Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Vox Sang ; 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38946160

RESUMO

BACKGROUND AND OBJECTIVES: The detection of treponemal antibodies, which are used to make a diagnosis of syphilis, is important both for diagnostic purposes and as a mandatory blood donor test in most countries. We evaluated the feasibility of using Kode Technology to make syphilis peptide red cell kodecytes for use in column agglutination serologic platforms. MATERIALS AND METHODS: Candidate Kode Technology function-spacer-lipid (FSL) constructs were made for the Treponema pallidum lipoprotein (TmpA) of T. pallidum, using the peptide and FSL selection algorithms, and then used to make kodecytes. Developmental kodecytes were evaluated against a large range of syphilis antibody reactive and non-reactive samples in column agglutination platforms and compared against established methodologies. Overall, 150 reactive and 2072 non-reactive Syphicheck assay (a modified T. pallidum particle agglutination) blood donor samples were used to evaluate the agreement rate of the developed kodecyte assay. RESULTS: From three FSL-peptide candidate constructs, one was found to be the most suitable for diagnostics. Of 150 Syphicheck assay reactive samples, 146 were TmpA-kodecyte reactive (97.3% agreement), compared with 58.0% with the rapid plasmin reagin (RPR) assay for the same samples. Against the 2072 expected syphilis non-reactive samples the agreement rate for TmpA-kodecytes was 98.8%. CONCLUSION: TmpA-kodecytes are viable for use as cost-effective serologic reagent red cells for the detection of treponemal antibodies to diagnose syphilis with a high level of specificity in blood centres. This kodecyte methodology also potentially allows for introduction of the reverse-algorithm testing into low-volume laboratories, by utilizing existing transfusion laboratory infrastructure.

2.
Int J Mol Sci ; 25(11)2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38891913

RESUMO

Glycans of MVs are proposed to be candidates for mediating targeting specificity or at least promoting it. In contrast to exosomes, glycomic studies of MVs are largely absent. We studied the glycoprofile of endothelial cell-derived MVs using 21 plant lectins, and the results show the dominance of oligolactosamines and their α2-6-sialylated forms as N-glycans and low levels of α2-3-sialylated glycans. The low levels of α2-3-sialosides could not be explained by the action of extracellular glycosidases. Additionally, the level of some Man-containing glycans was also decreased in MVs. Spatial masking as the causative relationship between these low level glycans (as glycosphingolipids) by integral proteins or proteoglycans (thus, their lack of interaction with lectins) seems unlikely. The results suggest that integral proteins do not pass randomly into MVs, but instead only some types, differing in terms of their specific glycosylation, are integrated into MVs.


Assuntos
Células Endoteliais , Lectinas de Plantas , Polissacarídeos , Polissacarídeos/metabolismo , Polissacarídeos/química , Lectinas de Plantas/metabolismo , Lectinas de Plantas/química , Humanos , Células Endoteliais/metabolismo , Glicosilação , Micropartículas Derivadas de Células/metabolismo
5.
Transfusion ; 62(8): 1630-1635, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35761783

RESUMO

BACKGROUND: Training is essential to develop and maintain skills required to be a competent serologist, yet samples required to achieve this are often difficult to obtain. We evaluated the feasibility of SARS-CoV-2 peptide modified RBCs (1144-kodecytes) to develop simulated antibody screening and identification panels of reagent RBCs suitable for practical training, recognition, and grading of serologic reactions. STUDY DESIGN AND METHODS: RBCs from a single donor were modified into kodecytes using Kode Technology function-spacer-lipid constructs bearing a short SARS-CoV-2 peptide. Kodecytes and unmodified cells were then arranged in patterns representative of RBC antibody profiles as simulated antibody screening and identification reagent cell panels (SASID), and then tested against immune donor plasma samples containing SARS-CoV-2 antibodies. Manual tube and two different gel card serologic platforms were evaluated by routine techniques. SASID exemplars were created for antibodies including D, Cw , f (ce), Jka (strong, weak, dosing), mixtures of D + E, Jka + K, Fya + E, high and low frequency antibodies and a warm IgG autoantibody. RESULTS: Kodecytes (positive reactions) and unmodified cells (negative) when arranged and tested in appropriate patterns in SASID panels were able to mimic IgG antibody reactions, and were capable of measuring both accuracy and precision in reaction grading. CONCLUSIONS: Kodecytes can be used to rapidly create in-house simulated yet realistic antibody screening and identification panels suitable for large scale training in the recognition and grading of serologic reactions.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , COVID-19/diagnóstico , Eritrócitos , Humanos , Peptídeos , Plasma
6.
EJHaem ; 3(1): 72-79, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35464155

RESUMO

Surveillance of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic requires tests to monitor antibody formation and prevalence. We detected SARS-CoV-2 antibodies using red cells coated by Kode technology with short peptides derived from the SARS-CoV-2 spike protein (SP). Such modified red cells, called C19-kodecytes, can be used as reagent cells in any manual or automated column agglutination assay. We investigated the presence of SARS-CoV-2 antibodies in 130 samples from COVID-19 convalescent plasma donors using standard manual technique, two FDA-authorized enzyme-linked immunosorbent assay (ELISA) assays and a virus neutralisation assay. The sensitivity of the C19-kodecyte assay was 88%, comparable to the anti-SP and anti-nucleocapsid protein (NCP) ELISAs (86% and 83%) and the virus neutralisation assay (88%). The specificity of the C19-kodecyte assay was 90% (anti-SP 100% and anti-NCP 97%). Likewise, 231 samples from 73 vaccinated individuals were tested with an automated analyser, and we monitored the appearance and persistence of SARS-CoV-2 antibodies. The C19-kodecyte assay is a robust tool for SARS-CoV-2 antibody detection. Automated blood group analyser use enables large-scale SARS-CoV-2 antibody testing for vaccination monitoring in population surveys.

7.
Microbiol Spectr ; 9(3): e0083021, 2021 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-34878316

RESUMO

Red cells can be labeled with peptides from the SARS-CoV-2 spike protein (C-19 kodecytes) and used as reagent cells for serologic screening of SARS-CoV-2 antibodies. We evaluated 140 convalescent COVID-19 donors and 275 healthy controls using C19-kodecytes. The analytical performance of the C19-kodecyte assay was compared with a virus neutralizing assay and two commercial chemiluminescent antibody tests (Total assay and IgG assay, Ortho). The C19-kodecyte assay detected SARS-CoV-2 antibodies with a sensitivity of 92.8% and specificity of 96.3%, well within the minimum performance range required by FDA for EUA authorization of serologic tests. The Cohen's kappa coefficient was 0.90 indicating an almost perfect agreement with the Total assay. The Spearman's correlation coefficient was 0.20 with the neutralizing assay (0.49 with IgG, and 0.41 with Total assays). The limited correlation in assay reaction strengths suggested that the assays may be influenced by different antibody specificities. The C19-kodecyte assay is easily scalable and may vastly improve test capacity in any blood typing laboratory using its routine column agglutination platforms. IMPORTANCE We recently developed a red cell based assay to detect SARS-CoV-2 antibodies in human plasma. In the current study, we show the hands-on application of this assay in a group of COVID-19 convalescent plasma donors and healthy individuals. We compared our assay against three published assays, including two that are widely used for patient care in the United States. Our assay compared well with all three assays. Our easily scalable assay can be used for population-wide screening of SARS-CoV-2 antibody status. It can be readily established in any hospital blood bank worldwide using its routine equipment.


Assuntos
Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/imunologia , SARS-CoV-2/isolamento & purificação , Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , COVID-19/terapia , Agregação Celular , Humanos , Imunização Passiva , Imunoglobulina G/sangue , Sensibilidade e Especificidade , Glicoproteína da Espícula de Coronavírus/imunologia , Soroterapia para COVID-19
8.
medRxiv ; 2021 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-34494027

RESUMO

Surveillance of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic requires tests to monitor antibody formation and prevalence. We detected SARS-CoV-2 antibodies using red cells coated by Kode technology with short peptides derived from the SARS-CoV-2 spike protein. Such modified red cells, called C19-kodecytes, can be used as reagent cells in any manual or automated column agglutination assay. We investigated the presence of SARS-CoV-2 antibodies in 130 samples from COVID-19 convalescent plasma donors using standard manual technique, two FDA authorized ELISA assays and a virus neutralisation assay. The sensitivity of the C19-kodecyte assay was 88%, comparable to the anti-SP and anti-NCP ELISAs (86% and 83%) and the virus neutralisation assay (88%). The specificity of the C19-kodecyte assay was 90% (anti-SP 100% and anti-NCP 97%). Likewise, 231 samples from 73 vaccinated individuals were tested with an automated analyser and we monitored the appearance and persistence of SARS-CoV-2 antibodies. The C19-kodecyte assay is a robust tool for SARS-CoV-2 antibody detection. Automated blood group analyser use enables large-scale SARS-CoV-2 antibody testing for vaccination monitoring in population surveys.

9.
Bioconjug Chem ; 32(8): 1606-1616, 2021 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-34181851

RESUMO

In the near future, the increase in the number of required tests for COVID-19 antibodies is expected to be many hundreds of millions. Obviously, this will be done using a variety of analytical methods and using different antigens, including peptides. In this work, we compare three method variations for detecting specific immunoglobulins directed against peptides of approximately 15-aa of the SARS-CoV-2 spike protein. These linear peptide epitopes were selected using antigenicity algorithms, and were synthesized with an additional terminal cysteine residue for their bioconjugation. In two of the methods, constructs were prepared where the peptide (F, function) is attached to a negatively charged hydrophilic spacer (S) linked to a dioleoylphosphatidyl ethanolamine residue (L, lipid) to create a function-spacer-lipid construct (FSL). These FSLs were easily and controllably incorporated into erythrocytes for serologic testing or in a lipid bilayer deposited on a polystyrene microplate for use in an enzyme immunoassays (EIA). The third method, also an EIA, used polyacrylamide conjugated peptides (peptide-PAA) prepared by controlled condensation of the cysteine residue of the peptide with the maleimide-derived PAA polymer which were immobilized on polystyrene microplates by physisorption of the polymer. In this work, we describe the synthesis of the PAA and FSL peptide bioconjugates, design of test systems, and comparison of the bioassays results, and discuss potential reasons for higher performance of the FSL conjugates, particularly in the erythrocyte-based serologic assay.


Assuntos
Anticorpos Antivirais/análise , Desenho de Fármacos , Peptídeos/química , Peptídeos/imunologia , SARS-CoV-2/imunologia , Anticorpos Antivirais/imunologia , Glicoproteína da Espícula de Coronavírus/imunologia
10.
Biochim Biophys Acta Biomembr ; 1863(9): 183645, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34019901

RESUMO

Modification of the cell surface with synthetic glycolipids opens up a wide range of possibilities for studying the function of glycolipids. Synthetic glycolipids called Function-Spacer-Lipids (FSL; where F is a glycan or label, S is a spacer, and L is dioleoylphosphatidyl ethanolamine) easily and controllably modify the membrane of a living cells. This current study investigates the dynamics and mechanism of the FSL insertion and release/loss. FSL insert into the cell membrane (~1 million molecules per cell) within tens of minutes, almost regardless of the nature of the cells (including the thickness of their glycocalyx) and the size of the FSL glycan. FSLs do not accumulate uniformly, but instead form patches >300 nm in size either entrapped in the glycocalyx, or integrated in the plane of the plasma membrane, but always outside the cell rafts. The natural release (loss) of FSL from the modified cell was two orders of magnitude slower than attachment/insertion and occurred mainly in the form of released microvesicles with a size of 140 ± 5 nm. The accumulation of FSL as patches in the cell membrane is similar to the coalescence of natural glycosphingolipids and supports (along with their long residence time in the membrane) the use of FSL as probes for the study of glycosphingolipid-protein interactions.


Assuntos
Membrana Celular/química , Glicolipídeos/química , Células Cultivadas , Glicolipídeos/síntese química , Humanos , Estrutura Molecular
11.
Transfusion ; 61(4): 1171-1180, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33590501

RESUMO

BACKGROUND: The Coronavirus disease 2019 (COVID-19) pandemic is having a major global impact, and the resultant response in the development of new diagnostics is unprecedented. The detection of antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has a role in managing the pandemic. We evaluated the feasibility of using SARS-CoV-2 peptide Kode Technology-modified red cells (C19-kodecytes) to develop an assay compatible with existing routine serologic platforms. STUDY DESIGN AND METHODS: A panel of eight unique red cells modified using Kode Technology function-spacer-lipid constructs and bearing short SARS-CoV-2 peptides was developed (C19-kodecyte assay). Kodecytes were tested against undiluted expected antibody-negative and -positive plasma samples in manual tube and three column agglutination technology (CAT) platforms. Parallel analysis with the same peptides in solid phase by enzyme immunoassays was performed. Evaluation samples included >120 expected negative blood donor samples and >140 COVID-19 convalescent plasma samples, with independent serologic analysis from two centers. RESULTS: Specificity (negative reaction rate against expected negative samples) in three different CAT platforms against novel C19-kodecytes was >91%, which correlated with published literature. Sensitivity (positive reaction rate against expected positive convalescent, PCR-confirmed samples) ranged from 82% to 97% compared to 77% with the Abbott Architect SARS-CoV-2 IgG assay. Manual tube serology was less sensitive than CAT. Enzyme immunoassay results with some Kode Technology constructs also had high sensitivity. CONCLUSIONS: C19-kodecytes are viable for use as serologic reagent red cells for the detection of SARS-CoV-2 antibody with routine blood antibody screening equipment.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19 , COVID-19 , Eritrócitos/metabolismo , SARS-CoV-2/metabolismo , COVID-19/sangue , COVID-19/diagnóstico , Humanos
12.
Transfusion ; 58(12): 3036-3037, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30520091
13.
Carbohydr Res ; 435: 83-96, 2016 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-27721143

RESUMO

Seven lipophilic constructs containing Lewis (Lea, Leb, Ley) or chimeric Lewis/ABH (ALeb, BLeb, ALey, BLey) glycans were obtained starting from corresponding oligosaccharides in form of 3-aminopropyl glycosides. ALeb and BLeb pentasaccharides were synthesized via [3 + 1] blockwise approach. The constructs (neoglycolipids, or FSLs) were inserted in erythrocyte membrane, and obtained "kodecytes" were used to map the immunochemical specificity of historical and contemporary monoclonal and polyclonal blood group system Lewis reagents.


Assuntos
Antígenos do Grupo Sanguíneo de Lewis/química , Polissacarídeos/síntese química , Polissacarídeos/imunologia , Anticorpos Monoclonais/metabolismo , Membrana Eritrocítica/imunologia , Humanos , Antígenos do Grupo Sanguíneo de Lewis/imunologia , Estrutura Molecular , Polissacarídeos/química
14.
Virol Sin ; 29(4): 199-210, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25160755

RESUMO

Direct labeling of virus particles is a powerful tool for the visualization of virus-cell interaction events. However, this technique involves the chemical modification of viral proteins that affects viral biological properties. Here we describe an alternative approach of influenza virus labeling that utilizes Function-Spacer-Lipid (FSL) constructs that can be gently inserted into the virus membrane. We assessed whether labeling with fluorescent (fluo-Ad-DOPE) or biotin-labeled (biot-CMG2-DOPE) probes has any deleterious effect on influenza virus hemagglutinin (HA) receptor specificity, neuraminidase (NA) activity, or replicative ability in vitro. Our data clearly show that neither construct significantly affected influenza virus infectivity or viral affinity to sialyl receptors. Neither construct influenced the NA activities of the influenza viruses tested, except the A/Puerto Rico/8/34 (H1N1) strain. Our data indicate that lipid labeling provides a powerful tool to analyze influenza virus infection in vitro.


Assuntos
Vírus da Influenza A/química , Influenza Humana/virologia , Lipídeos/química , Coloração e Rotulagem/métodos , Biotina/química , Corantes Fluorescentes/química , Glicoproteínas de Hemaglutininação de Vírus da Influenza/metabolismo , Humanos , Vírus da Influenza A/metabolismo , Influenza Humana/metabolismo , Metabolismo dos Lipídeos , Neuraminidase/metabolismo , Receptores Virais/metabolismo
15.
J Virol ; 87(7): 3752-9, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23325695

RESUMO

We are developing oncolytic vesicular stomatitis viruses (VSVs) for systemic treatment of multiple myeloma, an incurable malignancy of antibody-secreting plasma cells that are specifically localized in the bone marrow. One of the presumed advantages for using VSV as an oncolytic virus is that human infections are rare and preexisting anti-VSV immunity is typically lacking in cancer patients, which is very important for clinical success. However, our studies show that nonimmune human and mouse serum can neutralize clinical-grade VSV, reducing the titer by up to 4 log units in 60 min. In addition, we show that neutralizing anti-VSV antibodies negate the antitumor efficacy of VSV, a concern for repeat VSV administration. We have investigated the potential use of covalent modification of VSV with polyethylene glycol (PEG) or a function-spacer-lipid (FSL)-PEG construct to inhibit serum neutralization and to limit hepatosplenic sequestration of systemically delivered VSV. We report that in mice passively immunized with neutralizing anti-VSV antibodies, PEGylation of VSV improved the persistence of VSV in the blood circulation, maintaining a more than 1-log-unit increase in VSV genome copies for up to 1 h compared to the genome copy numbers for the non-PEGylated virus, which was mostly cleared within 10 min after intravenous injection. We are currently investigating if this increase in PEGylated VSV circulating half-life can translate to increased virus delivery and better efficacy in mouse models of multiple myeloma.


Assuntos
Mieloma Múltiplo/terapia , Terapia Viral Oncolítica/métodos , Polietilenoglicóis/farmacologia , Vírus da Estomatite Vesicular Indiana/metabolismo , Viremia/sangue , Animais , Chlorocebus aethiops , Cromatografia , Primers do DNA/genética , Descoberta de Drogas/métodos , Proteínas de Fluorescência Verde , Humanos , Interferon beta , Estimativa de Kaplan-Meier , Camundongos , Mieloma Múltiplo/imunologia , Testes de Neutralização , Reação em Cadeia da Polimerase em Tempo Real , Células Vero , Vírus da Estomatite Vesicular Indiana/imunologia
16.
Blood ; 121(8): 1459-68, 2013 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-23255552

RESUMO

In analogy with histo-blood group A antigen, Forssman (Fs) antigen terminates with α3-N-acetylgalactosamine and can be used by pathogens as a host receptor in many mammals. However, primates including humans lack Fs synthase activity and have naturally occurring Fs antibodies in plasma. We investigated individuals with the enigmatic ABO subgroup A(pae) and found them to be homozygous for common O alleles. Their erythrocytes had no A antigens but instead expressed Fs glycolipids. The unexpected Fs antigen was confirmed in structural, serologic, and flow-cytometric studies. The Fs synthase gene, GBGT1, in A(pae) individuals encoded an arginine to glutamine change at residue 296. Gln296 is present in lower mammals, whereas Arg296 was found in 6 other primates, > 250 blood donors and A(pae) family relatives without the A(pae) phenotype. Transfection experiments and molecular modeling showed that Agr296Gln reactivates the human Fs synthase. Uropathogenic E coli containing prsG-adhesin-encoding plasmids agglutinated A(pae) but not group O cells, suggesting biologic implications. Predictive tests for intravascular hemolysis with crossmatch-incompatible sera indicated complement-mediated destruction of Fs-positive erythrocytes. Taken together, we provide the first conclusive description of Fs expression in normal human hematopoietic tissue and the basis of a new histo-blood group system in man, FORS.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas/métodos , Eritrócitos/fisiologia , Antígeno de Forssman/genética , Antígeno de Forssman/metabolismo , N-Acetilgalactosaminiltransferases/genética , N-Acetilgalactosaminiltransferases/metabolismo , Sistema ABO de Grupos Sanguíneos/genética , Sequência de Carboidratos , Cromatografia em Camada Fina , Escherichia coli/enzimologia , Genótipo , Testes de Hemaglutinação , Humanos , Modelos Químicos , Dados de Sequência Molecular , Mutagênese Sítio-Dirigida , N-Acetilgalactosaminiltransferases/química , Fenótipo , Polimorfismo Genético/fisiologia , Estrutura Terciária de Proteína
17.
J Vis Exp ; (54)2011 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-21847082

RESUMO

The ability to modify/visualize biological surfaces, and then study the modified cell/virion in a range of in vitro and in vivo environments is essential to gaining further insight into the function of specific molecules or the entire entity. Studies of biological surface modification are generally limited to genetic engineering of the organism or the covalent attachment of chemical moieties to the cell surface(1,2). However these traditional techniques expose the cell to chemical reactants, or they require significant manipulation to achieve the desired outcome, making them cumbersome, and they may also inadvertently affect the viability/functionality of the modified cell. A simple method to harmlessly modify the surface of cells is required. Recently a new technology, KODE Technology has introduced a range of novel constructs consisting of three components: a functional head group (F), a spacer (S) and a lipid tail (L) and are known as Function-Spacer-Lipid or FSL constructs3. The spacer (S) is selected to provide a construct that is dispersible in water, yet will spontaneously and stably incorporate into a membrane. FSL construct functional moieties (F) so far include a range of saccharides including blood group-related determinants, sialic acids, hyaluronan polysaccharides, fluorophores, biotin, radiolabels, and a range of peptides(3-12). FSL constructs have been used in modifying embryos, spermatozoa, zebrafish, epithelial/endometrial cells, red blood cells, and virions to create quality controls systems and diagnostic panels, to modify cell adhesion/ interaction/ separation/ immobilization, and for in vitro and in vivo imaging of cells/virions(3-12). The process of modifying cells/virions is generic and extremely simple. The most common procedure is incubation of cells (in lipid free media) with a solution for FSL constructs for 1-2 hours at 37°C(4-10). During the incubation the FSL constructs spontaneously incorporate into the membrane, and the process is complete. Washing is optional. Cells modified by FSL constructs are known as kodecytes(6-9), while virions are kodevirions(10). FSL constructs as direct infusions and kodecytes/kodevirions have been used in experimental animal models(7,8,10). All kodecytes/kodevirions appear to retain their normal vitality and functionality while gaining the new function of the F moiety(7,8,10,11). The combination of dispersibility in biocompatible media, spontaneous incorporation into cell membranes, and apparent low toxicity, makes FSL constructs valuable research tools for the study of cells and virions.


Assuntos
Biomarcadores/química , Membrana Celular/virologia , Reagentes de Ligações Cruzadas/química , Lipídeos/química , Vírion/química , Animais , Fluoresceína/química , Humanos , Camundongos , Peixe-Zebra
18.
J Virol Methods ; 176(1-2): 78-84, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21703308

RESUMO

Tools that can aid in vitro and in vivo imaging and also noninvasively determine half-life and biodistribution are required to advance clinical developments. A Function-Spacer-Lipid construct (FSL) incorporating fluorescein (FSL-FLRO4) was used to label vesicular stomatitis virus (VSV), measles virus MV-NIS (MV) and influenza virus (H1N1). The ability of FSL constructs to label these virions was established directly by FACScan of FSL-FLRO4 labeled VSV and MV, and indirectly following labeled H1N1 and MV binding to a cells. FSL-FLRO4 labeling of H1N1 was shown to maintain higher infectivity of the virus when compared with direct fluorescein virus labeling. A novel tyrosine (125)I radioiodinated FSL construct was synthesized (FSL-(125)I) from FSL-tyrosine. This was used to label VSV (VSV-FSL-(125)I), which was infused into the peritoneal cavity of laboratory mice. Bioscanning showed VSV-FSL-(125)I to localize in the liver, spleen and bloodstream in contrast to the free labels FSL-(125)I or (125)I, which localized predominantly in the liver and thyroid respectively. This is a proof-of-principle novel and rapid method for modifying virions and demonstrates the potential of FSL constructs to improve in vivo imaging of virions and noninvasively observe in vivo biodistribution.


Assuntos
Citometria de Fluxo/métodos , Fluoresceína/química , Radioisótopos do Iodo/química , Lipídeos/química , Coloração e Rotulagem/métodos , Vírion/química , Animais , Biomarcadores/química , Linhagem Celular , Chlorocebus aethiops , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Vírus da Influenza A Subtipo H1N1/química , Vírus da Influenza A Subtipo H1N1/patogenicidade , Vírus do Sarampo/química , Camundongos , Camundongos Endogâmicos C57BL , Distribuição Tecidual , Células Vero , Vírus da Estomatite Vesicular Indiana/química , Vírus da Estomatite Vesicular Indiana/patogenicidade
19.
Glycobiology ; 21(2): 162-74, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20926599

RESUMO

Glycolipids from the red cells of a rare blood group A subgroup individual, expressing the blood group A(3) phenotype with the classical mixed-field agglutination phenomenon, A(2(539G>A))/O(1) genotype, and an unusual blood group A glycolipid profile, were submitted to a comprehensive biochemical and structural analysis. To determine the nature of blood group A glycolipids in this A(3) phenotype, structural determination was carried out with complementary techniques including proton nuclear magnetic resonance (1D and 2D), mass spectrometry (MS) (nano-electrospray ionization/quadrupole time-of-flight and tandem mass spectrometry) and thin layer chromatography with immunostaining detection. As expected, total blood group A structures were of low abundance, but contrary to expectations extended-A type 2 and A type 3 glycolipids were more dominant than A hexaglycosylceramides based on type 2 chain (A-6-2 glycolipids), which normally is the major A glycolipid. Several para-Forssman (GalNAcß3GbO(4)) structures, including extended forms, were identified but surmised not to contribute to the classic mixed-field agglutination of the A(3) phenotype. It is proposed that the low level of A antigen combined with an absence of extended branched glycolipids may be the factor determining the mixed-field agglutination phenomenon in this individual.


Assuntos
Sistema ABO de Grupos Sanguíneos/sangue , Sistema ABO de Grupos Sanguíneos/genética , Glicolipídeos , Testes de Aglutinação , Sequência de Carboidratos/genética , Cromatografia em Camada Fina , Eritrócitos/química , Eritrócitos/imunologia , Estudos de Associação Genética , Genótipo , Glicolipídeos/análise , Glicolipídeos/química , Glicolipídeos/imunologia , Humanos , Espectroscopia de Ressonância Magnética , Espectrometria de Massas , Dados de Sequência Molecular , Fenótipo , Sorologia
20.
Curr Opin Hematol ; 16(6): 467-72, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19680123

RESUMO

PURPOSE OF REVIEW: This review describes the current state-of-the-art with respect to the modification of red blood cells for creating quality controls for use in immunohaematology. RECENT FINDINGS: The author has identified five technologies able to create modified red blood cells potentially suitable for use in quality control. Two of the technologies use enzymes, glycosidases or glycosyltransferases, to modify red blood cells and create ABO quality control cells. A third technology uses polyethylene glycol to reduce antigen expression by masking epitopes, whereas a fourth technology is speculative and involves the in-vitro generation of genetically modified erythroid cells. None of these four technologies are in routine use to make commercially available quality controls. A fifth commercially available technology creates quality controls by adding synthetic blood group A and B antigens (FSLs) to group O red blood cells, creating what are referred to as 'kodecytes'. This technology is also being used to add blood group peptides onto red cells for use in the future in a range of diagnostic applications. SUMMARY: Transducing cell-derived erythroid populations with blood group encoding or silencing vectors, and the use of FSLs to create kodecytes, are two technologies with the potential to provide quality controls for laboratory use.


Assuntos
Eritrócitos , Controle de Qualidade , Citometria de Fluxo , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA