Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Card Fail ; 30(4): 580-591, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37625581

RESUMO

BACKGROUND: Venous congestion (VC) is a hallmark of symptomatic heart failure (HF) requiring hospitalization; however, its role in the pathogenesis of HF progression remains unclear. We investigated whether peripheral VC exacerbates inflammation, oxidative stress and neurohormonal and endothelial cell (EC) activation in patients with HF with reduced ejection fraction (HFrEF). METHODS AND RESULTS: Two matched groups of patients with HFrEF and with no peripheral VC vs without recent HF hospitalization were studied. We modeled peripheral VC by inflating a cuff around the dominant arm, targeting ∼ 30 mmHg increase in venous pressure (venous stress test [VST]). Blood and ECs were sampled before and after 90 minutes of VST. We studied 44 patients (age 53 ± 12 years, 32% female). Circulating endothelin-1, tumor necrosis factor-α, interleukin-6, isoprostane, angiotensin II (ang-2), angiopoietin-2, vascular cell adhesion molecule-1, and CD146 significantly increased after the VST. Enhanced endothelin-1 and angiopoietin-2 responses to the VST were present in patients with vs without recent hospitalization and were prospectively associated with incident HF-related events; 6698 messenger ribonucleic acid (mRNA probe sets were differentially expressed in ECs after VST. CONCLUSIONS: Experimental VC exacerbates inflammation, oxidative stress, neurohormonal and EC activation and promotes unfavorable transcriptome remodeling in ECs of patients with HFrEF. A distinct biological sensitivity to VC appears to be associated with high risk for HF progression.


Assuntos
Insuficiência Cardíaca Sistólica , Insuficiência Cardíaca , Hiperemia , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Masculino , Angiopoietina-2/metabolismo , Endotelina-1 , Volume Sistólico , Inflamação , Células Endoteliais , Estresse Oxidativo
2.
Physiol Rep ; 5(6)2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28320895

RESUMO

Endothelin-1 (ET-1) is a pivotal mediator of vasoconstriction and inflammation in congestive states such as heart failure (HF) and chronic kidney disease (CKD). Whether peripheral venous congestion (VC) increases plasma ET-1 at pressures commonly seen in HF and CKD patients is unknown. We seek to characterize whether peripheral VC promotes time- and dose-dependent increases in plasma ET-1 and whether these changes are sustained after decongestion. We used a randomized, cross-over design in 20 healthy subjects (age 30 ± 7 years). To experimentally model VC, venous pressure was increased to either 15 or 30 mmHg (randomized at first visit) above baseline by inflating a cuff around the subject's dominant arm; the nondominant arm served as a noncongested control. We measured plasma ET-1 at baseline, after 20, 60 and 120 min of VC, and finally at 180 min (60 min after cuff release and decongestion). Plasma ET-1 progressively and significantly increased over 120 min in the congested arm relative to the control arm and to baseline values. This effect was dose-dependent: ET-1 increased by 45% and 100% at VC doses of 15 and 30 mmHg, respectively (P < 0.05), and declined after 60 min of decongestion though remaining significantly elevated compared to baseline. In summary, peripheral VC causes time- and dose-dependent increases in plasma ET-1. Of note, the lower dose of 15 mmHg (more clinically relevant to HF and CKD patients) was sufficient to raise ET-1. These findings support the potentially contributory, not merely consequential, role of VC in the pathophysiology of HF and CKD.


Assuntos
Endotelina-1/sangue , Vasoconstrição/fisiologia , Pressão Venosa/fisiologia , Adulto , Estudos Cross-Over , Feminino , Humanos , Masculino , Fatores de Tempo , Adulto Jovem
3.
Eur Heart J ; 35(7): 448-54, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24265434

RESUMO

AIMS: Volume overload and venous congestion are typically viewed as a consequence of advanced and of acute heart failure (HF) and renal failure (RF) although it is possible that hypervolaemia itself might be a critical intermediate in the pathophysiology of these diseases. This study aimed at elucidating whether peripheral venous congestion is sufficient to promote changes in inflammatory, neurohormonal, and endothelial phenotype similar to those observed in HF and RF. METHODS: To experimentally model peripheral venous congestion, we developed a new method (so-called venous stress test) and applied the methodology on 24 healthy subjects (14 men, age 35 ± 2 years). Venous arm pressure was increased to ∼30 mmHg above the baseline level by inflating a tourniquet cuff around the dominant arm (test arm). Blood and endothelial cells (ECs) were sampled from test and control arm (lacking an inflated cuff) before and after 75 min of venous congestion, using angiocatheters and endovascular wires. Magnetic beads coated with EC-specific antibodies were used for EC separation; amplified mRNA was analysed by Affymetrix HG-U133 Plus 2.0 Microarray. RESULTS: Plasma interleukin-6 (IL-6), endothelin-1 (ET-1), angiotensin II (AII), vascular cell adhesion molecule-1 (VCAM-1), and chemokine (C-X-C motif) ligand 2 (CXCL2) were significantly increased in the congested arm. A total of 3437 mRNA probe sets were differentially expressed (P < 0.05) in venous ECs before vs. after testing, including ET-1, VCAM-1, and CXCL2. CONCLUSION: Peripheral venous congestion causes release of inflammatory mediators, neurohormones, and activation of ECs. Overall, venous congestion mimicked, notable aspects of the phenotype typical of advanced and of acute HF and RF.


Assuntos
Células Endoteliais/metabolismo , Endotélio Vascular/metabolismo , Insuficiência Cardíaca/etiologia , Hiperemia/fisiopatologia , Neurotransmissores/metabolismo , Vasculite/etiologia , Adulto , Angiotensina II/metabolismo , Braço/irrigação sanguínea , Citocinas/metabolismo , Feminino , Voluntários Saudáveis , Humanos , Masculino , Neuropeptídeos/metabolismo , RNA Mensageiro/metabolismo , Molécula 1 de Adesão de Célula Vascular/metabolismo
4.
Circ Heart Fail ; 6(5): 1005-12, 2013 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-23811966

RESUMO

BACKGROUND: Doppler ultrasound is the clinical gold standard for noninvasive blood pressure (BP) measurement among continuous-flow left ventricular assist device patients. The relationship of Doppler BP to systolic BP (SBP) and mean arterial pressure (MAP) is uncertain and Doppler measurements require a clinic visit. We studied the relationship between Doppler BP and both arterial-line (A-line) SBP and MAP. Validity and reliability of the Terumo Elemano BP Monitor, a novel slow cuff-deflation device that could potentially be used by patients at home, were assessed. METHODS AND RESULTS: Doppler and Terumo BP measurements were made in triplicate among 60 axial continuous-flow left ventricular assist device (HeartMate II) patients (30 inpatients and 30 outpatients) at 2 separate exams (360 possible measurements). A-line measures were also obtained among inpatients. Mean absolute differences (MADs) and correlations were used to determine within-device reliability (comparison of second and third BP measures) and between-device validity. Bland-Altman plots assessed BP agreement between A-line, Doppler BP, and Terumo Elemano. Success rates for Doppler and Terumo Elemano were 100% and 91%. Terumo Elemano MAD for repeat SBP and MAP were 4.6±0.6 and 4.2±0.6 mm Hg; repeat Doppler BP MAD was 2.9±0.2 mm Hg. Mean Doppler BP was lower than A-line SBP by 4.1 (MAD=6.4±1.4) mm Hg and higher than MAP by 9.5 (MAD=11.0±1.2) mm Hg; Terumo Elemano underestimated A-line SBP by 0.3 (MAD=5.6±0.9) mm Hg and MAP by 1.7 (MAD=6.0±1.0) mm Hg. CONCLUSIONS: Doppler BP more closely approximates SBP than MAP. Terumo Elemano was successful, reliable, and valid when compared with A-line and Doppler.


Assuntos
Pressão Arterial , Determinação da Pressão Arterial/instrumentação , Insuficiência Cardíaca/terapia , Coração Auxiliar , Esfigmomanômetros , Idoso , Análise de Variância , Diástole , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Modelos Lineares , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Sístole , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA