Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Zhongguo Gu Shang ; 37(1): 81-5, 2024 Jan 25.
Artigo em Chinês | MEDLINE | ID: mdl-38286456

RESUMO

OBJECTIVE: To investigate the feasibility of mimics software in analyzing a new type of complex anterior cervical fixation -- anterior transpedicular screw fixation+zero notch internal fixation. METHODS: From January 2021 to September 2022, 50 normal pedestrians who underwent cervical spine CT scanning were selected for C1-C7 segment scanning, including 27 males and 23 females, aged from 25 to 65 years old with an average of (46.0 ± 9.0) years old. The dicom format is exported and engraved into the CD, and use the mimics software to perform 3D reconstruction of each segment. A simulated screw is placed on the image according to the critical value of zero notch screw (head and tail angle 44°, internal angle 29°). The position of zero notch screw in each segment is observed to determine the feasibility of anterior transpedicular screw fixation plus zero notch internal fixation. RESULTS: For the upper zero notch screws the three-dimensional images of the cervical spine across all 50 subjects within the C3-C7 segments demonstrated safe position, with no instances of intersection with ATPS. For the lower zero notch screw, in C3-C4 and C4-C5, 4 out of 50 subjects are in the safe position in the three-dimensional images of cervical vertebrae, and 46 cases could achieve secure screw placement when the maximum caudal angle is(32.3±1.9) ° and (36.1±2.2) °, respectively. In C5-C6 and C6-C7 segments, no lower zero notch screws intersected with ATPS, and all screws are in safe positions. CONCLUSION: Lower cervical anterior pedicle screw fixation plus zero notch internal fixation can achieve successful nail placement through the selected entry point and position.


Assuntos
Parafusos Pediculares , Tomografia Computadorizada por Raios X , Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estudos de Viabilidade , Tomografia Computadorizada por Raios X/métodos , Fixação Interna de Fraturas , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Software
2.
BMC Musculoskelet Disord ; 24(1): 905, 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-37990231

RESUMO

OBJECTIVE: This study aims to investigate the feasibility of the anterior transpedicular root screw (ATPRS) intervertebral fusion system for the cervical spine and provide a basis for the design of the ATPRS intervertebral fusion system. METHODS: A total of 60 healthy adult cervical spine CT images examined from our hospital were selected, including 30 males and 30 females, with an average age of 39.6 ± 4.8 years. The image data was imported into Mimics 21.0 software in DICOM format for 3D model reconstruction. Simulated screw insertion was performed on both sides of the midline of the intervertebral space. The entry point (P1) was determined when the upper and lower screw paths did not overlap. When the screw was tangent to the medial edge of the Luschka joint, the insertion point was determined as the entry point (P2). Measurements were taken and recorded for the following parameters: distance from the screw entry point to the midline of the intervertebral space (DPM), the simulated screw length, inclination angle, cranial/caudal tilted angle, the anterior-posterior (AP) and mediolateral (ML) diameters of the cervical intervertebral space, the heights of the anterior, middle, and posterior edges of the cervical intervertebral space, and the curvature diameter of the lower end plate of the cervical vertebral body. Statistical analysis was performed on the measurement results. RESULTS: The screw entry area (P1P2) showed an increasing trend from C3-C7 in both male (2.92-6.08 mm) and female (2.32-5.12 mm) groups. There were statistical differences between men and women at the same level (P < 0.05). The average screw length of men and women was greater than 20 mm, and the upper and lower screw lengths showed an increasing trend from C3 to C7. In the area where screws could be inserted, the range of screw inclination was as follows: male group upper screw (47.73-66.76°), lower screw (48.05-65.35°); female group upper screw (49.15-65.66°) and lower screw (49.42-63.29°); The range of cranial/caudal tilted angle of the screw was as follows: male group upper screw (32.06-39.56°), lower screw (29.12-36.95°); female group upper screw (30.97-38.92°) and lower screw (27.29-37.20°). The anterior-posterior diameter and mediolateral diameter of the cervical intervertebral space showed an increasing trend from C3 to C7 in both male and female groups. The middle height (MH) of the cervical intervertebral space was greater than the anterior edge height (AH) and posterior edge height (PD), with statistical differences (P < 0.05). CONCLUSIONS: Through the study of CT images of the cervical spine, it was determined that the ATPRS intervertebral fusion system has a feasible area for screw insertion in the cervical intervertebral space.


Assuntos
Parafusos Ósseos , Fusão Vertebral , Adulto , Humanos , Masculino , Feminino , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Tomografia Computadorizada por Raios X/métodos , Pescoço , Software , Fusão Vertebral/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA