in modelling and understanding cerebrovascular diseases, but is scarce in the range between 200 micrometres and 1 mm diameter arteries. Traditional manual measurements are difficult and time consuming. 7T-MRI and 9.4T-MRI of human cerebral arterial plastic casts could proof feasible for acquiring detailed morphological data of the cerebral arterial tree in a time efficient method. One cast of the complete human cerebral arterial circulation embedded in gadolinium-containing gelatine gel was scanned at 7T-MRI (0.1 mm isotropic resolution). A small section of another cast was scanned at 9.4T-MRI (30 µm isotropic resolution). Subsequent 3D-reconstruction was performed using a semi-automatic approach. Validation of 7T-MRI was performed by comparing the radius calculated using MRI to manual measurements on the same cast. As manual measurement of the small section was not feasible, 9.4T-MRI was validated by scanning the small section both at 7T-MRI and 9.4T MRI and comparing the diameters of arterial segments. Linear regression slopes were 0.97 (R-squared 0.94) and 1.0 (R-squared 0.90) for 7T-MRI and 9.4T-MRI. This data shows that 7T-MRI and 9.4T-MRI and subsequent 3D reconstruction of plastic casts is feasible, and allows for characterization of human cerebral arterial tree morphology.


Assuntos
Encéfalo/diagnóstico por imagem , Artérias Cerebrais/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Imageamento por Ressonância Magnética , Pesos e Medidas Corporais , Encéfalo/fisiologia , Artérias Cerebrais/fisiologia , Gadolínio/administração & dosagem , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA