Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 243: 116109, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38518458

RESUMO

An innovative ecofriendly high-performance thin layer chromatographic (HPTLC) method with spectrophotometric detection for simultaneous determination of Tramadol (TMD), Tapentadol (TAP), and Venlafaxine (VEN) in seized dosage forms was presented. Our method was conducted to achieve separation following the optimal conditions: pre-coated silica gel plates using a green mobile phase (heptane: acetone: ammonia, 7:3:0.5 v/v), with absorbance scanning at 272 nm. The validation of the method was done following International Conference on Harmonization (ICH) guidelines, demonstrates linearity, accuracy, precision, selectivity, robustness, and system suitability. Separation was achieved with a detection limit of 0.34, 0.16, and 0.084 (ug/band) for TMD, TAP, and VEN, respectively, the method successfully analyzes seized samples. Trueness is confirmed through a high degree of similarity between HPTLC and gas chromatography results. The study's ecofriendly approach, simplicity, and selectivity position it as a promising method for efficient, on-site monitoring of seized samples.


Assuntos
Tramadol , Tapentadol , Cloridrato de Venlafaxina , Cromatografia em Camada Fina/métodos , Preparações Farmacêuticas , Reprodutibilidade dos Testes
2.
Biomed Chromatogr ; 29(7): 998-1007, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25417559

RESUMO

The prerequisites for forensic confirmatory analysis by LC/MS/MS with respect to European Union guidelines are chromatographic separation, a minimum number of two MS/MS transitions to obtain the required identification points and predefined thresholds for the variability of the relative intensities of the MS/MS transitions (MRM transitions) in samples and reference standards. In the present study, a fast, sensitive and robust method to quantify tramadol, chlorpheniramine, dextromethorphan and their major metabolites, O-desmethyltramadol, dsmethyl-chlorpheniramine and dextrophan, respectively, in human plasma using ibuprofen as internal standard (IS) is described. The analytes and the IS were extracted from plasma by a liquid-liquid extraction method using ethyl acetate-diethyl-ether (1:1). Extracted samples were analyzed by ultra-high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS). Chromatographic separation was performed by pumping the mobile phase containing acetonitrile, water and formic acid (89.2:11.7:0.1) for 2.0 min at a flow rate of 0.25 µL/min into a Hypersil-Gold C18 column, 20 × 2.0 mm (1.9 µm) from Thermoscientific, New York, USA. The calibration curve was linear for the six analytes. The intraday precision (RSD) and accuracy (RE) of the method were 3-9.8 and -1.7-4.5%, respectively. The analytical procedure herein described was used to assess the pharmacokinetics of the analytes in 24 healthy volunteers after a single oral dose containing 50 mg of tramadol hydrochloride, 3 mg chlorpheniramine maleate and 15 mg of dextromethorphan hydrobromide.


Assuntos
Clorfeniramina/sangue , Cromatografia Líquida de Alta Pressão/métodos , Dextrometorfano/sangue , Espectrometria de Massas em Tandem/métodos , Tramadol/sangue , Clorfeniramina/química , Clorfeniramina/farmacocinética , Dextrometorfano/química , Dextrometorfano/farmacocinética , Estabilidade de Medicamentos , Humanos , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Tramadol/química , Tramadol/farmacocinética
3.
J Chromatogr Sci ; 50(10): 855-61, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22879356

RESUMO

High-performance liquid chromatography (HPLC) and chemometric methods were applied to the simultaneous determination of the two nonsteroidal antifungal drugs, miconazole (MIC) and nystatin (NYS). The applied chemometric techniques are multivariate methods including classical least squares, principal component regression and partial least squares methods. The ultraviolet (UV) absorption spectra of the standard solutions of the training and validation sets in methanol are recorded in the range of 280-320 nm at 0.2-nm intervals. The HPLC method depends on reversed-phase separation using a C18 column. The mobile phase consists of a mixture of methanol-acetonitrile-ammonium acetate buffer (pH 6; 50 mM) (60:30:10 v/v/v). The UV detector was set at 230 nm. The developed methods were validated and successfully applied to the simultaneous determination of MIC and NYS in their tablets. The assay results obtained using the chemometric methods were statistically compared to those of the HPLC method and good agreement was observed.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Miconazol/análise , Nistatina/análise , Análise dos Mínimos Quadrados , Análise de Componente Principal , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta/métodos , Supositórios/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA