Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38752961

RESUMO

BACKGROUND: The extravascular (EV) implantable cardioverter-defibrillator (ICD) includes features to address sensing and arrhythmia detection challenges presented by its substernal lead location. OBJECTIVES: In this study, the authors sought to evaluate sensing and detection performance in 299 patients discharged with an EV-ICD in the global pivotal study. METHODS: We reviewed and adjudicated all induced ventricular fibrillation (VF) episodes and spontaneous device-stored episodes that satisfied rate and duration criteria in a programmed ventricular tachycardia (VT)/VF therapy zone. RESULTS: At implantation, all EV-ICDs detected induced VF at the programmed sensitivity; 95.9% detected VF with a 3× safety margin. In follow-up, EV-ICDs detected all 59 VT/VF episodes that sustained until therapy. Of 1,034 non-VT/VF episodes, oversensing caused 87.9% and supraventricular tachycardia caused 12.1%. Therapy was withheld in 80.9%, aborted in 10.6%, and delivered in 8.5%. The most common causes of oversensing were myopotentials (61.2%) and P-wave oversensing (PWOS) (19.9%). Inappropriate shocks occurred in only 3.2% of myopotential episodes, but in 21.8% of PWOS episodes. Myopotential oversensing was more common with Ring-Can sensing (P < 0.0001) and correlated with low R-wave amplitude (P < 0.0001). PWOS occurred almost exclusively with Ring1-Ring2 sensing (P = 0.0001) and began with transient decrease in R-wave or increase in P-wave amplitude (P < 0.0001). In software emulation, a new PWOS discriminator significantly reduced total inappropriate detections. CONCLUSIONS: In a global population, EV-ICD detected induced and spontaneous VT/VF accurately. Although discriminators withheld detection from most non-VT/VF episodes, inappropriate shocks were common. The most common cause was PWOS, which may be reduced by optimizing sensing at implantation and incorporation of the PWOS discriminator, which is now in the current device. (Extravascular ICD Pivotal Study [EV ICD]; NCT04060680).

2.
Heart Rhythm ; 15(3): 442-448, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29146275

RESUMO

BACKGROUND: In the chronic atrioventricular block (CAVB) dog model, beat-to-beat variation of repolarization in the left ventricle (LV) quantified as short-term variability of the left monophasic action potential duration (STVLVMAPD) increases abruptly upon challenge with a proarrhythmic drug. This increase occurs before the first ectopic beat (EB), specifically in subjects who demonstrate subsequent repetitive torsades de pointes arrhythmias (TdP). OBJECTIVE: The purpose of this study was to demonstrate that STV is feasible to monitor arrhythmic risk through use of the intracardiac electrogram (EGM) derived from the right ventricular (RV) lead from pacemakers or implantable cardioverter-defibrillators. METHODS: In 30 anaesthetized, inducible (≥3 TdP) CAVB dogs, STV between LV and RV monophasic action potential duration (STVLVMAPD and STVRVMAPD) was compared. In prospectively enrolled CAVB dogs, STV of the activation-recovery interval (ARI) derived from the RV EGM (STVRVARI) was measured before and after a challenge with dofetilide under anesthesia (2a; n = 10) and cisapride under awake conditions (2b; n = 8). RESULTS: Both STVLVMAPD and STVRVMAPD increased before the first EB (1.29 ± 0.58 ms to 3.05 ± 1.70 ms and 1.11 ± 0.53 ms to 2.18 ± 1.43 ms, respectively; P = 0.001). STVRVARI increased from 2.82 ± 0.33 ms to 3.77 ± 0.69 ms (P = .001). Inducible subjects (4/8) showed an increase in STVRVARI from 2.65 ± 0.55 ms to 3.45 ± 0.33 ms (in the first hour; P = .02) and 4.20 ± 1.33 ms (before the first EB; P = .04). CONCLUSION: Behavior of STV from the RV and LV is comparable. STVRVARI increases significantly before the occurrence of an arrhythmia in awake and anaesthetized conditions. This finding can be integrated into devices to monitor arrhythmic risk.


Assuntos
Anestesia , Bloqueio Atrioventricular/fisiopatologia , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas/métodos , Frequência Cardíaca/fisiologia , Ventrículos do Coração/fisiopatologia , Monitorização Fisiológica/métodos , Animais , Bloqueio Atrioventricular/terapia , Doença Crônica , Modelos Animais de Doenças , Cães , Feminino , Seguimentos , Masculino , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA