Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Abdom Radiol (NY) ; 49(5): 1615-1625, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38652125

RESUMO

PURPOSE: To investigate the influence of deep learning reconstruction (DLR) on bladder MRI, specifically examination time, image quality, and diagnostic performance of vesical imaging reporting and data system (VI-RADS) within a prospective clinical cohort. METHODS: Seventy participants with bladder cancer who underwent MRI between August 2022 and February 2023 with a protocol containing standard T2-weighted imaging (T2WIS), standard diffusion-weighted imaging (DWIS), fast T2WI with DLR (T2WIDL), and fast DWI with DLR (DWIDL) were enrolled in this prospective study. Imaging quality was evaluated by measuring signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and qualitative image quality scoring. Additionally, the apparent diffusion coefficient (ADC) of bladder lesions derived from DWIS and DWIDL was measured and VI-RADS scoring was performed. Paired t-test or paired Wilcoxon signed-rank test were performed to compare image quality score, SNR, CNR, and ADC between standard sequences and fast sequences with DLR. The diagnostic performance for VI-RADS was assessed using the area under the receiver operating characteristic curve (AUC). RESULTS: Compared to T2WIS and DWIS, T2WIDL and DWIDL reduced the acquisition time from 5:57 min to 3:13 min and showed significantly higher SNR, CNR, qualitative image quality score of overall image quality, image sharpness, and lesion conspicuity. There were no significant differences in ADC and AUC of VI-RADS between standard sequences and fast sequences with DLR. CONCLUSIONS: The application of DLR to T2WI and DWI reduced examination time and significantly improved image quality, maintaining ADC and the diagnostic performance of VI-RADS for evaluating muscle invasion in bladder cancer.


Assuntos
Aprendizado Profundo , Imageamento por Ressonância Magnética , Neoplasias da Bexiga Urinária , Humanos , Estudos Prospectivos , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/patologia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Invasividade Neoplásica/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Idoso de 80 Anos ou mais , Adulto , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Difusão por Ressonância Magnética/métodos
2.
Quant Imaging Med Surg ; 11(1): 264-275, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33392027

RESUMO

BACKGROUND: Adaptive statistical iterative reconstruction-V technique (ASIR-V) is usually set at different strengths according to the different clinical requirements and scenarios encountered when setting scanning protocols, such as setting a more aggressive tube current reduction (defined as preset ASIR-V). Reconstruction with ASIR-V is useful after scanning using image algorithms to improve image quality (defined as postset ASIR-V). The aim of this study was to investigate the quality of images reconstructed with preset and postset ASIR-V, using the same noncontrast abdominal-pelvic computed tomography (CT) protocols in the same individual on a wide detector CT. METHODS: We prospectively enrolled 141 patients. The scan protocols in Groups A-E were 0%, 20%, 40%, 60%, and 80% preset ASIR-V, respectively, in the 256 wide-detector row Revolution CT (GE Healthcare, Waukesha, WI, USA). Each group was further divided into 5 subgroups with 0%, 20%, 40%, 60%, and 80% postset ASIR-V, respectively. The 64-detector Discovery 750 HDCT (GE, USA) was used for Group F as a control group, using 0%, 20%, 40%, 60%, and 80% ASIR, respectively. Image noise was measured in the spleen, aorta, and muscle. The CT attenuation and image noise were analyzed using the paired t-test; analysis of variance and post hoc multiple comparisons were made using the Student-Newman-Keuls (SNK) method. RESULTS: The CT attenuation in Groups A-F exhibited no significant difference between subgroups in three organs (P>0.05). Only with increasing preset ASIR-V% (Groups A to E), did the image noise decrease, except in Group B in the aorta and muscle (NoiseB > NoiseA, PmuscleA&B=0.233, PaortaA&B=0.796). Only with increasing postset ASIR-V or ASIR% (Groups A and F), did the image noise decrease in the three organs. After preset and postset ASIR-V were combined, with preset ASIR-V% being equal to postset ASIR-V%, the image become similar to the corresponding preset ASIR-V part with the line of postset ASIR-V 0% (baseline of each group). When preset ASIR-V% was greater than the postset ASIR-V%, the image noise was higher than the baseline of each group. When preset ASIR-V% was less than the postset ASIR-V%, the image noise was lower than the baseline of each group. The radiation dose from B to E decreased from 11.2% to 57.1%. The CT dose index volume (CTDIvol) and dose length product (DLP) in Group F were significantly higher than those in Group A. CONCLUSIONS: Using both preset and postset ASIR-V allows dose reduction, with a potential to improve image quality only when postset ASIR-V% is higher than or equal to preset ASIR-V%. The image quality depends on postset ASIR-V%, whereas the decrease of radiation dose depends on preset ASIR-V%.

3.
J Xray Sci Technol ; 21(4): 453-64, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24191984

RESUMO

Multi-phase spiral Computed tomography (CT) of abdomen has been widely used as an effective imaging modality to diagnose variety of diseases. As a result, the accumulated radiation exposure on the abdomen is substantially higher than other human organ regions. According to ALARA (as low as reasonably achievable) principle, how to control radiation dose without compromising imaging quality becomes a research topic of high interest. However, how to achieve dose optimization of the abdomen CT examinations in Chinese patients have not been fully investigated in previous studies. In this study, we develop an abdomen-equivalent tissue model made by well-known CTP579 auxiliary testing model and the real CT data acquired from 68 Chinese male subjects. Combining with catphan600, we simulated the visibility of low and high contrast objects at adult abdomen under variety of x-ray dose levels. Using the automatic tube current modulation (ATCM) technique, we reduced the total radiation dose and identified a proper noise index (NI) for Chinese patients to maintain low or high contrast detectability of abdominal CT image. Our numerical experiments showed that in the phantom study for Chinese patients, when a NI was set at 10, the radiation dose reduced by 34.3% with low contrast objects detectable, while setting NI at 14 the dose level decreased by 65.1% without change the detectability of high contrast targets. The subjective ratings from three radiologists also yielded high consistence with Kappa > 0.75. This study demonstrated the feasibility of performing the CT dose optimization studies through a unique phantom with the ATCM method.


Assuntos
Imagens de Fantasmas , Radiografia Abdominal/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Doses de Radiação , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA