Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Orthop Surg ; 16(1): 263-268, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37814793

RESUMO

OBJECTIVE: Heel fractures need extensive surgical incisions and are challenging to successfully reposition using traditional prying. The goal of this study is to evaluate the clinical effectiveness of using a Kirschner pin-guided distractor to treat inversion shortening calcaneal fractures in the "out-in" position. METHODS: A total of 40 data from 37 patients with inversion shortened calcaneal fractures from January 2018 to March 2020 were reviewed. Preoperative lateral and axial X-rays and 3D CT were taken to assess the fracture type, and minimally invasive internal fixation was performed in the "out-in" position with distractor repositioning, and intraoperative and postoperative images were taken to assess fracture repositioning and fixation. During the follow-up period, the postoperative functional recovery status was assessed using the VAS score, AOFAS score, and FAOS score. Paired-samples t-test was used for all data comparisons. RESULTS: All cases received a mean follow-up of 28.49 ± 3.25 months, and the mean fracture healing time was 7.84 ± 0.71 weeks. The postoperative images showed well-fixed fracture repositioning, and calcaneal height, length, width, and inversion angles were significantly improved. At the final follow-up, the calcaneal height, length, and width recovered from 39.35 ± 4.44mm, 79.35 ± 2.7mm, and 45.75 ± 2.87mm preoperatively to 50.93 ± 3.18mm, 82.23 ± 1.90mm, and 39.67 ± 1.58mm postoperatively (p < 0.001; p < 0.001; p < 0.001). The calcaneus inversion angle restored from 7.73° ± 2.26° to 3.80° ± 1.80° (p < 0.001). Böhler's angle and Gissane's angle improved from 13.13° ± 3.02° and 105.15° ± 8.94° to 27.95° ± 3.41° and 122.85° ± 5.54° (p < 0.001; p < 0.001). No non-healing fractures, osteomyelitis, or traumatic arthritis were observed. CONCLUSION: Minimally invasive internal fixation with distractor repositioning in the "out-in" position is effective in the treatment of inversion shortening calcaneal fractures while restoring the anatomy and protecting the soft tissue.


Assuntos
Traumatismos do Tornozelo , Calcâneo , Traumatismos do Pé , Fraturas Ósseas , Traumatismos do Joelho , Humanos , Seguimentos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Calcâneo/cirurgia , Traumatismos do Pé/cirurgia , Estudos Retrospectivos
2.
Biosensors (Basel) ; 13(9)2023 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-37754120

RESUMO

Electrochemical biosensors based on immobilized enzymes are among the most popular and commercially successful biosensors. The literature in this field suggests that modification of electrodes with nanomaterials is an excellent method for enzyme immobilization, which can greatly improve the stability and sensitivity of the sensor. However, the poor stability, weak reproducibility, and limited lifetime of the enzyme itself still limit the requirements for the development of enzyme electrochemical biosensors for food production process monitoring. Therefore, constructing sensing technologies based on enzyme electrochemical biosensors remains a great challenge. This article outlines the construction principles of four generations of enzyme electrochemical biosensors and discusses the applications of single-enzyme systems, multi-enzyme systems, and nano-enzyme systems developed based on these principles. The article further describes methods to improve enzyme immobilization by combining different types of nanomaterials such as metals and their oxides, graphene-related materials, metal-organic frameworks, carbon nanotubes, and conducting polymers. In addition, the article highlights the challenges and future trends of enzyme electrochemical biosensors, providing theoretical support and future perspectives for further research and development of high-performance enzyme chemical biosensors.

3.
Indian J Orthop ; 57(4): 571-576, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37006729

RESUMO

Objective: This study aimed to investigate the clinical efficacy of closed reduction high-strength sutures combined with Nice knots in treating transverse patella fractures. Method: We retrospectively analyzed the clinical data of 28 patients who underwent surgery for transverse patella fractures from January 2019 to January 2020. Twelve cases of the study group were treated with closed reduction high-strength sutures combined with Nice knots, and 16 cases in the control group were treated with tension band wiring. Observations included patellar healing, follow-up knee mobility with Böstman score, Lysholm score, surgical data, postoperative complications, and secondary surgery rate. Result: No statistically significant difference was observed between the two groups in the Patient demographic data, with a mean follow-up of 13.14 ± 1.58 months. There was no delayed healing or deep infection in the two groups. In the control group, 2 cases of internal fixation failure and 1 case of superficial infection were observed. The differences in mean fracture healing time, follow-up Böstman score, Lysholm score and knee mobility between the two groups were not statistically different. However, the differences were statistically significant for the duration of surgery, Incision length, intraoperative bleeding and the secondary surgery rate was lower in the study group. Conclusion: Closed reduction high-strength sutures have good clinical efficacy in treating transverse patella fractures, with the advantages of shorter duration of surgery and Incision length,less intraoperative bleeding and no secondary removal.

4.
BMC Musculoskelet Disord ; 23(1): 1068, 2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36471331

RESUMO

BACKGROUND: The commonly used technique for treating unstable pelvic fractures with sacroiliac screws and anterior internal fixator (INFIX) is prone to complications, such as injury to the pelvic vasculature and nerves, life-threatening bleeding, lateral femoral cutaneous neuritis, and wound infection. This study investigated the clinical effects of using a modified percutaneous iliosacral screw and INFIX technique for treating unstable pelvic fractures. METHODS: A retrospective analysis of minimally invasive internal fixation using modified incision of an anterior-ring INFIX application combined with modified percutaneous iliosacral screw placement was performed for 22 cases of unstable pelvic fractures from January 2017 to December 2018. Based on the Tile classification, there were 4 type B1, 7 type B2, 5 type B3 and 6 type C1 injuries. Preoperatively, the length and orientation of the internal fixation were computer-simulated and measured. On postoperative day 3, pelvic radiographs and three-dimensional computed tomograms were used to assess fracture reduction and fixation. All patients were regularly followed up at 4 weeks, 12 weeks, 6 months, 12 months, 24 months and annually thereafter. Fracture healing, complications, visual analogue scale (VAS) scores, the quality of fracture repositioning and Majeed score were assessed during follow-up. RESULTS: All patients were followed up for a mean of 25.23 ± 1.48 months. All fractures healed without loss of reduction and no patient showed evidence of delayed union or nonunion. Two years postoperatively, the mean VAS score was 0.32 ± 0.09 and the mean Majeed score was 94.32 ± 1.86. CONCLUSION: The modified percutaneous iliosacral screw technique increases the anterior tilt of the sacroiliac screw by shifting the entry point posteriorly to increase the safety of the screw placement. Downward modification of the INFIX incision reduces the risk of lateral femoral cutaneous nerve injury. This technique is safe, effective and well tolerated by patients.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Humanos , Estudos Retrospectivos , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/cirurgia , Ossos Pélvicos/lesões , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fixadores Internos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA