Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Vasa ; 36(2): 100-6, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17708101

RESUMO

BACKGROUND: The pathogenesis of atherosclerosis comprises endothelial dysfunction, thickening as well as impaired compliance of the arterial vessel wall. Early assessment of these alterations of the vessel wall at the same site of the vascular tree has yet been hampered by the lack of highly sensitive diagnostic approaches suitable for clinical routine. We therefore aimed to develop and validate a single non-invasive examination of the brachial artery for simultaneous and highly accurate measurement of functional, structural and physicomechanical parameters of the brachial artery. PATIENTS AND METHODS: 20 healthy individuals were investigated using high resolution ultrasound. Flow-mediated dilation (FMD), fractional diameter changes (FDC) and intima-media-thickness (IMT) were measured in the same segment of the brachial artery. Coefficients of variation, day-to-day-variability, between- and within-observer-variability were investigated in 5 individuals. All measurements were performed manually and by an automated PC-based analyzing system. RESULTS: Mean values for all measured parameters were 7.65 +/- 0.8% for FMD, 0.02 +/- 0.002 for FDC, 0.351 +/- 0.007 mm for IMT and followed an even distribution throughout the study population. Automated analysis of coefficient of variation, day-to-day-, between- and within-observer variabilities were: 0. 78%, 1.3%, 0.8%, 0.8% (FMD); 4.7%, 2.8%, 4.2%, 2.7% (FDC); 1.8%, 1.1%, 1.9%, 1.1% (IMT). Coefficient of variation, day-to-day-, between- and within-observer variabilities for the manual readings were significantly higher. CONCLUSIONS: Functional, structural and physicomechanical parameters of the brachial artery can be quantified consecutively, time-saving and highly reproducibly as an "one-stop-shop" in a single session using high resolution ultrasound with digitized post-processing. This highlights the future possibility of early, sensitive and non-invasive diagnostic testing of vascular function in patients prone to vascular disease.


Assuntos
Aterosclerose/diagnóstico por imagem , Artéria Braquial/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/instrumentação , Ultrassonografia/instrumentação , Adulto , Aterosclerose/fisiopatologia , Artéria Braquial/fisiopatologia , Feminino , Humanos , Masculino , Computação Matemática , Pessoa de Meia-Idade , Músculo Liso Vascular/diagnóstico por imagem , Músculo Liso Vascular/fisiopatologia , Valores de Referência , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/fisiopatologia , Túnica Média/diagnóstico por imagem , Túnica Média/fisiopatologia , Vasodilatação/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA