RESUMO
BACKGROUND: Stent implantation has become the preferred method of treatment for treating vessel stenosis in congenital heart diseases. The availability of covered stents may decrease complications and have an important role in the management of patients with complex anatomy. AIM: This study aims to evaluate the feasibility and safety of the pre-mounted cobalt-chromium stent-graft-covered ePTFE Aortic BeGraft in a broad spectrum of vascular lesions. METHODS: This is a multicenter retrospective results analysis of 107 implanted BeGraft stents between 2016 and 2022 in six different European centers. RESULTS: One hundred and four patients with a mean age of thirteen years (range 1-70 years) and with the body weight of 56.5 kg (range 11-115 kg) underwent the BeGraft stent implantation. Stents were implanted in the following conditions: aortic coarctation (74 patients), RVOT dysfunction (12 patients), Fontan circulation (7 patients), and miscellaneous (11 subjects with complex CHD). All the stents were implanted successfully. The median stent diameter was 16 mm (range 7-24 mm), and the median length was 39 mm (range 19-49 mm). Major complications occurred in five subjects (4.7%). During a median follow-up of fourteen (1-70) months, stents' re-dilatation was performed in five patients. CONCLUSIONS: The BeGraft stent can be used safely and effectively in a wide spectrum of congenital heart diseases. Whether these good results will be stable in the longer term still needs to be investigated in a follow-up given its recent introduction into clinical practice, in particular regarding stent fracture or neointimal proliferation.
RESUMO
Pulmonary hypertension (PH) continues to present significant challenges to the medical community, both in terms of diagnosis and treatment. The advent of the updated 2022 European Society of Cardiology (ESC) and European Respiratory Society (ERS) guidelines has introduced pivotal changes that reflect the rapidly advancing understanding of this complex disease. These changes include a revised definition of PH, updates to the classification system, and treatment algorithm. While these guidelines offer a critical framework for the management of PH, they have also sparked new discussions and questions. The 5th French Pulmonary Hypertension Network Meeting (Le Kremlin-Bicêtre, France, 2023), addressed these emergent questions and fostering a deeper understanding of the disease's multifaceted nature. These discussions were not limited to theoretical advancements but extended into the practical realms of patient management, highlighting the challenges and opportunities in applying the latest guidelines to clinical practice.
Assuntos
Implante de Prótese de Valva Cardíaca , Valva Pulmonar , Tetralogia de Fallot , Humanos , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/complicações , Tetralogia de Fallot/fisiopatologia , Masculino , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Valor Preditivo dos Testes , Adolescente , Adulto Jovem , Adulto , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/diagnóstico , Imagem Cinética por Ressonância Magnética , Criança , Resultado do TratamentoAssuntos
Comunicação Interatrial , Humanos , Comunicação Interatrial/cirurgia , Feminino , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Hipertensão Arterial Pulmonar/cirurgia , Hipertensão Pulmonar/cirurgia , Adulto , Dispositivo para Oclusão Septal , IdosoRESUMO
Scimitar syndrome is characterised by right lung hypoplasia and abnormal pulmonary venous return, known as the 'scimitar vein'. We report the case of an infant girl with scimitar syndrome who developed a severe respiratory distress mimicking asthma. Pulmonary hypertension (PH) was diagnosed, attributed to scimitar vein stenosis and a left-to-right shunt. Scimitar vein stenosis, a rare complication of scimitar syndrome, can lead to severe PH, highlighting the importance of prompt management in specialised care centres.
Assuntos
Síndrome de Cimitarra , Humanos , Síndrome de Cimitarra/diagnóstico por imagem , Síndrome de Cimitarra/complicações , Síndrome de Cimitarra/diagnóstico , Feminino , Lactente , Constrição Patológica , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/diagnóstico , Diagnóstico Diferencial , Veias Pulmonares/anormalidades , Veias Pulmonares/diagnóstico por imagem , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/diagnósticoRESUMO
Synthetic biomaterials play a crucial role in developing tissue-engineered heart valves (TEHVs) due to their versatile mechanical properties. Achieving the right balance between mechanical strength and manufacturability is essential. Thermoplastic polyurethanes (TPUs) and elastomers (TPEs) garner significant attention for TEHV applications due to their notable stability, fatigue resistance, and customizable properties such as shear strength and elasticity. This study explores the additive manufacturing technique of selective laser sintering (SLS) for TPUs and TPEs to optimize process parameters to balance flexibility and strength, mimicking aortic valve tissue properties. Additionally, it aims to assess the feasibility of printing aortic valve models with submillimeter membranes. The results demonstrate that the SLS-TPU/TPE technique can produce micrometric valve structures with soft shape memory properties, resembling aortic tissue in strength, flexibility, and fineness. These models show promise for surgical training and manipulation, display intriguing echogenicity properties, and can potentially be personalized to shape biocompatible valve substitutes.
RESUMO
[This corrects the article DOI: 10.1016/j.jhepr.2023.100933.].
RESUMO
BACKGROUND AND AIMS: Cardiopulmonary fitness in congenital heart disease (CHD) decreases faster than in the general population resulting in impaired health-related quality of life (HRQoL). As the standard of care seems insufficient to encourage and maintain fitness, an early hybrid cardiac rehabilitation programme could improve HRQoL in CHD. METHODS: The QUALIREHAB multicentre, randomized, controlled trial evaluated and implemented a 12-week centre- and home-based hybrid cardiac rehabilitation programme, including multidisciplinary care and physical activity sessions. Adolescent and young adult CHD patients with impaired cardiopulmonary fitness were randomly assigned to either the intervention (i.e. cardiac rehabilitation) or the standard of care. The primary outcome was the change in HRQoL from baseline to 12-month follow-up in an intention-to-treat analysis. The secondary outcomes were the change in cardiovascular parameters, cardiopulmonary fitness, and mental health. RESULTS: The expected number of 142 patients was enroled in the study (mean age 17.4 ± 3.4 years, 52% female). Patients assigned to the intervention had a significant positive change in HRQoL total score [mean difference 3.8; 95% confidence interval (CI) 0.2; 7.3; P = .038; effect size 0.34], body mass index [mean difference -0.7â kg/m2 (95% CI -1.3; -0.1); P = .022; effect size 0.41], level of physical activity [mean difference 2.5 (95% CI 0.1; 5); P = .044; effect size 0.39], and disease knowledge [mean difference 2.7 (95% CI 0.8; 4.6); P = .007; effect size 0.51]. The per-protocol analysis confirmed these results with a higher magnitude of differences. Acceptability, safety, and short-time effect of the intervention were good to excellent. CONCLUSIONS: This early hybrid cardiac rehabilitation programme improved HRQoL, body mass index, physical activity, and disease knowledge, in youth with CHD, opening up the possibility for the QUALIREHAB programme to be rolled out to the adult population of CHD and non-congenital cardiac disease.
Assuntos
Reabilitação Cardíaca , Cardiopatias Congênitas , Adolescente , Feminino , Humanos , Masculino , Adulto Jovem , Reabilitação Cardíaca/métodos , Exercício Físico , Terapia por Exercício , Qualidade de VidaRESUMO
PURPOSE: The purpose of this study was to evaluate the accuracy of four-dimensional flow cardiac magnetic resonance imaging (4D flow MRI) compared to right heart catheterization in measuring pulmonary flow (Qp), systemic flow (Qs) and pulmonary-to-systemic flow ratio (Qp/Qs) in patients with pulmonary arterial hypertension associated with congenital heart disease (PAH-CHD). MATERIALS AND METHODS: The study was registered on Clinical-trial.gov (NCT03928002). Sixty-four patients with PAH-CHD who underwent 4D flow MRI were included. There were 16 men and 48 women with a mean age of 45.3 ± 13.7 (standard deviation [SD]) years (age range: 21-77 years). Fifty patients (50/64; 78%) presented with pre-tricuspid shunt. Qp (L/min), Qs (L/min) and Qp/Qs were measured invasively using direct Fick method during right heart catheterization and compared with measurements assessed by 4D flow MRI within a 24-48-hour window. RESULTS: The average mean pulmonary artery pressure was 51 ± 17 (SD) mm Hg with median pulmonary vascular resistance of 8.8 Wood units (Q1, Q3: 5.3, 11.7). A strong linear correlation was found between Qp measurements obtained with 4D flow MRI and those obtained with the Fick method (r = 0.96; P < 0.001). Bland Altman analysis indicated a mean difference of 0.15 ± 0.48 (SD) L/min between Qp estimated by 4D flow MRI and by right heart catheterization. A strong correlation was found between Qs and Qp/Qs measured by 4D flow MRI and those obtained with the direct Fick method (r = 0.85 and r = 0.92; P < 0.001 for both). CONCLUSION: Qp as measured by 4D flow MRI shows a strong correlation with measurements derived from the direct Fick method. Further investigation is needed to develop less complex and standardized methods for measuring essential PAH parameters, such as pulmonary arterial pressures and pulmonary vascular resistance.
Assuntos
Cateterismo Cardíaco , Cardiopatias Congênitas , Imageamento por Ressonância Magnética , Circulação Pulmonar , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/fisiopatologia , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Hipertensão Arterial Pulmonar/diagnóstico por imagem , Hipertensão Arterial Pulmonar/fisiopatologia , Circulação Pulmonar/fisiologia , Estudos ProspectivosRESUMO
Congenital portosystemic shunts are often associated with systemic complications, the most challenging of which are liver nodules, pulmonary hypertension, endocrine abnormalities, and neurocognitive dysfunction. In the present paper, we offer expert clinical guidance on the management of liver nodules, pulmonary hypertension, and endocrine abnormalities, and we make recommendations regarding shunt closure and follow-up.
RESUMO
BACKGROUND AND AIMS: Transcatheter pulmonary valve implantation (TPVI) is indicated to treat right-ventricular outflow tract (RVOT) dysfunction related to congenital heart disease (CHD). Outcomes of TPVI with the SAPIEN 3 valve that are insufficiently documented were investigated in the EUROPULMS3 registry of SAPIEN 3-TPVI. METHODS: Patient-related, procedural, and follow-up outcome data were retrospectively assessed in this observational cohort from 35 centres in 15 countries. RESULTS: Data for 840 consecutive patients treated in 2014-2021 at a median age of 29.2 (19.0-41.6) years were obtained. The most common diagnosis was conotruncal defect (70.5%), with a native or patched RVOT in 50.7% of all patients. Valve sizes were 20, 23, 26, and 29â mm in 0.4%, 25.5%, 32.1%, and 42.0% of patients, respectively. Valve implantation was successful in 98.5% [95% confidence interval (CI), 97.4%-99.2%] of patients. Median follow-up was 20.3 (7.1-38.4) months. Eight patients experienced infective endocarditis; 11 required pulmonary valve replacement, with a lower incidence for larger valves (P = .009), and four experienced pulmonary valve thrombosis, including one who died and three who recovered with anticoagulation. Cumulative incidences (95%CI) 1, 3, and 6 years after TPVI were as follows: infective endocarditis, 0.5% (0.0%-1.0%), 0.9% (0.2%-1.6%), and 3.8% (0.0%-8.4%); pulmonary valve replacement, 0.4% (0.0%-0.8%), 1.3% (0.2%-2.4%), and 8.0% (1.2%-14.8%); and pulmonary valve thrombosis, 0.4% (0.0%-0.9%), 0.7% (0.0%-1.3%), and 0.7% (0.0%-1.3%), respectively. CONCLUSIONS: Outcomes of SAPIEN 3 TPVI were favourable in patients with CHD, half of whom had native or patched RVOTs.
Assuntos
Endocardite Bacteriana , Endocardite , Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Trombose , Adulto , Humanos , Cateterismo Cardíaco/efeitos adversos , Endocardite/epidemiologia , Endocardite Bacteriana/complicações , Cardiopatias Congênitas/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Desenho de Prótese , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/epidemiologia , Insuficiência da Valva Pulmonar/cirurgia , Sistema de Registros , Estudos Retrospectivos , Trombose/etiologia , Resultado do TratamentoRESUMO
OBJECTIVES: Heart transplantation (HT) is the only life-extending therapy in adults with congenital heart disease (CHD) and end-stage heart failure. HT is considered at high risk in complex CHD given the anatomical complexity and past medical history. Little is known about long-term outcomes after HT in these patients. We aimed to evaluate early and long-term outcomes after HT in adult patients with univentricular versus biventricular CHD. METHODS: This multicentre retrospective cohort study included all adult CHD patients who underwent HT between 1988 and 2021 in 3 tertiary centres. Factors associated with early (<30 days) and conditional long-term survival were assessed in the entire cohort. RESULTS: Over a mean follow-up of 10.1 ± 7.8 years, 149 patients were included, of whom 55 (36.9%) had univentricular CHD. Sixty-four patients died during follow-up including 47 deaths before discharge from hospital. In multivariable analysis, univentricular physiology and female recipient gender were independently associated with a higher risk of early mortality (odds ratio 2.99; 95% confidence interval [1.33-6.74] and odds ratio 2.76; 95% confidence interval [1.23-6.20], respectively). For patients who survived the early period, conditional long-term survival was excellent for both groups and was not different between 2 groups (P = 0.764). CONCLUSIONS: Adult CHD patients have a high incidence of overall mortality due to a high rate of early mortality. Univentricular physiology was associated with a significant increased risk of early death compared to biventricular physiology. However, late mortality was excellent and no longer different between the 2 physiologies.
Assuntos
Cardiopatias Congênitas , Transplante de Coração , Adulto , Humanos , Feminino , Estudos Retrospectivos , Cardiopatias Congênitas/cirurgia , Alta do Paciente , Incidência , Resultado do TratamentoAssuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Humanos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Resultado do Tratamento , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , BioengenhariaRESUMO
BACKGROUND: Reverse Potts shunt (RPS) and lung or heart-lung transplantation are life-extending surgical interventions for pediatric patients with severe pulmonary arterial hypertension (PAH). Robust criteria for identifying patients who will benefit from these procedures remain elusive. Based on 30 years of experience, we sought to refine the surgical indications. METHODS: This single-center retrospective cohort study included 61 consecutive pediatric patients with PAH managed by RPS (2004-2020) or transplantation (1988-2020). Their mid-term outcomes were assessed. RESULTS: Compared with the 20 patients managed by RPS, the 41 transplant waitlist patients, of whom 28 were transplanted, were older (14.9 vs 8.0 years, P = .0001), had worse right ventricular impairment (tricuspid annular plane systolic excursion, 12.5 mm vs 18.0 mm, P = .03), and were managed later in the evolution of the disease (6.0 vs 1.7 years, P = .002). After implementation of a high-priority allocation program in 2007, waitlist mortality decreased from 52.6% to 13.6% (P = .02) and 5-year survival increased from 57.1% to 74.7% after RPS and 55.6% to 77.2% after transplantation. At a median follow-up of 8.6 years after RPS and 5.9 years after transplantation, functional capacity had improved significantly, and PAH-specific drug requirements had diminished markedly in the RPS group. Two patients successfully underwent double-lung transplant 6 and 9 years after RPS. CONCLUSIONS: In selected children with suprasystemic PAH, RPS is associated with functional capacity improvements and decreased pharmacotherapy needs over the midterm. RPS deserves consideration earlier in the course of pediatric PAH, with transplantation being performed in the event of refractory RV failure.
RESUMO
INTRODUCTION: Percutaneous pulmonary valve implantation (PPVI) with a SAPIEN 3 valve is effective for treating treat right ventricle outflow (RVOT) dysfunction. A modified technique was developed without prestenting using a protective valve delivery method. We aimed to compare the procedural results of the modified technique group (MTG) to those of patients in a conventional technique group (CTG). METHODS: We designed a matched before-after study. All consecutive PPVI with SAPIEN 3 performed in the MTG over 9 months were matched, based on the RVOT type and size, to consecutive procedures performed previously with SAPIEN 3. RESULTS: A total of 54 patients were included, equally distributed in the two groups. The sizes of the SAPIEN 3 valves were 23 mm (n = 9), 26 mm (n = 9), 29 mm (n = 36). The two groups were similar regarding demographic data, RVOT type, and pre-procedure hemodynamics. PPVI was performed in a single procedure in all patients of the MTG, whereas six (22.2%) patients of the CTG group underwent prestenting as a first step and valve implantation later (p = 0.02). The procedures were successful in all cases. Stent embolization was reported in two patients (7.4%) in the CTG, which were impacted in pulmonary arteries. In one case (3.7%), in the MTG, an unstable 29 mm SAPIEN 3 valve was stabilized with two stents and additional valve-in-valve implantation. The hemodynamics results were good in all cases, without significant differences between the two groups. The procedures' durations and fluoroscopy times were significantly reduced in the MTG (48.1 versus 82.6 min, p < 0.0001; 15.2 versus 29.8 min, p = 0.0002). During follow-up, neither stent fracture nor valve dysfunction was noticed in either group. CONCLUSION: PPVI without prestenting and with a protective delivery method of the SAPIEN 3 valve significantly reduces the procedure's complexity, the duration, and the irradiation while maintaining excellent hemodynamics results in selected cases.
RESUMO
BACKGROUND: The Amplatzer™ Trevisio™ Intravascular Delivery System (Trevisio DS; Abbott Laboratories, Chicago, IL, USA) facilitates the delivery of Amplatzer™ Occluders and features an ultraflexible tip, which improves assessment of occluder position before release. AIMS: To assess the safety and efficacy of the Trevisio DS for transcatheter closure of patent foramen ovale and atrial septal defect. METHODS: The Amplatzer™ Trevisio™ Intravascular Delivery System Post-Approval Study was a prospective, postmarket, single-arm, multicentre, observational study of the Trevisio DS. Enrolled patients were indicated for transcatheter closure of patent foramen ovale or atrial septal defect. In all procedures, the Trevisio DS was used to deliver Amplatzer™ Occluders. Technical success was defined as successful deployment and release of at least one occluder. Device- or procedure-related serious adverse events were tracked until discharge or day 7, whichever occurred earlier. RESULTS: The study enrolled 144 patients with patent foramen ovale and 107 patients with atrial septal defect at 22 European sites; 53 patients with atrial septal defect (49.6%) were aged<18years. The rate of technical success was 98.4% (97.2% for atrial septal defect, 99.3% for patent foramen ovale). There was one serious adverse event (0.4%), an acute periprocedural device embolization that occurred after occluder release in a patient with atrial septal defect; the device was retrieved percutaneously. This was determined by the implanter to be unrelated to the performance of the Trevisio DS. CONCLUSIONS: The Trevisio DS exhibited a high rate of technical success and an excellent safety profile during transcatheter closure of patent foramen ovale and atrial septal defect.