Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599688

RESUMO

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Estudos Multicêntricos como Assunto , Sistema de Registros
2.
Int J Cardiol ; 405: 131934, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38437953

RESUMO

AIMS: T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter. METHODS AND RESULTS: The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted. CONCLUSIONS: In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation. CONDENSED ABSTRACT: The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.


Assuntos
Cateterismo Cardíaco , Sistema de Registros , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Masculino , Feminino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Idoso , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Pessoa de Meia-Idade , Ecocardiografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA