J Nucl Med ; 65(8): 1320-1326, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38871391

RESUMO

The collaboration of Yale, the University of California, Davis, and United Imaging Healthcare has successfully developed the NeuroEXPLORER, a dedicated human brain PET imager with high spatial resolution, high sensitivity, and a built-in 3-dimensional camera for markerless continuous motion tracking. It has high depth-of-interaction and time-of-flight resolutions, along with a 52.4-cm transverse field of view (FOV) and an extended axial FOV (49.5 cm) to enhance sensitivity. Here, we present the physical characterization, performance evaluation, and first human images of the NeuroEXPLORER. Methods: Measurements of spatial resolution, sensitivity, count rate performance, energy and timing resolution, and image quality were performed adhering to the National Electrical Manufacturers Association (NEMA) NU 2-2018 standard. The system's performance was demonstrated through imaging studies of the Hoffman 3-dimensional brain phantom and the mini-Derenzo phantom. Initial 18F-FDG images from a healthy volunteer are presented. Results: With filtered backprojection reconstruction, the radial and tangential spatial resolutions (full width at half maximum) averaged 1.64, 2.06, and 2.51 mm, with axial resolutions of 2.73, 2.89, and 2.93 mm for radial offsets of 1, 10, and 20 cm, respectively. The average time-of-flight resolution was 236 ps, and the energy resolution was 10.5%. NEMA sensitivities were 46.0 and 47.6 kcps/MBq at the center and 10-cm offset, respectively. A sensitivity of 11.8% was achieved at the FOV center. The peak noise-equivalent count rate was 1.31 Mcps at 58.0 kBq/mL, and the scatter fraction at 5.3 kBq/mL was 36.5%. The maximum count rate error at the peak noise-equivalent count rate was less than 5%. At 3 iterations, the NEMA image-quality contrast recovery coefficients varied from 74.5% (10-mm sphere) to 92.6% (37-mm sphere), and background variability ranged from 3.1% to 1.4% at a contrast of 4.0:1. An example human brain 18F-FDG image exhibited very high resolution, capturing intricate details in the cortex and subcortical structures. Conclusion: The NeuroEXPLORER offers high sensitivity and high spatial resolution. With its long axial length, it also enables high-quality spinal cord imaging and image-derived input functions from the carotid arteries. These performance enhancements will substantially broaden the range of human brain PET paradigms, protocols, and thereby clinical research applications.


Assuntos
Encéfalo , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Encéfalo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Processamento de Imagem Assistida por Computador , Fluordesoxiglucose F18
2.
Med Phys ; 49(4): 2642-2651, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35106784

RESUMO

PURPOSE: The positron range and prompt gamma emission are distinctive with different positron emitters. The performance assessment of an integrated PET/MR scanner with these positron emitters is required for related applications, as the magnetic field interferes with the positron propagation. Such an assessment is to be performed on the United Imaging uPMR 790-integrated PET/MR system. METHODS: The performance measurement methods were modified based on NEMA NU 2-2012, involving 18 F, 64 Cu, 68 Ga, 89 Zr, and 124 I as positron emitters. The NEMA IEC phantom was used for evaluations of image qualities. An agarose cap was wrapped around the point source for tissue-simulating spatial resolution measurement. The count rate performance was assessed with selected positron emitters. Images of a 3D-printed Derenzo phantom and representative patients were also acquired. RESULTS: The image quality measurement showed that all five positron emitters were suitable for the PET/MR system studied. However, due to the magnetic field, the image of the point source showed an elongated comet-tail feature, which could be eliminated by a tissue-simulating cap. This effect is more obvious in 124 I and 68 Ga, due to their long positron ranges. The imaging ability with various positron emitters was further validated with the count rate assessment, the Derenzo phantom, and the clinical images. CONCLUSIONS: Different positron emitters could be effectively imaged by the PET/MR system tested. The resolution measurement strategy proposed could be applied to measure PET spatial resolution in the magnetic field.


Assuntos
Elétrons , Tomografia por Emissão de Pósitrons , Humanos , Campos Magnéticos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos
3.
Phys Med Biol ; 66(20)2021 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-34544074

RESUMO

Absolute quantification of regional tissue concentration of radioactivity in positron emission tomography (PET) is a critical parameter-of-interest across various clinical and research applications and is affected by a complex interplay of factors including scanner calibration, data corrections, and image reconstruction. The emergence of long axial field-of-view (FOV) PET systems widens the dynamic range accessible to PET and creates new opportunities in reducing scan time and radiation dose, delayed or low radioactivity imaging, as well as kinetic modeling of the entire human. However, these imaging regimes impose challenging conditions for accurate quantification due to constraints from image reconstruction, low count conditions, as well as large and rapidly changing radioactivity distribution across a large axial FOV. We comprehensively evaluated the quantitative accuracy of the uEXPLORER total-body scanner in conditions that encompass existing and potential imaging applications (such as dynamic imaging and ultralow-dose imaging) using a set of total-body specific phantom and human measurements. Through these evaluations we demonstrated a relative count rate accuracy of ±3%-4% using the NEMA NU 2-2018 protocol, an axial uniformity spread of ±3% across the central 90% axial FOV, and a 3% activity bias spread from 17 to 474 MBq18F-FDG in a 210 cm long cylindrical phantom. Region-of-interest quantification spread of 1% was found by simultaneously scanning three NEMA NU 2 image quality phantoms, as well as relatively stable volume-of-interest quantification across 0.2%-100% of total counts through re-sampled datasets. In addition, an activity bias spread of -2% to +1% post-bolus injections in human subjects was found. Larger bias changes during the bolus injection phase in humans indicated the difficulty in providing accurate PET data corrections for complex activity distributions across a large dynamic range. Our results overall indicated that the quantitative performance achieved with the uEXPLORER scanner was uniform across the axial FOV and provided the accuracy necessary to support a wide range of imaging applications.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Fluordesoxiglucose F18 , Humanos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Tomógrafos Computadorizados