Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Cardiovasc Diabetol ; 23(1): 52, 2024 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-38310281

RESUMO

BACKGROUND: The outcomes of percutaneous coronary intervention (PCI) in diabetic patients are still suboptimal, and it is unclear if diabetic patients might derive a benefit from the use of drug-coated balloons. AIMS: To evaluate the impact of diabetes mellitus on the outcomes of patients undergoing PCI with sirolimus-coated balloon (SCB) MagicTouch (Concept Medical, India). METHODS: We conducted a subgroup analysis of the prospective, multicenter, investigator-initiated EASTBOURNE registry, evaluating the performance of MagicTouch SCB in patients with and without diabetes. The study primary endpoint was target lesion revascularization (TLR) at 12-month follow-up. Secondary clinical endpoints were major adverse clinical events (MACE), death, myocardial infarction (MI), and BARC 2-5 bleedings. RESULTS: Among 2,083 enrolled patients, a total of 864 suffered from diabetes (41.5%). Patients with diabetes had a numerically higher occurrence of TLR (6.5% vs. 4.7% HR 1.38, 95%CI 0.91-2.08), all-cause death (3.8% vs. 2.6%, HR 1.81, 95%CI 0.95-3.46), and MACE (12.2% vs. 8.9%; HR 1.26 95%CI 0.92-1.74). The incidence of spontaneous MI was significantly higher among diabetic patients (3.4% vs. 1.5%, HR 2.15 95%CI 1.09-4.25); bleeding events did not significantly differ. The overall incidence of TLR was higher among in-stent restenosis (ISR) as compared to de-novo coronary lesions, irrespectively from diabetes status. CONCLUSIONS: In the EASTBOURNE DIABETES registry, diabetic patients treated with the MagicTouch SCB did not have a significant increase in TLR when compared to non-diabetic patients; moreover, diabetic status did not affect the study device performance in terms of TLR, in both de-novo lesions and ISR.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Diabetes Mellitus , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Sirolimo/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/induzido quimicamente , Sistema de Registros , Reestenose Coronária/epidemiologia , Reestenose Coronária/etiologia
2.
Catheter Cardiovasc Interv ; 103(4): 532-538, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38415895

RESUMO

BACKGROUND: Studies evaluating the safety and efficacy of drug coating balloons (DCB) for the treatment of lesions in large coronary vessel are limited. AIMS: Our study aimed to evaluate the performance of a sirolimus DCB in large coronary arteries. METHODS: We analyzed all the procedures included in the EASTBOURNE Registry (NCT03085823) enrolling patients with a clinical indication to percutaneous coronary intervention performed by a sirolimus DCB according to investigator judgment. In the present analysis, a cut-off of 2.75 mm was used to define large coronary arteries. Primary endpoint of the study was clinically driven target lesion revascularization (TLR) at 24 months whereas secondary endpoint included procedural success, myocardial infarction (MI), cardiac death and total mortality. RESULTS: Among the 2123 patients and 2440 lesions enrolled in the EASTBOURNE study between 2016 and 2020, 757 patients/810 lesions fulfilled the criteria for the present analysis. Mean reference vessel diameter was 3.2 ± 0.3 mm with mean lesion length of 22 ± 7 mm. Procedural success was high (96%) and at 2-year follow up the device showed a good efficacy with a TLR rate of 9%. There were 34 deaths (4.5%), 30 MIs (4%) and 8 BARC type 3-5 bleedings (1.1%). In-stent restenosis (629 lesions) and de novo lesions (181) were associated with 11% and 4% rates of TLR at 2 years, respectively (p = 0.003). CONCLUSIONS: Clinical performance of a sirolimus DCB in large coronary artery vessels shows promising signals at 2-year follow up, both in de novo and in-stent restenosis lesions.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Sirolimo/efeitos adversos , Resultado do Tratamento , Angiografia Coronária , Materiais Revestidos Biocompatíveis
3.
JACC Cardiovasc Interv ; 16(14): 1794-1803, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37495352

RESUMO

BACKGROUND: Drug-coated balloons (DCB) represent 1 of the most promising innovations in interventional cardiology and may represent a valid alternative to drug-eluting stents. Currently, some sirolimus-coated balloons (SCB) are being investigated for several coronary artery disease applications. OBJECTIVES: This study sought to understand the role of a novel SCB for the treatment of coronary artery disease. METHODS: EASTBOURNE (All-Comers Sirolimus-Coated Balloon European Registry) is a prospective, multicenter, investigator-driven clinical study that enrolled real-world patients treated with SCB. Primary endpoint was target lesion revascularization (TLR) at 12 months. Secondary endpoints were procedural success, myocardial infarction (MI), all-cause death, and major adverse clinical events (a composite of death, MI, and TLR). All adverse events were censored and adjudicated by an independent clinical events committee. RESULTS: A total population of 2,123 patients (2,440 lesions) was enrolled at 38 study centers in Europe and Asia. The average age was 66.6 ± 11.3 years, and diabetic patients were 41.5%. De novo lesions (small vessels) were 56%, in-stent restenosis (ISR) 44%, and bailout stenting occurred in 7.7% of the patients. After 12 months, TLR occurred in 5.9% of the lesions, major adverse clinical events in 9.9%, and spontaneous MI in 2.4% of the patients. The rates of cardiac/all-cause death were 1.5% and 2.5%, respectively. The primary outcome occurred more frequently in the ISR cohort (10.5% vs 2.0%; risk ratio: 1.90; 95% CI: 1.13-3.19). After multivariate Cox regression model, the main determinant for occurrence of the primary endpoint was ISR (OR: 5.5; 95% CI: 3.382-8.881). CONCLUSIONS: EASTBOURNE, the largest DCB study in the coronary field, shows the safety and efficacy of a novel SCB in a broad population of coronary artery disease including small vessels and ISR patients at mid-term follow-up. (The All-Comers Sirolimus-Coated Balloon European Registry [EASTBOURNE]; NCT03085823).


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Reestenose Coronária , Infarto do Miocárdio , Humanos , Pessoa de Meia-Idade , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Angioplastia Coronária com Balão/efeitos adversos , Sirolimo/efeitos adversos , Resultado do Tratamento , Infarto do Miocárdio/complicações , Sistema de Registros , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia
4.
J Cardiovasc Med (Hagerstown) ; 22(2): 94-100, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32740442

RESUMO

AIMS: The purpose of the EASTBOURNE registry is to evaluate the immediate and long-term clinical performance of a novel sirolimus-coated balloon (SCB) in a real-world population of patients with coronary artery disease. We here present the prespecified interim analysis after the enrollment of the first 642 patients who obtained 1-year clinical follow-up. METHODS: EASTBOURNE is a prospective, international, multicenter, all-comer investigator-driven clinical registry, which is enrolling consecutive patients treated with SCB at 42 European and Asiatic centers. Primary study endpoint is target-lesion revascularization (TLR) at 12 months. Secondary endpoints are procedural success and major adverse cardiac events through 36 months. RESULTS: Diabetes mellitus was present in 41% of patients. Acute coronary syndrome was present in 45% of patients and de novo lesions were 55%; 83% of the in-stent restenosis (ISR) patients had drug-eluting stents restenosis. Lesion predilatation was performed in 95% of the cases and bailout stenting occurred in 7.5%. So far, 642 patients have a complete 12-month follow-up. TLR occurred in 2.5%, myocardial infarction in 2.3%, total death in 1% and major adverse cardiac events in 5.8% of patients. A prespecified analysis of comparison between ISR and de-novo lesions showed a significantly higher occurrence of TLR in the ISR population (5.4 vs. 0.2%, P = 0.0008). CONCLUSION: The current interim analysis of 12-month follow-up of the EASTBOURNE registry shows good immediate performance and an adequate and encouraging safety profile through 12 months for this novel SCB.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Sistema de Registros , Sirolimo/farmacologia , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Masculino , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA