Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Ceska Slov Farm ; 71(2): 67-77, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35728971

RESUMO

The aim of the present study is the development and validation of a simple method based on capillary zone electrophoresis coupled with UV detection for simultaneous determination of tramadol and paracetamol in pharmaceutical and biological samples. The background electrolyte was composed of 50 mM ammonium carbonate, which is a type of a non-conventional electrolyte system. The developed method was characterized by suitable validation parameters, such as linearity (coefficient of determination r2 0,995), selectivity or the limit of detection at the level of 0.25 - 0.5 μg/ml. Acceptable values of accuracy and precision were obtained, which were in good agreement with the recommended validation guidelines for analysis of pharmaceutical and biological samples. Detection was performed at a wavelength of 200 nm. The developed method was successfully applied to determine tramadol and paracetamol in various dosage forms and in urine biological samples. Achieved results indicate a potential of the method to be integrated in the common quality control processes of drugs and/or in bioanalysis.


Assuntos
Tramadol , Acetaminofen , Eletroforese Capilar/métodos , Preparações Farmacêuticas , Tramadol/análise
2.
Biomedicines ; 9(10)2021 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-34680605

RESUMO

A capillary electrophoresis-tandem mass spectrometry method with a multisegment injection and an in-capillary field-enhanced sample stacking for determination of therapeutic peptide triptorelin in pharmaceutical and biological matrices was developed. The CE separation conditions were optimized in order to obtain maximal separation efficiency, analytical signal intensity and stability, and minimal adsorption of the analyzed peptide onto the capillary wall (1 M formic acid-HFo, pH 1.88). The implementation of the field-enhanced sample injection into CE improved the value of limit of detection 50 times while the multisegment injection increased the sample throughput three times in comparison to a conventional CE approach. The proposed method was characterized by favorable performance parameters, such as linearity (r2 ≥ 0.99), limit of detection (5 ng mL-1 in water matrix, 25 ng mL-1 in plasma matrix), precision (relative standard deviation, 1.5-9.4% for intraday and 2.3-11.9% for interday reproducibility), or accuracy (relative errors in the range of 80-109%). The FDA-validated method was successfully applied to the analysis of triptorelin in the commercial drug Diphereline® 0.1 mg (powder for injection) and in spiked human plasma samples. Favorable performance parameters along with proven application potentialities indicate the usefulness of the proposed method for its routine use in drug quality control laboratories and for clinical analysis, such as determination of triptorelin levels in plasma (for pharmacokinetic study).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA