Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Comput Methods Biomech Biomed Engin ; 26(9): 999-1007, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35929922

RESUMO

The paper introduces the concept of the rational design of a deployable humeral intramedullary nail plug based on a honeycomb structure used for the surgical treatment of humeral shaft fractures. The concept serves for to restore the axial alignment of bone fragments and to maintain stability via bone-nail friction and locking screws. The design nail plug was gained by optimisation process the Latin Hypercube Sampling Design algorithm and Multi-Objective Genetic Algorithm. It was shown that we can use statistical shape function combined by 3 D printing for designing of a new rationally designed implants.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Úmero , Humanos , Estudos de Viabilidade , Úmero/cirurgia , Fraturas do Úmero/cirurgia , Pinos Ortopédicos
2.
J Clin Neurosci ; 105: 45-50, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36084565

RESUMO

BACKGROUND: This study is focused on the opening technique of the cervical vertebrae during laminoplasty which serves to substantially reduce the most severe adverse effects of the simple resection of posterior vertebral elements. This computational study aims to clarify by an optimisation approach what shape and position upon the lamina the groove should have. METHODS: The computational model was developed in the computational software COMSOL Multiphysics 5.6a based on a computer tomography data obtained from the C4 vertebra. For finding the optimal minimum or maximum of a function (surface), optimisation algorithms are developed following the Nelder-Mead algorithm. RESULTS: The reaction-opening force increases with a decreasing groove radius and an increasing position from the vertebra body. The created area increases with a decreasing groove radius and a decreasing position. As the opening happens mostly only above the groove, the opening area increases only in this location. Moreover, the von Mises stress peak value is almost twice as large as in the case of maximization of the opening area, which might result in breaking of the lamina as the thickness of the lamina would be reduced to its minimum. CONCLUSION: The groove radius and position can affect the opening force and the opening area in case of double door laminoplasty. The opening force is highly influenced by the groove position and radius. The best position for placing the groove is in the middle of the lamina and the radius of the groove should be as large as possible.


Assuntos
Laminoplastia , Algoritmos , Fenômenos Biomecânicos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Humanos , Laminoplastia/efeitos adversos , Tomografia Computadorizada por Raios X
3.
R Soc Open Sci ; 8(12): 210892, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34950485

RESUMO

Aseptic loosening due to periprosthetic osteolysis has been accepted as one of the leading causes of revision procedures in patients with previous joint arthroplasty. Recently, several strategies for suppression of osteolysis were proposed, mostly based on biological treatment such as mitigation of chronic inflammatory reactions. However, these biological treatments do not stop the debris migration but only reduce the inflammatory reaction. To address this shortcoming, we propose the concept of ultrahigh molecular weighted polyethylene particles filtration storage by electrospun membranes. Firstly, the surface tension of synovial fluid (SF) is obtained by use of a pendant droplet. Secondly, the contact angle of the electrospun membranes wetted by two different liquids is measured to obtain the free surface energy using of the Owens-Wendt model. Additionally, the wettability of electrospun membranes by SF as a function of technology parameters is studied.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA