Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Oman Med J ; 38(1): e471, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36825248

RESUMO

Soft tissue neoplasm is common among patients with neurofibromatosis type 1 (NF-1). We present a case of a middle-aged woman with NF-1 who presented with a painless, insidiously increasing perineal mass for the past eight months. She underwent colonoscopy, computed tomography staging, magnetic resonance imaging of the pelvis, core-needle biopsy, and later wide local excision of left perineum swelling. Histopathological examination showed a high-grade spindle cell sarcoma, which is a rare association among NF-1. Spindle cell sarcoma is a group of malignant soft tissue tumors with locally destructive growth with spindle-shaped neoplastic cells. The solitary spindle cell sarcoma of the perineum is rare, and wide local resection with a clear margin is the only treatment at present-the scarcely available evidence limiting the use of adjuvant chemotherapy, immunotherapy, and radiotherapy.

2.
Br J Nurs ; 31(22): S34-S42, 2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36519479

RESUMO

BACKGROUND: Choice of ostomy appliances is based on multiple factors including economic considerations, individual patient requirements and lifestyle. A recently launched two-piece ostomy collection device with an extended tape border is expected to provide a long wear time and increase patients' sense of security. AIMS AND METHODS: A randomised controlled, non-blinded, cross-over study involving 38 patients (with colostomies and ileostomies) compared the test device to a similar device from the same manufacturer but without the tape border. The main objective was to assess wear time for non-inferiority as a measure of efficacy. Secondary efficacy assessment included peristomal skin condition using the DET (discolouration, erosion and tissue growth) score and patient acceptability, which was assessed through questionnaires using Likert-scale options. Safety was assessed according to the incidence and intensity of device-related adverse events, and the condition of the peristomal skin. RESULTS AND CONCLUSION: Analysis of results in the per-protocol population showed an average wear time of 4.5 days for both devices and demonstrated non-inferiority. DET scores were similar in both groups, and both had low rates of device-related adverse events, all of which related to peristomal skin. Patients said the devices were user friendly. While the two devices are similar, some patients may find one with an adhesive tape more suited to their needs.


Assuntos
Estomia , Higiene da Pele , Humanos , Colostomia/efeitos adversos , Estudos Cross-Over , Estomia/efeitos adversos , Higiene da Pele/métodos
3.
Endosc Int Open ; 9(3): E289-E291, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33655023

RESUMO

Bowel obstruction is one of the most common surgical emergencies and a major cause of morbidity and mortality. Standard supportive measures must be instituted as soon as the diagnosis is confirmed. Anastomotic strictures are a benign etiology of intestinal obstruction, occurring in up to 22 % of patients following colorectal resection. Traditionally, endoscopic balloon dilation (EBD) has been the intervention of choice in such cases; however, it may not be feasible in all settings. We report a novel application of the AXIOS stent and electrocautery-enhanced delivery system (Boston Scientific, Marlborough, Massachusetts, United States) to create a colo-colostomy to bypass a sigmoid colon stricture in a 51-year-old woman who presented with acute intestinal obstruction. Despite stent dislodgment during the procedure, the preexisting tract allowed us to improvise our technique with a second LAMS placement. The patient was discharged well 48 hours after the procedure. However, 4 months later, she required a session of EBD following a presentation for fecal impaction. She is currently asymptomatic and being followed up regularly as an outpatient.

4.
BJR Case Rep ; 4(4): 20180017, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30931138

RESUMO

Barium enema investigation is regarded as a safe investigative procedure. Rarely, it may cause complications such as colonic perforation and barium intravasation. Barium intravasation may be caused by the inadvertent introduction of the catheter into the vagina, thereby into the vaginal venous plexus. It may also occur through mechanical colonic perforation with the catheter, or via diseased bowel conditions. This may lead to complications such as liver microabscesses, massive pulmonary embolism, hypovolemic shock, disseminated intravascular coagulopathy and even sudden death. With that in mind, we would like to report an interesting case of barium intravasation into the portal venous system via the vagina venous plexus. The patient experienced abdominal discomfort with mild per vaginal bleed and went into disseminated intravascular coagulopathy. She received supportive management and she made a full recovery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA