Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Clin Kidney J ; 14(3): 1004-1013, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34141409

RESUMO

BACKGROUND: Metabolic acidosis is a common problem in haemodialysis patients, but acidosis overcorrection has been associated with higher mortality. There is no clear definition of the optimal serum bicarbonate target or dialysate bicarbonate. This study analysed the impact of reducing dialysate bicarbonate from 35 to 32 mEq/L on plasma bicarbonate levels in a cohort of patients treated with online haemodiafiltration (OL-HDF). METHODS: We performed a prospective cohort study with patients in a stable chronic OL-HDF programme for at least 12 months in the Hospital Clinic of Barcelona. We analysed pre- and post-dialysis total carbon dioxide(TCO2) before and after dialysate bicarbonate reduction from 35 to 32 mEq/L, as well as the number of patients with a pre- and post-dialysis TCO2 within 19-25 and ≤29 mEq/L, respectively, after the bicarbonate modification. Changes in serum sodium, potassium, calcium, phosphorous and parathyroid hormone (PTH) were also assessed. RESULTS: We included 84 patients with a 6-month follow-up. At 6 months, pre- and post-dialysis TCO2 significantly decreased (26.78 ± 1.26 at baseline to 23.69 ± 1.92 mEq/L and 31.91 ± 0.91 to 27.58 ± 1.36 mEq/L, respectively). The number of patients with a pre-dialysis TCO2 >25 mEq/L was significantly reduced from 80 (90.5%) to 17 (20.2%) and for post-dialysis TCO2 >29 mEq/L this number was reduced from 83 (98.8%) to 9 (10.7%). PTH significantly decreased from 226.09 (range 172-296) to 182.50 (125-239) pg/mL at 6 months (P < 0.05) and post-dialysis potassium decreased from 3.16 ± 0.30 to 2.95 ± 0.48 mEq/L at 6 months (P < 0.05). Sodium, pre-dialysis potassium, calcium and phosphorous did not change significantly. CONCLUSIONS: Reducing dialysate bicarbonate concentration by 3 mEq/L significantly and safely decreased pre- and post-dialysis TCO2, avoiding acidosis overcorrection and improving secondary hyperparathyroidism control. An individualized bicarbonate prescription (a key factor in the adequate control of acidosis) according to pre-dialysis TCO2 is suggested based on these results.

2.
Artif Organs ; 45(10): 1195-1201, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33978975

RESUMO

The Clearum dialyzer, built by Medtronic, became commercially available in several European countries in 2020, but there are still no reports of in vivo data. The aim of this study was to evaluate the efficacy and risk of hypoalbuminemia of this dialyzer compared with previously evaluated hemodialysis (HD), expanded hemodialysis (HDx), and postdilution hemodiafiltration (HDF) treatments. A prospective study was carried out in 15 patients. Each patient underwent seven dialysis sessions: FX80 Cordiax in HD, Clearum HS17 in HD, Phylther 17-SD in HDx, Theranova 400 in HDx, Phylther 17-G in postdilution HDF, Clearum HS17 in postdilution HDF, and FX80 Cordiax in postdilution HDF. The reduction ratios of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. Dialysate albumin loss was also measured. Comparison of dialysis techniques revealed no differences between small molecules, but HDx and HDF were significantly higher than HD with medium and large molecular weights. The Clearum dialyzer in HDF obtained similar results to FX80 Cordiax in HDF, was slightly superior to Phylther 17-G in HDF, and was statistically superior to both dialyzers in HDx. Albumin losses with the Clearum dialyzer were among the lowest, both in HD and HDF treatments. The highest global removal score (GRS) values were obtained with the helixone and Clearum dialyzers in HDF, with similar results both in HD and HDF. In addition, the GRS values with HDx treatments were statistically significantly higher than those with HD. The new Clearum dialyzer has excellent behavior and tolerance in HD and HDF. Its adequate permeability has been proven with its maximal performance in HDF, which could represent an upgrade versus its predecessor polyphenylene dialyzers.


Assuntos
Hemodiafiltração/instrumentação , Falência Renal Crônica/terapia , Diálise Renal/instrumentação , Idoso , Idoso de 80 Anos ou mais , alfa-Globulinas/análise , Creatinina/sangue , Feminino , Hemodiafiltração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Mioglobina/sangue , Orosomucoide/análise , Segurança do Paciente , Prolactina/sangue , Estudos Prospectivos , Diálise Renal/métodos , Resultado do Tratamento , Ureia/sangue , Microglobulina beta-2/sangue
3.
Artif Organs ; 45(9): E317-E323, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33908062

RESUMO

Toray has created a new generation of dialyzers, the polysulphone (TS) UL series, and polymethylmethacrylate (PMMA) NF-U series, which offer enhanced efficacy over the previous TS-S series and NF-H series. The aim of this study was to evaluate the safety and efficacy of these dialyzer series versus contrasted expanded hemodialysis (HDx) and postdilution hemodiafiltration (HDF). We conducted a prospective study in 12 patients. Each patient underwent six dialysis sessions: FX80 Cordiax in HD, Toraysulfone TS-1.8 UL in HD, Theranova 400 in HDx, polymethylmethacrylate (PMMA) NF-2.1 U in HDF, Toraysulfone TS-2.1 UL in HDF, and FX80 Cordiax in HDF. The removal ratios (RRs) of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. Dialysate albumin loss was also measured. The RRs for ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, and α1 -acid glycoprotein were higher with the TS-2.1 UL and FX80 Cordiax dialyzers in HDF than those obtained with HD treatments and NF-2.1 U in HDF. The ß2 -microglobulin, myoglobin, and prolactin RRs were also higher with HDx than those obtained with HD treatments. The myoglobin and prolactin RRs were higher with TS-1.8 UL in HD than those obtained with helixone dialyzers in HD. Dialysate albumin loss was less than 3 g in all situations except in TS-2.1 UL in HDF. The highest global removal score values were obtained with the TS-2.1 UL and helixone dialyzers in HDF. Significant differences were found between all study situations. In conclusion, the new generation dialyzers, Toraysulfone TS Series UL and PMMA NF-U series, show excellent behaviour and tolerance in HD and HDF, representing an upgrade versus their predecessor series. The higher permeability of the TS UL series has been proven with higher efficiency in HD and maximum performance in HDF. The new PMMA NF-U series allows the use of HDF with good efficiency and complete safety.


Assuntos
Hemodiafiltração/instrumentação , Nefropatias/terapia , Membranas Artificiais , Polímeros/química , Polimetil Metacrilato/química , Sulfonas/química , Idoso , Biomarcadores/sangue , Feminino , Humanos , Nefropatias/sangue , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
5.
Int J STD AIDS ; 29(10): 1039-1042, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29629650

RESUMO

Fusarium infections are very rare in HIV-infected patients, even in patients in advanced stages of immunosuppression. All the reported cases in the literature are of disseminated infection, and with poor outcomes despite prompt and appropriate treatment. To the best of our knowledge, this is the first report of a localized infection with Fusarium keratoplasticum in an HIV-positive patient, successfully treated with a combination of antifungal therapy and surgical removal of the focus.


Assuntos
Antifúngicos/administração & dosagem , Antifúngicos/uso terapêutico , Cumarínicos/isolamento & purificação , Fusariose/diagnóstico , Infecções por HIV/complicações , Linfonodos/patologia , Administração Oral , Adulto , Cumarínicos/classificação , Fusariose/complicações , Fusariose/tratamento farmacológico , Infecções por HIV/diagnóstico , Humanos , Linfonodos/cirurgia , Infecções Oportunistas , Reação em Cadeia da Polimerase , Pessoas Transgênero , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA