Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Exp Biol ; 226(17)2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37599599

RESUMO

Captive housed non-human primates, specifically great apes such as chimpanzees (Pan troglodytes) are frequently reported to have died from or are diagnosed with potentially fatal heart conditions that require the monitoring of physiological signals such as electrocardiogram (ECG) or respiratory rate. ECG screening must be conducted after applying full anaesthesia, causing potential physical and emotional stress as well as risk for the animal. Here, we present an electronic system that simultaneously measures the ECG and the electrical bioimpedance for the early detection of abnormal cardiovascular activity. Modified gloves whose fingers are equipped with electrodes enable the caregiver to obtain three cardiovascular signals (ECG, pulse rate and respiratory rate) by placing the fingertips on specific parts of the non-human primate without needing any prior physical preparations. Validation (ECG and bioimpedance) was performed both on humans and on captive housed chimpanzees, where all the signals of interest were correctly acquired.


Assuntos
Anestesia , Pan troglodytes , Animais , Humanos , Primatas , Eletrocardiografia/veterinária , Coração
2.
Sensors (Basel) ; 21(16)2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-34451047

RESUMO

A fully automatic, non-contact method for the assessment of the respiratory function is proposed using an RGB-D camera-based technology. The proposed algorithm relies on the depth channel of the camera to estimate the movements of the body's trunk during breathing. It solves in fixed-time complexity, O(1), as the acquisition relies on the mean depth value of the target regions only using the color channels to automatically locate them. This simplicity allows the extraction of real-time values of the respiration, as well as the synchronous assessment on multiple body parts. Two different experiments have been performed: a first one conducted on 10 users in a single region and with a fixed breathing frequency, and a second one conducted on 20 users considering a simultaneous acquisition in two regions. The breath rate has then been computed and compared with a reference measurement. The results show a non-statistically significant bias of 0.11 breaths/min and 96% limits of agreement of -2.21/2.34 breaths/min regarding the breath-by-breath assessment. The overall real-time assessment shows a RMSE of 0.21 breaths/min. We have shown that this method is suitable for applications where respiration needs to be monitored in non-ambulatory and static environments.


Assuntos
Respiração , Taxa Respiratória , Algoritmos , Monitorização Fisiológica , Sistema Respiratório
3.
Waste Manag ; 34(4): 738-46, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24472716

RESUMO

Monitoring of the moisture and temperature of composting process is a key factor to obtain a quality product beyond the quality of raw materials. Current methodologies for monitoring these two parameters are time consuming for workers, sometimes not sufficiently reliable to help decision-making and thus are ignored in some cases. This article describes an advance on monitoring of composting process through a Wireless Sensor Network (WSN) that allows measurement of temperature and moisture in real time in multiple points of the composting material, the Compo-ball system. To implement such measurement capabilities on-line, a WSN composed of multiple sensor nodes was designed and implemented to provide the staff with an efficient monitoring composting management tool. After framing the problem, the objectives and characteristics of the WSN are briefly discussed and a short description of the hardware and software of the network's components are presented. Presentation and discussion of practical issues and results obtained with the WSN during a demonstration stage that took place in several composting sites concludes the paper.


Assuntos
Solo/química , Gerenciamento de Resíduos , Tecnologia sem Fio , Temperatura , Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA