Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMC Pregnancy Childbirth ; 24(1): 136, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38355457

RESUMO

BACKGROUND: While the effectiveness of cardiotocography in reducing neonatal morbidity is still debated, it remains the primary method for assessing fetal well-being during labor. Evaluating how accurately professionals interpret cardiotocography signals is essential for its effective use. The objective was to evaluate the accuracy of fetal hypoxia prediction by practitioners through the interpretation of cardiotocography signals and clinical variables during labor. MATERIAL AND METHODS: We conducted a cross-sectional online survey, involving 120 obstetric healthcare providers from several countries. One hundred cases, including fifty cases of fetal hypoxia, were randomly assigned to participants who were invited to predict the fetal outcome (binary criterion of pH with a threshold of 7.15) based on the cardiotocography signals and clinical variables. After describing the participants, we calculated (with a 95% confidence interval) the success rate, sensitivity and specificity to predict the fetal outcome for the whole population and according to pH ranges, professional groups and number of years of experience. Interobserver agreement and reliability were evaluated using the proportion of agreement and Cohen's kappa respectively. RESULTS: The overall ability to predict a pH level below 7.15 yielded a success rate of 0.58 (95% CI 0.56-0.60), a sensitivity of 0.58 (95% CI 0.56-0.60) and a specificity of 0.63 (95% CI 0.61-0.65). No significant difference in the success rates was observed with respect to profession and number of years of experience. The success rate was higher for the cases with a pH level below 7.05 (0.69) and above 7.20 (0.66) compared to those falling between 7.05 and 7.20 (0.48). The proportion of agreement between participants was good (0.82), with an overall kappa coefficient indicating substantial reliability (0.63). CONCLUSIONS: The use of an online tool enabled us to collect a large amount of data to analyze how practitioners interpret cardiotocography data during labor. Despite a good level of agreement and reliability among practitioners, the overall accuracy is poor, particularly for cases with a neonatal pH between 7.05 and 7.20. Factors such as profession and experience level do not present notable impact on the accuracy of the annotations. The implementation and use of a computerized cardiotocography analysis software has the potential to enhance the accuracy to detect fetal hypoxia, especially for ambiguous cardiotocography tracings.


Assuntos
Cardiotocografia , Hipóxia Fetal , Gravidez , Recém-Nascido , Feminino , Humanos , Cardiotocografia/métodos , Hipóxia Fetal/diagnóstico , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Transversais , Frequência Cardíaca Fetal
3.
Front Pediatr ; 11: 1190441, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37397139

RESUMO

Introduction: Cardiotocography, which consists in monitoring the fetal heart rate as well as uterine activity, is widely used in clinical practice to assess fetal wellbeing during labor and delivery in order to detect fetal hypoxia and intervene before permanent damage to the fetus. We present DeepCTG® 1.0, a model able to predict fetal acidosis from the cardiotocography signals. Materials and methods: DeepCTG® 1.0 is based on a logistic regression model fed with four features extracted from the last available 30 min segment of cardiotocography signals: the minimum and maximum values of the fetal heart rate baseline, and the area covered by accelerations and decelerations. Those four features have been selected among a larger set of 25 features. The model has been trained and evaluated on three datasets: the open CTU-UHB dataset, the SPaM dataset and a dataset built in hospital Beaujon (Clichy, France). Its performance has been compared with other published models and with nine obstetricians who have annotated the CTU-UHB cases. We have also evaluated the impact of two key factors on the performance of the model: the inclusion of cesareans in the datasets and the length of the cardiotocography segment used to compute the features fed to the model. Results: The AUC of the model is 0.74 on the CTU-UHB and Beaujon datasets, and between 0.77 and 0.87 on the SPaM dataset. It achieves a much lower false positive rate (12% vs. 25%) than the most frequent annotation among the nine obstetricians for the same sensitivity (45%). The performance of the model is slightly lower on the cesarean cases only (AUC = 0.74 vs. 0.76) and feeding the model with shorter CTG segments leads to a significant decrease in its performance (AUC = 0.68 with 10 min segments). Discussion: Although being relatively simple, DeepCTG® 1.0 reaches a good performance: it compares very favorably to clinical practice and performs slightly better than other published models based on similar approaches. It has the important characteristic of being interpretable, as the four features it is based on are known and understood by practitioners. The model could be improved further by integrating maternofetal clinical factors, using more advanced machine learning or deep learning approaches and having a more robust evaluation of the model based on a larger dataset with more pathological cases and covering more maternity centers.

4.
Fetal Diagn Ther ; 46(2): 103-110, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30308501

RESUMO

INTRODUCTION: Intra-amniotic inflammation is defined by elevated inflammatory biomarkers in the amniotic fluid (AF), either due to microbial invasion of the amniotic cavity (MIAC) or sterile inflammation. Amniocentesis being an invasive procedure, we wanted to investigate whether elevated matrix metalloproteinase-8 (MMP-8) or interleukin-6 (IL-6) concentrations could be detected from cervical fluid samples. MATERIALS AND METHODS: This prospective study included 67 women with singleton nondiabetic pregnancies with or without preterm premature rupture of membranes (PPROM) between 22+0 and 37+0 weeks of gestation. Simultaneous AF and cervical samples were obtained. RESULTS: In women without PPROM, cervical MMP-8 concentrations correlated with AF MMP-8 concentrations (rS = 0.466, p = 0.002), but cervical IL-6 did not correlate with AF IL-6 (rS = 0.277, p = 0.076). In PPROM cases no correlations were found. Women with MIAC had higher concentrations of AF MMP-8 and AF IL-6 compared to women without MIAC regardless of membrane status. However, only women without PPROM had higher concentrations of cervical MMP-8 in proven MIAC. CONCLUSION: In women without PPROM, cervical MMP-8 concentration reflects the magnitude of AF MMP-8, thus potentially guiding the selection of patients benefitting from amniocentesis.


Assuntos
Líquido Amniótico/metabolismo , Colo do Útero/metabolismo , Ruptura Prematura de Membranas Fetais/metabolismo , Interleucina-6/metabolismo , Metaloproteinase 8 da Matriz/metabolismo , Trabalho de Parto Prematuro/metabolismo , Biomarcadores/metabolismo , Técnicas de Diagnóstico Obstétrico e Ginecológico , Feminino , Humanos , Gravidez , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA