RESUMO
Ultrathin surface-tethered polymer brushes represent attractive platforms for a wide range of sensing applications in strategically vital areas such as medicine, forensics, or security. The recent trends in such developments towards "real world conditions" highlighted the role of zwitterionic poly(carboxybetaine) (pCB) brushes which provide excellent antifouling properties combined with bio-functionalization capacity. Highly dense pCB brushes are usually prepared by the "grafting from" polymerization triggered by initiators on self-assembled monolayers (SAMs). Here, multi-methodological experimental studies are pursued to elucidate the impact of the alkanethiolate SAM chain length (C6, C8 and C11) on structural and functional properties of antifouling poly(carboxybetaine methacrylamide) (pCBMAA) brush. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) in a custom-made 3D printed cell employing [Ru(NH3)6]3+/2+ redox probe were used to investigate penetrability of SAM/pCBMAA bilayers for small molecules and interfacial charge transfer characteristics. The biofouling resistance of pCBMAA brushes was characterized by surface plasmon resonance; ellipsometry and FT-IRRAS spectroscopy were used to determine swelling and relative density of the brushes synthesized from initiator-bearing SAMs with varied carbon chain length. The SAM length was found to have a substantial impact on all studied characteristics; the highest value of charge transfer resistance (Rct) was observed for denser pCBMAA on longer-chain (C11) SAM when compared to shorter (C8/C6) SAMs. The observed high value of Rct for C11 implies a limitation for the analytical performance of electrochemical sensing methods. At the same time, the pCBMAA brushes on C11 SAM exhibited the best bio-fouling resistance among inspected systems. This demonstrates that proper selection of supporting structures for brushes is critical in the design of these assemblies for biosensing applications.
RESUMO
Polymer brushes are frequently used as surface-tethered antifouling layers in biosensors to improve sensor surface-analyte recognition in the presence of abundant non-target molecules in complex biological samples by suppressing nonspecific interactions. However, because brushes are complex systems highly responsive to changes in their surrounding environment, studying their properties remains a challenge. Electrochemical impedance spectroscopy (EIS) is an emerging method in this context. In this mini review, we aim to elucidate the potential of EIS for investigating the physicochemical properties and structural aspects of polymer brushes. The application of EIS in brush-based biosensors is also discussed. Most common principles employed in these biosensors are presented, as well as interpretation of EIS data obtained in such setups. Overall, we demonstrate that the EIS-polymer brush pairing has a considerable potential for providing new insights into brush functionalities and designing highly sensitive and specific biosensors.
Assuntos
Técnicas Biossensoriais , Espectroscopia Dielétrica , PolímerosRESUMO
In recent years, the undeclared presence of various anabolic androgenic steroids (AAS) in commercial supplements has been confirmed. This fact can be a potential threat to all athletes using these supplements, and therefore, there is of increased interest in the implementation of rapid methods for the detection of AAS. The presented study describes the development of an immunostrip test for the detection of multiple 17α-methylated AAS based on direct and indirect competitive principle using gold nanoparticles as a label. As a capture reagent on test lines conjugated stanazolol to rabbit serum albumin (RSA/ST-3) was used, the intensity of color formed in the test line of the AAS-positive sample was visually distinguishable from that of negative sample within 10 min. The optimized closed direct and indirect format of the test provided a similar visual detection limit (0.7 and 0.9 ng/mL, respectively). The most commonly orally abused AAS (17α-methyltestosterone, methandienone, methyldihydrotestosterone, oxandrolone and oxymetholone) showed a strong cross-reaction. Developed immunostrips were successfully applied to analysis of artificially contaminated dietary supplements with 17α-methylated AASs. The developed immunostrips offer potential as a useful user-friendly method for capturing suspicious dietary supplement samples with different contents of AAS at levels far below the usually used concentrations of AAS.
RESUMO
Anabolic-androgenic steroids (AASs), a group of compounds frequently misused by athletes and, unfortunately, also by the general population, have lately attracted global attention; thus, significant demands for more precise, facile, and rapid AAS detection have arisen. The standard methods ordinarily used for AAS determination include liquid and gas chromatography coupled with mass spectrometry. However, good knowledge of steroid metabolism, pretreatment of samples (such as derivatization), and well-trained operators of the instruments are required, making this procedure expensive, complicated, and not routinely applicable. In the drive to meet current AAS detection demands, the scientific focus has shifted to developing novel, tailor-made approaches leading to time- and cost-effective, routine, and field-portable methods for AAS determination in various matrices, such as biological fluids, food supplements, meat, water, or other environmental components. Therefore, herein, we present a comprehensive review article covering recent advances in AAS determination, with a strong emphasis on the increasingly important role of chemically designed artificial sensors, biosensors, and antibody- and fluorescence-based methods.
Assuntos
Anabolizantes , Dopagem Esportivo , Androgênios , Atletas , Humanos , Esteroides , Congêneres da TestosteronaRESUMO
An urgent need to find an effective solution to bacterial resistance is pushing worldwide research for highly effective means against this threat. Newly prepared hybrid organosilane fibres consisting of a (1S,2S)-cyclohexane-1,2-diamine derivative, interconnected in the fibre network via covalent bonds, were fully characterised via different techniques, including FTIR, TGA-FTIR, SEM-EDS, and solid-state NMR. Fibrous samples were successfully tested against two types of pathogenic bacterial strains, namely Staphylococcus aureus, and Pseudomonas aeruginosa. The obtained results, showing >99.9% inhibition against Staphylococcus aureus and Pseudomonas aeruginosa in direct contact compared to the control, may help particularly in case of infections, where there is an urgent need to treat the infection in direct contact. From this point of view, the above-mentioned fibrous material may find application in wound healing. Moreover, this new material has a positive impact on fibroblasts viability.
RESUMO
Two valuable forensic tools based on enzyme-linked immunoassays (ELISAs) for the analysis of 17α-methylated steroids were developed using haptens of stanazolol and its conjugates with biotin. Haptens containing terminal carboxylic group were conjugated to bovine serum albumin (BSA), rabbit serum albumin (RSA) or ovalbumin (OVA). Eight batches of antisera (RAbs) obtained by immunization of rabbits were tested in an indirect competitive ELISA system using immobilization of RSA conjugate (RSA/hapten) and competitor immobilization of the biotinylated conjugate (AB-ELISA) to avidin (avidin/hapten). The best results were achieved with the RAb 212 antibodies in RSA/ST-3 and avidin/ST-10 assembled variants. For the RSA/ST-3 system, an IC50 of 0.3 ng/mL and a detection limit of 0.02 ng/mL were measured. In case of avidin/ST-10 variant, IC50 was of 3.9 ng/mL and a detection limit of 0.57 ng/mL were obtained. The effect of solvent was tested as well as the stability of coated microtiter plates over four-month period. The cross-reactivity of the developed assays with other anabolic steroids was tested and high sensitivity towards 17α-methylated steroids was observed. RSA/ST-3 assay showed significant cross-reactivity with 17α-methyltestosterone (81.2%), oxymetholone (30.4%), methandienone (10.0%) and methyl dihydrotestosterone (7.7%). Similarly, in the avidin/ST-10 assay, 17α-methyltestosterone (34.5%), mestanolone (32.1%), oxymetholone (22.7%), methandienone (14.2%), 9-dehydromethyltestosterone (12.5%) and oxandrolone (1.2%) exhibited high cross-reactivity. The functionality of the developed systems was verified by the successful identification of a series of 17α-methylated anabolic steroids in a set of real samples including pharmaceutical preparations seized by the Police of the Czech Republic on the black market.
Assuntos
Ensaio de Imunoadsorção Enzimática , Medicina Legal , Estanozolol/química , Congêneres da Testosterona/análise , Animais , Calibragem , Bovinos , Soros Imunes , Metilação , Conformação Molecular , Coelhos , Albumina Sérica/química , EstereoisomerismoRESUMO
INTRODUCTION: The use of new psychoactive substances as drugs of abuse has dramatically increased over the last years. Hallucinogenic phenethylamines gained particular popularity as they have both stimulating and psychedelic effects. Although generally perceived as safe, these illicit drugs pose a serious health risk; they have been linked to cases of severe poisoning or even deaths. Therefore, simple, cost-effective and reliable methods are needed for rapid determination of abused hallucinogens. METHODS: For this purpose, two haptens derived from 2C-H were designed, synthesized and subsequently attached to a carrier protein. Polyclonal antibodies obtained from a rabbit immunized with one of the prepared immunogens were used for the development of two immunoassays. RESULTS: In this study, a lateral flow immunoassay (LFIA) and an enzyme linked immunosorbent assay (ELISA) for the detection of 2C-B and related hallucinogenic phenethylamines in urine were developed. The presented LFIA is primarily suitable for on-site monitoring as it is simple and can provide a visual evidence of 2C-B presence within a few minutes. Its reasonable sensitivity (LODLFIAâ¯=â¯15⯱â¯7â¯ngâ¯mL-1) allows detection of the drug presence in urine after acute exposure. For greater accuracy, highly sensitive ELISA (LODELISAâ¯=â¯6⯱â¯3â¯pgâ¯mL-1) is proposed for toxicological quantitative analyses of positive samples captured by the LFIA. DISCUSSION: The comparison of the ELISA with the well-established UHPLC-MS-MS method shows excellent agreement of results, which confirms good potential of the ELISA to be used for routine analyses of 2C-B and related hallucinogenic phenethylamines of both main sub-families.
Assuntos
Dimetoxifeniletilamina/análogos & derivados , Alucinógenos/urina , Drogas Ilícitas/urina , Imunoensaio/métodos , Detecção do Abuso de Substâncias/métodos , Dimetoxifeniletilamina/química , Dimetoxifeniletilamina/imunologia , Dimetoxifeniletilamina/urina , Feminino , Alucinógenos/química , Alucinógenos/imunologia , Haptenos/química , Haptenos/imunologia , Voluntários Saudáveis , Humanos , Drogas Ilícitas/química , Drogas Ilícitas/imunologia , Imunoensaio/economia , Masculino , Reprodutibilidade dos Testes , Detecção do Abuso de Substâncias/instrumentação , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/métodosRESUMO
Methandienone is a synthetic exogenous steroid which, like other anabolic steroids, is strictly regulated in many countries. In recent years, increasing numbers have been detected of illegal additions into dietary supplements of methandienone and other anabolic androgenic steroids (AAS). In this work, a competitive indirect enzyme-linked immunosorbent assay (ELISA) has been constructed for the detection of methandienone using an antiserum against methandienone. Under optimal experimental conditions, the ELISA achieved a limit of detection of 0.04 ± 0.01 µg.g-1. The obtained intra- and inter-day coefficients of variation were less than 8%. The developed ELISA was applied in the analysis of real dietary supplement samples. To minimise the effect of the sample matrix, the sample extracts were simply diluted before addition into the immunoassay. The achieved recovery values were around 100%. Results obtained from the ELISA correlated well, both in terms of accuracy and precision, with those obtained by UHPLC-MS/MS (reference method). The presented ELISA could be successfully applied for the simple screening of dietary supplements.
Assuntos
Suplementos Nutricionais/análise , Ensaio de Imunoadsorção Enzimática , Metandrostenolona/análiseRESUMO
Tryptamines are a group of hallucinogenic drugs whose detection in body fluids could be simplified by immunochemical assay kits. Antibodies for these assays are obtained by the immunization of laboratory animals with conjugates of a hapten similar to the target analyte and a suitable protein. Therefore we synthesized novel haptens derived from tryptamine-based drugs, with N,N-dimethyltryptamine (DMT), 5-methoxy-N,N-dimethyltryptamine (5-MeO-DMT) and N,N-diisopropyltryptamine (DiPT) selected as the target analytes. Their structures were modified with a short linker ended with a carboxylic group. The haptens were conjugated with bovine serum albumin (BSA) and rabbits were immunized with the conjugates. The obtained polyclonal antibodies showed good reactivity and the LOD of the constructed ELISAs was in the range 0.006-0.254 ng mL-1. Thus, they are suitable for the development of immunochemical assay kits.
RESUMO
In recent years, the use of synthetic cannabinoids (SCs) as drugs of abuse has greatly increased. SCs are associated with a risk of severe poisoning or even death. Therefore, more rapid, cost effective and reliable methods are needed, especially for the screening of drivers after traffic accidents and for detailed toxicological analysis in forensic laboratories. In this study, we developed a lateral flow immunoassay (LFIA) and an enzyme linked immunosorbent assay (ELISA) for the detection of JWH-200 in oral fluids. For this purpose a new hapten was prepared using a ten-step synthetic route. The developed immuno methods are based on antibodies obtained from rabbit immunized with synthesized hapten conjugated to carrier protein. The proposed methods are highly sensitive (LODLFIAâ¯=â¯0.08⯱â¯0.04â¯ngâ¯mL-1; LODELISAâ¯=â¯0.04⯱â¯0.02â¯ngâ¯mL-1). They were applied to the quantification of JHW-200 in spiked oral fluids. The recoveries ranged from 82 to 134% for both methods. The results correlated excellently with results obtained using UHPLC-MS/MS (R2LFIAâ¯=â¯0.99; R2ELISAâ¯=â¯0.99). Our developed methods could be an important tool for analyses of JWH-200 in human oral fluids. The one-step LFIA is particularly suitable for roadside and on-site monitoring due to the rapid qualitative results it delivers, while the ELISA is especially useful for laboratory quantitative analyses of positive samples captured by LFIA.
RESUMO
Avidin-biotin technology was used for the implementation of an enzyme-linked immunosorbent assay (AB-ELISA) as a sensitive method for the detection of anabolic androgenic steroids (AAS) present in dietary supplements. Using click chemistry, novel haptens (linker-optimized biotinylated nandrolone (NT) and testosterone (T) at positions C-3 and C-17, respectively) were designed and synthesized to be then applied as four different immobilized competitors in a proposed set of four indirect competitive AB-ELISAs. Four rabbit polyclonal antibodies of various specificities were prepared using four different immunogens synthesized from C-3 and C-17 carboxymethyloxime and hemisuccinate derivatives of NT and T, respectively. Assembled AB-ELISAs were characterized to establish method parameters such as a half-maximum inhibition concentration (0.18-12.99 ng/mL), limit of detection (0.004-0.032 ng/mL) and linear working range (the best with 0.02-1.38 ng/mL). The stability of the set simulating storage in different conditions was demonstrated. Cross reactivity (CR) was tested for 59 steroids including both endogenous and synthetic analogues in four assembled AB-systems. The focus was placed on the practical use of the method in detection of various AAS in 49 samples of counterfeit dietary supplements. The concordance between ultra high performance liquid chromatography-mass spectrometry (UHPLC-MS) and the CR corrected data from AB-ELISA indicated the potential of this method even to quantification of T propionate, NT phenyl propionate, and NT decanoate in such a complex matter. Copyright © 2016 John Wiley & Sons, Ltd.
Assuntos
Anabolizantes/análise , Suplementos Nutricionais/análise , Ensaio de Imunoadsorção Enzimática/métodos , Nandrolona/análise , Testosterona/análise , Animais , Avidina/química , Biotina/química , Limite de Detecção , CoelhosRESUMO
A simple and rapid immunochromatographic assay for a sensitive and inexpensive monitoring of methiocarb in surface water was developed using a binding inhibition format on a membrane strip. In the assay, detection reagent consisted of anti-methiocarb antibody and colloidal carbon-labelled secondary antibody. Methiocarb-ovalbumin conjugate was immobilized in a test line of the strip as a capture reagent. Colour intensity of the test line in methiocarb-positive assay was visually distinguishable from that of negative sample within 10min. The optimized semi-quantitative method provided a visual detection limit of 0.5ngmL(-1). Cross-reactions with other carbamate pesticides were not found (<1%). Only a negligible matrix effect of surface water was recognized. In parallel analyses of spiked water samples, the assay results were in a good agreement with those of ELISA. The stability test indicated the strips could be used at least 2 months without change in performance. All characteristics of the visually evaluated assay mentioned above were verified by instrumental quantification of colour intensity in test lines. The developed immunochromatographic assay offers potential as a useful on-site screening tool for environmental analysis.