Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Pain Res Manag ; 2023: 2136562, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37200968

RESUMO

Objectives: Failed back surgery syndrome (FBSS) refers to a condition where symptoms such as low back pain, leg pain, and numbness persist or recur after lumbar surgery; it has been reported to occur in 10%-40% of patients who have undergone lumbar surgery. Spinal cord stimulation (SCS) has been reported useful for low back and leg pain due to FBSS. In this study, we studied the efficacy and safety of SCS for FBSS in older adults. Methods: Among FBSS patients who underwent an SCS trial between November 2017 and December 2020, those with at least 50% pain reduction during the trial phase who requested spinal cord stimulator implantation underwent implantation of a stimulator under local anesthesia. The patients were divided into two groups: patients aged <75 years (<75-year-old group) and patients aged ≥75 years (≥75-year-old group). The male/female ratio, symptom duration, operative duration, visual analog scale (VAS) scores before and after one year of surgery, responder rate (RR), complications one year after surgery, and stimulator removal rate were analyzed. Results: There were 27 cases in the <75-year-old group and 46 in the ≥75-year-old group, with no significant differences in male/female ratio, duration of pain, or operative time between the two groups. VAS scores for low back pain, leg pain, and overall pain one year after surgery were improved significantly from respective preoperative scores in both groups (P < 0.001). There were no significant differences in low back pain VAS, leg pain VAS, overall pain VAS, RR, complications one year after surgery, or stimulator removal rate between the two groups. Conclusion: SCS reduced pain effectively in both <75-year-old and ≥75-year-old groups with no differences in complications. Therefore, spinal cord stimulator implantation was considered a viable option for FBSS treatment in older adults because it can be performed under local anesthesia and is associated with a low incidence of complications.


Assuntos
Síndrome Pós-Laminectomia , Dor Lombar , Estimulação da Medula Espinal , Idoso , Humanos , Masculino , Feminino , Estudos Retrospectivos , Síndrome Pós-Laminectomia/terapia , Síndrome Pós-Laminectomia/diagnóstico , Dor Lombar/cirurgia , Resultado do Tratamento , Medula Espinal
2.
J Neurosurg Spine ; 36(2): 185-192, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34598157

RESUMO

OBJECTIVE: Perineural cysts, also called Tarlov cysts, are dilatations of the nerve root sleeves commonly found in the sacrum. The majority of the cysts are asymptomatic and found incidentally on routine spine imaging. Symptomatic sacral perineural cysts (SPCs) that induce intractable low-back pain, radicular symptoms, and bladder/bowel dysfunction require surgery. However, the surgical strategy for symptomatic SPCs remains controversial. The authors hypothesized that the symptoms were caused by an irritation of the adjacent nerve roots caused by SPCs, and developed a wrapping surgery to treat these cysts. METHODS: Seven patients with severe unilateral medial thigh pain and ipsilateral SPCs were included. Preoperative MRI showed that the cysts were severely compressing the adjacent nerve roots in all patients. After a partial laminectomy of the sacrum, the SPCs were punctured and CSF was aspirated to reduce their size, followed by dissection of the adjacent nerve roots from the SPCs. The SPCs were then wrapped with a Gore-Tex membrane to avoid reexpansion. RESULTS: All 7 patients experienced substantial relief of their symptoms. The average numeric rating scale pain score was reduced from an average preoperative value of 7.9 to 0.6 postoperatively. Postoperative MRI showed that all cysts were reduced in size and the adjacent nerve roots were decompressed. Regrowth of the treated cysts or recurrence of the symptoms did not occur during the entire follow-up period, which ranged from 39 to 90 months. No complications were noted. CONCLUSIONS: The authors' new wrapping technique was effective in relieving radicular symptoms for patients with symptomatic SPCs. The results suggested that the symptoms stemmed from compression of the adjacent nerve roots caused by the SPCs, and not from the nerve roots in the cysts.

3.
BMJ Case Rep ; 14(1)2021 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-33402370

RESUMO

A 67-year-old man presented with a 2-month history of pain in his right buttock and lower limb. MRI depicted right L5/S1 lateral recess stenosis requiring surgical treatment; however, preoperative CT showed an approximately 7 cm long, thin, rod-shaped structure in the rectum, which was ultimately determined to be an accidentally ingested toothpick. It was removed surgically 6 days after diagnosis, because right leg pain worsened rapidly. The pain disappeared thereafter, and the symptoms have not recurred since. The pain might have been localised to the right buttock and posterior thigh in the early stages because the fine tip of the toothpick was positioned to the right of the anterior ramus of the S2 spinal nerve. Although sacral plexus disorder caused by a rectal foreign body is extremely rare, physicians should be mindful to avoid misdiagnosis.


Assuntos
Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia , Plexo Lombossacral , Doenças do Sistema Nervoso Periférico/diagnóstico por imagem , Doenças do Sistema Nervoso Periférico/etiologia , Reto , Idoso , Corpos Estranhos/complicações , Humanos , Masculino , Doenças do Sistema Nervoso Periférico/cirurgia
4.
BMC Neurol ; 20(1): 402, 2020 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-33143678

RESUMO

BACKGROUND: Persistent first intersegmental artery (PFIA) is a rare anatomical variation of vertebral arteries and is an asymptomatic finding in most cases. Here we report a rare case of cervical myelopathy caused by spinal cord compression by the PFIA. CASE PRESENTATION: The patient was a 52-year-old man who complained of numbness and burning sensation around the neck and left shoulder area, partial weakness in the left deltoid muscle, right side thermal hypoalgesia, and disturbance of deep sensation since the past 1 year, and the symptoms had gradually worsened. Magnetic resonance imaging (MRI) and computed tomography (CT) showed spinal cord compression by the left PFIA at the C1/C2 level. Because conservative treatment was ineffective, microvascular decompression (MVD) of the PFIA was performed. The left PFIA was laterally transposed using polytetrafluoroethylene (PTFE) bands and anchored to the dura mater using three PTFE bands. To achieve adequate transposition, the small blood vessels bridging the spinal cord and PFIA and the dorsal root nerve had to be sacrificed. Postoperative T2-weighted MRI showed a small hyperintense region in the lateral funiculus of the spinal cord, but no new neurological deficits were identified. In the early postoperative stage, the patient's deep sensory impairment and motor dysfunction were improved. His numbness and burning sensation almost disappeared, but slight thermal hypoalgesia remained in the lower limb. CONCLUSION: MVD is an effective treatment for spinal cord compression caused by the PFIA, but further studies are necessary to help address technical difficulties and avoid complications.


Assuntos
Cirurgia de Descompressão Microvascular/métodos , Compressão da Medula Espinal/cirurgia , Doenças da Medula Espinal/etiologia , Vértebras Cervicais , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Artéria Vertebral/cirurgia
5.
Spine (Phila Pa 1976) ; 43(23): 1685-1694, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30045345

RESUMO

STUDY DESIGN: A prospective clinical study of a multistep screw insertion method using a patient-specific screw guide template system (SGTS) for the cervical and thoracic spine. OBJECTIVE: To evaluate the efficacy of SGTS for inserting screws into the cervical and thoracic spine. SUMMARY OF BACKGROUND DATA: Posterior screw fixation is a standard procedure for spinal instrumentation; however, screw insertion carries the risk of injury to neuronal and vascular structures. METHODS: Preoperative bone images of the computed tomography (CT) scans were analyzed using 3D/multiplanar imaging software, and the screw trajectories were planned. Plastic templates with screw-guiding structures were created for each lamina using 3D design and printing technology. Three types of templates were made for precise multistep guidance, and all the templates were specially designed to fit and lock onto the lamina during the procedure. In addition, plastic vertebra models were generated, and preoperative screw insertion simulation was performed. This patient-specific SGTS was used to perform the surgery, and CT scanning was used to postoperatively evaluate screw placement. RESULTS: Enrolled to verify this procedure were 103 patients with cervical, thoracic, or cervicothoracic pathologies. The SGTS were used to place 813 screws. Preoperatively, each template was found to fit exactly and to lock onto the lamina of the vertebra models. In addition, intraoperatively, the templates fit and locked onto the patient lamina, and the screws were inserted successfully. Postoperative CT scans confirmed that 801 screws (98.5%) were accurately placed without cortical violation. There were no injuries to the vessels or nerves. CONCLUSION: The multistep, patient-specific SGTS is useful for intraoperative pedicle screw (PS) navigation in the cervical and thoracic spine. This method improves the accuracy of PS insertion and reduces the operating time and radiation exposure during spinal fixation surgery. LEVEL OF EVIDENCE: 3.


Assuntos
Parafusos Ósseos , Vértebras Cervicais/cirurgia , Fusão Vertebral/métodos , Vértebras Torácicas/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
6.
Spine (Phila Pa 1976) ; 42(6): E340-E346, 2017 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-27454537

RESUMO

STUDY DESIGN: Prospective clinical trial of the screw insertion method for posterior C1-C2 fixation utilizing the patient-specific screw guide template technique. OBJECTIVE: To evaluate the efficacy of this method for insertion of C1 lateral mass screws (LMS), C2 pedicle screws (PS), and C2 laminar screws (LS). SUMMARY OF BACKGROUND DATA: Posterior C1LMS and C2PS fixation, also known as the Goel-Harms method, can achieve immediate rigid fixation and high fusion rate, but the screw insertion carries the risk of injury to neuronal and vascular structures. Dissection of venous plexus and C2 nerve root to confirm the insertion point of the C1LMS may also cause problems. We have developed an intraoperative screw guiding method using patient-specific laminar templates. METHODS: Preoperative bone images of computed tomography (CT) were analyzed using three-dimensional (3D)/multiplanar imaging software to plan the trajectories of the screws. Plastic templates with screw guiding structures were created for each lamina using 3D design and printing technology. Three types of templates were made for precise multistep guidance, and all templates were specially designed to fit and lock on the lamina during the procedure. Surgery was performed using this patient-specific screw guide template system, and placement of the screws was postoperatively evaluated using CT. RESULTS: Twelve patients with C1-C2 instability were treated with a total of 48 screws (24 C1LMS, 20 C2PS, 4 C2LS). Intraoperatively, each template was found to exactly fit and lock on the lamina and screw insertion was completed successfully without dissection of the venous plexus and C2 nerve root. Postoperative CT showed no cortical violation by the screws, and mean deviation of the screws from the planned trajectories was 0.70 ±â€Š0.42 mm. CONCLUSION: The multistep, patient-specific screw guide template system is useful for intraoperative screw navigation in posterior C1-C2 fixation. This simple and economical method can improve the accuracy of screw insertion, and reduce operation time and radiation exposure of posterior C1-C2 fixation surgery. LEVEL OF EVIDENCE: 3.


Assuntos
Articulação Atlantoaxial/cirurgia , Parafusos Ósseos , Vértebras Cervicais/cirurgia , Instabilidade Articular/cirurgia , Adulto , Idoso , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Parafusos Pediculares , Estudos Prospectivos , Fusão Vertebral/métodos
7.
J Neurosurg Spine ; 21(2): 231-8, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24785974

RESUMO

OBJECT: Accurate insertion of C-2 cervical screws is imperative; however, the procedures for C-2 screw insertion are technically demanding and challenging, especially in cases of C-2 vertebral abnormality. The purpose of this study is to report the effectiveness of the tailor-made screw guide template (SGT) system for placement of C-2 screws, including in cases with abnormalities. METHODS: Twenty-three patients who underwent posterior spinal fusion surgery with C-2 cervical screw insertion using the SGT system were included. The preoperative bone image on CT was analyzed using multiplanar imaging software. The trajectory and depth of the screws were designed based on these images, and transparent templates with screw guiding cylinders were created for each lamina. During the operation, after templates were engaged directly to the laminae, drilling, tapping, and screwing were performed through the templates. The authors placed 26 pedicle screws, 12 pars screws, 6 laminar screws, and 4 C1-2 transarticular screws using the SGT system. To assess the accuracy of the screw track under this system, the deviation of the screw axis from the preplanned trajectory was evaluated on postoperative CT and was classified as follows: Class 1 (accurate), a screw axis deviation less than 2 mm from the planned trajectory; Class 2 (inaccurate), 2 mm or more but less than 4 mm; and Class 3 (deviated), 4 mm or more. In addition, to assess the safety of the screw insertion, malpositioning of the screws was also evaluated using the following grading system: Grade 0 (containing), a screw is completely within the wall of the bone structure; Grade 1 (exposure), a screw perforates the wall of the bone structure but more than 50% of the screw diameter remains within the bone; Grade 2 (perforation), a screw perforates the bone structures and more than 50% of the screw diameter is outside the pedicle; and Grade 3 (penetration), a screw perforates completely outside the bone structure. RESULTS: In total, 47 (97.9%) of 48 screws were classified into Class 1 and Grade 0, whereas 1 laminar screw was classified as Class 3 and Grade 2. Mean screw deviations were 0.36 mm in the axial plane (range 0.0-3.8 mm) and 0.30 mm in the sagittal plane (range 0.0-0.8 mm). CONCLUSIONS: This study demonstrates that the SGT system provided extremely accurate C-2 cervical screw insertion without configuration of reference points, high-dose radiation from intraoperative 3D navigation, or any registration or probing error evoked by changes in spinal alignment during surgery. A multistep screw placement technique and reliable screw guide cylinders were the key to accurate screw placement using the SGT system.


Assuntos
Parafusos Ósseos , Vértebras Cervicais/cirurgia , Doenças da Coluna Vertebral/cirurgia , Fusão Vertebral/instrumentação , Idoso , Idoso de 80 Anos ou mais , Vértebras Cervicais/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Interpretação de Imagem Radiográfica Assistida por Computador , Doenças da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento
8.
J Neurosurg Spine ; 19(2): 185-90, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23705628

RESUMO

OBJECT: Pedicle screw fixation is a standard procedure of spinal instrumentation, but accurate screw placement is essential to avoid injury to the adjacent structures, such as the vessels, nerves, and viscera. The authors recently developed an intraoperative screw guiding method in which patient-specific laminar templates were used, and verified the accuracy of the multistep procedure in the thoracic spine. METHODS: Preoperative bone images of the CT scans were analyzed using 3D/multiplanar imaging software and the trajectories of the screws were planned. Plastic templates with screw guiding structures were created for each lamina by using 3D design and printing technology. Three types of templates were made for precise multistep guidance, and all templates were specially designed to fit and lock on the lamina during the procedure. Plastic vertebra models were also generated and preoperative screw insertion simulation was performed. Surgery was performed using this patient-specific screw guide template system, and the placement of screws was postoperatively evaluated using CT scanning. RESULTS: Ten patients with thoracic or cervicothoracic pathological entities were selected to verify this novel procedure. Fifty-eight pedicle screws were placed using the screw guide template system. Preoperatively, each template was found to fit exactly and to lock on the lamina of the vertebra models, and screw insertion simulation was successfully performed. Intraoperatively the templates also fit and locked on the patient lamina, and screw insertion was completed successfully. Postoperative CT scans confirmed that no screws violated the cortex of the pedicles, and the mean deviation of the screws from the planned trajectories was 0.87 ± 0.34 mm at the coronal midpoint section of the pedicles. CONCLUSIONS: The multistep, patient-specific screw guide template system is useful for intraoperative pedicle screw navigation in the thoracic spine. This simple and economical method can improve the accuracy of pedicle screw insertion and reduce the operating time and radiation exposure of spinal fixation surgery.


Assuntos
Parafusos Ósseos/normas , Procedimentos Ortopédicos/métodos , Doenças da Coluna Vertebral/cirurgia , Vértebras Torácicas/cirurgia , Adulto , Idoso , Desenho de Equipamento/instrumentação , Desenho de Equipamento/métodos , Desenho de Equipamento/normas , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Procedimentos Ortopédicos/instrumentação , Procedimentos Ortopédicos/normas , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/normas , Tomografia Computadorizada por Raios X , Resultado do Tratamento
9.
Spine (Phila Pa 1976) ; 36(23): E1509-14, 2011 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-21221053

RESUMO

STUDY DESIGN: Retrospective consecutive cohort study. OBJECTIVE: To study the effectiveness of ß-tricalcium phosphate (ß-TCP) granules as a packing material in the titanium cages for anterior cervical discectomy and fusion (ACDF), compared with the conventional hydroxyapatite (HA) granules. SUMMARY OF BACKGROUND DATA: ACDF using titanium cages is a standard procedure for the treatment of cervical spinal degenerative diseases. Synthetic bone substitutes are widely used to pack the titanium cage to augment intervertebral bony fusion, but the efficacy has not been confirmed. METHODS: Fusion condition was evaluated on lateral radiographs and computed tomography. Complete fusion of the treated segments was defined by three criteria: movement of the spinous process at flexion and extension positions of less than 3 mm, bony bridging between vertebral bodies, and absence of the halo around the titanium cage. The evaluation was performed at 6 months, 1 year, and 2 years after surgery. RESULTS: Intervertebral fusion was studied in patients who underwent ACDF using ß-TCP (93 segments of 57 patients) or HA (72 segments of 48 patients) packing of cylindrical titanium cages. Complete fusion rate at 6 months and 1 year was significantly better in the ß-TCP group (46% at 6 months and 69% at 1 year) than in the HA group (24% at 6 months and 49% at 1 year), but the rate was similar at 2 years in the ß-TCP group (94%) and the HA group (90%). There were no material-related adverse effects. CONCLUSION: Satisfactory final fusion rates were obtained after ACDF using both ß-TCP- and HA-packed titanium cages. ß-TCP showed higher fusion rate in the early stage after surgery and can be recommended as a bone substitute for ACDF with titanium cages.


Assuntos
Fosfatos de Cálcio/uso terapêutico , Vértebras Cervicais/cirurgia , Discotomia/métodos , Fusão Vertebral/métodos , Titânio , Adulto , Idoso , Materiais Biocompatíveis/uso terapêutico , Vértebras Cervicais/diagnóstico por imagem , Discotomia/instrumentação , Durapatita/uso terapêutico , Feminino , Seguimentos , Humanos , Fixadores Internos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Radiografia , Estudos Retrospectivos , Fusão Vertebral/instrumentação , Fatores de Tempo , Resultado do Tratamento
10.
Spine (Phila Pa 1976) ; 34(6): 551-5, 2009 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-19282734

RESUMO

STUDY DESIGN: Myelopathy symptoms were prospectively studied in patients with cervical spinal canal stenosis (CSCS), using objective grading systems and stabilometry, to examine the effect of administration of prostaglandin E1 derivative limaprost alfadex (limaprost). OBJECTIVE: Myelopathy scores/grades and stabilometry parameters were evaluated before, and 1 and 3 months after starting the limaprost treatment. SUMMARY AND BACKGROUND DATA: Limaprost is a potent vasodilator and antiplatelet agent and has been used to treat the symptoms of lumbar spinal canal stenosis. The action presumably involves increased blood flow in the compressed cauda equina. Limaprost can also increase blood flow in the compressed spinal cord, but effects on myelopathy symptoms in patients with CSCS have not been established. METHODS: This study examined 21 patients with mild spondylotic CSCS based on neurologic findings and compression of the cervical spinal cord on magnetic resonance imaging. Japanese Orthopedic Association score, grip and release test, and finger escape sign were measured, and stabilometry was performed by independent examiners, before, and 1 and 3 months after starting the oral limaprost treatment. RESULTS: Most patients experienced amelioration of the symptoms at 1 month after starting the treatment. Mean Japanese Orthopedic Association score and grip and release count were significantly improved and finger escape sign grade was higher in some patients. Stabilometry area with eyes closed and Romberg rate were also significantly improved. These improvements were maintained at 3 months. CONCLUSION: The efficacy of oral limaprost administration for patients with CSCS was confirmed by objective scoring and quantitative data.


Assuntos
Alprostadil/análogos & derivados , Inibidores da Agregação Plaquetária/administração & dosagem , Estenose Espinal/tratamento farmacológico , Espondilose/complicações , Vasodilatadores/administração & dosagem , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Alprostadil/administração & dosagem , Vértebras Cervicais , Tontura/tratamento farmacológico , Tontura/etiologia , Tontura/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Destreza Motora/efeitos dos fármacos , Equilíbrio Postural/efeitos dos fármacos , Estudos Prospectivos , Estenose Espinal/etiologia , Estenose Espinal/patologia , Espondilose/patologia , Resultado do Tratamento
11.
Acta Neurochir (Wien) ; 151(4): 303-9; discussion 309, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19262984

RESUMO

BACKGROUND: Anterior cervical discectomy and fusion (ACDF) is widely performed for the treatment of cervical spinal degenerative disease. Autogenic or allogenic bone grafts are used for interbody fusion with satisfactory long term outcomes. However, harvest of the autograft causes donor site complications and allograft is associated with low fusion rate. Threaded titanium cages (TC) have recently been introduced to cope with these disadvantages, but there is little evidence of long term results. METHODS: The long term outcome was studied after ACDF using TC. Clinical and imaging follow up was performed in 41 patients for at least 5 years (range 5-8.3 years). New computer-assisted measurement methods for radiographs are proposed. FINDINGS: ACDF with TC achieved 80% excellent or good outcome by Odom's criteria, 95% fusion rate, and few minor complications. Asymptomatic adjacent disc degeneration was detected in 50% of the patients by our measurement methods. However, symptomatic adjacent disc degeneration occurred in 5% of the patients and only 2% required additional surgery. CONCLUSIONS: These results are comparable or better than those after ACDF with autograft or allograft. ACDF with TC can achieve rigid fixation and provide good long term results.


Assuntos
Vértebras Cervicais/cirurgia , Discotomia/efeitos adversos , Fixadores Internos/efeitos adversos , Deslocamento do Disco Intervertebral/epidemiologia , Deslocamento do Disco Intervertebral/cirurgia , Fusão Vertebral/efeitos adversos , Adulto , Idoso , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/patologia , Discotomia/instrumentação , Discotomia/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Fixadores Internos/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Cuidados Pós-Operatórios/métodos , Complicações Pós-Operatórias/epidemiologia , Radiografia , Radiologia/métodos , Estudos Retrospectivos , Prevenção Secundária , Fusão Vertebral/instrumentação , Fusão Vertebral/estatística & dados numéricos , Tempo , Titânio/uso terapêutico , Resultado do Tratamento
12.
Neurosurgery ; 57(4 Suppl): 290-4; discussion 290-4, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16234677

RESUMO

OBJECTIVE: Extradural or subcutaneous cerebrospinal fluid (CSF) leakage is a common complication after spinal surgery and is associated with the risks of poor wound healing, meningitis, and pseudomeningocele. Numerous methods to prevent postoperative CSF leakage are available, but pressure-tight dural closure remains difficult, especially with synthetic surgical membranes. The efficacy of a novel dural closure technique was assessed by detecting extradural or subcutaneous CSF leakage on magnetic resonance imaging. METHODS: The novel dural closure technique using absorbable polyglactin acid sheet and fibrin glue and the conventional procedure using only fibrin glue were evaluated retrospectively by identifying extradural or subcutaneous CSF leakage on magnetic resonance imaging scans in the acute (2-7 d) and chronic (3-6 mo) postoperative stages after spinal intradural surgery in 53 patients. RESULTS: The incidence of extradural and subcutaneous CSF leakage was significantly lower (P < 0.05) in the acute (20%) and chronic (0%) stages using polyglactin acid sheet and fibrin glue in 15 patients compared with that in the acute (81%) and chronic (24%) stages using only fibrin glue in 38 patients. One patient in the fibrin glue-only group required repair surgery for cutaneous CSF leakage. CONCLUSION: The combination of polyglactin acid sheet and fibrin glue can achieve water-tight closure after spinal intradural surgery and can minimize the risk of intractable postoperative CSF leakage. This simple, economical technique is recommended for dural closure after spinal intradural surgery.


Assuntos
Otorreia de Líquido Cefalorraquidiano/etiologia , Rinorreia de Líquido Cefalorraquidiano/etiologia , Adesivo Tecidual de Fibrina , Procedimentos Neurocirúrgicos/efeitos adversos , Ácido Poliglicólico , Complicações Pós-Operatórias , Adolescente , Adulto , Idoso , Otorreia de Líquido Cefalorraquidiano/prevenção & controle , Otorreia de Líquido Cefalorraquidiano/cirurgia , Rinorreia de Líquido Cefalorraquidiano/prevenção & controle , Rinorreia de Líquido Cefalorraquidiano/cirurgia , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Doenças da Coluna Vertebral/classificação , Doenças da Coluna Vertebral/cirurgia , Técnicas de Sutura , Resultado do Tratamento
13.
No Shinkei Geka ; 33(2): 163-8, 2005 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-15714962

RESUMO

Spontaneous spinal epidural hematoma (SSEH) is a rare clinical entity. Although approximately 500 cases have been reported, controversy exists concerning timing of the treatment and the validity of decompression surgery. We recently encountered four cases of SSEH. Evacuation of the hematoma was carried out in two patients with severe or persistent neurological deficits. Other two patients were treated conservatively because of the rapid resolution of the symptoms. All four patients improved after the treatment; three patients fully recovered and one patient required rehabilitation for moderate quadriparesis. Many previous reports recommended decompression surgery within 48 hours after the onset, however, one patient in our series fully recovered after surgery 4 days after the onset. We reviewed 183 operative cases of SSEH with incomplete neurological deficits in the literature and found that 93% of the patients who underwent surgery more than 48 hours after symptom onset showed good neurological recovery. Conservative treatment should be undertaken for rapidly improving patients, but surgical intervention should be considered in symptomatic patients regardless of the time from the onset.


Assuntos
Hematoma Epidural Espinal/cirurgia , Medula Espinal/cirurgia , Adolescente , Idoso , Feminino , Hematoma Epidural Espinal/diagnóstico , Hematoma Epidural Espinal/fisiopatologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
14.
No Shinkei Geka ; 32(9): 937-44, 2004 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-15529771

RESUMO

We reported a rare case of cervical glioblastoma with intracranial dissemination at an early stage of clinical course and reviewed the literature. An 8-year-old girl presented with failure of vision 3 months prior to admission to our hospital. Neurological examination on admission disclosed no definitive abnormalities except for bilateral visual disturbance and optic atrophy. Cranial MR images revealed a homogeneously enhancing tumor in the left sylvian fissure. Multiple spotty T2-hyperintensity lesions without contrast enhancement were also disclosed in bilateral cerebellum. Spinal MR images showed an enhancing tumor at C7 and tiny enhancing lesions on the surface of T11. The patient underwent an uneventful excision of the exophytic tumor at C7. The histological diagnosis was glioblastoma. The enhancing tumor in the left sylvian fissure treated by Linac stereotactic radiotherapy with a marginal dose of 38.4Gy in 12 fractions has diminished, whereas the residual tumor at C7 remained unchanged after radiation of 44Gy. In contrast, the multiple spotty lesions without contrast enhancement dispersedly spread in the cerebellum and infiltrated into brain stem despite 4 courses of chemotherapy using ifosfamide, cisplatin, and etoposide. Stereotactic biopsy of the multiple spotty lesions in the cerebellum was performed. Histological examination revealed anaplastic astrocytoma. The patient died 2 weeks after the biopsy despite additional chemotherapy and focal irradiation to the cerebellum. Early detection and selection of optimal therapeutic strategies are important in management of spinal glioblastoma with subarachnoid dissemination, since neuroradiological findings and therapeutic sensitivity are varied according to differentiation of disseminated tumors.


Assuntos
Neoplasias Encefálicas/secundário , Glioblastoma/secundário , Imageamento por Ressonância Magnética , Neoplasias da Medula Espinal/patologia , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/radioterapia , Vértebras Cervicais/patologia , Criança , Terapia Combinada , Feminino , Glioblastoma/diagnóstico , Glioblastoma/radioterapia , Humanos
15.
No Shinkei Geka ; 32(6): 619-25, 2004 Jun.
Artigo em Japonês | MEDLINE | ID: mdl-15352632

RESUMO

We reported a rare case of supratentorial primitive neuroectodermal tumors (sPNET) and reviewed the literature. A 15-year-old girl presented with a one-month history of headache and vomiting. CT scans showed a huge, solid and cystic tumor with calcification, occupying the left anterior cranial fossa. The solid portion of the tumor was hypointense on T1-weighted images, slightly hyperintense on T2-weighted images, hyperintense on diffusion- weighted images, isointense on fluid-attenuated inversion recovery (FLAIR) images, and strongly enhanced after administration of contrast medium. The expansile tumor had a broad attachment to the dura matter of the anterior cranial fossa. The patient underwent an uneventful extirpation of the tumor. Microscopically, the solid tumor contained small, round poorly-differentiated cells with pleomorphic nuclei and brisk mitotic activity. The tumor cells were immunoreactive for synaptophysin and GFAP, whereas lack of MIC2 gene product expression was confirmed using the monoclonal antibody 12E7. The MIB-1-positive rate was 43%. The histological diagnosis was sPNET. Postoperatively, a dose of 30.6Gy was administrated to the whole brain and a boost of 19.6Gy to the T2-hyperintensity lesion. The patient successively received a dose of 30.4Gy to the whole spine and Linac stereotactic radiotherapy with a marginal dose of 16.8Gy at the tumor bed. Three months after radiotherapy the patient received chemotherapy using carboplatin and etoposide. Follow-up MR images showed no evidence of recurrent tumor 5 months after the radiochemotherapy. On the basis of MR findings on both diffusion-weighted and FLAIR images, preoperative diagnosis of sPNET may be important for choosing appropriate therapeutic strategies for this tumor.


Assuntos
Tumores Neuroectodérmicos Primitivos/cirurgia , Neoplasias Supratentoriais/cirurgia , Adolescente , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Tumores Neuroectodérmicos Primitivos/diagnóstico , Tumores Neuroectodérmicos Primitivos/patologia , Procedimentos Neurocirúrgicos , Neoplasias Supratentoriais/diagnóstico , Neoplasias Supratentoriais/patologia
16.
J Neurosurg ; 100(1): 146-9, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14743928

RESUMO

Vascular closure staple clips made of titanium were originally developed for microvascular anastomosis. Clinical applications for these clips include arteriotomy closure for carotid endarterectomy, extracranial-intracranial bypass, and dural closure. This is the first report in which vascular closure staple clips have been used successfully for direct repair of a tear on the internal carotid artery (ICA). This report involves a 65-year-old man who presented with sudden onset of headache. Admission computerized tomography scans demonstrated a diffuse and thick subarachnoid hemorrhage in the basal cisterns. Cerebral angiograms demonstrated a broad-based, small bulge on the superomedial wall of the left ICA. Intraoperatively, an extremely thin-walled aneurysm was seen on the segment of the ICA at the C-2 vertebral level. The aneurysm ruptured abruptly, although no surgical manipulation was being performed on the aneurysm itself. After temporary clips were applied on the vessel, a large tear of the ICA was repaired with vascular closure staple clips. Reconstruction with the vascular closure staple clips required only a short period of temporary occlusion of the ICA. Postoperative angiograms revealed reduction of the aneurysm bulge and good patency of the ICA. The postoperative course was uneventful, and the patient has been free of symptoms. The vascular closure staple clipping procedure is useful for urgent repair of an aneurysm tear. This method is a new treatment option for these fragile aneurysms in cases in which other options, such as encircling clips or bypass procedures, may have drawbacks or be impossible.


Assuntos
Doenças das Artérias Carótidas/cirurgia , Artéria Carótida Interna/cirurgia , Aneurisma Intracraniano/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos , Idoso , Doenças das Artérias Carótidas/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Angiografia Cerebral , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Instrumentos Cirúrgicos , Procedimentos Cirúrgicos Vasculares/instrumentação
17.
No Shinkei Geka ; 30(12): 1315-22, 2002 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-12491583

RESUMO

We report a rare case of a primary intracerebral malignant fibrous histiocytoma (MFH) with malignant progression from a premalignant stage. A 73-year-old male presented with mild hemiparesis on the right side of his body 4 months prior to admission. MR images showed a homogenously enhanced mass in the left parietal lobe. The patient underwent an uneventful extirpation of the solid mass. Microscopically, the solid tumor contained histiocytic cells and spindle-shaped fibroblastic cells arranged in a storiform pattern. The tumor cells were immunoreactive for vimentin, MAC 387 (macrophage marker) and alpha-1-antitrypsin. The MIB-1-positive rate was 1%. The histological diagnosis was fibrous histiocytoma. Postoperative MR images demonstrated no abnormally enhanced lesions. The patient's neurological symptoms and signs gradually improved. One year after surgery, he developed right hemiparesis. MR images showed a heterogeneously enhanced mass in the left sensorimotor area. This recurrent tumor was totally resected. Microscopically, the tumor was composed of atypical spindle-shaped cells, forming a storiform pattern. Pleomorphism was prominent, and necrotic foci were also seen. The MIB-1 labeling index averaged 11%. The histological findings corresponded to those of MFH. Unfortunately, the patient died of interstitial pneumonia contracted during postoperative radiotherapy. Early detection and resection at a stage of low malignant potential, followed by radiochemotherapy, are crucial for the management of this mesenchymal tumor.


Assuntos
Neoplasias Encefálicas/cirurgia , Histiocitoma Fibroso Benigno/cirurgia , Idoso , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/patologia , Angiografia Cerebral , Diagnóstico Diferencial , Glioma/diagnóstico , Histiocitoma Fibroso Benigno/diagnóstico , Histiocitoma Fibroso Benigno/patologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Dosagem Radioterapêutica , Radioterapia Adjuvante
18.
J Neurosurg ; 96(4): 788-91, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11990822

RESUMO

A 47-year-old man presented with a superior hypophyseal artery aneurysm and an ipsilateral posterior communicating artery aneurysm. Both lesions were successfully clipped without removal of the anterior clinoid process or retraction of the optic nerve by using endoscopic guidance. The endoscope was introduced into the prechiasmatic cistern and provided a clear visual field around the aneurysm that could not be seen via the operating microscope. The endoscope was useful in the identification of the medially projecting lesion and the small perforating branches of the ophthalmic segment of the internal carotid artery. A fenestrated clip could be introduced around the neck of the aneurysm and placed in the best position under endoscopic guidance. Endoscopy-assisted clipping is potentially a very useful procedure for aneurysm surgery.


Assuntos
Aneurisma/cirurgia , Endoscopia , Doenças da Hipófise/cirurgia , Hipófise/irrigação sanguínea , Hipófise/cirurgia , Osso Esfenoide/cirurgia , Instrumentos Cirúrgicos , Aneurisma/diagnóstico por imagem , Aneurisma/patologia , Angiografia , Artérias/patologia , Artérias/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Doenças da Hipófise/diagnóstico por imagem , Doenças da Hipófise/patologia , Hipófise/patologia , Osso Esfenoide/diagnóstico por imagem , Osso Esfenoide/patologia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA