Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Magn Reson Chem ; 61(2): 73-82, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-33786881

RESUMO

Amphetamine and cathinone derivatives are abused recreationally due to the sense of euphoria they provide to the user. Methodologies for the rapid detection of the drug derivative present in a seized sample, or an indication of the drug class, are beneficial to law enforcement and healthcare providers. Identifying the drug class is prudent because derivatisation of these drugs, to produce regioisomers, for example, occurs frequently to circumvent global and local drug laws. Thus, newly encountered derivatives might not be present in a spectral library. Employment of benchtop nuclear magnetic resonance (NMR) could be used to provide rapid analysis of seized samples as well as identifying the class of drug present. Discrimination of individual amphetamine-, methcathinone-, N-ethylcathinone and nor-ephedrine-derived fluorinated and methylated regioisomers is achieved herein using qualitative automated 1 H NMR analysis and compared to gas chromatography-mass spectrometry (GC-MS) data. Two seized drug samples, SS1 and SS2, were identified to contain 4-fluoroamphetamine by 1 H NMR (match score median = 0.9933) and GC-MS (RRt = 5.42-5.43 min). The amount of 4-fluoroamphetamine present was 42.8%-43.4% w/w and 48.7%-49.2% w/w for SS1 and SS2, respectively, from quantitative 19 F NMR analysis, which is in agreement with the amount determined by GC-MS (39.9%-41.4% w/w and 49.0%-49.3% w/w). The total time for the qualitative 1 H NMR and quantitative 19 F NMR analysis is ~10 min. This contrasts to ~40 min for the GC-MS method. The NMR method also benefits from minimal sample preparation. Thus, benchtop NMR affords rapid, and discriminatory, analysis of the drug present in a seized sample.


Assuntos
Anfetamina , Efedrina , Efedrina/análise , Efedrina/química , Espectroscopia de Ressonância Magnética
2.
J Pharm Biomed Anal ; 219: 114950, 2022 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-35914505

RESUMO

Rapid analysis of surrendered or seized drug samples provides important intelligence for health (e.g. treatment or harm reduction), and custodial services. Herein, three in-situ techniques, GC-MS, 1H NMR and FT-IR spectroscopy, with searchable libraries, are used to analyse 318 samples qualitatively, using technique specific library-based searches, obtained over the period 24th - 29th August 2019. 259 samples were identified as consisting of a single component, of which cocaine was the most prevalent (n = 158). Median match scores for all three techniques were ≥ 0.84 and showed agreement except for metformin (n = 1), oxandrolone (identified as vitamin K by IR (n = 4)), diazepam (identified as zolpidem by FT-IR (n = 2)) and 2-Br-4,5-DMPEA (n = 1), a structural isomer of 2C-B identified as a polymer of cellulose (cardboard) by FT-IR. 51 samples were found to consist of two or more components, of which 49 were adulterated cocaine samples (45 binary and 4 tertiary samples). GC-MS identified all components present in the 49 adulterated cocaine samples, whereas IR identified only cocaine in 88 % of cases (adulterant only = 12 %). The breakdown for 1H NMR spectroscopy was all components identified (51 %), cocaine only (33 %), adulterant only (10 %), cocaine and one adulterant (tertiary mixtures only, 6 %).


Assuntos
Cocaína , Cocaína/análise , Cromatografia Gasosa-Espectrometria de Massas , Espectroscopia de Prótons por Ressonância Magnética , Espectroscopia de Infravermelho com Transformada de Fourier
3.
J Pharm Biomed Anal ; 216: 114798, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35561436

RESUMO

This study describes the first reported development of a rapid, generic gradient Ultra-High Performance Liquid Chromatography (UHPLC) methodology with targeted triple quadrupole MS/MS using electrospray positive ionisation to detect and unambiguously confirm the identity of 33 substituted 1, 2-diarylethamine (or diphenidine) derivatives in solid drug samples. The in-house synthesised library included a range of derivatives possessing either electron donating/withdrawing substituents, commonly included in combinatorial libraries, of varying size and lipophilicity on the phenyl ring. These test probes were used to investigate if their order of elution and that of their regioisomers were dependent on the position and type of the substituent on the phenyl ring. In addition, investigations into the retention mechanism of the diphenidines under reverse-phase UHPLC conditions were undertaken. Common adulterants found within seized bulk samples were assessed to prove that the methodology was specific, and the developed UHPLC-MS/MS (tG = 10 min) protocol was applied to confirm the identity of the psychoactive components within four seized bulk samples provided by law enforcement.


Assuntos
Piperidinas , Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão/métodos , Psicotrópicos/química , Espectrometria de Massas em Tandem/métodos
4.
J Pharm Biomed Anal ; 216: 114797, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35550280

RESUMO

Supercritical Fluid Chromatography (SFC-UV) employing a carbon dioxide (CO2) and 10 mM ammonium acetate in MeOH-water (95:5 v/v) gradient provides a rapid analysis (tG <10 min) of 31 novel, regioisomeric diphenidine-derived psychoactive substances, on a range of stationary phases of differing polarity. Medium to large selectivity differences between regioisomers, were observed on the acidic, neutral and basic SFC phases. For individual substituted ortho-, meta- and para-isomers, the same elution order was observed irrespective of the nature of the stationary phase. The acidic silica stationary phases yielded longer retention of the diphenidines via electrostatic attraction, whereas the basic phases resulted in shorter retention via electrostatic repulsion. SFC effected baseline separation of seven of the eight substituted groups of ortho-, meta- and para-diphenidines evaluated on a range of stationary phases. A simple silica phase achieved baseline separation of six of the regioisomeric substituted diphenidines. As the size of the halo-substituent increased, the resolution between ortho-/meta-isomers decreased, resulting in co-elution of the ortho- and meta-bromodiphenidines. Fluphenidines and chlorodiphenidines generated an elution order of meta- < ortho- < para- whereas an elution order switch was observed for the iodophenidines. This contrasted with RP-UHPLC where the elution order for the fluphenidines and iodophenidines was para- < ortho- < meta- and para- < meta- < ortho- respectively. An orthogonal elution order of diphenidines was demonstrated between the RP-UHPLC and SFC stationary phases due to the polarity differences between the separation modes. In general, hydrophilic compounds, which were poorly retained on a C18 reverse phase column, were well retained on SFC columns.


Assuntos
Cromatografia com Fluido Supercrítico , Dióxido de Carbono/química , Cromatografia com Fluido Supercrítico/métodos , Piperidinas , Dióxido de Silício
5.
Magn Reson Chem ; 58(12): 1151-1159, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-31945193

RESUMO

Piperazine-based drugs, such as N-benzylpiperazine (BZP), became attractive in the 2000s due to possessing effects similar to amphetamines. Herein, BZP, in addition to its pyridyl analogues, 2-, 3-, and 4-pyridylmethylpiperidine (2-PMP, 3-PMP, and 4-PMP respectively) was subjected to the hyperpolarisation technique Signal Amplification By Reversible Exchange (SABRE) in order to demonstrate the use of this technique to detect these piperazine-based drugs. Although BZP was not hyperpolarised via SABRE, 2-PMP, 3-PMP, and 4-PMP were, with the ortho- and meta-pyridyl protons of 4-PMP showing the largest enhancement of 313-fold and 267-fold, respectively, in a 1.4-T detection field, following polarisation transfer at Earth's magnetic field. In addition to the freebase, 4-PMP.3HCl was also appraised by SABRE and was found not to polarise, however, the addition of increasing equivalents of triethylamine (TEA) produced the freebase, with a maximum enhancement observed upon the addition of 3 equivalents of TEA. Further addition of TEA led to a reduction in the observed enhancement. SABRE was also employed to polarise 4-PMP.3HCl (~20% w/w) in a simulated tablet to demonstrate the forensic application of the technique (138-fold enhancement for the ortho-pyridyl protons). The amount of 4-PMP.3HCl present in the simulated tablet was quantified via NMR using D2 O as a solvent and compared well to complimentary gas chromatography-mass spectrometry data. Exchanging D2 O for CD3 OD as the solvent utilised for analysis resulted in a significantly lower amount of 4-PMP.3HCl being determined, thus highlighting safeguarding issues linked to drug abuse in relation to determining the amount of active pharmaceutical ingredient present.


Assuntos
Piperazina/análise , Espectroscopia de Ressonância Magnética , Estrutura Molecular , Piperazina/análogos & derivados
6.
ACS Omega ; 4(4): 7103-7112, 2019 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-31179411

RESUMO

An automated approach to the collection of 1H NMR (nuclear magnetic resonance) spectra using a benchtop NMR spectrometer and the subsequent analysis, processing, and elucidation of components present in seized drug samples are reported. An algorithm is developed to compare spectral data to a reference library of over 300 1H NMR spectra, ranking matches by a correlation-based score. A threshold for identification was set at 0.838, below which identification of the component present was deemed unreliable. Using this system, 432 samples were surveyed and validated against contemporaneously acquired GC-MS (gas chromatography-mass spectrometry) data. Following removal of samples which possessed no peaks in the GC-MS trace or in both the 1H NMR spectrum and GC-MS trace, the remaining 416 samples matched in 93% of cases. Thirteen of these samples were binary mixtures. A partial match (one component not identified) was obtained for 6% of samples surveyed whilst only 1% of samples did not match at all.

7.
Anal Bioanal Chem ; 408(29): 8467-8481, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27744478

RESUMO

The prevalence of new psychoactive substances (NPSs) in forensic casework has increased prominently in recent years. This has given rise to significant legal and analytical challenges in the identification of these substances. The requirement for validated, robust and rapid testing methodologies for these compounds is obvious. This study details the analysis of 13 synthesised diphenidine derivatives encountered in casework using presumptive testing, thin layer chromatography and gas chromatography-mass spectrometry (GC-MS). Specifically, the validated GC-MS method provides, for the first time, both a general screening method and quantification of the active components for seized solid samples, both in their pure form and in the presence of common adulterants. Graphical Abstract Chemical synthesis and forensic analysis of 13 diphenidine-derived new psychoactive substance(s).


Assuntos
Medicina Legal/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Piperidinas/análise , Psicotrópicos/análise , Calibragem , Cromatografia em Camada Fina , Medicina Legal/instrumentação , Limite de Detecção , Piperidinas/química , Psicotrópicos/química , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA