11.
Indian J Ophthalmol ; 71(3): 707-716, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36872665

RESUMO

This review aimed to compare the outcomes of Descemet's membrane endothelial keratoplasty (DMEK) in combination with (category 1), before (category 2), or after cataract surgery (category 3) in patients with Fuchs' endothelial dystrophy (FED). Primary outcome was gain in best-corrected log of minimum angle of resolution (logMAR) visual acuity (BCVA). Secondary outcomes were graft detachment, rebubbling rates, rejection, failure, and endothelial cell loss (ECL). In category 1, 2, and 3, 12 studies (N = 1932) were included (five in category 1 [n = 696], one in category 2 [n = 286], and two in category 3 [n = 950], and the remaining four compared between two of the three categories). At 6 months, the gain in BCVA was 0.34 ± 0.04, 0.25 ± 0.03, and 0.38 ± 0.03 logMAR in category 1, 2, and 3, respectively. The difference was significant between categories 1 and 2 (Chi2 = 11.47, P < 0.01) and categories 2 and 3 (Chi2 = 35.53, P < 0.01). At 12 months, the gain in BCVA was 0.52 ± 0.05 and 0.38 ± 0.06 logMAR in categories 1 & 3 (Chi2 = 14.04, P < 0.01). The rebubbling rates were 15%, 4%, and 10% (P < 0.01) and the graft detachment rates were 31%, 8%, and 13% (P < 0.01) in categories 1, 2, and 3, respectively. However, graft rejection, survival rates, and ECL at 12 months were not different between categories 1 and 3. There is low certainty evidence that gain in BCVA in category 1 was comparable to category 3 at 6 months; however, it was significantly better with category 3 at 12 months. Although rebubbling and graft detachment rates were highest in category 1, there was no significant difference in graft rejection, survival rates, and ECL. Further high-quality studies are likely to change the effect estimate and have an impact on the confidence of the estimate.


Assuntos
Extração de Catarata , Catarata , Transplante de Córnea , Distrofia Endotelial de Fuchs , Humanos , Lâmina Limitante Posterior
14.
Eye (Lond) ; 37(2): 290-296, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35058602

RESUMO

BACKGROUND: This study aims to assess whether ophthalmic surgical skills can be taught successfully online to a diverse international and interprofessional student group. METHODS: Mixed methods study involving 20 students and 5 instructors. Each student completed a pre-session and post-session questionnaire to assess their perceptions regarding online instruction. Changes in questionnaire responses were analysed using Wilcoxon signed rank (SPSS 25). Semi-structured interviews were conducted to assess instructor perceptions towards virtual surgical skills teaching. Thematic analysis was undertaken using NVivo 12.0 software. RESULTS: There was a 100% completion rate of pre- and post-session questionnaires. Prior to the session, lack of instructor supervision and inability to provide constructive feedback were emergent themes from students. Pre-session concerns regarding online delivery: 40% of students thought their view of skills demonstration would be negatively impacted, 60% their level of supervision and 55% their interaction with instructors. Following the session 10%, 15% and 5% held this view respectively. All students were 'satisfied' or 'very satisfied' regarding the 'Surgeon's View' camera angle as well as the use of breakout rooms. 75% perceived an improvement in their confidence in instrument handling, 80% in cable knot tying and 70% in suture tying. Overall student rating for the virtual surgical skills session was 8.85 (±1.19) out of 10 (10 being most satisfied). CONCLUSIONS: We demonstrate that successful delivery of a virtual ophthalmic surgical skills course is feasible. We were able to widen accessibility and participation through virtual delivery, which has future implications for ophthalmic surgical teaching and its reach.


Assuntos
Competência Clínica , Procedimentos Cirúrgicos Oftalmológicos , Humanos
15.
BMJ Open ; 12(8): e059350, 2022 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-35981777

RESUMO

INTRODUCTION: Multifocal intraocular lens (IOLs) are used to restore vision at different focal distances. The technology of multifocal IOLs is continually advancing. Optical aberrations a property of lenses that causes spreading of light over a region resulting in a blurred or distorted image. This study aims to systematically review investigator measured and patient reported optical aberrations following implantation of multifocal IOLs during phacoemulsification surgery to treat presbyopia in adults. METHODS AND ANALYSIS: We will conduct an electronic database search for randomised controlled trials, prospective non-randomised studies, observational studies in Ovid MEDLINE, Ovid EMBASE, Cochrane Central Register of Controlled Trials (CENTRAL), Web of Science, Scopus and ClinicalTrials.gov in March 2021. Eligibility criteria will include quantitative articles written in English and containing data on optical aberrations. Two independent reviewers will screen titles and abstracts and extract data from full texts, reporting outcomes according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Data extraction of key characteristics will be completed using customised forms. Methodological quality will be assessed using Cochrane Handbook 6.2. ETHICS AND DISSEMINATION: Ethics approval is not required for this review, as it will only include published data. Findings will be published in a peer-reviewed journal and disseminated across ophthalmic networks. We anticipate that the findings of this work will be of interest to multiple stakeholders: people who have undergone cataract surgery, eye health professionals, ophthalmic surgeons, device manufacturers and policy-makers. It will also inform researchers to where there are gaps in evidence and identify areas for future research. PROSPERO REGISTRATION NUMBER: CRD42021271050.


Assuntos
Extração de Catarata , Lentes Intraoculares , Lentes Intraoculares Multifocais , Adulto , Humanos , Metanálise como Assunto , Estudos Prospectivos , Revisões Sistemáticas como Assunto , Acuidade Visual
17.
Ophthalmology ; 129(8): 841-855, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35331751

RESUMO

TOPIC: Corneal endothelial cell density (ECD) loss after glaucoma surgery with or without cataract surgery. CLINICAL RELEVANCE: Corneal ECD loss may occur as the result of intraoperative surgical trauma in glaucoma surgery or postoperatively with chronic endothelial cell trauma or irritation. METHODS: Glaucoma filtration surgery or microinvasive glaucoma surgery (MIGS) in participants with ocular hypertension, primary and secondary open-angle glaucoma, normal-tension glaucoma, and angle-closure glaucoma were included. Electronic databases searched in December 2021 included MEDLINE, Embase, Cochrane Central Register of Controlled Trials, ClinicalTrials.gov, the International Prospective Register of Systematic Reviews, Food and Drug Administration (FDA) Premarket Approval, and FDA 510(k). RESULTS: A total of 39 studies were included in quantitative synthesis. Twelve months after suprachoroidal MIGS, mean ECD loss was 282 cells/mm2 (95% confidence interval [CI], 220-345; P < 0.00001; chi-square = 0.06; I2 = 0%; 2 studies; very low certainty). Mean ECD loss after Schlemm's canal implantable devices was 338 cells/mm2 (95% CI, 185-491; P < 0.0001; chi-square = 0.08; I2 = 0%; 2 studies; low certainty) at 12 months. Mean ECD loss was 64 cells/mm2 (95% CI, 21-107; P = 0.004; chi-square = 4.55; I2 = 0%; 6 studies; low certainty) after Schlemm's canal procedures (without implantable devices) at 12 months. At 12 months, the mean ECD loss after trabeculectomy was 33 cells/mm2 (95% CI, -38 to 105, P = 0.36, chi-square = 1.17; I2 = 0%; moderate certainty). At 12 months, mean ECD loss was 121 cells/mm2 (95% CI, 53-189; P = 0.0005; chi-square = 3.00; I2 = 0%; 5 studies; low certainty) after Express (Alcon) implantation. When compared with the control fellow eye, aqueous shunt surgery reduced ECD by 5.75% (95% CI, -0.93 to 12.43; P = 0.09, chi-square = 1.32; I2 = 0%; low certainty) and 8.11% ECD loss (95% CI, 0.06-16.16 P = 0.05; chi-square = 1.93; I2 = 48%) at 12 and 24 months, respectively. CONCLUSIONS: Overall, there is low certainty evidence to suggest that glaucoma surgery involving long-term implants has a greater extent of ECD loss than glaucoma filtration surgeries without the use of implants. The results of this review support follow-up beyond 36 months to assess ECD loss and corneal decompensation after implantation of glaucoma drainage implants.


Assuntos
Catarata , Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Glaucoma , Catarata/complicações , Perda de Células Endoteliais da Córnea/diagnóstico , Perda de Células Endoteliais da Córnea/etiologia , Células Endoteliais , Glaucoma/cirurgia , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma de Ângulo Aberto/complicações , Glaucoma de Ângulo Aberto/cirurgia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA