Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
PDA J Pharm Sci Technol ; 73(4): 345-355, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30770482

RESUMO

The pharmacopeia method for measuring the chemical durability of parenteral glass packaging is the hydrolytic resistance test in which the vial is filled to 90% of its brimful volume as described, for example, in USP <660>. However, an increasing number of innovative drugs are filled significantly below the nominal volume of the vial. As a consequence, the determined hydrolytic resistance is not representative of the concentrations of leached "glass" elements for low fill volumes. This is attributable to two main factors: Firstly, an increasing ratio of the wetted surface to volume and secondly an increased leaching tendency typically observed with borosilicate glass of the wall near bottom area, especially when standard manufacturing technology is applied.The extent of both contributing effects has been analyzed by determining the amounts of the representative leached "glass" elements, boron, sodium, and silicon, after vial storage for 24 weeks at 40°C with different fill volumes (0.5, 1.0, and 2.0 mL). The vials which have been investigated in this study have a nominal fill volume of 2 mL, were made from Type I class B borosilicate glass (Fiolax®) and from aluminosilicate glass and were filled with either purified water or a 15% KCl solution.The standard conversion process for tubing into vials was used for Fiolax vials (standard quality vials) and for aluminosilicate vials. In addition, an optimized conversion process (delamination controlled technology) was used to create low-fill quality Fiolax vials. The vial quality obtained from the two different converting technologies greatly influenced the concentrations of leached "glass" elements measured, especially when low fill volumes were used.LAY ABSTRACT: Borosilicate glass containers, because of their chemical inertness, excellent barrier properties, high transparency, and mechanical stability, have been successfully used for decades to package parenteral drug formulations. Nevertheless, Type I glass can be altered over a period of time when in contact with the drug formulation. The result of this interaction is even more pronounced for some new innovative drugs that are delivered to the patient in small dosages significantly below the nominal storage capacity of the glass vials. When the fill volume of the vials is reduced, the contribution of the bottom area to the wetted surface increases, resulting in a higher surface-to-volume ratio. Therefore, the concentrations of leached elements will be increased and this can cause problems for sensitive medical products. This effect is not usually observed with the standard test procedures described in the pharmacopeia because the vials are filled with a high volume to 90% brimful capacity (e.g., as described in USP <660>). In this study, the leachable behaviors of vials made of borosilicate and aluminosilicate glass were evaluated by using medium and low fill volumes with storage for 24 weeks at 40°C. The standard conversion process to manufacture a vial from glass tubing introduces volatile "glass" elements into the vial wall near the bottom area. This mechanism has been described and supported by time-of-flight secondary ion mass spectrometry (TOF-SIMS) measurements of the inner vial surface as reported by Rupertus et al. The diffusion mechanism of volatile components will increase the leaching propensity of the vial, especially for low fill volumes. However, innovative manufacturing techniques are able to avoid the diffusion of volatile elements into the wall near the bottom area. This is achieved by a specific process setup in combination with a suitable monitoring test during vial production, which gives a quantitative measure of the leaching tendency of the wall near the bottom area. Borosilicate glass vials manufactured with this setup (low-fill quality vials) showed a drastic reduction in leachables, especially with low fill volumes. Vials composed of a boron-free glass showed no advantages in terms of leaching behavior when compared with borosilicate glass vials in general.


Assuntos
Silicatos de Alumínio/química , Embalagem de Medicamentos/métodos , Vidro/química , Preparações Farmacêuticas/normas , Silicatos de Alumínio/normas , Química Farmacêutica , Embalagem de Medicamentos/normas , Armazenamento de Medicamentos/métodos , Armazenamento de Medicamentos/normas , Vidro/normas , Concentração de Íons de Hidrogênio , Hidrólise , Preparações Farmacêuticas/química , Propriedades de Superfície
2.
PDA J Pharm Sci Technol ; 70(6): 560-567, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27325595

RESUMO

Delamination of flakes in glass containers used for primary drug packaging has become a serious quality concern in recent years. Because glass delamination typically occurs weeks/months after filling and there are a variety of container, processing and drug formulation factors that contribute to glass delamination, it is recommended according to USP <1660> (1) to conduct suitable container/drug product compatibility tests. Such predictive studies should give results that allow a graduated assessment for increasing risk of delamination that can be used to detect early stages of this phenomenon and to help to select appropriate container/formulation systems to proactively prevent delamination instead of just monitoring for the presence/absence of flakes. This work demonstrates the capability of a container compatibility testing approach by determining the impact of three different model buffer/solution systems (citrate, phosphate and sodium bicarbonate) with the delamination behavior of two different types of 2 mL glass vials, standard quality and delamination controlled quality. Vials of each type were filled and stored up to 48 weeks at 40 °C. Using a USP <1660>-compatible package of different analytical methods clearly demonstrates the significant influence of both vial quality and chemistry of the content on glass delamination propensity.LAY ABSTRACT The detachment of flakes from the inner surface of a glass container-also referred to as delamination-has become a serious quality concern over the last years for the pharmaceutical industry. Chapter <1660> of the United Stated Pharmacopeia therefore recommends performing predictive screening studies with the drug formulation and the glass container to evaluate the risk of delamination in an early stage of the drug development. Predictive screening studies have been performed with three different representative buffer/solution and glass vials of two different quality steps (standard and delamination controlled). The results demonstrate the capability of container compatibility testing and the influence of vial quality and chemistry of the content on glass delamination propensity.


Assuntos
Soluções Tampão , Embalagem de Medicamentos , Vidro
3.
PDA J Pharm Sci Technol ; 68(4): 373-80, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25035259

RESUMO

Glass delamination has developed as a quality problem for primary packaging containers over the last years. Beside other factors the container production process can contribute to this phenomenon, and it seems mandatory to steer and control the critical parameters. With the Schott Delamination Quicktest, a rapid test method is developed that provides a rough measure for the container-related properties that affect delamination risk in a simple and reliable manner and in a relatively short time span. The application of this testing method minimizes the risk of unexpected corrosion behavior and can be used as a release criterion for the running production. LAY ABSTRACT: If pharmaceutical products do not match properly with the glass containers used, the creation of delaminated glass flakes can occur. This process is slow and time-dependent and mostly visible after month or years. With the Schott Delamination Quicktest a rapid method is developed that provides a fast measure for a rough indication of a higher risk for a delamination behavior. The application of the test gives quick evidence and can be used as a release criterion.


Assuntos
Embalagem de Medicamentos , Vidro , Corrosão , Manufaturas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA