1.
Anal Chim Acta ; 1304: 342556, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38637040

RESUMO

BACKGROUND: The on-site and simultaneous determination of anionic nitrite (NO2-) and nitrate (NO3-), and cationic ammonium (NH4+), in industrial and natural waters, presents a significant analytical challenge. Toward this end, herein a 3D-printed micro-reactor with an integrated heater chip was designed and optimised for the post-column colorimetric detection of NH4+ using a modified Berthelot reaction. The system was integrated within a portable and field deployable ion chromatograph (Aquamonitrix) designed to separate and detect NO2- and NO3-, but here enabled with dual LED-based absorbance detectors, with the aim to provide the first system capable of simultaneous determination of both anions and NH4+ in industrial and natural waters. RESULTS: Incorporating a 0.750 mm I.D. 3D-printed serpentine-based microchannel for sample-reagent mixing and heating, the resultant micro-reactor had a total reactor channel length of 1.26 m, which provided for a reaction time of 1.42 min based upon a total flow rate of 0.27 mL min-1, within a 40 mm2 printed area. The colorimetric reaction was performed within the micro-reactor, which was then coupled to a dedicated 660 nm LED-based absorbance detector. By rapidly delivering a reactor temperature of 70 °C in just 40 s, the optimal conditions to improve reaction kinetics were achieved to provide for limits of detection of 0.1 mg L-1 for NH4+, based upon an injection volume of just 10 µL. Linearity for NH4+ was observed over the range 0-50 mg L-1, n = 3, R2 = 0.9987. The reactor was found to deliver excellent reproducibility when included as a post-column reactor within the Aquamonitrix analyser, with an overall relative standard deviation below 1.2 % for peak height and 0.3 % for peak residence time, based upon 6 repeat injections. SIGNIFICANCE: The printed post-column reactor assembly was integrated into a commercial portable ion chromatograph developed for the separation and detection of NO2- and NO3-, thus providing a fully automated system for the remote and simultaneous analysis of NO2-, NO3-, and NH4+ in natural and industrial waters. The fully automated system was deployed externally within a greenhouse facility to demonstrate this capability.

2.
J Chromatogr A ; 1709: 464382, 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37722175

RESUMO

A novel approach for multi-wavelength ultraviolet (UV) absorbance detection has been introduced employing a single board computer (SBC) with a field programmable gate array (FPGA), Red Pitaya SBC, to generate separated micro pulses for three deep-ultraviolet light-emitting diodes (DUV-LEDs), λmax = 235, 250, and 280 nm, along with data acquisition and processing via a custom-made program. The pulse set generation and data acquisition were synchronized using the SBC. The outputs of the three pulsing DUV-LEDs were combined and transmitted to the flow cell via a solarisation resistant trifurcated optical fiber (OF). An ultra-fast responding photodiode was connected to the optical-fiber-compatible flow cell to record the intensity of the DUV pulses. Upper limit of detector linearity (A95 %) was found to be 1917 mAU, 2189 mAU, and 1768 mAU at 235 nm, 250 nm, and 280 nm, respectively, with stray light ≤0.9 %. In addition, the effective path length (Leff) was estimated to be ≥98.0 % of the length of the used flow cell (50 mm). The new pulsed multi-LEDs absorbance detector (PMLAD) has been successfully coupled with a standard liquid chromatograph and utilized for the analysis of pharmaceuticals. Paracetamol, caffeine, and aspirin were simultaneously determined at 250, 280, and 235 nm, respectively, using the PMLAD. The absorbance ratios between the different wavelengths were applied to further confirm the identity of the studied compounds. Excellent linearity was achieved over a range of 0.1-3.2 µg/mL for paracetamol, 0.4-6.4 µg/mL for caffeine, and 0.8-12.8 µg/mL for aspirin with a regression correlation coefficient (r2) ≥ 0.99996. The quantitation limits (LOQs) were 0.10 µg/mL, 0.38 µg/mL, and 0.66 µg/mL for paracetamol, caffeine, and aspirin, respectively.


Assuntos
Cafeína , Raios Ultravioleta , Acetaminofen , Cromatografia Líquida , Aspirina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA