Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 153
Filtrar
1.
Bone Joint J ; 106-B(5 Supple B): 105-111, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688516

RESUMO

Aims: Instability is a common indication for revision total hip arthroplasty (THA). However, even after the initial revision, some patients continue to have recurrent dislocation. The aim of this study was to assess the risk for recurrent dislocation after revision THA for instability. Methods: Between 2009 and 2019, 163 patients underwent revision THA for instability at Stanford University Medical Center. Of these, 33 (20.2%) required re-revision due to recurrent dislocation. Cox proportional hazard models, with death and re-revision surgery for periprosthetic infection as competing events, were used to analyze the risk factors, including the size and alignment of the components. Paired t-tests or Wilcoxon signed-rank tests were used to assess the outcome using the Veterans RAND 12 (VR-12) physical and VR-12 mental scores, the Harris Hip Score (HHS) pain and function, and the Hip disability and Osteoarthritis Outcome score for Joint Replacement (HOOS, JR). Results: The median follow-up was 3.1 years (interquartile range 2.0 to 5.1). The one-year cumulative incidence of recurrent dislocation after revision was 8.7%, which increased to 18.8% at five years and 31.9% at ten years postoperatively. In multivariable analysis, a high American Society of Anesthesiologists (ASA) grade (hazard ratio (HR) 2.72 (95% confidence interval (CI) 1.13 to 6.60)), BMI between 25 and 30 kg/m2 (HR 4.31 (95% CI 1.52 to 12.27)), the use of specialized liners (HR 5.39 (95% CI 1.97 to 14.79) to 10.55 (95% CI 2.27 to 49.15)), lumbopelvic stiffness (HR 6.03 (95% CI 1.80 to 20.23)), and postoperative abductor weakness (HR 7.48 (95% CI 2.34 to 23.91)) were significant risk factors for recurrent dislocation. Increasing the size of the acetabular component by > 1 mm significantly decreased the risk of dislocation (HR 0.89 (95% CI 0.82 to 0.96)). The VR-12 physical and HHS (pain and function) scores improved significantly at mid term. Conclusion: Patients requiring revision THA for instability are at risk of recurrent dislocation. Higher ASA grades, being overweight, a previous lumbopelvic fusion, the use of specialized liners, and postoperative abductor weakness are significant risk factors.


Assuntos
Artroplastia de Quadril , Instabilidade Articular , Recidiva , Reoperação , Humanos , Artroplastia de Quadril/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Instabilidade Articular/cirurgia , Instabilidade Articular/etiologia , Fatores de Risco , Falha de Prótese , Luxação do Quadril/cirurgia , Luxação do Quadril/etiologia , Estudos Retrospectivos , Prótese de Quadril , Complicações Pós-Operatórias/cirurgia , Complicações Pós-Operatórias/etiologia
2.
J Arthroplasty ; 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38417557

RESUMO

BACKGROUND: In collaboration with the Orthopedic Data Evaluation Panel (ODEP), the American Joint Replacement Registry (AJRR) investigated the consistency of hip and knee arthroplasty survivorship results compared to the UK National Joint Registry (NJR). METHODS: A total of three primary knee devices and three primary hip devices were selected by AJRR and ODEP with known variation in performance. Implant manufacturers independently produced Kaplan Meier survivorship based on NJR data and submitted to ODEP for comparison. The AJRR mirrored the methodology, and results from both sources were stratified into three cohorts (all-age, < 65, and ≥ 65 years). RESULTS: There were 42,671 AJRR and 60,439 NJR primary knee cases and 70,169 AJRR and 422,657 NJR primary total hip arthroplasty cases. For TKA, performance between the AJRR and NJR were consistent, showing similar trends for comparatively high and low performing devices. Both PS and CR devices showed statistical agreement in survivorship for all 3 cohorts. Unicompartmental comparison also showed statistical agreement for the Medicare cohort. The all-age and < 65-year-old cohorts showed similar trends and reached statistical agreement through 7 and 6 years. For total hip arthroplasty, performance between the AJRR and NJR were consistent, showing similar trends for comparatively high and low performing devices; 0.18% average difference in survivorship at final follow-up (8 years). One femoral device did not reach statistical agreement but showed only 0.61% difference in survivorship. The remaining acetabular and femoral devices reached statistical agreement in all-ages and through 7 and 8 years in the ≥ 65-year-old cohort. CONCLUSIONS: AJRR and NJR performance trends and survivorship were similar across hip and knee arthroplasty with greatest consistency in the all-age and ≥ 65 cohorts. This focused comparison of survivorship showed encouraging results for reliability of patient outcomes in AJRR compared to the world's largest joint arthroplasty registry which has strong implications for global improvement in patient safety.

3.
J Arthroplasty ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38417556

RESUMO

BACKGROUND: Optimal soft-tissue management in total knee arthroplasty (TKA) may reduce symptomatic instability. We hypothesized that TKA outcomes using a computer-assisted dynamic ligament balancer that acquires medial and lateral gap sizes throughout the motion arc would show improved Knee Society Scores (KSS) compared to TKAs done with a traditional tensioner at 0 and 90°. We also sought to quantify the degree to which the planned femoral rotation chosen to optimize medio-lateral balance throughout the arc of motion deviated from the femoral rotation needed to achieve a rectangular flexion gap at 90° alone. METHODS: Baseline demographics, clinical outcomes, KSSs, and femoral rotations were compared in 100 consecutive, computer-assisted TKAs done with the balancer (balancer group) to the immediately prior 100 consecutive computer-assisted TKAs done without the balancer (control group). Minimum follow-up was 13 months and all patients had osteoarthritis. Mean knee motion did not differ preoperatively (110.1 ± 13.6° balancer, 110.4 ± 12.5° control, P = .44) or postoperatively (119.1 ± 10.3° balancer, 118.8 ± 10.9° control, P = .42). Tourniquet times did not differ (93.1 ± 13.0 minutes balancer, 90.7 ± 13.0 minutes control, P = .13). Postoperative length of stay differed (40.2 ± 20.9 hours balancer, 49.0 ± 18.3 hours control, P = .0009). There were 14 readmissions (7 balancer, 7 control), 11 adverse events (4 balancer, 7 control), and 3 manipulations (1 balancer, 2 control). The cohorts were compared using Student's t-tests, Shapiro-Wilk normalities, Wilcoxon rank-sums, and multivariable logistic regression analyses. RESULTS: Postoperative KSS improvements were higher in the balancer group (P < .0001). In multivariable regression analyses, the balancer group experienced 7 ± 2 point improvement in KSS Knee scores (P < .0001) and 4 ± 2 point improvement in KSS Function scores (P = .040) compared to the control group. CONCLUSIONS: The statistically and clinically significant improvements in postoperative KSS demonstrated in the balancer cohort are likely driven by improved stability throughout the motion arc. Further study is warranted to evaluate replicability by non-design surgeons.

4.
J Orthop Res ; 42(3): 560-567, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38093490

RESUMO

Approximately 20% of patients after resection arthroplasty and antibiotic spacer placement for prosthetic joint infection develop repeat infections, requiring an additional antibiotic spacer before definitive reimplantation. The host and bacterial characteristics associated with the development of recurrent infection is poorly understood. A case-control study was conducted for 106 patients with intention to treat by two-stage revision arthroplasty for prosthetic joint infection at a single institution between 2009 and 2020. Infection was defined according to the 2018 Musculoskeletal Infection Society criteria. Thirty-nine cases ("recurrent-periprosthetic joint infection [PJI]") received at least two antibiotic spacers before clinical resolution of their infection, and 67 controls ("single-PJI") received a single antibiotic cement spacer before infection-free prosthesis reimplantation. Patient demographics, McPherson host grade, and culture results including antibiotic susceptibilities were compared. Fifty-two (78%) single-PJI and 32 (82%) recurrent-PJI patients had positive intraoperative cultures at the time of their initial spacer procedure. The odds of polymicrobial infections were 11-fold higher among recurrent-PJI patients, and the odds of significant systemic compromise (McPherson host-grade C) were more than double. Recurrent-PJI patients were significantly more likely to harbor Staphylococcus aureus. We found no differences between cases and controls in pathogen resistance to the six most tested antibiotics. Among recurrent-PJI patients, erythromycin-resistant infections were more prevalent at the final than initial spacer, despite no erythromycin exposure. Our findings suggest that McPherson host grade, polymicrobial infection, and S. aureus infection are key indicators of secondary or persistent joint infection following resection arthroplasty and antibiotic spacer placement, while bacterial resistance does not predict infection-related arthroplasty failure.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Infecções Relacionadas à Prótese , Humanos , Estudos de Casos e Controles , Staphylococcus aureus , Artrite Infecciosa/tratamento farmacológico , Antibacterianos/uso terapêutico , Próteses e Implantes , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Reoperação , Estudos Retrospectivos , Artroplastia de Quadril/métodos , Resultado do Tratamento
5.
Hip Int ; 34(1): 134-143, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37128124

RESUMO

PURPOSE: The aim of the study was to determine the restoration of hip biomechanics through lateral offset, leg length, and acetabular component position when comparing non-arthroplasty surgeons (NAS) to elective arthroplasty surgeons (EAS). METHODS: 131 patients, with a femoral neck fracture treated with a THA by 7 EAS and 20 NAS, were retrospectively reviewed. 2 blinded observers measured leg-length discrepancy, femoral offset, and acetabular component position. Multivariate logistic regression models examined the association between the surgeon groups and restoration of lateral femoral, acetabular offset, leg length discrepancy, acetabular anteversion, acetabular position, and component size, while adjusting for surgical approach and spinal pathology. RESULTS: NAS under-restored 4.8 mm of lateral femoral offset (43.9 ± 8.7 mm) after THA when compared to the uninjured side (48.7 ± 7.1 mm, p = 0.044). NAS were at risk for under-restoring lateral femoral offset when compared to EAS (p = 0.040). There was no association between lateral acetabular offset, leg length, acetabular position, or component size and surgeon type. CONCLUSIONS: Lateral femoral offset is at risk for under-restoration after THA for femoral neck fractures, when performed by surgeons that do not regularly perform elective THA. This indicates that lateral femoral offset is an under-appreciated contributor to hip instability when performing THA for a femoral neck fracture. Lateral femoral offset deserves as much attention and awareness as acetabular component position since a secondary analysis of our data reveal that preoperative templating and intraoperative imaging did not prevent under-restoration.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Fêmur , Desigualdade de Membros Inferiores/etiologia , Desigualdade de Membros Inferiores/cirurgia , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia
6.
J Arthroplasty ; 39(3): 683-688, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37625465

RESUMO

BACKGROUND: Over the past couple of decades, the definition of success after total knee arthroplasty (TKA) has shifted away from clinician-rated metrics and toward the patient's subjective experience. Therefore, understanding the aspects of patient recovery that drive 3-year to 5-year satisfaction after TKA is crucial. The aims of this study were to (1) determine the 1-year postoperative factors, specifically patient-reported outcome measures (PROMs) that were associated with 3-year and 5-year postoperative satisfaction and (2) understand the factors that drive those who are not satisfied at 1 year postoperatively to become satisfied later in the postoperative course. METHODS: This was a retrospective study of 402 TKA patients who were gathered prospectively and presented for their 1-year follow-up. Demographics were collected preoperatively and patient-reported outcomes were collected at 1, 3, and 5 years postoperatively. Logistic regressions were used to identify the factors at 1 year that were associated with 3-year and 5-year satisfaction. RESULTS: Associations between 1-year PROMs with 3-year satisfaction were observed. Longer term satisfaction at 5 years was more closely associated with EuroQol 5 Dimension Mobility, Activity Score, and Numerical Rating Scale Satisfaction. Of those who were not satisfied at 1 year, EuroQol 5 Dimension Mobility, Knee Disability Osteoarthritis Outcome Score Function in Sport and Recreation, and Satisfaction were associated with becoming satisfied at 3 years. CONCLUSION: The 1-year PROMs were found to be associated with satisfaction at 3 to 5 years after TKA. Importantly, many of the PROMs that were associated with 3-year to 5-year satisfaction, especially in those who were not originally satisfied at 1 year, were focused on mobility and activity level.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Satisfação do Paciente , Estudos Retrospectivos , Osteoartrite do Joelho/cirurgia , Medidas de Resultados Relatados pelo Paciente , Resultado do Tratamento , Articulação do Joelho/cirurgia
7.
Instr Course Lect ; 73: 131-151, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38090893

RESUMO

Although total hip arthroplasty (THA) has proved to be a successful surgical procedure, both prosthetic and bone impingement resulting in dislocation continue to occur. Studies have shown that spine pathology resulting in lumbar stiffness and hip arthritis often coexist. Spinopelvic mobility patterns during postural changes affect three-dimensional acetabular component position, which affects the incidence of prosthetic impingement and THA instability. Several spinopelvic risk factors that may affect THA stability have been identified. Numerous reports recommend performing a preoperative spinopelvic mobility analysis to identify risk factors and adjust acetabular component position accordingly to lessen the risk of impingement. In doing so, acetabular component position is individualized based on spinopelvic mobility patterns. Additionally, functional femoral anteversion, affected by individual femoral rotation patterns during dynamic activities, may contribute to the incidence of impingement. It is important to review the interrelationship between spine and pelvic mobility and how it relates to THA and may reduce the incidence of instability.


Assuntos
Artroplastia de Quadril , Luxações Articulares , Humanos , Acetábulo , Artroplastia de Quadril/efeitos adversos , Luxações Articulares/etiologia , Luxações Articulares/cirurgia , Pelve/cirurgia , Coluna Vertebral/cirurgia
8.
Surg Technol Int ; 432023 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-38038174

RESUMO

INTRODUCTION: Certain patient and operative factors limit accurate estimation of acetabular component positioning during total hip arthroplasty (THA). This study aimed to determine whether an intraoperative external alignment guide decreases variance in acetabular component positioning. MATERIALS AND METHODS: Adult patients who underwent primary THA from 2014-2018 were reviewed. Exclusion criteria were navigation, robot-assisted surgery, and inflammatory, post-traumatic, or avascular arthritis. One surgeon used an external guide while the second surgeon resected osteophytes and utilized available anatomical landmarks for positioning. Anteversion and inclination, variance, "safe zone" positioning, operative time, and hip instability were assessed. Multivariable regression models were used to examine effects on primary and secondary outcomes. RESULTS: 409 patients were included, of which 182 underwent component placement with landmarks only. Patients undergoing component placement with landmarks only were younger (p=0.002) and more often smokers (p=0.016). After multivariable risk adjustment, use of the external alignment guide was independently associated with 2.7° higher anteversion (CI: 1.6° to 3.8°) and smaller anteversion variance (-0.3, CI: -0.6 to 0.1) compared to landmarks only. It was independently associated with 3.2° higher inclination (CI: 2.0° to 4.4°), but there was no difference in inclination variance (-0.1, CI: -0.3 to 0.2). The external alignment guide was independently associated with a 14-minute shorter operative time (CI: 9.6 to 18.7) and smaller operative time variance (-0.9, CI: -1.2 to 0.6). DISCUSSION: Use of anatomical landmarks alone was associated with increased likelihood of safe zone positioning but lower precision and longer operative time. While this study was limited by lack of randomization and its retrospective nature, an acetabular positioner may be preferable to palpable or visible anatomy alone for acetabular component placement.

10.
J Hip Preserv Surg ; 10(2): 63-68, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37900893

RESUMO

Iliopsoas (IP) tendinitis from impingement upon the acetabular component after total hip arthroplasty (THA) has been treated with open and endoscopic IP tenotomy or acetabular component revision. This study describes the results of a consecutive series of patients treated with endoscopic IP tenotomy as a less invasive alternative. Twenty-eight patients with IP impingement after THA underwent endoscopic IP lengthening from 2012 to 2021 at a single-center academic institution. The follow-up of 24 of these patients was achieved with a mean follow-up of 7.6 months (range 1-28). Outcomes included the modified Harris Hip Score (mHHS), visual analog pain scale (VAS), satisfaction, component positioning and complications. Seventy-one percent of patients were satisfied or very satisfied after their operation. The median mHHS preoperatively was 57 (Interquartile range [IQR] 43-60) and postoperatively was 75 (IQR 66-92, P < 0.001). Clinically meaningful improvements in mHHS were seen in patients with VAS pain scores <5, cup prominence >8 mm, body mass index >30, and less than 2 years from their index THA. Two patients developed a deep infection 7 and 10 months postoperatively (neither related to the release), and one patient underwent open psoas release for persistent impingement. Endoscopic IP tenotomy is a safe and effective treatment for impingement after THA. Patients with cup prominence >8 mm, body mass index >30 and less than 2 years since their index THA may have more clinically meaningful improvements in pain and function.

11.
J Arthroplasty ; 38(12): 2526-2530.e1, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37595766

RESUMO

BACKGROUND: The Index of Concentration at the Extremes (ICE), a measure of geographic socioeconomic polarization, predicts several health outcomes but has not been evaluated concerning total knee arthroplasty (TKA). This study evaluates ICE as a predictor of post-TKA resource utilization. METHODS: Using the Healthcare Cost and Utilization Project's New York State database from 2016 to 2017, we retrospectively evaluated 57,426 patients ≥50 years undergoing primary TKA. The ICE values for extreme concentrations of income and race were calculated using United States Census Bureau data with the formula ICEi = (Pi-Di)/Ti where Pi, Di, and Ti are the number of households in the most privileged extreme, disadvantaged extreme, and total population in zip code i, respectively. Extremes of privilege and disadvantage were defined as ≥$150,000 versus <$25,000 for income and non-Hispanic White versus non-Hispanic Black for race. Association of ICE values, demographics, and comorbidities with 90-day readmission and 90-day emergency department (ED) visits was examined using multivariable analysis. RESULTS: Overall 90-day readmission and ED visit rates were 12.8% and 9.4%, respectively. On multivariable analysis, the lowest ICEIncome quintile (concentrated poverty) predicted 90-day readmission (odds ratio 1.17, 95% confidence interval 1.05 to 1.30, P = .005) and 90-day ED visit (odds ratio 1.22, 95% confidence interval 1.08 to 1.38, P = .001). The ICERace was not predictive of either outcome. CONCLUSION: Patients in communities with the lowest ICEIncome values use more inpatient and ED resources after primary TKA. Incorporating ICEIncome into risk-adjusted payment models may help align incentives for equitable care.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Humanos , Estados Unidos , Artroplastia do Joelho/efeitos adversos , Fatores de Risco , Estudos Retrospectivos , Etnicidade , Comorbidade , Artroplastia de Quadril/efeitos adversos , Readmissão do Paciente , Complicações Pós-Operatórias/etiologia
12.
J Arthroplasty ; 38(9): 1636-1638, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37207701

RESUMO

Orthopaedics has seen a rapid transition to value-based care. As we transition away from fee-for-service models, healthcare systems, groups, and surgeons are being asked to take on an increasing amount of risk. While on the surface risk may have a negative connotation, managing risk allows surgeons to maintain autonomy while taking on value-based care to the next level. The purpose of this paper, the first in a series of 2, is to walk through the impact that value-based care has had on musculoskeletal surgeons, to understand the continued movement healthcare is making into risk sharing models, and to introduce the concept of surgeon specialist-led care.


Assuntos
Procedimentos Ortopédicos , Ortopedia , Humanos , Atenção à Saúde , Planos de Pagamento por Serviço Prestado
13.
J Arthroplasty ; 38(6S): S246-S252, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36931358

RESUMO

BACKGROUND: This study evaluated the ability to achieve the targeted soft-tissue balance in terms of medio-lateral (ML) laxity and gap values when using a computer-assisted orthopedic surgery (CAOS) system featuring an intra-articular force-controlled distractor and assessed learning curves associated with the adoption of this technology. METHODS: The first 273 cases using this technology were reported without exclusions comparing 1) final ML laxity and 2) final average gap to their predefined targets. For both parameters, the signed and unsigned differentials were reported. The linear mixed model was used to evaluate laxity curve differences between surgeons. A cumulative sum control chart (CUSUM) was applied to assess surgeon learning curves regarding surgical time. RESULTS: Both the average signed ML laxity and gap differentials were neutral throughout the full arc of motion. Both the average unsigned ML laxity and gap differentials were linear. Signature of ML laxity and gap differential curves tended to be surgeon-specific. The CUSUM analyses of surgical times demonstrated either a short learning curve or the absence of a discernible learning pattern for surgeons. CONCLUSION: Data from all users involved with the pilot release of the balancing device were considered to capture variability in familiarity with the technique and learning curve cases were included. A high ability to achieve targeted gap balance throughout the arc of motion using the proposed method was observed.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Cirurgia Assistida por Computador , Humanos , Articulação do Joelho/cirurgia , Artroplastia do Joelho/métodos , Amplitude de Movimento Articular , Movimento (Física) , Osteoartrite do Joelho/cirurgia
14.
JAMA Surg ; 158(6): 603-608, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36947044

RESUMO

Importance: Surgical team communication is a critical component of operative efficiency. The factors underlying optimal communication, including team turnover, role composition, and mutual familiarity, remain underinvestigated in the operating room. Objective: To assess staff turnover, trainee involvement, and surgeon staff preferences in terms of intraoperative efficiency. Design, Setting, and Participants: Retrospective analysis of staff characteristics and operating times for all total joint arthroplasties was performed at a tertiary academic medical center by 5 surgeons from January 1 to December 31, 2018. Data were analyzed from May 1, 2021, to February 18, 2022. The study included cases with primary total hip arthroplasties (THAs) and primary total knee arthroplasties (TKAs) comprising all primary total joint arthroplasties performed over the 1-year study interval. Exposures: Intraoperative turnover among nonsurgical staff, presence of trainees, and presence of surgeon-preferred staff. Main Outcomes and Measures: Incision time, procedure time, and room time for each surgery. Multivariable regression analyses between operative duration, presence of surgeon-preferred staff, and turnover among nonsurgical personnel were conducted. Results: A total of 641 cases, including 279 THAs (51% female; median age, 64 [IQR, 56.3-71.5] years) and 362 TKAs (66% [238] female; median age, 68 [IQR, 61.1-74.1] years) were considered. Turnover among circulating nurses was associated with a significant increase in operative duration in both THAs and TKAs, with estimated differences of 19.6 minutes (SE, 3.5; P < .001) of room time in THAs and 14.0 minutes (SE, 3.1; P < .001) of room time in TKAs. The presence of a preferred anesthesiologist or surgical technician was associated with significant decreases of 26.5 minutes (SE, 8.8; P = .003) of procedure time and 12.6 minutes (SE, 4.0; P = .002) of room time, respectively, in TKAs. The presence of a surgeon-preferred vendor was associated with a significant increase in operative duration in both THAs (26.3 minutes; SE, 7.3; P < .001) and TKAs (29.6 minutes; SE, 9.6; P = .002). Conclusions and Relevance: This study found that turnover among operative staff is associated with procedural inefficiency. In contrast, the presence of surgeon-preferred staff may facilitate intraoperative efficiency. Administrative or technologic support of perioperative communication and team continuity may help improve operative efficiency.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Cirurgiões , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Estudos Retrospectivos , Salas Cirúrgicas
15.
J Arthroplasty ; 38(6S): S66-S70.e2, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36758842

RESUMO

BACKGROUND: End-stage knee osteoarthritis with retained periarticular hardware is a frequent scenario. Conversion total knee arthroplasty (TKA) leads to excellent outcomes, but poses unique challenges. The evidence supporting retention versus removal of hardware during TKA is controversial. METHODS: Patients who underwent TKA with prior hardware between January 2009 and December 2019 were identified. A total of 148 patients underwent TKA with prior hardware. The mean follow-up was 60 months (range, 24-223). Univariate and multivariable analyses were used to study correlations among factors and surgical-related complications, prosthesis failures, and functional outcomes. RESULTS: The complication rate was 28 of 148 (18.9%). The use of a quadriceps snips in addition to a medial parapatellar arthrotomy was associated with a higher complication (odds ratio: 20.7, P < .05), implant failures (odds ratio: 13.9, P < .05), and lower the Veterans Rand 12 Mental Score (VR-12 MS) (-14.8, P < .05). Hardware removal versus retention and use of single versus multiple incisions were not associated with complications or prosthesis failures. Removal of all hardware was associated with significantly higher (+7.3, P < .05) VR-12 MS compared to retention of all hardware. CONCLUSIONS: TKA with prior hardware was associated with more complications, implant failures, and lower VR-12 MS when a more constrained construct or quadriceps snip was performed. This probably reflects the level of difficulty of the procedure rather than the surgical approach used. Hardware removal or retention was not associated with complications or implant failures; however, removal rather than retention of all prior hardware is associated with increased general health outcomes. LEVEL OF EVIDENCE: IV, cohort without control.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Falha de Prótese , Sobrevivência , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/etiologia , Prótese do Joelho/efeitos adversos , Articulação do Joelho/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
16.
J Arthroplasty ; 38(5): 903-908, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36535440

RESUMO

BACKGROUND: As the number of primary total hip arthroplasty (THA) cases increase, so does the demand for revision operations. However, long-term follow-up data for revision THA is lacking. METHODS: A retrospective review was completed of patients who underwent revision THA at a single institution between January 2002 and October 2007 using a cementless modular stem. Patient demographic, clinical, and radiographic data was collected. Preoperative and postoperative patient-reported outcome scores were compared at a minimum of fourteen-year follow-up. RESULTS: Eighty-four patients (89 hips) with a median age of 69 years (range, 28 to 88) at operation were included. Indications for revision included aseptic loosening (84.2%), infection (12.4%), and periprosthetic fracture (3.4%). Twenty-two hips sustained at least 1 complication: intraoperative fracture (7.9%), dislocation (6.7%), prosthetic joint infection (4.5%), deep venous thrombosis (3.4%), and late periprosthetic fracture (2.2%). There were no modular junction complications. Eight patients underwent reoperations; only three involved the stem. Thirty-eight patients (45%) were deceased prior to final follow-up without known reoperations. Twenty-seven patients (32%) were lost to follow-up. Twenty-one patients (23%) were alive at minimum fourteen-year follow-up. Complete patient-reported outcomes were available for nineteen patients (range, 14 to 18.5 years of follow-up). Significant improvement was seen in UCLA activity, VR-12 physical, hip disability and osteoarthritis outcome score, joint replacement., and Harris Hip score pain and function scores. CONCLUSION: Challenges of long-term follow-up include patient migration, an unwillingness to travel for re-examination, medical comorbidities, advanced age, and death. The cementless modular revision stem demonstrated long-term clinical success and remains a safe and reliable option for complex revision operations.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Seguimentos , Prótese de Quadril/efeitos adversos , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Falha de Prótese
17.
Int Orthop ; 47(1): 117-124, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36224431

RESUMO

PURPOSE: Total hip arthroplasty (THA) in patients with small or unusual proximal femoral anatomy is challenging due to sizing issues, control of version, and implant fixation. The Wagner Cone is a monoblock, fluted, tapered stem with successful outcomes for these patients; however, there is limited information on subsidence, a common finding with cementless stems. METHODS: We retrospectively reviewed our cases using the modified Wagner Cone (Zimmer, Warsaw, IN) implanted over a 13-year period (2006-2019) in patients with small or abnormal proximal femoral anatomy. We performed 144 primary THAs in 114 patients using this prosthesis. Mean follow-up was 4.5 ± 3.4 years (range, 1-13 years). Common reasons for implantation were hip dysplasia (52%) and osteoarthritis in patients with small femoral proportions (22%). Analysis of outcomes included assessment of stem subsidence and stability. RESULTS: Survival was 98.6% in aseptic cases; revision-free survival was 97.9%. Femoral subsidence occurred in 84 cases (58%). No subsidence progressed after 3 months. Of those that subsided, the mean distance was 2.8 ± 2.0 mm. There was less subsidence in stems that stabilized prior to six weeks (2.2 ± 1.4 mm) compared to those that continued until 12 weeks (3.9 ± 1.6, p = 0.02). Harris Hip, UCLA, and WOMAC scores significantly improved from pre-operative evaluation (p < 0.001*, p < 0.003*, p ≪ 0.001*); there was no difference in outcome between patients with and without subsidence (p = 0.430, p = 0.228, p = 0.147). CONCLUSION: The modified Wagner Cone demonstrates excellent clinical outcomes in patients with challenging proximal femoral anatomy. Subsidence is minor, stops by 3 months, and does not compromise clinical outcome.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese , Reoperação , Fêmur/cirurgia , Falha de Prótese
18.
Ann Surg ; 277(3): e503-e512, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35129529

RESUMO

OBJECTIVE: The longitudinal assessment of physical function with high temporal resolution at a scalable and objective level in patients recovering from surgery is highly desirable to understand the biological and clinical factors that drive the clinical outcome. However, physical recovery from surgery itself remains poorly defined and the utility of wearable technologies to study recovery after surgery has not been established. BACKGROUND: Prolonged postoperative recovery is often associated with long-lasting impairment of physical, mental, and social functions. Although phenotypical and clinical patient characteristics account for some variation of individual recovery trajectories, biological differences likely play a major role. Specifically, patient-specific immune states have been linked to prolonged physical impairment after surgery. However, current methods of quantifying physical recovery lack patient specificity and objectivity. METHODS: Here, a combined high-fidelity accelerometry and state-of-the-art deep immune profiling approach was studied in patients undergoing major joint replacement surgery. The aim was to determine whether objective physical parameters derived from accelerometry data can accurately track patient-specific physical recovery profiles (suggestive of a 'clock of postoperative recovery'), compare the performance of derived parameters with benchmark metrics including step count, and link individual recovery profiles with patients' preoperative immune state. RESULTS: The results of our models indicate that patient-specific temporal patterns of physical function can be derived with a precision superior to benchmark metrics. Notably, 6 distinct domains of physical function and sleep are identified to represent the objective temporal patterns: ''activity capacity'' and ''moderate and overall activity (declined immediately after surgery); ''sleep disruption and sedentary activity (increased after surgery); ''overall sleep'', ''sleep onset'', and ''light activity'' (no clear changes were observed after surgery). These patterns can be linked to individual patients preopera-tive immune state using cross-validated canonical-correlation analysis. Importantly, the pSTAT3 signal activity in monocytic myeloid-derived suppressor cells predicted a slower recovery. CONCLUSIONS: Accelerometry-based recovery trajectories are scalable and objective outcomes to study patient-specific factors that drive physical recovery.


Assuntos
Benchmarking , Exercício Físico , Humanos , Monócitos , Exame Físico , Período Pós-Operatório
19.
J Arthroplasty ; 38(4): 706-712, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35598762

RESUMO

BACKGROUND: Excessive standing posterior pelvic tilt (PT), lumbar spine stiffness, low pelvic incidence (PI), and severe sagittal spinal deformity (SSD) have been linked to increased dislocation rates. We aimed to determine the prevalence of these 4 parameters in a cohort of unstable total hip arthroplasty (THA) patients and compare these to a large representative control population of primary THA patients. METHODS: Forty-eight patients with instability following primary THA were compared to a control cohort of 9414 THA patients. Lateral X-rays in standing and flexed-seated positions were used to assess PT and lumbar lordosis (LL). Computed tomography scans were used to measure PI and acetabular cup orientation. Thresholds for "at risk" spinopelvic parameters were standing posterior PT ≤ -15°, lumbar flexion (LLstand-LLseated) ≤ 20°, PI ≤ 41°, PI ≥ 70°, and SSD (PI-LLstand mismatch ≥ 20°). RESULTS: There were significant differences in mean spinopelvic parameters between the dislocating and control cohorts (P < .001). There were no differences in mean PI (58° versus 56°, respectively, P = .29) or prevalence of high and low PI between groups. 67% of the dislocating patients had one or more significant risk factors, compared to only 11% of the control. A total of 71% of the dislocating patients had cup orientations within the traditional safe zone. CONCLUSION: Excessive standing posterior PT, low lumbar flexion, and a severe SSD are more prevalent in unstable THAs. Pre-op screening for these parameters combined with appropriate planning and implant selection may help identify at risk patients and reduce the prevalence of dislocation.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Luxações Articulares , Lordose , Humanos , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/epidemiologia , Luxação do Quadril/etiologia , Prevalência , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Lordose/complicações , Lordose/cirurgia , Luxações Articulares/cirurgia , Fatores de Risco , Estudos Retrospectivos
20.
J Arthroplasty ; 38(2): 335-340, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36099937

RESUMO

BACKGROUND: Revision of both femoral and tibial components of a total knee arthroplasty (TKA) for aseptic loosening has favorable outcomes. Revision of only one loose component with retention of others has shorter operative time and lower cost; however, implant survivorship and clinical outcomes of these different operations are unclear. METHODS: Between January 2009 and December 2019, a consecutive cohort of revision TKA was reviewed. Univariate and multivariable analyses were used to study correlations among factors and surgical related complications, time to prosthesis failure, and functional outcomes (University of California Los Angeles, Knee Society functional, knee osteoarthritis and outcome score for joint replacement, Veterans RAND 12 (VR-12) physical, and VR-12 mental). RESULTS: A total of 238 patients underwent revision TKA for aseptic loosening. The mean follow-up time was 61 months (range 25 to 152). Ten of the 105 patients (9.5%) who underwent full revision (both femoral and tibial components) and 18 of the 133 (13.5%) who underwent isolated revision had subsequent prosthesis failure [Hazard ratio (HR) 0.67, P = .343]. The factor analysis of type of revision (full or isolated revision) did not demonstrate a significant difference between groups in terms of complications, implant failures, and times to failure. Metallosis was related to early time to failure [Hazard ratio 10.11, P < .001] and iliotibial band release was associated with more complications (Odds ratio 9.87, P = .027). Preoperative symptoms of instability were associated with the worst improvement in University of California Los Angeles score. Higher American Society of Anesthesiologists status and higher Charlson Comorbidity Index were related with worse VR-12 physical (-30.5, P = .008) and knee osteoarthritis and outcome score for joint replacement (-4.2, P = .050) scores, respectively. CONCLUSION: Isolated and full component revision TKA for aseptic loosening does not differ with respect to prosthesis failures, complications, and clinical results at 5 years. Poor American Society of Anesthesiologists status, increased comorbidities, instability, and a severe bone defect are related to worse functional improvement. LEVEL OF EVIDENCE: III, cohort with control.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Falha de Prótese , Osteoartrite do Joelho/complicações , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Reoperação/efeitos adversos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA