Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Emerg Radiol ; 29(6): 979-985, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35922682

RESUMO

BACKGROUND: Sepsis is a life-threatening condition that requires immediate focus identification and control. However, international sepsis guidelines do not provide information on imaging choice. PURPOSE: To identify predictors of CT findings and patient outcomes in a population of septic patients from a medical ICU. MATERIAL AND METHODS: A full-text search in the radiological information system (RIS) retrieved 227 body CT examinations conducted to identify infectious sources in 2018. CT reports were categorized according to identified foci and their diagnostic certainty. Diagnostic accuracy of CT was compared to microbiological results. Clinical and laboratory information was gathered. Statistical analysis was performed using nonparametric tests and logistic regression analysis. RESULTS: CT revealed more positive infectious foci 52.4% (n = 191/227) than microbiological tests 39.3% (n = 79/201). There were no significant differences between focus-positive CT scans with regard to positive microbiological testing (p = 0.32). Sequential organ failure assessment (SOFA) scores were slightly but nonsignificantly higher in patients with a focus-positive CT, odds ratio (OR) = 0.999 (95% CI 0.997-1.001) with p = 0.52. Among C-reactive protein (CRP), procalcitonin (PCT), and leukocytes, in focus-positive versus focus-negative CT scans, CRP showed a minor but statistically significant elevation in the group with focus-positive CT scans (OR = 1.004, 95% CI = 1.000-1.007, p = 0.04). No significant association was found for PCT (OR = 1.007, 95% CI = 0.991-1.023; p = 0.40) or leukocytes (OR = 1.003, 95% CI = 0.970-1.038; p = 0.85). In 33.5% (n = 76/227) of cases, the CT findings had at least one therapeutic consequence. In 81.6% (n = 62/76), the CT findings resulted in one consequence, in 14.5% (n = 11/76) in two consequences, and in 3.9% (n = 3/76) in three consequences. There was no significant association between focus-positive CT scans and mortality (p = 0.81). CONCLUSION: In this population of septic patients in medical intensive care, microbiological analysis complemented CT findings. Both clinical and laboratory parameters were not predictive of CT findings. While therapeutic consequences of CT findings in this study population underline the role of CT for decision making in septic patients, CT findings do not predict patient outcomes in this retrospective analysis.


Assuntos
Sepse , Humanos , Estudos Retrospectivos , Estudos de Coortes , Prognóstico , Sepse/diagnóstico por imagem , Sepse/metabolismo , Pró-Calcitonina/metabolismo , Proteína C-Reativa , Tomografia Computadorizada por Raios X , Unidades de Terapia Intensiva
2.
Int J Hyperthermia ; 39(1): 504-516, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35296213

RESUMO

OBJECTIVE: Hyperthermia as an enhancer of radio- and/or chemotherapy has been confirmed by various trials. Quite a few positive randomized trials have been carried out with capacitive hyperthermia systems (CHS), even though specific absorption rates (SAR) in deep regions are known to be inferior to the established annular-phased array techniques. Due to a lack of systematic SAR measurements for current capacitive technology, we performed phantom measurements in combination with simulation studies. MATERIALS AND METHODS: According to the current guidelines, homogeneous and inhomogeneous agarose phantoms were manufactured for the commercial CHS Celsius42. Temperature/time curves were registered, and specific absorption rate (SAR) profiles and distributions were derived using the temperature gradient method. We implemented models for electrodes and phantom setups for simulation studies using Sim4Life. RESULTS: For a standard total power of 200 W, we measured effective SAR until depths of 6-8 cm in a homogeneous phantom, which indicates fair heating conditions for tumor diseases in superficial and intermediate depths. A fat layer of 1 cm strongly weakens the SAR, but 10-20 W/kg are still achieved in intermediate to deep regions (2-10 cm). In the phantom setup with integrated bone, we measured low SAR of 5-10 W/kg in the cancellous bone. Our simulations could fairly describe the measured SAR distributions, but predict tendentially higher SAR than measured. Additional simulations suggest that we would achieve higher SAR with vital fatty tissue and bone metastases in clinical situations. CONCLUSION: Capacitive systems are suitable to heat superficial and medium-deep tumors as well as some bone metastases, and CHS application is feasible for a specific class of patients with pelvic and abdominal tumors. These findings are consistent with positive clinical studies.


Assuntos
Hipertermia Induzida , Neoplasias , Simulação por Computador , Humanos , Hipertermia , Hipertermia Induzida/métodos , Neoplasias/terapia , Imagens de Fantasmas
3.
Int J Hyperthermia ; 38(1): 663-678, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33899658

RESUMO

OBJECTIVE: To create an improved planning method for pediatric regional hyperthermia (RHT) using the SIGMA-30 applicator (SIGMA-30). MATERIALS AND METHODS: An electromagnetic model of SIGMA-30 was generated for use with the finite-difference time-domain (FDTD) method. Applying special MATLAB-based algorithms, voxel models of a pediatric patient with pelvic rhabdomyosarcoma were created from Computed-Tomography (CT) contours for use with the FDTD method and the finite-difference (FD) method capable of using either temperature-independent or temperature-dependent perfusion models for solving the Bioheat Transfer Equation (BHTE). Patient models were parametrized regarding, first, the positioning in the applicator, second, the absorbed power range and, third, different perfusion models, resulting in the so-called Parametrized Treatment Models (PTMs). A novel dedicated optimization procedure was developed based on quantitative comparison of numerical calculations against temperature and power measurements from two RHT therapies. RESULTS: Using measured data, a realistic absorbed power range in the patient model was estimated. Within this range, several FDTD and BHTE runs were performed and, applying the aforementioned optimization scheme, the best PTMs and perfusion models were identified for each therapy via a retrospective comparison with measurements in 14 temperature sensor positions: 5 in the tumor, 8 in rectum and one in bladder. CONCLUSION: A novel dedicated optimization procedure for identification of suitable patient-specific electromagnetic and thermal models, which can be used for improved patient planning, was developed and evaluated by comparison with treatment-derived measurements using SIGMA-30. The optimization procedure can be extended to other hyperthermia applicators and to other patient types, including adults.


Assuntos
Hipertermia Induzida , Neoplasias , Algoritmos , Criança , Humanos , Hipertermia , Neoplasias/terapia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA