Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Front Immunol ; 15: 1347871, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38469305

RESUMO

The antibody- FcγRIIIa interaction triggers key immunological responses such as antibody dependent cellular cytotoxicity (ADCC), making it highly important for therapeutic mAbs. Due to the direct glycan-glycan interaction with FcγRIIIa receptor, differences in antibody glycosylation can drastically influence the binding affinity. Understanding the differential binding of mAb glycoforms is a very important, yet challenging task due to the co-existence of multiple glycoforms in a sample. Affinity liquid chromatography (AC) and affinity capillary electrophoresis (ACE) hyphenated with mass spectrometry (MS) can provide glycoform-resolved affinity profiles of proteins based on their differences in either dissociation (AC) or equilibrium (ACE) constants. To cross-validate the affinity ranking provided by these complementary novel approaches, both techniques were benchmarked using the same FcγRIIIa constructs. Both approaches were able to assess the mAb - FcγRIIIa interaction in a glycoform selective manner and showed a clear increase in binding for fully versus hemi-fucosylated mAbs. Also, other features, such as increasing affinity with elevated galactosylation or the binding affinity for high mannose glycoforms were consistent. We further applied these approaches to assess the binding towards the F158 allotype of FcγRIIIa, which was not reported before. The FcγRIIIa F158 allotype showed a very similar profile compared to the V158 receptor with the strongest increase in binding due to afucosylation and only a slight increase in binding with additional galactosylation. Both techniques showed a decrease of the binding affinity for high mannose glycoforms for FcγRIIIa F158 compared to the V158 variant. Overall, both approaches provided very comparable results in line with orthogonal methods proving the capabilities of separation-based affinity approaches to study FcγR binding of antibody glycoforms.


Assuntos
Imunoglobulina G , Receptores de IgG , Receptores de IgG/metabolismo , Imunoglobulina G/metabolismo , Manose , Benchmarking , Anticorpos Monoclonais/metabolismo , Polissacarídeos/metabolismo , Espectrometria de Massas
2.
MAbs ; 15(1): 2175312, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36799476

RESUMO

The development of increasingly complex antibody formats, such as bispecifics, can lead to the formation of increasingly complex high- and low-molecular-weight by-products. Here, we focus on the characterization of high molecular weight species (HMWs) representing the highest complexity of size variants. Standard methods used for product release, such as size exclusion chromatography (SEC), can separate HMW by-products from the main product, but cannot distinguish smaller changes in mass. Here, for the identification of the diverse and complex HMW variants of a trivalent bispecific CrossMAb antibody, offline fractionation, as well as production of HMW by-products combined with comprehensive analytical testing, was applied. Furthermore, HMW variants were analyzed regarding their chemical binding nature and tested in functional assays regarding changes in potency of the variants. Changes in potency were explained by detailed characterization using mass photometry, SDS-PAGE analysis, native mass spectrometry (MS) coupled to SEC and bottom-up proteomics. We identified a major portion of the HMW by-products to be non-covalently linked, leading to dissociation and changes in activity. We also identified and localized high heterogeneity of a by-product of concern and applied a CD3 affinity column coupled to native MS to annotate unexpected by-products. We present here a multi-method approach for the characterization of complex HMW by-products. A better understanding of these by-products is beneficial to guide analytical method development and proper specification setting for therapeutic bispecific antibodies to ensure constant efficacy and patient safety of the product through the assessment of by-products.


Assuntos
Anticorpos Biespecíficos , Humanos , Anticorpos Biespecíficos/química , Peso Molecular , Espectrometria de Massas/métodos , Cromatografia em Gel
3.
Anal Chem ; 95(4): 2260-2268, 2023 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-36638115

RESUMO

T-cell engaging bispecific antibodies (TCBs) targeting CD3 and tumor-specific antigens are very promising therapeutic modalities. Since CD3 binding is crucial for the potency of TCBs, understanding the functional impact of CD3 antigen-binding fragment modifications is of utmost importance for defining critical quality attributes (CQA). The current CQA assessment strategy requires the integration of structure-based physicochemical separation and functional cell-based potency assays. However, this strategy is tedious, and coexisting proteoforms with potentially different functionalities may not be individually assessed. This increases the degree of ambiguities for defining meaningful CQAs, particularly for complex bispecific antibody formats such as TCBs. Here, we report for the first time a proof-of-concept study to separate and identify critically modified proteoforms of TCBs using functional CD3 target affinity chromatography (AC) coupled with online mass spectrometry (MS). Our method enabled functional distinction of relevant deamidated and glycosylated proteoforms and the simultaneous assessment of product-related variants such as TCB mispairings. For example, CD3 AC-MS allowed us to separate TCB mispairings with increased CD3 binding (i.e., knob-knob homodimers) within the bound fraction. The functional separation of proteoforms was validated using an established workflow for CQA identification based on thoroughly characterized ion-exchange fractions of a 2+1 TCB. In addition, the new method facilitated the criticality assessment of post-translational modifications in stress studies and structural variants in early stage clone selection. CD3 AC-MS has high impact for streamlining the integration of functional and structural characterizations of the large landscape of therapeutic CD3 targeting TCBs from early stage research to late stage characterization.


Assuntos
Anticorpos Biespecíficos , Linfócitos T , Linfócitos T/metabolismo , Espectrometria de Massas , Cromatografia de Afinidade , Glicosilação , Processamento de Proteína Pós-Traducional , Anticorpos Biespecíficos/metabolismo , Complexo CD3/metabolismo
4.
Anal Chem ; 93(45): 15133-15141, 2021 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-34739220

RESUMO

Monoclonal antibody (mAb) pharmaceuticals consist of a plethora of different proteoforms with different functional characteristics, including pharmacokinetics and pharmacodynamics, requiring their individual assessment. Current binding techniques do not distinguish between coexisting proteoforms requiring tedious production of enriched proteoforms. Here, we have developed an approach based on mobility shift-affinity capillary electrophoresis-mass spectrometry (ACE-MS), which permitted us to determine the binding of coexisting mAb proteoforms to Fc receptors (FcRs). For high-sensitivity MS analysis, we used a sheathless interface providing adequate mAb sensitivity allowing functional characterization of mAbs with a high sensitivity and dynamic range. As a model system, we focused on the interaction with the neonatal FcR (FcRn), which determines the half-life of mAbs. Depending on the oxidation status, proteoforms exhibited different electrophoretic mobility shifts in the presence of FcRn, which could be used to determine their affinity. We confirmed the decrease of the FcRn affinity with antibody oxidation and observed a minor glycosylation effect, with higher affinities for galactosylated glycoforms. Next to relative binding, the approach permits the determination of individual KD values in solution resulting in values of 422 and 139 nM for double-oxidized and non-oxidized variants. Hyphenation with native MS provides unique capabilities for simultaneous heterogeneity assessment for mAbs, FcRn, and complexes formed. The latter provides information on binding stoichiometry revealing 1:1 and 1:2 for antibody/FcRn complexes. The use of differently engineered Fc-only constructs allowed distinguishing between symmetric and asymmetric binding. The approach opens up unique possibilities for proteoform-resolved antibody binding studies to FcRn and can be extended to other FcRs and protein interactions.


Assuntos
Eletroforese Capilar , Receptores Fc , Anticorpos Monoclonais/metabolismo , Glicosilação , Antígenos de Histocompatibilidade Classe I/metabolismo , Humanos , Recém-Nascido , Espectrometria de Massas , Receptores Fc/metabolismo
5.
J Am Soc Mass Spectrom ; 32(8): 2062-2071, 2021 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-33687195

RESUMO

The aim of this study was to characterize the product variants of a therapeutic T-cell bispecific humanized monoclonal antibody (TCB Mab, ∼200 kDa, asymmetric) and to develop an online cation-exchange chromatography native electrospray mass spectrometry method (CEC-UV-MS) for direct TCB Mab charge variant monitoring during bioprocess and formulation development. For the identification and functional evaluation of the diverse and complex TCB Mab charge variants, offline fractionation combined with comprehensive analytical testing was applied. The offline fractionation of abundant product variant peaks enabled identification of coeluting acid charge variants such as asparagine deamidation, primary and secondary Fab glycosylation (with and without sialic acid), and the presence of O-glycosylation in the G4S-linker region. Consequently, a new nonconsensus N-glycosylation motif (N-338-FG) in the heavy chain CDR region was discovered. Functional evaluation by cell-based potency testing demonstrated a clear and negative impact of both asparagine deamidations, whereas the O-glycosylation did not affect the TCB Mab biological activity. We established an online native CEC-UV-MS method, with an ammonium acetate buffer and pH gradient, to directly monitor the TCB Mab charge variants. All abundant chemical degradations and post-translational amino acid modifications already identified by offline fraction experiments and liquid chromatography mass spectrometry peptide mapping could also be monitored by the online CEC-UV-MS method. The herein reported online native CEC-UV-MS methodology represents a complementary or even alternative approach for multiattribute monitoring of biologics, offering multiple benefits, including increased throughput and reduced sample handling and intact protein information in the near-native state.


Assuntos
Anticorpos Monoclonais/análise , Anticorpos Monoclonais/química , Cromatografia por Troca Iônica/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Anticorpos Monoclonais/metabolismo , Cátions , Regiões Determinantes de Complementaridade , Glicosilação , Fragmentos Fab das Imunoglobulinas/análise , Fragmentos Fab das Imunoglobulinas/química , Fragmentos Fab das Imunoglobulinas/metabolismo , Mapeamento de Peptídeos/métodos , Raios Ultravioleta
6.
Anal Chem ; 92(14): 9476-9481, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32578997

RESUMO

Recombinant human erythropoietin (rhEPO) is an important biopharmaceutical for which glycosylation is a critical quality attribute. Therefore, robust analytical methods are needed for the in-depth characterization of rhEPO glycosylation. Currently, the protease GluC is widely established for the site-specific glycosylation analysis of rhEPO. However, this enzyme shows disadvantages, such as its specificity and the characteristics of the resulting (glyco)peptides. The use of trypsin, the gold standard protease in proteomics, as the sole protease for rhEPO is compromised, as no natural tryptic cleavage site is located between the glycosylation sites Asn24 and Asn38. Here, cysteine aminoethylation using 2-bromoethylamine was applied as an alternative alkylation strategy to introduce artificial tryptic cleavage sites at Cys29 and Cys33 in rhEPO. The (glyco)peptides resulting from a subsequent digestion using trypsin were analyzed by reverse-phase liquid chromatography-mass spectrometry. The new trypsin-based workflow was easily implemented by adapting the alkylation step in a conventional workflow and was directly compared to an established approach using GluC. The new method shows an improved specificity, a significantly reduced chromatogram complexity, allows for shorter analysis times, and simplifies data evaluation. Furthermore, the method allows for the monitoring of additional attributes, such as oxidation and deamidation at specific sites in parallel to the site-specific glycosylation analysis of rhEPO.


Assuntos
Cisteína/química , Eritropoetina/química , Proteínas Recombinantes/química , Tripsina/química , Glicosilação , Humanos
7.
Sci Rep ; 7(1): 5324, 2017 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-28706253

RESUMO

Erythropoietin (EPO) is a heavily glycosylated hormone whose recombinant forms are used for treatment of anaemia. EPO glycosylation is important for its pharmacological properties. An analytical workflow, which can determine EPO glycosylation in an accurate and high-throughput fashion from cell culture supernatant (CCS) in approximately 24 h, offers the possibility to follow changes during production. To address this challenge, we present a complete workflow consisting of protein purification, glycan release, sialic acid derivatization, solid phase extraction, matrix-assisted laser desorption/ionization - mass spectrometry (MALDI-MS) analysis and MassyTools data processing. EPO purification from CCS by anti-EPO antibody coupled Sepharose beads yielded excellent purity with acceptable recovery and was free of glycoform bias. Glycosylation profiles obtained by MALDI-MS were highly comparable to those obtained with an established capillary gel electrophoresis-laser induced fluorescence method. Our method delivers accurate results for the analysis of changes of important glycosylation parameters, such as sialylation and number of N-acetyllactosamine units, for the time course of a fermentation. We could resolve differences in glycosylation between several CCS samples.


Assuntos
Cromatografia de Afinidade/métodos , Meios de Cultura Livres de Soro/química , Eritropoetina/isolamento & purificação , Eritropoetina/metabolismo , Glicosilação , Animais , Células CHO , Cricetulus , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
8.
MAbs ; 8(2): 331-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26655595

RESUMO

High-molecular weight aggregates such as antibody dimers and other side products derived from incorrect light or heavy chain association typically represent critical product-related impurities for bispecific antibody formats. In this study, an approach employing ultra-pressure liquid chromatography size-exclusion separation combined with native electrospray ionization mass spectrometry for the simultaneous formation, identification and quantification of size variants in recombinant antibodies was developed. Samples exposed to storage and elevated temperature(s) enabled the identification of various bispecific antibody size variants. This test system hence allowed us to study the variants formed during formulation and bio-process development, and can thus be transferred to quality control units for routine in-process control and release analytics. In addition, native SEC-UV/MS not only facilitates the detailed analysis of low-abundant and non-covalent size variants during process characterization/validation studies, but is also essential for the SEC-UV method validation prior to admission to the market.


Assuntos
Anticorpos Biespecíficos/química , Cromatografia em Gel , Agregados Proteicos , Anticorpos Biespecíficos/análise
9.
MAbs ; 7(5): 891-900, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26000623

RESUMO

Oxidation of methionine (Met) residues is one of several chemical degradation pathways for recombinant IgG1 antibodies. Studies using several methodologies have indicated that Met oxidation in the constant IgG1 domains affects in vitro interaction with human neonatal Fc (huFcRn) receptor, which is important for antibody half-life. Here, a completely new approach to investigating the effect of oxidative stress conditions has been applied. Quantitative ultra-performance liquid chromatography mass spectrometry (MS) peptide mapping, classical surface plasmon resonance and the recently developed FcRn column chromatography were combined with the new fast-growing approach of native MS as a near native state protein complex analysis in solution. Optimized mass spectrometric voltage and pressure conditions were applied to stabilize antibody/huFcRn receptor complexes in the gas phase for subsequent native MS experiments with oxidized IgG1 material. This approach demonstrated a linear correlation between quantitative native MS and IgG-FcRn functional analysis. In our study, oxidation of the heavy chain Met-265 resulted in a stepwise reduction of mAb3/huFcRn receptor complex formation. Remarkably, a quantitative effect of the heavy chain Met-265 oxidation on relative binding capacity was only detected for doubly oxidized IgG1, whereas IgG1 with only one oxidized heavy chain Met-265 was not found to significantly affect IgG1 binding to huFcRn. Thus, mono-oxidized IgG1 heavy chain Met-265 most likely does not represent a critical quality attribute for pharmacokinetics.


Assuntos
Antígenos de Histocompatibilidade Classe I/metabolismo , Imunoglobulina G/metabolismo , Espectrometria de Massas/métodos , Oxirredução , Receptores Fc/metabolismo , Anticorpos Monoclonais/química , Anticorpos Monoclonais/metabolismo , Cromatografia Líquida , Humanos , Imunoglobulina G/química , Mapeamento de Peptídeos , Ressonância de Plasmônio de Superfície
10.
MAbs ; 7(4): 732-42, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25996192

RESUMO

To monitor the Fc glycosylation of therapeutic immunoglobulin G in bioprocess development, product characterization and release analytics, reliable techniques for glycosylation analysis are needed. Several analytical methods are suitable for this application. We recently presented results comparing detection methods for glycan analysis that are separation-based, but did not include mass spectrometry (MS). In the study reported here, we comprehensively compared MS-based methods for Fc glycosylation profiling of an IgG biopharmaceutical. A therapeutic antibody reference material was analyzed 6-fold on 2 different days, and the methods investigated were compared with respect to precision, accuracy, throughput and analysis time. Emphasis was put on the detection and quantitation of sialic acid-containing glycans. Eleven MS methods were compared to hydrophilic interaction liquid chromatography of 2-aminobenzamide labeled glycans with fluorescence detection, which served as a reference method and was also used in the first part of the study. The methods compared include electrospray MS of the heavy chain and Fc part after limited digestion, liquid chromatography MS of a tryptic digest, porous graphitized carbon chromatography MS of released glycans, electrospray MS of glycopeptides, as well as matrix assisted laser desorption ionization MS of glycans and glycopeptides. Most methods showed excellent precision and accuracy. Some differences were observed with regard to the detection and quantitation of low abundant glycan species like the sialylated glycans and the amount of artefacts due to in-source decay.


Assuntos
Anticorpos Monoclonais/química , Fragmentos Fc das Imunoglobulinas/química , Imunoglobulina G/química , Ácidos Siálicos/análise , Animais , Células CHO , Cricetinae , Cricetulus , Glicosilação , Humanos , Proteínas Recombinantes/química
11.
MAbs ; 7(1): 167-79, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25524468

RESUMO

Immunoglobulin G (IgG) crystallizable fragment (Fc) glycosylation is crucial for antibody effector functions, such as antibody-dependent cell-mediated cytotoxicity, and for their pharmacokinetic and pharmacodynamics behavior. To monitor the Fc-glycosylation in bioprocess development, as well as product characterization and release analytics, reliable techniques for glycosylation analysis are needed. A wide range of analytical methods has found its way into these applications. In this study, a comprehensive comparison was performed of separation-based methods for Fc-glycosylation profiling of an IgG biopharmaceutical. A therapeutic antibody reference material was analyzed 6-fold on 2 different days, and the methods were compared for precision, accuracy, throughput and other features; special emphasis was placed on the detection of sialic acid-containing glycans. Seven, non-mass spectrometric methods were compared; the methods utilized liquid chromatography-based separation of fluorescent-labeled glycans, capillary electrophoresis-based separation of fluorescent-labeled glycans, or high-performance anion exchange chromatography with pulsed amperometric detection. Hydrophilic interaction liquid chromatography-ultra high performance liquid chromatography of 2-aminobenzamide (2-AB)-labeled glycans was used as a reference method. All of the methods showed excellent precision and accuracy; some differences were observed, particularly with regard to the detection and quantitation of minor glycan species, such as sialylated glycans.


Assuntos
Anticorpos Monoclonais/química , Fragmentos Fc das Imunoglobulinas/química , Animais , Células CHO , Cromatografia Líquida de Alta Pressão , Cricetinae , Cricetulus , Glicosilação , Espectrometria de Massas
12.
MAbs ; 6(2): 327-39, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24441081

RESUMO

Modifications like asparagine deamidation, aspartate isomerization, methionine oxidation, and lysine glycation are typical degradations for recombinant antibodies. For the identification and functional evaluation of antibody critical quality attributes (CQAs) derived from chemical modifications in the complementary-determining regions (CDRs) and the conserved regions, an approach employing specific stress conditions, elevated temperatures, pH, oxidizing agents, and forced glycation with glucose incubation, was applied. The application of the specific stress conditions combined with ion exchange chromatography, proteolytic peptide mapping, quantitative liquid chromatography mass spectrometry, and functional evaluation by surface plasmon resonance analysis was adequate to identify and functionally assess chemical modification sites in the CDRs of a recombinant IgG1. LC-Met-4, LC-Asn-30/31, LC-Asn-92, HC-Met-100c, and HC Lys-33 were identified as potential CQAs. However, none of the assessed degradation products led to a complete loss of functionality if only one light or heavy chain of the native antibody was affected.


Assuntos
Regiões Determinantes de Complementaridade/metabolismo , Produtos Finais de Glicação Avançada/metabolismo , Imunoglobulina G/metabolismo , Mapeamento de Peptídeos/métodos , Proteínas Recombinantes/metabolismo , Cromatografia por Troca Iônica , Cromatografia Líquida , Temperatura Alta , Humanos , Concentração de Íons de Hidrogênio , Espectrometria de Massas , Estresse Oxidativo , Processamento de Proteína Pós-Traducional , Proteólise , Ressonância de Plasmônio de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA