Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Front Pharmacol ; 12: 716224, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34744710

RESUMO

Background: The drug therapy of venous thromboembolism (VTE) presents a significant economic burden to the health-care system in low- and middle-income countries. To understand which anticoagulation therapy is most cost-effective for clinical decision-making , the cost-effectiveness of apixaban (API) versus rivaroxaban (RIV), dabigatran (DAB), and low molecular weight heparin (LMWH), followed by vitamin K antagonist (VKA), in the treatment of VTE in China was assessed. Methods: To access the quality-adjusted life-years (QALYs) and incremental cost-effectiveness ratios (ICERs), a long-term cost-effectiveness analysis was constructed using a Markov model with 5 health states. The Markov model was developed using patient data collected from the Xijing Hospital from January 1, 2016 to January 1, 2021. The time horizon was set at 30 years, and a 6-month cycle length was used in the model. Costs and ICERs were reported in 2020 U.S. dollars. One-way sensitivity analysis and probabilistic sensitivity analysis (PSA) were used to test the uncertainties. A Chinese health-care system perspective was used. Results: In the base case, the data of 231 VTE patients were calculated in the base case analysis retrospectively. The RIV group resulted in a mean VTE attributable to 95% effective treatment. API, DAB, and VKA have a negative ICER (-187017.543, -284,674.922, and -9,283.339, respectively) and were absolutely dominated. The Markov model results confirmed this observation. The ICER of the API and RIV was negative (-216176.977), which belongs to the absolute inferiority scheme, and the ICER value of the DAB and VKA versus RIV was positive (110,577.872 and 836,846.343). Since the ICER of DAB and VKA exceeds the threshold, RIV therapy was likely to be the best choice for the treatment of VTE within the acceptable threshold range. The results of the sensitivity analysis revealed that the model output varied mostly with the cost in the DAB on-treatment therapy. In a probabilistic sensitivity analysis of 1,000 patients for 30 years, RIV has 100% probability of being cost-effective compared with other regimens when the WTP is $10973 per QALY. When WTP exceeded $148,000, DAB was more cost-effective than RIV. Conclusions: Compared with LMWH + VKA and API, the results proved that RIV may be the most cost-effective treatment for VTE patients in China. Our findings could be helpful for physicians in clinical decision-making to select the appropriate treatment option for VTE.

2.
Biomed Res Int ; 2020: 3056395, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33294437

RESUMO

We aimed to design an individualized intra-articular stabilization device based on 3D printing technology and investigate the clinical effects of this device for treating traumatic instability of the ulnohumeral joint. This study enrolled nine patients with traumatic instability of the ulnohumeral joint (age: 47.2 ± 1.80 years) who received treatment between March 2018 and March 2019 in our hospital. All patients underwent a thin-layer computed tomography (CT) scan of the elbow before surgery. The original injury and repair models of the elbow were printed using 3D printing technology based on CT data. An individualized intra-articular stabilization device was designed with a 2.0 mm Kirschner wire based on the repair model. Nine patients agreed to receive surgical treatment for elbow disease and placement of the intra-articular stabilization device. The nine patients underwent open reduction through a posterior median approach, and the intra-articular stabilization device was placed in the elbow. Operation time, intraoperative blood loss, and postoperative complications were recorded and followed up. The device was removed at two postoperative months, and the Mayo score was used to evaluate elbow function. Four months after removing the intra-articular stabilization device, elbow joint function was evaluated again using the Mayo score. The mean operation time was 100.1 ± 8.2 min, and the mean intraoperative blood loss was 35.5 ± 7.1 ml. No complications occurred after operation. Two months after surgery, eight patients received an excellent Mayo score, and one patient received a good Mayo score. Four months after removal of the intra-articular stabilization device, eight patients received an excellent Mayo score, and one patient received a good Mayo score. The individualized intra-articular stabilization device can increase ulnohumeral stability and achieve rapid functional recovery of the elbow.


Assuntos
Articulação do Cotovelo/fisiopatologia , Úmero/fisiopatologia , Instabilidade Articular/fisiopatologia , Impressão Tridimensional/instrumentação , Ulna/fisiopatologia , Ferimentos e Lesões/fisiopatologia , Adulto , Articulação do Cotovelo/diagnóstico por imagem , Feminino , Humanos , Úmero/diagnóstico por imagem , Instabilidade Articular/complicações , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Ulna/diagnóstico por imagem , Ferimentos e Lesões/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA