Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Cochrane Database Syst Rev ; (2): CD010339, 2015 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-25719222

RESUMO

BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) and intraoperative cholangiography (IOC) are tests used in the diagnosis of common bile duct stones in people suspected of having common bile duct stones. There has been no systematic review of the diagnostic accuracy of ERCP and IOC. OBJECTIVES: To determine and compare the accuracy of ERCP and IOC for the diagnosis of common bile duct stones. SEARCH METHODS: We searched MEDLINE, EMBASE, Science Citation Index Expanded, BIOSIS, and Clinicaltrials.gov to September 2012. To identify additional studies, we searched the references of included studies and systematic reviews identified from various databases (Database of Abstracts of Reviews of Effects (DARE)), Health Technology Assessment (HTA), Medion, and ARIF (Aggressive Research Intelligence Facility)). We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. SELECTION CRITERIA: We included studies that provided the number of true positives, false positives, false negatives, and true negatives for ERCP or IOC. We only accepted studies that confirmed the presence of common bile duct stones by extraction of the stones (irrespective of whether this was done by surgical or endoscopic methods) for a positive test, and absence of common bile duct stones by surgical or endoscopic negative exploration of the common bile duct, or symptom-free follow-up for at least six months for a negative test as the reference standard in people suspected of having common bile duct stones. We included participants with or without prior diagnosis of cholelithiasis; with or without symptoms and complications of common bile duct stones; with or without prior treatment for common bile duct stones; and before or after cholecystectomy. At least two authors screened abstracts and selected studies for inclusion independently. DATA COLLECTION AND ANALYSIS: Two authors independently collected data from each study. We used the bivariate model to summarise the sensitivity and specificity of the tests. MAIN RESULTS: We identified five studies including 318 participants (180 participants with and 138 participants without common bile duct stones) that reported the diagnostic accuracy of ERCP and five studies including 654 participants (125 participants with and 529 participants without common bile duct stones) that reported the diagnostic accuracy of IOC. Most studies included people with symptoms (participants with jaundice or pancreatitis) suspected of having common bile duct stones based on blood tests, ultrasound, or both, prior to the performance of ERCP or IOC. Most studies included participants who had not previously undergone removal of the gallbladder (cholecystectomy). None of the included studies was of high methodological quality as evaluated by the QUADAS-2 tool (quality assessment tool for diagnostic accuracy studies). The sensitivities of ERCP ranged between 0.67 and 0.94 and the specificities ranged between 0.92 and 1.00. For ERCP, the summary sensitivity was 0.83 (95% confidence interval (CI) 0.72 to 0.90) and specificity was 0.99 (95% CI 0.94 to 1.00). The sensitivities of IOC ranged between 0.75 and 1.00 and the specificities ranged between 0.96 and 1.00. For IOC, the summary sensitivity was 0.99 (95% CI 0.83 to 1.00) and specificity was 0.99 (95% CI 0.95 to 1.00). For ERCP, at the median pre-test probability of common bile duct stones of 0.35 estimated from the included studies (i.e., 35% of people suspected of having common bile duct stones were confirmed to have gallstones by the reference standard), the post-test probabilities associated with positive test results was 0.97 (95% CI 0.88 to 0.99) and negative test results was 0.09 (95% CI 0.05 to 0.14). For IOC, at the median pre-test probability of common bile duct stones of 0.35, the post-test probabilities associated with positive test results was 0.98 (95% CI 0.85 to 1.00) and negative test results was 0.01 (95% CI 0.00 to 0.10). There was weak evidence of a difference in sensitivity (P value = 0.05) with IOC showing higher sensitivity than ERCP. There was no evidence of a difference in specificity (P value = 0.7) with both tests having similar specificity. AUTHORS' CONCLUSIONS: Although the sensitivity of IOC appeared to be better than that of ERCP, this finding may be unreliable because none of the studies compared both tests in the same study populations and most of the studies were methodologically flawed. It appears that both tests were fairly accurate in guiding further invasive treatment as most people diagnosed with common bile duct stones by these tests had common bile duct stones. Some people may have common bile duct stones in spite of having a negative ERCP or IOC result. Such people may have to be re-tested if the clinical suspicion of common bile duct stones is very high because of their symptoms or persistently abnormal liver function tests. However, the results should be interpreted with caution given the limited quantity and quality of the evidence.


Assuntos
Colangiografia , Colangiopancreatografia Retrógrada Endoscópica , Coledocolitíase/diagnóstico por imagem , Humanos , Período Intraoperatório , Ensaios Clínicos Controlados Aleatórios como Assunto , Sensibilidade e Especificidade
2.
Cochrane Database Syst Rev ; (2): CD011548, 2015 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-25719223

RESUMO

BACKGROUND: Ultrasound and liver function tests (serum bilirubin and serum alkaline phosphatase) are used as screening tests for the diagnosis of common bile duct stones in people suspected of having common bile duct stones. There has been no systematic review of the diagnostic accuracy of ultrasound and liver function tests. OBJECTIVES: To determine and compare the accuracy of ultrasound versus liver function tests for the diagnosis of common bile duct stones. SEARCH METHODS: We searched MEDLINE, EMBASE, Science Citation Index Expanded, BIOSIS, and Clinicaltrials.gov to September 2012. We searched the references of included studies to identify further studies and systematic reviews identified from various databases (Database of Abstracts of Reviews of Effects, Health Technology Assessment, Medion, and ARIF (Aggressive Research Intelligence Facility)). We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. SELECTION CRITERIA: We included studies that provided the number of true positives, false positives, false negatives, and true negatives for ultrasound, serum bilirubin, or serum alkaline phosphatase. We only accepted studies that confirmed the presence of common bile duct stones by extraction of the stones (irrespective of whether this was done by surgical or endoscopic methods) for a positive test result, and absence of common bile duct stones by surgical or endoscopic negative exploration of the common bile duct, or symptom-free follow-up for at least six months for a negative test result as the reference standard in people suspected of having common bile duct stones. We included participants with or without prior diagnosis of cholelithiasis; with or without symptoms and complications of common bile duct stones, with or without prior treatment for common bile duct stones; and before or after cholecystectomy. At least two authors screened abstracts and selected studies for inclusion independently. DATA COLLECTION AND ANALYSIS: Two authors independently collected data from each study. Where meta-analysis was possible, we used the bivariate model to summarise sensitivity and specificity. MAIN RESULTS: Five studies including 523 participants reported the diagnostic accuracy of ultrasound. One studies (262 participants) compared the accuracy of ultrasound, serum bilirubin and serum alkaline phosphatase in the same participants. All the studies included people with symptoms. One study included only participants without previous cholecystectomy but this information was not available from the remaining studies. All the studies were of poor methodological quality. The sensitivities for ultrasound ranged from 0.32 to 1.00, and the specificities ranged from 0.77 to 0.97. The summary sensitivity was 0.73 (95% CI 0.44 to 0.90) and the specificity was 0.91 (95% CI 0.84 to 0.95). At the median pre-test probability of common bile duct stones of 0.408, the post-test probability (95% CI) associated with positive ultrasound tests was 0.85 (95% CI 0.75 to 0.91), and negative ultrasound tests was 0.17 (95% CI 0.08 to 0.33).The single study of liver function tests reported diagnostic accuracy at two cut-offs for bilirubin (greater than 22.23 µmol/L and greater than twice the normal limit) and two cut-offs for alkaline phosphatase (greater than 125 IU/L and greater than twice the normal limit). This study also assessed ultrasound and reported higher sensitivities for bilirubin and alkaline phosphatase at both cut-offs but the specificities of the markers were higher at only the greater than twice the normal limit cut-off. The sensitivity for ultrasound was 0.32 (95% CI 0.15 to 0.54), bilirubin (cut-off greater than 22.23 µmol/L) was 0.84 (95% CI 0.64 to 0.95), and alkaline phosphatase (cut-off greater than 125 IU/L) was 0.92 (95% CI 0.74 to 0.99). The specificity for ultrasound was 0.95 (95% CI 0.91 to 0.97), bilirubin (cut-off greater than 22.23 µmol/L) was 0.91 (95% CI 0.86 to 0.94), and alkaline phosphatase (cut-off greater than 125 IU/L) was 0.79 (95% CI 0.74 to 0.84). No study reported the diagnostic accuracy of a combination of bilirubin and alkaline phosphatase, or combinations with ultrasound. AUTHORS' CONCLUSIONS: Many people may have common bile duct stones in spite of having a negative ultrasound or liver function test. Such people may have to be re-tested with other modalities if the clinical suspicion of common bile duct stones is very high because of their symptoms. False-positive results are also possible and further non-invasive testing is recommended to confirm common bile duct stones to avoid the risks of invasive testing.It should be noted that these results were based on few studies of poor methodological quality and the results for ultrasound varied considerably between studies. Therefore, the results should be interpreted with caution. Further studies of high methodological quality are necessary to determine the diagnostic accuracy of ultrasound and liver function tests.


Assuntos
Coledocolitíase/diagnóstico por imagem , Coledocolitíase/diagnóstico , Testes de Função Hepática , Fosfatase Alcalina/sangue , Bilirrubina/sangue , Biomarcadores/sangue , Humanos , Ultrassonografia
3.
Cochrane Database Syst Rev ; (2): CD011549, 2015 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-25719224

RESUMO

BACKGROUND: Endoscopic ultrasound (EUS) and magnetic resonance cholangiopancreatography (MRCP) are tests used in the diagnosis of common bile duct stones in patients suspected of having common bile duct stones prior to undergoing invasive treatment. There has been no systematic review of the accuracy of EUS and MRCP in the diagnosis of common bile duct stones using appropriate reference standards. OBJECTIVES: To determine and compare the accuracy of EUS and MRCP for the diagnosis of common bile duct stones. SEARCH METHODS: We searched MEDLINE, EMBASE, Science Citation Index Expanded, BIOSIS, and Clinicaltrials.gov until September 2012. We searched the references of included studies to identify further studies and of systematic reviews identified from various databases (Database of Abstracts of Reviews of Effects (DARE), Health Technology Assessment (HTA), Medion, and ARIF (Aggressive Research Intelligence Facility)). We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. SELECTION CRITERIA: We included studies that provided the number of true positives, false positives, false negatives, and true negatives for EUS or MRCP. We only accepted studies that confirmed the presence of common bile duct stones by extraction of the stones (irrespective of whether this was done by surgical or endoscopic methods) for a positive test, and absence of common bile duct stones by surgical or endoscopic negative exploration of the common bile duct or symptom free follow-up for at least six months for a negative test, as the reference standard in people suspected of having common bile duct stones. We included participants with or without prior diagnosis of cholelithiasis; with or without symptoms and complications of common bile duct stones, with or without prior treatment for common bile duct stones; and before or after cholecystectomy. At least two authors independently screened abstracts and selected studies for inclusion. DATA COLLECTION AND ANALYSIS: Two authors independently collected the data from each study. We used the bivariate model to obtain pooled estimates of sensitivity and specificity. MAIN RESULTS: We included a total of 18 studies involving 2366 participants (976 participants with common bile duct stones and 1390 participants without common bile duct stones). Eleven studies evaluated EUS alone, and five studies evaluated MRCP alone. Two studies evaluated both tests. Most studies included patients who were suspected of having common bile duct stones based on abnormal liver function tests; abnormal transabdominal ultrasound; symptoms such as obstructive jaundice, cholangitis, or pancreatitis; or a combination of the above. The proportion of participants who had undergone cholecystectomy varied across studies. Not one of the studies was of high methodological quality. For EUS, the sensitivities ranged between 0.75 and 1.00 and the specificities ranged between 0.85 and 1.00. The summary sensitivity (95% confidence interval (CI)) and specificity (95% CI) of the 13 studies that evaluated EUS (1537 participants; 686 cases and 851 participants without common bile duct stones) were 0.95 (95% CI 0.91 to 0.97) and 0.97 (95% CI 0.94 to 0.99). For MRCP, the sensitivities ranged between 0.77 and 1.00 and the specificities ranged between 0.73 and 0.99. The summary sensitivity and specificity of the seven studies that evaluated MRCP (996 participants; 361 cases and 635 participants without common bile duct stones) were 0.93 (95% CI 0.87 to 0.96) and 0.96 (95% CI 0.90 to 0.98). There was no evidence of a difference in sensitivity or specificity between EUS and MRCP (P value = 0.5). From the included studies, at the median pre-test probability of common bile duct stones of 41% the post-test probabilities (with 95% CI) associated with positive and negative EUS test results were 0.96 (95% CI 0.92 to 0.98) and 0.03 (95% CI 0.02 to 0.06). At the same pre-test probability, the post-test probabilities associated with positive and negative MRCP test results were 0.94 (95% CI 0.87 to 0.97) and 0.05 (95% CI 0.03 to 0.09). AUTHORS' CONCLUSIONS: Both EUS and MRCP have high diagnostic accuracy for detection of common bile duct stones. People with positive EUS or MRCP should undergo endoscopic or surgical extraction of common bile duct stones and those with negative EUS or MRCP do not need further invasive tests. However, if the symptoms persist, further investigations will be indicated. The two tests are similar in terms of diagnostic accuracy and the choice of which test to use will be informed by availability and contra-indications to each test. However, it should be noted that the results are based on studies of poor methodological quality and so the results should be interpreted with caution. Further studies that are of high methodological quality are necessary to determine the diagnostic accuracy of EUS and MRCP for the diagnosis of common bile duct stones.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Coledocolitíase/diagnóstico por imagem , Coledocolitíase/diagnóstico , Endossonografia , Colangiopancreatografia por Ressonância Magnética/normas , Endossonografia/normas , Humanos , Sensibilidade e Especificidade
4.
Resuscitation ; 82(2): 190-4, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21075499

RESUMO

INTRODUCTION: Effective chest compression is an integral part of good quality cardiopulmonary resuscitation. There remains uncertainty over the optimal method for identifying the correct hand position for chest compression. The aim of this study was to identify the relationship between basic life support (BLS) providers assessment of the inter-nipple line (INL) versus the centre of the chest (CoC) and to identify the anatomical structures underneath these landmarks. METHOD: Thirty consecutive patients having elective CT scans of the thorax were recruited and photographs of the patient fully clothed were taken in the supine position. 30 healthcare students trained in BLS were asked to mark the 'point between the nipples' and the 'centre of the chest' on each photograph in a random sequence. Corresponding points were marked on the CT images and the underlying anatomical structures were identified. RESULTS: Hand positions using CoC landmark were significantly higher and were more variable than INL landmark (measurement represented as ratio of sternal length: mean CoC 0.709, 95% CI 0.677, 0.740 versus mean INL 0.803 95% CI 0.772, 0.835; p<0.0001). Structures underneath CoC and INL hand positions were significantly different; CoC compressing predominantly the aortic arch and ascending aorta and INL compressing the left ventricle and left ventricular outflow (p<0.001). Hand positions were not significantly affected by gender of patients. CONCLUSION: Both the centre of the chest landmark and inter-nipple line identify positions on the lower third of the sternum. The centre of the chest technique identifies a point that is consistently higher and more variable than the inter-nipple line. Structures compressed under both landmarks were different although the implications of this are unknown.


Assuntos
Reanimação Cardiopulmonar/métodos , Tórax/anatomia & histologia , Tomografia Computadorizada por Raios X , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mamilos , Radiografia Torácica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA