Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMC Complement Med Ther ; 24(1): 43, 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38245739

RESUMO

OBJECTIVE: To investigate the changes in amplitude of low-frequency fluctuation (ALFF) and degree centrality (DC) values before and after acupuncture in young women with non-menstrual migraine without aura (MWoA) through rest blood-oxygen-level-dependent functional magnetic resonance imaging (BOLD fMRI). METHODS: Patients with non-menstrual MWoA (Group 1, n = 50) and healthy controls (Group 2, n = 50) were recruited. fMRI was performed in Group 1 at 2 time points: before acupuncture (time point 1, TP1); and after the end of all acupuncture sessions (time point 2, TP2), and performed in Group 2 as a one-time scan. Patients in Group 1 were assessed with the Migraine Disability Assessment Questionnaire (MIDAS) and the Short-Form McGill Pain Questionnaire (SF-MPQ) at TP1 and TP2 after fMRI was performed. The ALFF and DC values were compared within Group 1 at two time points and between Group 1 and Group2. The correlation between ALFF and DC values with the statistical differences and the clinical scales scores were analyzed. RESULTS: Brain activities increased in the left fusiform gyrus and right angular gyrus, left middle occipital gyrus, and bilateral prefrontal cortex and decreased in left inferior parietal lobule in Group 1, which had different ALFF values compared with Group 2 at TP1. The bilateral fusiform gyrus, bilateral inferior temporal gyrus and right middle temporal gyrus increased and right angular gyrus, right superior marginal gyrus, right inferior parietal lobule, right middle occipital gyrus, right superior frontal gyrus, right middle frontal gyrus, right anterior central gyrus, and right supplementary motor area decreased in activity in Group 1 had different DC values compared with Group 2 at TP1. ALFF and DC values of right inferior temporal gyrus, right fusiform gyrus and right middle temporal gyrus were decreased in Group1 at TP1 compared with TP2. ALFF values in the left middle occipital area were positively correlated with the pain degree at TP1 in Group1 (correlation coefficient r, r = 0.827, r = 0.343; P < 0.01, P = 0.015). The DC values of the right inferior temporal area were positively correlated with the pain degree at TP1 in Group 1 (r = 0.371; P = 0.008). CONCLUSION: Spontaneous brain activity and network changes in young women with non-menstrual MwoA were altered by acupuncture. The right temporal area may be an important target for acupuncture modulated brain function in young women with non-menstrual MwoA.


Assuntos
Terapia por Acupuntura , Enxaqueca sem Aura , Humanos , Feminino , Imageamento por Ressonância Magnética/métodos , Lobo Occipital/diagnóstico por imagem , Dor
2.
Transl Clin Pharmacol ; 30(1): 37-48, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35419315

RESUMO

A liquid chromatography equipped with tandem mass spectrometric method using multi-stage flow rates was developed for the determination of donepezil in human plasma to support a randomized, crossover bioequivalence (BE) study in which healthy volunteers each received a single oral dose of the reference and test formulations of 10 mg donepezil hydrochloride. This integrated liquid chromatography with tandem mass spectrometry (LC-MS/MS) system with electrospray ionization and a deuterium-labeled internal standard (IS) were employed for the positive multiple-reaction-monitoring (MRM) analyses. The baseline separation using a high-resolution monolithic column under gradient and flexible flowrate conditions between donepezil and multiple interfering peaks from the extracted quality control, calibration standard and study plasma samples following simple protein precipitation extraction procedures was accomplished within 1.5 minutes. The ultrafast monolithic column performance in terms of chromatographic separation efficiency, peak asymmetry and resolution and retention time reproducibility was found to be sustainable. The linear dynamic range was detected over a concentration range of 0.2-50 ng/mL. The intra- and inter-day assay accuracy and precision were within 15% for the analyte in individual biological fluids. A positive correlation coefficient (r) greater than 0.995 for donepezil concentrations in study plasma samplers measured by the proposed and the other validated LC-MS/MS methods in support of a bioequivalence study was observed.

3.
J Pharm Biomed Anal ; 211: 114596, 2022 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-35104737

RESUMO

Ultra-high-performance liquid chromatography (UHPLC) hyphenated to tandem mass spectrometric methods using the dimethylpentafluorophenylpropyl stationary phase with polar and nonpolar characteristics of a 2-µm fused-core silica particle packing were evaluated to perform efficient separation for the analysis of donepezil in human plasma. The fused-core silica particle design providing the shorter diffusional mass transfer path for the analytes is less affected in resolving power by increasing mobile-phase velocity for faster chromatographic resolution between the administered compound and multiple interfering peaks from the extracted quality control, calibration standard and study samples following simple protein precipitation extraction procedures. In this work, two UHPLC-MS/MS approaches requiring 1.2 min per sample run time and neither expensive ultra-high-pressure instrumentation nor new laboratory protocols were applied and compared for determination of donepezil in human plasma at sub-nanograms per milliliter region to support a randomized, crossover bioequivalence (BE) study in which healthy volunteers each received a single oral dose of the test and reference formulations of 10 mg donepezil hydrochloride. The column performance in terms of chromatographic separation efficiency, peak asymmetry and resolution and retention time reproducibility was found to be sustainable over a thousand extracted plasma injections. The linear dynamic range was detected over a concentration range of 0.2-50 ng/mL. The intra- and inter-day assay accuracy and precision were within 15% for the analyte in individual biological fluids. Positive correlation coefficients (r) greater than 0.98 and 0.99 for donepezil concentrations in study plasma samplers measured by the proposed UHPLC-MS/MS approaches and another validated HPLC-MS/MS method were observed.


Assuntos
Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão/métodos , Donepezila , Humanos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Equivalência Terapêutica
4.
Neuropsychiatr Dis Treat ; 18: 187-199, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35153482

RESUMO

OBJECTIVE: To investigate the changes of regional homogeneity (Reho) values before and after spinal manipulative therapy (SMT) in patients with chronic low back pain (CLBP) through rest blood-oxygen-level-dependent functional magnetic resonance imaging (BOLD fMRI). METHODS: Patients with CLBP (Group 1, n = 20) and healthy control subjects (Group 2, n = 20) were recruited. The fMRI was performed three times in Group 1 before SMT (time point 1, TP1), after the first SMT (time point 2, TP2), after the sixth SMT (time point 3, TP3), and for one time in Group 2, which received no intervention. The clinical scales were finished in Group 1 every time before fMRI was performed. The Reho values were compared among Group 1 at different time points, and between Group 1 and Group 2. The correlation between Reho values with the statistical differences and the clinical scale scores were calculated. RESULTS: The bilateral precuneus and right mid-frontal gyrus in Group 1 had different Reho values compared with Group 2 at TP1. The Reho values were increased in the left precuneus and decreased in the left superior frontal gyrus in Group 1 at TP2 compared with TP1. The Reho values were increased in the left postcentral gyrus and decreased in the left posterior cingulate cortex and the superior frontal gyrus in Group 1 at TP3 compared with TP1. The ReHo values of the left precuneus in Group 1 at TP1 were negatively correlated with the pain degree at TP1 and TP2 (r = -0.549, -0.453; p = 0.012, 0.045). The Reho values of the middle temporal gyrus in Group 1 at TP3 were negatively correlated with the changes of clinical scale scores between TP3 and TP1 (r = 0.454, 0.559; p = 0.044, 0.01). CONCLUSION: Patients with CLBP showed abnormal brain function activity, which was altered after SMT. The Reho values of the left precuneus could predict the immediate analgesic effect of SMT.

5.
Guang Pu Xue Yu Guang Pu Fen Xi ; 29(12): 3275-8, 2009 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-20210149

RESUMO

In the present paper a method based on Vis/NIR spectral analysis technology was applied to the nondestructive measurement of plant chlorophyll content. Firstly, the Vis/NIR spectra in the wavelength range from 500 to 900 nm of the plant leaves were acquired from 35 samples by transmittance and reflectance method, and then three different mathematical treatments were used in original spectra data pretreatment to decrease the noise: moving average smoothing with the segment size 5, first Savitzky-Golay derivative, and wavelet transform (WT) way. Secondly, a total of 35 samples were examined in the test, in which 23 samples were selected randomly for model building and the other 12 for model prediction, then partial least squares (PLS) method was used to develop the quantitative analysis model for chlorophyll content with absorbance spectroscopy, and 7 principal components (PCs) were selected. Finally, this model was used to predict the chlorophyll content of 12 unknown leaf samples in prediction collection. The experiment result indicated that the better prediction performance was achieved with the correlation coefficient between the prediction values and the truth values being 0.93, and the root mean squared error of prediction is about 1.1 SPAD. It could be concluded that it is feasible to measure plant chlorophyll content based on visible/near infrared (Vis/NIR) spectroscopy. And it is also significant in realizing rapid and nondestructive measurement of chlorophyll content in the future.


Assuntos
Clorofila/análise , Folhas de Planta/química , Espectroscopia de Luz Próxima ao Infravermelho , Análise dos Mínimos Quadrados
6.
J Colloid Interface Sci ; 255(2): 299-302, 2002 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-12505077

RESUMO

The spontaneous formation of Ag nanoparticles in a dimethylacetamide (DMAC) solution of poly(ethylene glycol) (PEG) was studied. FTIR analysis showed the formation of carbonyl groups, revealing that PEG acted as not only a protective agent but also a reducing agent in the formation of Ag nanoparticles. Since no significant reactions were observed when poly(tetramethylene glycol) (PTMG) was used to replace PEG or acetonitrile was used to replace DMAC, it was suggested that PEG molecules might be coiled to form pseudo-crown ether cavities, in which Ag complexes were bound to the oxyethylene groups and reduced, and that the use of a solvent which might appropriately solvate the Ag salt was important for the formation of Ag nanoparticles. In addition, the mean diameters of the resultant Ag nanoparticles were 3.8-9.0 nm, increasing with increasing AgNO(3) concentration. A sufficiently high PEG concentration relative to AgNO(3) was necessary for the formation of smaller Ag nanoparticles. This work provided a simple route for the in situ synthesis of Ag nanoparticles.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA