Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Int J Obstet Anesth ; 45: 83-89, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33298344

RESUMO

BACKGROUND: Epidural analgesia provides sufficient analgesia during labor but can cause hypotension despite various prophylactic measures. We studied its effects on pre-placental, fetoplacental, and fetal hemodynamics using Doppler ultrasound. The primary endpoint was the pulsatility index of the umbilical artery at 30 min after establishing epidural analgesia. Secondary endpoints included maternal blood pressures and neonatal outcome data. METHODS: We included healthy parturients at a cervical dilation ≥2 cm, with or without a request for epidural analgesia (n=32 per group). Ultrasound studies of the uterine arteries, umbilical artery and fetal middle cerebral artery were performed before insertion of the epidural catheter, and 30, 60 and 90 min after; the same time-points were assessed in the non-epidural control group. Maternal blood pressure was measured by a continuous non-invasive arterial pressure monitor. RESULTS: Ultrasound studies detected no significant differences in pulsatility indices over time in any blood vessel. In contrast to the control group, maternal blood pressures were significantly lower for all measures after the onset of analgesia compared with baseline values (mean systolic pressure decreased from 132.7 ±â€¯15.9 mmHg to 123.1 ±â€¯14.4 mmHg at 30 min, P=0.003). The mean pH value of the umbilical arterial blood was 7.29 (±0.06) in the epidural group versus 7.31 (±0.08) in the control group (P=0.33). The median Apgar score at 5 min was 10 in both groups. CONCLUSIONS: Pre-placental, fetoplacental and fetal hemodynamics remained stable despite a statistically significant decrease in maternal blood pressure in laboring parturients receiving epidural analgesia.


Assuntos
Analgesia Epidural , Trabalho de Parto , Pressão Sanguínea , Feminino , Hemodinâmica , Humanos , Recém-Nascido , Placenta/diagnóstico por imagem , Gravidez
2.
Anaesthesist ; 68(1): 30-38, 2019 01.
Artigo em Alemão | MEDLINE | ID: mdl-30446807

RESUMO

BACKGROUND: Safety strategies in civil aviation are well-established. The authors present a possible structure for induction of anesthesia, which includes elements of the so-called cockpit strategy. The objective is to reduce anesthesia-related mortality caused by the unexpected difficult airway through early detection and solution of cannot intubate cannot oxygenate (CICO) situations. METHODS: After approval by the responsible ethics committee, a prospective pilot study was conducted to analyze the process quality of uncomplicated induction of anesthesia on a simulator using audiovisual recording. An evaluation list with 44 items was created, which met the following requirements: items were dichotomous, accessible to an audiovisual evaluation and according to current scientific consensus should be considered during induction of anesthesia. Standard induction of anesthesia was supplemented by several crew resource management elements (cockpit strategy). Two canned decisions (CD, CD 1: end tidal CO2, etCO2 < 10 mm Hg, CD 2: SpO2 < 80%) signaled the emergency of an unexpected difficult airway and CICO with emergency coniotomy. This concept was repetitively trained and transferred to the daily routine. After 6 months the process quality was re-evaluated in simulated scenarios. In order to review whether the effect of the cockpit strategy with the CD can contribute to solving the CICO situation, all emergency coniotomies carried out in this clinic between 2010 and 2016 were retrospectively analyzed. RESULTS: The cockpit strategy significantly improved the process quality during the simulated induction of anesthesia (78% vs. 36% items fulfilled), while the duration of induction was reduced by 36%. In the subsequent 6­year study period, 7 CICO situations with emergency coniotomy occurred. All teams performed in accordance with the algorithm and with respect to the CDs. No patient suffered from hypoxia or any other damage. CONCLUSION: The transfer and implementation of a cockpit strategy in anesthesiology for improvement of patient safety is possible. The acceptance of the aviation safety strategy in medicine is a necessary prerequisite. A profound training in technical and non-technical skills and regular team training to solve CICO situations must be an integral part of advanced training in anesthesiology.


Assuntos
Manuseio das Vias Aéreas/métodos , Intubação Intratraqueal/métodos , Anestesiologia , Humanos , Simulação de Paciente , Estudos Prospectivos , Estudos Retrospectivos
3.
Anaesthesia ; 71(8): 915-20, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27277674

RESUMO

Although sevoflurane is commonly used in anaesthesia, a threshold value for maximum exposure to personnel does not exist and although anaesthetists are aware of the problem, surgeons rarely focus on it. We used a photo-acoustic infrared device to measure the exposure of surgeons to sevoflurane during paediatric adenoidectomies. Sixty children were randomly allocated to laryngeal mask, cuffed tracheal tube or uncuffed tracheal tube. The average mean (maximum) sevoflurane concentrations within the surgeons' operating area were 1.05 (10.05) ppm in the laryngeal mask group, 0.33 (1.44) ppm in the cuffed tracheal tube group and 1.79 (18.02) ppm in the uncuffed tracheal tube group, (p < 0.001), laryngeal mask and cuffed tracheal tube groups vs. uncuffed tube group. The presence of sevoflurane was noticed by surgeons in 20% of cases but there were no differences between the groups (p = 0.193). Surgical and anaesthetic complications were similar in all three groups. We conclude that sevoflurane can be safely used during adenoidectomies with all three airway devices, but in order to minimise sevoflurane peak concentrations, cuffed tracheal tubes are preferred.


Assuntos
Adenoidectomia/instrumentação , Anestésicos Inalatórios/administração & dosagem , Intubação Intratraqueal/instrumentação , Éteres Metílicos/administração & dosagem , Exposição Ocupacional , Cirurgiões , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Máscaras Laríngeas , Masculino , Pessoa de Meia-Idade , Sevoflurano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA