Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
J Hazard Mater ; 477: 135366, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-39088943

RESUMO

Deoxynivalenol-3-glucoside (D3G), the masked form of the important mycotoxin deoxynivalenol (DON), displays potential toxicity but is difficult to control owing to the lack of rapid detection methods. Herein, an innovative molecularly imprinted polymer (MIP)-based electrochemical sensor was developed for the rapid detection of D3G. MIP, an efficient recognition element for D3G, was electropolymerized using o-phenylenediamine based on a surface functional monomer-directing strategy for the first time. CeO2, which contains both Ce3+ and Ce4+ oxidation states, was introduced as a nanozyme to catalyze H2O2 reduction, while Mn doping generated more oxygen vacancies and considerably improved the catalytic activity. Mn-CeO2 also served as a promising substrate material because of its large surface area and excellent conductivity. Under optimal conditions, a good linear relationship was observed for D3G detection over the concentration range of 0.01-50 ng/mL. The proposed sensor could detect D3G down to 0.003 ng/mL with excellent selectivity, even distinguishing its precursor DON in complex samples. The sensor exhibited acceptable stability with high reproducibility and accuracy, and could successfully determine D3G in grain samples. To the best of our knowledge, this is the first electrochemical sensing platform for rapid D3G detection that can easily be expanded to other masked mycotoxins.


Assuntos
Cério , Técnicas Eletroquímicas , Manganês , Tricotecenos , Tricotecenos/análise , Tricotecenos/química , Cério/química , Manganês/química , Polímeros Molecularmente Impressos/química , Impressão Molecular , Polímeros/química , Reprodutibilidade dos Testes , Grão Comestível/química , Limite de Detecção , Glucosídeos/química , Glucosídeos/análise , Contaminação de Alimentos/análise , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise
2.
Pharmacogenomics ; : 1-9, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38884946

RESUMO

Aim: To estimate the cost-effectiveness of zolbetuximab plus capecitabine/oxaliplatin (CAPOX) in CLDN18.2-positive, HER2-negative, mG/GEJ adenocarcinoma from the perspective of Chinese payers. Materials & methods: A partitioned survival model was developed to assess the costs, quality-adjusted life years (QALYs) and incremental cost-effectiveness ratios (ICER) of zolbetuximab plus CAPOX versus placebo plus CAPOX. Sensitivity analyses were performed to test the robustness of model. Results: Zolbetuximab plus CAPOX gained an additional cost of $91,551 and an extra health benefit of 0.24 QALY over placebo plus CAPOX, producing an ICER of $388,186/QALY, which exceeded the willingness-to-pay threshold of $38,223/QALY. Sensitivity analysis shows that the model was generally robust. Conclusion: Zolbetuximab plus CAPOX would not be a cost-effective first-line treatment regimen in CLDN18.2-positive, HER2-negative, mG/GEJ adenocarcinoma in China.


[Box: see text].

3.
Adv Mater ; 36(16): e2311474, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38194906

RESUMO

During liver fibrogenesis, the reciprocal crosstalk among capillarized liver sinusoidal endothelial cells (LSECs), activated hepatic stellate cells (HSCs), and dysfunctional hepatocytes constructs a self-amplifying vicious cycle, greatly exacerbating the disease condition and weakening therapeutic effect. Limited by the malignant cellular interactions, the previous single-cell centric treatment approaches show unsatisfactory efficacy and fail to meet clinical demand. Herein, a vicious cycle-breaking strategy is proposed to target and repair pathological cells separately to terminate the malignant progression of liver fibrosis. Chondroitin sulfate-modified and vismodegib-loaded nanoparticles (CS-NPs/VDG) are designed to efficiently normalize the fenestrae phenotype of LSECs and restore HSCs to quiescent state by inhibiting Hedgehog signaling pathway. In addition, glycyrrhetinic acid-modified and silybin-loaded nanoparticles (GA-NPs/SIB) are prepared to restore hepatocytes function by relieving oxidative stress. The results show successful interruption of vicious cycle as well as distinct fibrosis resolution in two animal models through multiregulation of the pathological cells. This work not only highlights the significance of modulating cellular crosstalk but also provides a promising avenue for developing antifibrotic regimens.


Assuntos
Células Endoteliais , Lipossomos , Nanopartículas , Animais , Células Endoteliais/metabolismo , Proteínas Hedgehog/metabolismo , Proteínas Hedgehog/uso terapêutico , Cirrose Hepática , Fígado/metabolismo
4.
Rev. bras. cir. cardiovasc ; 38(5): e20220402, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1449577

RESUMO

ABSTRACT Objective: To investigate the accuracy of aortic dimensions measured by Revolution™ computed tomography (CT) in infants with complex coarctation of the aorta (CoA) and to further analyze the utility of the degree of CoA in predicting the risk of prolonged postoperative cardiac intensive care unit stay. Methods: A total of 30 infants with complex CoA who underwent surgical correction from January 2020 to July 2022 were retrospectively enrolled. General demographic data, preoperative imaging, and perioperative outcomes were collected. Univariate and multivariate analyses were performed to investigate predictors of prolonged postoperative cardiac intensive care unit stay, and the reliability of the CT measurements was assessed by the intraclass correlation coefficient. Results: All infants were divided into a mild or severe CoA group. The duration of mechanical ventilation and cardiac intensive care unit stay in the mild CoA group were significantly lower than those in the severe CoA group. After multivariate analysis, we found that the degree of CoA and age at surgery were significant predictors of prolonged postoperative cardiac intensive care unit stay. The intraclass correlation coefficient between CT measurements and intraoperative measurements was between 0.937 and 0.975, and the measurement results had good reliability. Conclusion: CT angiography can provide a comprehensive and accurate preoperative evaluation of aortic dimensions measured in infants with complex CoA. The degree of CoA is an independent risk factor for prolonged postoperative cardiac intensive care unit stay in infants with complex CoA.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA