Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Magn Reson Imaging ; 111: 196-201, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38723783

RESUMO

PURPOSE: Development of a technique for measuring the mechanical properties of zygomaticus major (ZM) may aid advances in clinical treatments for correcting abnormal oral posture. The objective of this work was to demonstrate the feasibility of measuring the stiffness of ZM using an MR elastography technique that incorporates a custom local driver and a phase-gradient (PG) inversion. METHODS: 2D MRE investigations were performed for 3 healthy subjects using a vibration frequency of 90 Hz to test the prediction that the stiffness of ZM would be greater in the mouth-open compared to the mouth-closed position. MRE wave images were acquired along the long axis of ZM and processed using a 2D spatial-temporal directional filter applied in the direction of wave propagation along the long axis of the muscle. Stiffness measurements were obtained by applying the PG technique to a 1D-profile drawn in the phase image of the first harmonic of the wave images and a one-tailed paired t-test was used to compare the ZM stiffness between the two mouth postures (p < 0.05). RESULTS: The mean stiffness and standard deviation (SD) of ZM across the three participants in the mouth-closed and mouth-open postures was 6.75 kPa (SD 3.36 kPa) and 15.5 kPa (SD 5.15 kPa), respectively. Changes of ZM stiffness were significantly greater in the mouth-open than the mouth-closed posture (p = 0.038). CONCLUSION: The feasibility of using the PG MRE technique to measure stiffness changes in a small muscle such as ZM for different mouth postures has been demonstrated. Further investigations are required in a larger cohort of participants to investigate the sensitivity and reproducibility of the technique for potential clinical application as well as in health and beauty related studies.

2.
Med Phys ; 48(2): 781-790, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33294999

RESUMO

PURPOSE: A 7T magnetic resonance thermometry (MRT) technique was developed to validate the conversion factor between the system-measured transmitted radiofrequency (RF) power into a home-built RF wrist coil with the system-predicted SAR value. The conversion factor for a new RF coil developed for ultra high magnetic field MRI systems is used to ensure that regulatory limits on RF energy deposition in tissue, specifically the local 10g-averaged specific absorption rate (SAR10g ), are not exceeded. MRT can be used to validate this factor by ensuring that MRT-measured SAR values do not exceed those predicted by the system. METHODS: A 14-cm diameter high-pass birdcage RF coil was built to image the wrist at 7T. A high spatial and temporal resolution dual-echo gradient echo MRT technique, incorporating quasi-simultaneous RF-induced heating and temperature change measurements using the proton resonance frequency method, was developed. The technique allowed for high-temperature resolution measurements (~±0.1°C) to be performed every 20 s over a 4-min heating period, with high spatial resolution (2.56 mm3 voxel size) and avoiding phase discontinuities arising from severe magnetic susceptibility-induced B0 inhomogeneities. Magnetic resonance thermometry was performed on a phantom made from polyvinylpyrrolidone to mimic the dielectric properties of muscle tissue at 297.2 MHz. Temperature changes measured with MRT and four fiber optic temperature sensors embedded in the phantom were compared. Electromagnetic simulations of the coil and phantom were developed and validated via comparison of simulated and measured B1 + maps in the phantom. The position of maximum SAR within the coil was determined from simulations, and MRT was performed within a wrist-sized piece of meat positioned at that SAR hotspot location. MRT-measured and system-predicted SAR values for the phantom and meat were compared. RESULTS: Temperature change measurements from MRT matched closely to those from the fiber optic temperature sensors. The simulations were validated via close correlation between the simulated and MRT-measured B1 + and SAR maps. Using a coil conversion factor of 2 kg-1 , MRT-measured point-SAR values did not exceed the system-predicted SAR10g in either the uniform phantom or in the piece of meat mimicking the wrist located at the SAR hotspot location. CONCLUSIONS: A highly accurate MRT technique with high spatial and temporal resolution was developed. This technique can be used to ensure that system-predicted SAR values are not exceeded in practice, thereby providing independent validation of SAR levels delivered by a newly built RF wrist coil. The MRT technique is readily generalizable to perform safety evaluations for other RF coils at 7T.


Assuntos
Termometria , Punho , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Ondas de Rádio , Punho/diagnóstico por imagem
3.
Radiology ; 272(1): 241-51, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24635676

RESUMO

PURPOSE: To determine the feasibility of using real-time fluoroscopic tracking for bolus-chase magnetic resonance (MR) angiography of peripheral vasculature to image three stations from the aortoiliac bifurcation to the pedal arteries. MATERIALS AND METHODS: This prospective study was institutional review board approved and HIPAA compliant. Eight healthy volunteers (three men; mean age, 48 years; age range, 30-81 years) and 13 patients suspected of having peripheral arterial disease (five men; mean age, 67 years; age range, 47-81 years) were enrolled and provided informed consent. All subjects were imaged with the fluoroscopic tracking MR angiographic protocol. Ten patients also underwent a clinical computed tomographic (CT) angiographic runoff examination. Two readers scored the MR angiographic studies for vessel signal intensity and sharpness and presence of confounding artifacts and venous contamination at 35 arterial segments. Mean aggregate scores were assessed. The paired MR angiographic and CT angiographic studies also were scored for visualization of disease, reader confidence, and overall diagnostic quality and were compared by using a Wilcoxon signed rank test. RESULTS: Real-time fluoroscopic tracking performed well technically in all studies. Vessel segments were scored good to excellent in all but the following categories: For vessel signal intensity and sharpness, the abdominal aorta, iliac arteries, distal plantar arteries, and plantar arch were scored as fair to good; and for presence of confounding artifacts, the abdominal aorta and iliac arteries were scored as fair. The MR angiograms and CT angiograms did not differ significantly in any scoring category (reader 1: P = .50, .39, and .39; reader 2: P = .41, .61, and .33, respectively). CT scores were substantially better in 20% (four of 20) and 25% (five of 20) of the pooled evaluations for the visualization of disease and overall image quality categories, respectively, versus 5% (one of 20) for MR scores in both categories. CONCLUSION: Three-station bolus-chase MR angiography with real-time fluoroscopic tracking provided high-spatial-resolution arteriograms of the peripheral vasculature, enabled precise triggering of table motion, and compared well with CT angiograms.


Assuntos
Abdome/irrigação sanguínea , Meios de Contraste , Imageamento Tridimensional , Perna (Membro)/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Doenças Vasculares Periféricas/diagnóstico , Adulto , Idoso , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Compostos Organometálicos , Doenças Vasculares Periféricas/diagnóstico por imagem , Tomografia Computadorizada por Raios X
4.
J Magn Reson Imaging ; 34(1): 2-12, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21698702

RESUMO

Methods are described for generating 3D time-resolved contrast-enhanced magnetic resonance (MR) angiograms of the hands and feet. Given targeted spatial resolution and frame times, it is shown that acceleration of about one order of magnitude or more is necessary. This is obtained by a combination of 2D sensitivity encoding (SENSE) and homodyne (HD) acceleration methods. Image update times from 3.4-6.8 seconds are provided in conjunction with view sharing. Modular receiver coil arrays are described which can be designed to the targeted vascular region. Images representative of the technique are generated in the vasculature of the hands and feet in volunteers and in patient studies.


Assuntos
Angiografia/métodos , Meios de Contraste/farmacologia , Pé/patologia , Mãos/patologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Aceleração , Algoritmos , Pé/diagnóstico por imagem , Mãos/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Doença de Raynaud/patologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA