Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(13)2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-39000910

RESUMO

Exercise is a front-line intervention to increase functional capacity and reduce pain and disability in people with low strength levels or disorders. However, there is a lack of validated field-based tests to check the initial status and, more importantly, to control the process and make tailored adjustments in load, intensity, and recovery. We aimed to determine the test-retest reliability of a submaximal, resistance-band test to evaluate the strength of the trunk stability muscles using a portable force sensor in middle-aged adults (48 ± 13 years) with medically diagnosed chronic low back pain and healthy peers (n = 35). Participants completed two submaximal progressive tests of two resistance-band exercises (unilateral row and Pallof press), consisting of 5 s maintained contraction, progressively increasing the load. The test stopped when deviation from the initial position by compensation movements occurred. Trunk muscle strength (CORE muscles) was monitored in real time using a portable force sensor (strain gauge). Results revealed that both tests were highly reliable (intra-class correlation [ICC] > 0.901) and presented low errors and coefficients of variation (CV) in both groups. In particular, people with low back pain had errors of 14-19 N (CV = 9-12%) in the unilateral row test and 13-19 N (CV = 8-12%) in the Pallof press. No discomfort or pain was reported during or after the tests. These two easy-to-use and technology-based tests result in a reliable and objective screening tool to evaluate the strength and trunk stability in middle-aged adults with chronic low back pain, considering an error of measurement < 20 N. This contribution may have an impact on improving the individualization and control of rehabilitation or physical training in people with lumbar injuries or disorders.


Assuntos
Dor Lombar , Força Muscular , Humanos , Dor Lombar/fisiopatologia , Força Muscular/fisiologia , Pessoa de Meia-Idade , Masculino , Feminino , Adulto , Reprodutibilidade dos Testes , Tronco/fisiopatologia , Tronco/fisiologia , Treinamento Resistido/métodos , Dor Crônica/fisiopatologia , Dor Crônica/diagnóstico , Músculo Esquelético/fisiopatologia , Músculo Esquelético/fisiologia
2.
Sensors (Basel) ; 24(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38544265

RESUMO

We aimed to determine the feasibility, test-retest reliability and long-term stability of a novel method for assessing the force (torque)-velocity (cadence) profile and maximal dynamic force (MDF) during leg-pedaling using a friction-loaded isoinertial cycle ergometer and a high-precision power-meter device. Fifty-two trained male cyclists completed a progressive loading test up to the one-repetition maximum (1RM) on a cycle ergometer. The MDF was defined as the force attained at the cycle performed with the 1RM-load. To examine the test-retest reliability and long-term stability of torque-cadence values, the progressive test was repeated after 72 h and also after 10 weeks of aerobic and strength training. The participants' MDF averaged 13.4 ± 1.3 N·kg-1, which was attained with an average pedal cadence of 21 ± 3 rpm. Participants' highest power output value was attained with a cadence of 110 ± 16 rpm (52 ± 5% MDF). The relationship between the MDF and cadence proved to be very strong (R2 = 0.978) and independent of the cyclists' MDF (p = 0.66). Cadence values derived from this relationship revealed a very high test-retest repeatability (mean SEM = 4 rpm, 3.3%) and long-term stability (SEM = 3 rpm, 2.3%); despite increases in the MDF following the 10-week period. Our findings support the validity, reliability and long-term stability of this method for the assessment of the torque-cadence profile and MDF in cyclists.


Assuntos
Ciclismo , Ergometria , Humanos , Masculino , Torque , Reprodutibilidade dos Testes , , Teste de Esforço/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA