Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Endosc Int Open ; 11(9): E920-E927, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37810901

RESUMO

Background and study aims The newly introduced G-EYE colonoscope (G-EYE) employs a balloon, installed at the bending section of a standard colonoscope (SC), for increasing adenoma detection and stabilizing the colonoscope tip during intervention. This retrospective work explores the effect of introducing G-EYE into an SC endoscopy room, in terms of adenoma detection and polyp removal time. Patients and methods This was a single-center, retrospective study. Historical data from patients who underwent colonoscopy prior to, and following, introduction of G-EYE into a particular endoscopy room were collected and analyzed to determine adenoma detection rate (ADR), adenoma per patient (APP), and polyp removal time (PRT), in each of the SC and G-EYE groups. Results Records of 1362 patients who underwent SC and 1433 subsequent patients who underwent G-EYE colonoscopy in the same endoscopy unit by the same endoscopists were analyzed. Following G-EYE introduction, overall ADR increased by 37.5 % ( P  < 0.0001) from 39.2 % to 53.9 %, the serrated adenoma rate increased by 47.3 % from 27.9 % to 41.1 % ( P  < 0.0001), and the APP increased by 50.6 % from 0.79 to 1.19 ( P  < 0.0001). The number of advanced adenomas increased by 32.7 %, from 19.6 % to 26.0 % of all adenomas ( P  < 0.0001). With G-EYE, average PRT was reduced overall by 29.5 % ( P  < 0.0001), and particularly for endoscopic mucosal resection (EMR) by 37.5 % for polyps measuring ≥ 5 mm to ≤ 20 mm ( P  < 0.0001) and by 29.4 % for large polyps > 20 mm ( P  < 0.0001). Conclusions Introduction of G-EYE to an SC endoscopy room yielded considerable increase in ADR and notable reduction in PRT, particularly with the EMR technique. G-EYE balloon colonoscopy might increase the effectiveness of colorectal cancer screening and surveillance colonoscopy, and can shorten the time of endoscopic intervention.

2.
Visc Med ; 37(5): 358-371, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34722719

RESUMO

BACKGROUND: Endoscopic resection of dysplastic lesions in early stages of cancer reduces mortality rates and is recommended by many national guidelines throughout the world. Snare polypectomy and endoscopic mucosal resection (EMR) are established techniques of polyp removal. The advantages of these methods are their relatively short procedure times and acceptable complication rates. The latter include delayed bleeding in 0.9% and a perforation risk of 0.4-1.3%, depending on the size and location of the resected lesion. EMR is a recent modification of endoscopic resection. A limited number of studies suggest that larger lesions can be removed en bloc with low complication rates and short procedure times. Novel techniques such as endoscopic submucosal dissection (ESD) are used to enhance en bloc resection rates for larger, flat, or sessile lesions. Endoscopic full-thickness resection (EFTR) is employed for non-lifting lesions or those not easily amenable to resection. Procedures such as ESD or EFTR are emerging standards for lesions inaccessible to EMR techniques. SUMMARY: Endoscopic treatment is now regarded as first-line therapy for benign lesions. KEY MESSAGE: Endoscopic resection of dysplastic lesions or early stages of cancer is recommended. A plethora of different techniques can be used dependent on the lesions.

3.
Eur J Gastroenterol Hepatol ; 33(1S Suppl 1): e662-e669, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34034272

RESUMO

AIM: The use of artificial intelligence represents an objective approach to increase endoscopist's adenoma detection rate (ADR) and limit interoperator variability. In this study, we evaluated a newly developed deep convolutional neural network (DCNN) for automated detection of colorectal polyps ex vivo as well as in a first in-human trial. METHODS: For training of the DCNN, 116 529 colonoscopy images from 278 patients with 788 different polyps were collected. A subset of 10 467 images containing 504 different polyps were manually annotated and treated as the gold standard. An independent set of 45 videos consisting of 15 534 single frames was used for ex vivo performance testing. In vivo real-time detection of colorectal polyps during routine colonoscopy by the DCNN was tested in 42 patients in a back-to-back approach. RESULTS: When analyzing the test set of 15 534 single frames, the DCNN's sensitivity and specificity for polyp detection and localization within the frame was 90% and 80%, respectively, with an area under the curve of 0.92. In vivo, baseline polyp detection rate and ADR were 38% and 26% and significantly increased to 50% (P = 0.023) and 36% (P = 0.044), respectively, with the use of the DCNN. Of the 13 additionally with the DCNN detected lesions, the majority were diminutive and flat, among them three sessile serrated adenomas. CONCLUSION: This newly developed DCNN enables highly sensitive automated detection of colorectal polyps both ex vivo and during first in-human clinical testing and could potentially increase the detection of colorectal polyps during colonoscopy.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Adenoma/diagnóstico por imagem , Adenoma/patologia , Inteligência Artificial , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/patologia , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Computadores , Humanos , Redes Neurais de Computação
4.
West J Nurs Res ; 43(3): 250-260, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33073733

RESUMO

Health care errors are a national concern. Although considerable attention has been placed on reducing errors since a 2000 Institute of Medicine report, adverse events persist. The purpose of this pilot study was to evaluate the effect of mindfulness training, employing the standardized approach of an eight-week mindfulness-based, stress reduction program on reduction of nurse errors in simulated clinical scenarios. An experimental, pre- and post-test control group design was employed with 20 staff nurses and senior nursing students. Although not statistically significant, there were numerical differences in clinical performance scores from baseline when comparing mindfulness and control groups immediately following mindfulness training and after three months. A number of benefits of mindfulness training, such as improved listening skills, were identified. This pilot study supports the benefits of mindfulness training in improving nurse clinical performance and illustrates a novel approach to employ in future research.


Assuntos
Transtornos Mentais , Atenção Plena , Estudantes de Enfermagem , Humanos , Projetos Piloto , Estresse Psicológico/prevenção & controle
5.
Therap Adv Gastroenterol ; 13: 1756284820954112, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33101457

RESUMO

The therapeutic management of patients with severe steroid-refractory ulcerative colitis still represents a critical clinical challenge. In this setting, cyclosporin is an effective and rapidly acting induction treatment that is applied in combination with maintenance therapeutic agents like thiopurines or vedolizumab. Here, we present the case of a 33-year-old ulcerative colitis patient with severe steroid-refractory ulcerative colitis who refused surgical intervention and previously demonstrated no long-term benefit to anti-TNF antibody, vedolizumab, cyclosporin, thiopurines or tofacitinib treatment. Intravenous cyclosporin therapy was re-initiated in the patient and, after signs of clinical response, therapy with ustekinumab was additionally applied. After 11 weeks of well tolerated cyclosporin and ustekinumab combination therapy, cyclosporin was discontinued upon clinical and endoscopic remission. Subsequently, ustekinumab treatment has been effective in maintaining remission during the follow-up period of 195 days.

6.
Visc Med ; 36(2): 95-103, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32355666

RESUMO

BACKGROUND: The advancement of innovative endoscopic technology in terms of improving the visualization of the mucosa has been of significant benefit. SUMMARY: Advancements in image resolution, software processing, and optical filter technology have resulted in several techniques complemental to traditional white light endoscopy. These new techniques provide a real-time optical diagnosis as well as virtual histology of detected lesions. Optical molecular imaging permits a functional assessment within cells. KEY MESSAGE: Optical molecular imaging provides an understanding of cellular processes and permits validation of the specificity of fluorescent tracers and the possibility of quantifying the signal.

7.
World J Gastroenterol ; 26(16): 1962-1970, 2020 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-32390706

RESUMO

BACKGROUND: The adenoma detection rate (ADR) is inversely associated with the incidence of interval colorectal cancer and serves as a benchmark quality criterion during screening colonoscopy. However, adenoma miss rates reach up to 26% and studies have shown that a second inspection of the right colon in retroflected view (RFV) can increase ADR. AIM: To assess whether inspection of the whole colon in RFV compared to standard forward view (SFV) can increase ADR. METHODS: Patients presenting for screening or surveillance colonoscopy were invited to participate in this randomized controlled trial and randomized into two arms. In RFV arm colonoscopy was initially performed with SFV, followed by a second inspection of the whole colon in RFV. In the SFV arm first withdrawal was performed with SFV, followed by a second inspection of the whole colon again with SFV. Number, size and morphology of polyps found during first and second inspection in each colonic segment were recorded and all polyps were removed and sent for histopathology in separate containers. RESULTS: Two hundred and five patients were randomly assigned to the RFV (n = 101) and SFV (n = 104) arm. In the RFV arm, both polyp detection rate (PDR) and ADR were increased under second inspection in RFV (PDR 1st SFV: 39.8%, PDR 2nd RFV: 46.6%; ADR 1st SFV: 35.2%, ADR 2nd RFV: 42%). Likewise, in the SFV arm, PDR and ADR were increased under second inspection (PDR 1st SFV: 37.5%, PDR 2nd SFV: 46.6%; ADR 1st SFV: 34.1%, ADR 2nd SFV: 44.3%) with no significant differences in ADR and PDR between the SFV and RFV arm. Mean number of adenomas per patient (APP) was increased in the RFV and SFV (APP RFV arm: 1st SFV: 1.71; 2nd RFV: 2.38; APP SFV arm: 1st SFV: 1.83, 2nd SFV:2.2). The majority of adenomas additionally found during second inspection in RFV or in SFV were located in the transverse and left-sided colon and were > 5 mm in size. CONCLUSION: Second inspection of the whole colon leads to increased adenoma detection with no differences between SFV and RFV. Hence, increased detection is most likely a feature of the second inspection itself but not of the inspection mode.


Assuntos
Adenoma/diagnóstico , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Programas de Rastreamento/métodos , Adenoma/epidemiologia , Adenoma/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Colo/diagnóstico por imagem , Colo/patologia , Colonoscopia/estatística & dados numéricos , Neoplasias Colorretais/epidemiologia , Neoplasias Colorretais/patologia , Detecção Precoce de Câncer/estatística & dados numéricos , Feminino , Humanos , Mucosa Intestinal/diagnóstico por imagem , Mucosa Intestinal/patologia , Masculino , Programas de Rastreamento/estatística & dados numéricos , Pessoa de Meia-Idade , Adulto Jovem
8.
Gastrointest Endosc ; 89(3): 545-553, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30273591

RESUMO

BACKGROUND AND AIMS: Colorectal cancer (CRC) is largely preventable with routine screening and surveillance colonoscopy; however, interval cancers arising from precancerous lesions missed by standard colonoscopy still occur. An increased adenoma detection rate (ADR) has been found to be inversely associated with interval cancers. The G-EYE device includes a reusable balloon integrated at the distal tip of a standard colonoscope, which flattens haustral folds, centralizes the colonoscope's optics, and reduces bowel slippage. The insufflated balloon also aims to enhance visualization of the colon during withdrawal, thereby increasing the ADR. METHODS: In this randomized, controlled, international, multicenter study (11 centers), patients (aged ≥50 years) referred to colonoscopy for screening, surveillance, or changes in bowel habits were randomized to undergo either balloon-assisted colonoscopy by using an insufflated balloon during withdrawal or standard high-definition colonoscopy. The primary endpoint was the ADR. RESULTS: One thousand patients were enrolled between May 2014 and September 2016 to undergo colonoscopy by experienced endoscopists; 803 were finally analyzed (standard colonoscopy n = 396; balloon-assisted colonoscopy n = 407). Baseline parameters were similar in both groups. Balloon-assisted colonoscopy provided a 48.0% ADR compared with 37.5% in the standard colonoscopy group (28% increase; P = .0027). Additionally, balloon-assisted colonoscopy provided for a significant increase in detection of advanced (P = .0033) flat adenomas (P < .0001) and sessile serrated adenomas/polyps (P = .0026). CONCLUSION: Balloon-assisted colonoscopy yielded a higher ADR and increased the detection of advanced, flat, and sessile serrated adenomas/polyps when compared with standard colonoscopy. Improved detection by the G-EYE device could impact the quality of CRC screening by reducing miss rates and consequently reducing interval cancer incidence. (Clinical trial registration number: NCT01917513.).


Assuntos
Adenoma/diagnóstico , Pólipos do Colo/diagnóstico , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Pólipos Adenomatosos/diagnóstico , Assistência ao Convalescente , Idoso , Colonoscópios , Colonoscopia/instrumentação , Detecção Precoce de Câncer , Fezes/química , Feminino , Hemoglobinas/análise , Humanos , Imunoquímica , Masculino , Pessoa de Meia-Idade
10.
Endoscopy ; 50(8): 779-789, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29571175

RESUMO

BACKGROUND: Prediction of histology of small polyps facilitates colonoscopic treatment. The aims of this study were: 1) to develop a simplified polyp classification, 2) to evaluate its performance in predicting polyp histology, and 3) to evaluate the reproducibility of the classification by trainees using multiplatform endoscopic systems. METHODS: In phase 1, a new simplified endoscopic classification for polyps - Simplified Identification Method for Polyp Labeling during Endoscopy (SIMPLE) - was created, using the new I-SCAN OE system (Pentax, Tokyo, Japan), by eight international experts. In phase 2, the accuracy, level of confidence, and interobserver agreement to predict polyp histology before and after training, and univariable/multivariable analysis of the endoscopic features, were performed. In phase 3, the reproducibility of SIMPLE by trainees using different endoscopy platforms was evaluated. RESULTS: Using the SIMPLE classification, the accuracy of experts in predicting polyps was 83 % (95 % confidence interval [CI] 77 % - 88 %) before and 94 % (95 %CI 89 % - 97 %) after training (P â€Š= 0.002). The sensitivity, specificity, positive predictive value, and negative predictive value after training were 97 %, 88 %, 95 %, and 91 %. The interobserver agreement of polyp diagnosis improved from 0.46 (95 %CI 0.30 - 0.64) before to 0.66 (95 %CI 0.48 - 0.82) after training. The trainees demonstrated that the SIMPLE classification is applicable across endoscopy platforms, with similar post-training accuracies for narrow-band imaging NBI classification (0.69; 95 %CI 0.64 - 0.73) and SIMPLE (0.71; 95 %CI 0.67 - 0.75). CONCLUSIONS: Using the I-SCAN OE system, the new SIMPLE classification demonstrated a high degree of accuracy for adenoma diagnosis, meeting the ASGE PIVI recommendations. We demonstrated that SIMPLE may be used with either I-SCAN OE or NBI.


Assuntos
Adenoma/classificação , Adenoma/patologia , Pólipos do Colo/classificação , Pólipos do Colo/patologia , Colonoscopia/instrumentação , Neoplasias Colorretais/classificação , Neoplasias Colorretais/patologia , Adenoma/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia/educação , Neoplasias Colorretais/diagnóstico por imagem , Consenso , Técnica Delphi , Gastroenterologia/educação , Humanos , Imagem de Banda Estreita , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Carga Tumoral
11.
Z Gastroenterol ; 2018 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-29426056

RESUMO

BACKGROUND AND AIMS: The most commonly missed polyps in colonoscopy are those located behind haustral folds. The G-EYE system is a standard colonoscope consisting of re-processable balloon at its distal tip. The G-EYE balloon improves the detection of polyps by straightening the haustral folds. In our back-to-back tandem study, we aimed to determine whether and to what extent the G-EYE system could reduce adenoma miss rates in screening colonoscopy. METHODS: Patients referred to colonoscopy were randomized into 2 groups. Group A underwent a standard colonoscopy (SC) followed by balloon colonoscopy (BC), and Group B underwent BC followed by SC. In this randomized tandem study, the investigator's level of training and the endoscopists themselves were changed after each withdrawal. Each endoscopist was blinded to the results of the first withdrawal. RESULTS: Fifty-eight patients were enrolled and randomized into 2 groups with similar baseline characteristics. Nine patients were excluded from the study. Twenty-five patients underwent SC followed by BC while 24 underwent BC followed by SC. The adenoma miss rate for SC was 41 %, with an additional detection rate of 69 % for BC (ratio 1.69). The overall miss rate for polyps was 60 % for SC, with an additional detection rate of 150 % for BC (ratio 2.5). Experienced investigators who used BC were able to identify an additional 7 polyps while inexperienced investigators. CONCLUSIONS: Although our results could not clearly confirm that BC improves adenoma detection, the investigator's experience appears to be a major determinant of the adenoma detection rate.

12.
Z Gastroenterol ; 2018 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-29426055

RESUMO

BACKGROUND: Suspected gastrointestinal (GI) bleeding is a common initial diagnosis in emergency departments. Despite existing endoscopic scores to estimate the risk of GI bleeding, the primary clinical assessment of urgency can remain challenging. The 5-step Manchester Triage System (MTS) is a validated score that is often applied for the initial assessment of patients presenting in emergency departments. METHODS: All computer-based records of patients who were admitted between January 2014 and December 2014 to our emergency department in a tertiary referral hospital were analyzed retrospectively. The aim of our retrospective analysis was to determine if patient triage using the MTS is associated with rates of endoscopy and with presence of active GI bleeding. RESULTS: In summary, 5689 patients with a GI condition were treated at our emergency department. Two hundred eighty-four patients (4.9 %) presented with suspected GI bleeding, and 165 patients (58 %) received endoscopic diagnostic. Endoscopic intervention for hemostasis was needed in 34 patients (21 %). In patients who underwent emergency endoscopy, triage into MTS categories with higher urgency was associated with higher rates of endoscopic confirmation of suspected GI bleeding (79 % of patients with MTS priority levels 1 or 2, 53 % in level 3 patients, and 40 % in levels 4 or 5 patients; p = 0.024). CONCLUSIONS: The MTS is an established tool for triage in emergency departments and could have a potential to guide early clinical decision-making with regards to urgency of endoscopic evaluation in patients with suspected GI bleeding.

13.
Nat Rev Gastroenterol Hepatol ; 14(7): 421-434, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28611477

RESUMO

Multimodality imaging is an essential aspect of endoscopic surveillance for the detection of neoplastic lesions, such as dysplasia or intramucosal cancer, because it improves the efficacy of endoscopic surveillance and therapeutic procedures in the gastrointestinal tract. This approach reveals mucosal abnormalities that cannot be detected by standard endoscopy. Currently, these imaging techniques are divided into those for primary detection and those for targeted imaging and characterization, the latter being used to visualize areas of interest in detail and permit histological evaluation. This Review outlines the use of virtual chromoendoscopy, narrow-band imaging, autofluorescence imaging, optical coherence tomography, confocal endomicroscopy and volumetric laser endomicroscopy as new imaging techniques for diagnostic investigation of the gastrointestinal tract. Insights into use of multimodal endoscopic imaging for early disease detection, in particular for pre-malignant lesions, in the oesophagus, stomach and colon are described.


Assuntos
Endoscopia Gastrointestinal/métodos , Neoplasias Gastrointestinais/diagnóstico , Imagem Multimodal/métodos , Esôfago de Barrett/diagnóstico , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Humanos , Microscopia Confocal/métodos , Imagem Óptica/métodos , Lesões Pré-Cancerosas/diagnóstico , Neoplasias Gástricas/diagnóstico , Tomografia de Coerência Óptica/métodos
14.
Dig Liver Dis ; 49(7): 721-727, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28454854

RESUMO

Worldwide, colorectal cancer is the third commonest cancer. Over 90% follow an adenoma-to-cancer sequence over many years. Colonoscopy is the gold standard method for cancer screening and early adenoma detection. However, considerable variation exists between endoscopists' detection rates. This review considers the effects of different endoscopic techniques on adenoma detection. Two areas of technological interest were considered: (1) optical technologies and (2) mechanical technologies. Optical solutions, including FICE, NBI, i-SCAN and high definition colonoscopy showed mixed results. In contrast, mechanical advances, such as cap-assisted colonoscopy, FUSE, EndoCuff and G-EYE™, showed promise, with reported detections rates of up to 69%. However, before definitive recommendations can be made for their incorporation into daily practice, further studies and comparison trials are required.


Assuntos
Adenoma/diagnóstico , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Pólipos do Colo/diagnóstico , Colonoscópios , Colonoscopia/instrumentação , Detecção Precoce de Câncer , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
15.
Surg Endosc ; 31(7): 2753-2762, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28039647

RESUMO

BACKGROUND: Surgically altered gastrointestinal anatomy poses challenges for deep enteroscopy. Current overtube-assisted methods have long procedure times and utilize endoscopes with smaller working channels that preclude use of standard accessories. A through-the-scope balloon-assisted enteroscopy (TTS-BAE) device uses standard endoscopes with a large working channel to allow metallic and plastic stent insertion. We aim to determine the efficacy and safety of TTS-BAE in patients with altered surgical anatomy. METHODS: A retrospective, multicenter study of TTS-BAE in altered anatomy patients at two USA and one German institution was performed between January 2013 and December 2014. Type of anatomy, procedure indication and duration, adverse events, and target, technical, and clinical success were recorded. RESULTS: A total of 32 patients (mean age 54 years, Caucasian 81.6%, female 42.1%, mean BMI 25.4 kg/m2) underwent 38 TTS-BAE procedures. Thirty-two percent of cases had a prior attempt at conventional enteroscopy which failed to reach the target site. The target was successfully reached in 23 (60.5%) cases. Of the 23 cases that reached the intended target, 22 (95.7%) achieved technical success and 21 (91.3%) achieved clinical success. The median procedure time was 43 min. Target, technical, and clinical success rates for TTS-BAE-assisted ERCP (n = 31) were 58.1, 54.8 and 54.8%. Seven self-expandable metallic stents (five biliary, two jejunal) were attempted, and all successfully deployed. Adverse events occurred in 4 (10.4%) cases, including one luminal perforation. CONCLUSION: TTS-BAE is an alternative to overtube-assisted enteroscopy that is comparable in safety in patients with surgically altered anatomies. Technical success in the instances where the target had been reached was excellent. TTS-BAE confers an advantage over overtube-assisted enteroscopy as it can facilitate the deployment of self-expandable metallic stents in the biliary tree and deep small bowel.


Assuntos
Enteroscopia de Balão/métodos , Intestino Delgado/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Adulto , Idoso , Enteroscopia de Balão/instrumentação , Colangiopancreatografia Retrógrada Endoscópica/métodos , Endoscópios , Feminino , Humanos , Intestino Delgado/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Stents Metálicos Autoexpansíveis
16.
Visc Med ; 33(4): 285-294, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38500535

RESUMO

Cancers at an early stage of disease with a low risk of lymph node metastases or distant spread can be managed endoscopically. Different endoscopic techniques can be applied in the gastrointestinal tract. Furthermore, endoscopic and laparoscopic surgery can be combined in specific indications today. Most of all, resection-related complications can also be solved endoscopically.

17.
BMC Gastroenterol ; 15: 145, 2015 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-26493200

RESUMO

BACKGROUND: Distal diminutive colorectal polyps are common and accurate endoscopic prediction of hyperplastic or adenomatous polyp histology could reduce procedural time, costs and potential risks associated with the resection. Within this study we assessed whether digital chromoendoscopy can accurately predict the histology of distal diminutive colorectal polyps according to the ASGE PIVI statement. METHODS: In this prospective cohort study, 224 consecutive patients undergoing screening or surveillance colonoscopy were included. Real time histology of 121 diminutive distal colorectal polyps was evaluated using high-definition endoscopy with digital chromoendoscopy and the accuracy of predicting histology with digital chromoendoscopy was assessed. RESULTS: The overall accuracy of digital chromoendoscopy for prediction of adenomatous polyp histology was 90.1 %. Sensitivity, specificity, positive and negative predictive values were 93.3, 88.7, 88.7, and 93.2 %, respectively. In high-confidence predictions, the accuracy increased to 96.3 % while sensitivity, specificity, positive and negative predictive values were calculated as 98.1, 94.4, 94.5, and 98.1 %, respectively. Surveillance intervals with digital chromoendoscopy were correctly predicted with >90 % accuracy. CONCLUSIONS: High-definition endoscopy in combination with digital chromoendoscopy allowed real-time in vivo prediction of distal colorectal polyp histology and is accurate enough to leave distal colorectal polyps in place without resection or to resect and discard them without pathologic assessment. This approach has the potential to reduce costs and risks associated with the redundant removal of diminutive colorectal polyps. TRIAL REGISTRATION: ClinicalTrials NCT02217449.


Assuntos
Colonoscopia/métodos , Aumento da Imagem/métodos , Pólipos Intestinais/patologia , Imagem Óptica/métodos , Vigilância da População/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias do Colo/patologia , Colonoscopia/economia , Colonoscopia/estatística & dados numéricos , Feminino , Humanos , Hiperplasia/diagnóstico , Pólipos Intestinais/economia , Pólipos Intestinais/cirurgia , Masculino , Pessoa de Meia-Idade , Imagem Óptica/estatística & dados numéricos , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Adulto Jovem
18.
Dtsch Med Wochenschr ; 140(20): 1539-42, 2015 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-26445262

RESUMO

CASE HISTORY: A 66-year-old woman suffering from skin paleness and weakness presented an increasing hypochromic, microcytic anemia. Diagnostic: In an ambulant setting a capsule endoscopy of the small intestine was carried out because of multiple polyps of the colon (colonoscopy) in addition to non-invasive (Hämoccult-Test) and invasive (gastroscopy) diagnostic. The patient was then admitted to hospital to clarify a suspicious ulcer of the small bowl. According to biopsies taken via balloon enteroscopy, an adenocarcinoma of the small intestine was diagnosed. THERAPY AND CLINICAL COURSE: After staging and exploratory laparotomy, histology findings showed an advanced tumour stage. A palliative chemotherapy, analogue to colon cancer treatment, was conducted. CONCLUSION: Small bowel diagnostics should be carried out if the aetiology of an anemia is not certain with an existing polyposis of the colon. Individuals with personal or family history of cumulative colorectal adenomas should undergo assessment for an adenomatous polyposis syndrom.


Assuntos
Anemia Hipocrômica/diagnóstico , Anemia Hipocrômica/etiologia , Neoplasias do Colo/complicações , Neoplasias do Colo/diagnóstico , Idoso , Anemia Hipocrômica/prevenção & controle , Neoplasias do Colo/tratamento farmacológico , Diagnóstico Diferencial , Feminino , Humanos , Doenças Raras/complicações , Doenças Raras/diagnóstico , Doenças Raras/terapia
19.
World J Gastroenterol ; 21(26): 8184-94, 2015 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-26185393

RESUMO

AIM: To investigate the impact of JetPrep cleansing on adenoma detection rates. METHODS: In this prospective, randomized, crossover trial, patients were blindly randomized to an intervention arm or a control arm. In accordance with the risk profile for the development of colorectal carcinoma, the study participants were divided into high-risk and low-risk groups. Individuals with just one criterion (age > 70 years, adenoma in medical history, and first-degree relative with colorectal cancer) were regarded as high-risk patients. Bowel preparation was performed in a standardized manner one day before the procedure. Participants in the intervention arm underwent an initial colonoscopy with standard bowel cleansing using a 250-mL syringe followed by a second colonoscopy that included irrigation by the use of the JetPrep cleansing system. The reverse sequence was used in the control arm. The study participants were divided into a high-risk group and a low-risk group according to their respective risk profiles for the development of colorectal carcinoma. RESULTS: A total of 64 patients (34 men and 30 women) were included in the study; 22 were included in the high-risk group. After randomization, 30 patients were assigned to the control group (group A) and 34 to the intervention group (group B). The average Boston Bowel Preparation Scale score was 5.15 ± 2.04. The withdrawal time needed for the first step was significantly longer in group A using the JetPrep system (9.41 ± 3.34 min) compared to group B (7.5 ± 1.92 min). A total of 163 polyps were discovered in 64 study participants who underwent both investigation steps. In group A, 49.4% of the polyps were detected during the step of standard bowel cleansing while the miss rate constituted 50.7%. Group B underwent cleansing with the JetPrep system during the first examination step, and as many as 73.9% of polyps were identified during this step. Thus, the miss rate in group B was a mere 26.1% (P < 0.001). When considering only the right side of the colon, the miss rate in group A during the first examination was 60.6%, in contrast to a miss rate of 26.4% in group B (P < 0.001). CONCLUSION: JetPrep is recommended for use during colonoscopy because a better prepared bowel enables a better adenoma detection, particularly in the proximal colon.


Assuntos
Adenoma/patologia , Pólipos Adenomatosos/patologia , Pólipos do Colo/patologia , Colonoscopia , Neoplasias Colorretais/patologia , Detecção Precoce de Câncer/instrumentação , Detecção Precoce de Câncer/métodos , Irrigação Terapêutica/instrumentação , Adenoma/genética , Pólipos Adenomatosos/genética , Idoso , Pólipos do Colo/genética , Colonoscopia/efeitos adversos , Neoplasias Colorretais/genética , Estudos Cross-Over , Erros de Diagnóstico/prevenção & controle , Detecção Precoce de Câncer/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Fatores de Risco , Irrigação Terapêutica/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA