Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
J Arrhythm ; 40(3): 605-613, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38939791

RESUMO

Background: The Mt FUJI study was a multicenter, prospective, randomized, single-blind, controlled trial comparing delivery catheter-based and stylet-based right ventricular (RV) lead placement at the RV septum. This study extended the follow-up duration to 1 year after implantation. Methods: Seventy patients with pacemaker indications for atrioventricular block were randomly assigned to the delivery catheter and stylet groups. We compared the mid-term efficacy and safety between the two groups at 1 year after implantation. The primary outcome was the change in the left ventricular ejection fraction (LVEF), and the secondary outcomes were changes in brain natriuretic peptide (BNP) levels, lead parameters, paced QRS duration, and the incidence of adverse events. Results: At the 1-year follow-up, no significant differences were observed in the changes in the LVEF (+1.0% ± 8.6% vs. +3.1% ± 8.1%, p = .332), BNP levels (+8.0 [-11.1, 26.5] pg/mL vs. -8.7 [-15.3, 13.2] pg/mL, p = .193), or lead performance between the delivery catheter and stylet groups. The QRS duration was significantly shorter in the delivery catheter group than in the stylet group (128 ± 23 ms vs. 146 ± 17 ms, p < .001). All-cause death, hospitalization for heart failure, new development of atrial fibrillation, and pacing-induced cardiomyopathy occurred in seven patients in the delivery catheter group and five in the stylet group. Conclusion: The delivery catheter system was similarly useful and safe compared to the stylet system in the mid-term follow-up from the Mt FUJI trial. Further long-term evaluations are warranted.

2.
Cureus ; 16(4): e57967, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38738079

RESUMO

BACKGROUND: ECG interpretation is sometimes difficult due to baseline fluctuations and electrode detachments when placed on the subjects' front side, leading to misinterpretation of the rhythms and phases of the cardiac cycle. We aimed to compare the differences in the wave amplitudes and respiratory variations between conventional ECG electrode positioning on the front side of patients and an alternative position on the backs of patients. METHODS: Echocardiography was performed in 85 patients lying in the left lateral position. We attached the red electrode to the right clavicle, the yellow to the left clavicle, and the green to the left lateral abdomen on the front side of the patients; on the back, we attached the electrode to the right clavicle, the right upper posterior iliac spine, and the left upper posterior iliac spine. RESULTS: The ECG monitor amplitudes were greater on the front side compared to the back side, but the BF-breath values were smaller on the back side (6.0 pixels) compared to the front side (10.5 pixels, p<0.05). The P wave amplitude divided by the BF-breath on the back side was greater than that seen on the front side (2.8 vs. 1.8, p<0.05), whereas the QRS amplitude divided by the BF-breath was 15.0 and 16.3, respectively (p=ns). CONCLUSION: As an alternative to front-side ECG monitoring, electrodes placed on the back can help avoid misinterpretation of the ECG rhythms and the phases of the cardiac cycle due to respiration during echocardiography.

3.
Heart ; 110(14): 954-962, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38589224

RESUMO

BACKGROUND: Hypertrophic cardiomyopathy (HCM) is often concomitant with sleep-disordered breathing (SDB), which can cause adverse cardiovascular events. Although an appropriate approach to SDB prevents cardiac remodelling, detection of concomitant SDB in patients with HCM remains suboptimal. Thus, we aimed to develop a machine learning-based discriminant model for SDB in HCM. METHODS: In the present multicentre study, we consecutively registered patients with HCM and performed nocturnal oximetry. The outcome was a high Oxygen Desaturation Index (ODI), defined as 3% ODI >10, which significantly correlated with the presence of moderate or severe SDB. We randomly divided the whole participants into a training set (80%) and a test set (20%). With data from the training set, we developed a random forest discriminant model for high ODI based on clinical parameters. We tested the ability of the discriminant model on the test set and compared it with a previous logistic regression model for distinguishing SDB in patients with HCM. RESULTS: Among 369 patients with HCM, 228 (61.8%) had high ODI. In the test set, the area under the receiver operating characteristic curve of the discriminant model was 0.86 (95% CI 0.77 to 0.94). The sensitivity was 0.91 (95% CI 0.79 to 0.98) and specificity was 0.68 (95% CI 0.48 to 0.84). When the test set was divided into low-probability and high-probability groups, the high-probability group had a higher prevalence of high ODI than the low-probability group (82.4% vs 17.4%, OR 20.9 (95% CI 5.3 to 105.8), Fisher's exact test p<0.001). The discriminant model significantly outperformed the previous logistic regression model (DeLong test p=0.03). CONCLUSIONS: Our study serves as the first to develop a machine learning-based discriminant model for the concomitance of SDB in patients with HCM. The discriminant model may facilitate cost-effective screening tests and treatments for SDB in the population with HCM.


Assuntos
Cardiomiopatia Hipertrófica , Aprendizado de Máquina , Oximetria , Síndromes da Apneia do Sono , Humanos , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Masculino , Feminino , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/fisiopatologia , Pessoa de Meia-Idade , Idoso , Curva ROC , Adulto
5.
J Cardiovasc Electrophysiol ; 35(4): 802-810, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38409896

RESUMO

INTRODUCTION: The Mt. FUJI multicenter trial demonstrated that a delivery catheter system had a higher rate of successful right ventricular (RV) lead deployment on the RV septum (RVS) than a conventional stylet system. In this subanalysis of the Mt. FUJI trial, we assessed the differences in electrocardiogram (ECG) parameters during RV pacing between a delivery catheter system and a stylet system and their associations with the lead tip positions. METHODS: Among 70 patients enrolled in the Mt FUJI trial, ECG parameters, RV lead tip positions, and lead depth inside the septum assessed by computed tomography were compared between the catheter group (n = 36) and stylet group (n = 34). RESULTS: The paced QRS duration (QRS-d), corrected paced QT (QTc), and JT interval (JTc) were significantly shorter in the catheter group than in the stylet group (QRS-d: 130 ± 19 vs. 142 ± 15 ms, p = .004; QTc: 476 ± 25 vs. 514 ± 20 ms, p < .001; JTc: 347 ± 24 vs. 372 ± 17 ms, p < .001). This superiority of the catheter group was maintained in a subgroup analysis of patients with an RV lead tip position at the septum. The lead depth inside the septum was greater in the catheter group than in the stylet group, and there was a significant negative correlation between the paced QRS-d and the lead depth. CONCLUSION: Using a delivery catheter system carries more physiological depolarization and repolarization during RVS pacing and deeper screw penetration in the septum in comparison to conventional stylet system. The lead depth could have a more impact on the ECG parameters rather than the type of pacing lead.


Assuntos
Estimulação Cardíaca Artificial , Septo Interventricular , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Catéteres , Eletrocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Septo Interventricular/diagnóstico por imagem
7.
Radiol Cardiothorac Imaging ; 5(5): e230074, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38076596

RESUMO

Four-dimensional (4D) flow cardiac MRI can be used to assess hemodynamics in patients with hypertrophic obstructive cardiomyopathy (HOCM) undergoing alcohol septal ablation (ASA). However, to the best of the authors' knowledge, no study has reported on insufficient or successful ASA evaluated with 4D flow cardiac MRI in HOCM with multiple obstructions. This case report presents a 74-year-old female patient who was diagnosed with HOCM with left ventricular (LV) outflow tract obstruction and midventricular obstruction. Repeat ASA targeting the LV outflow tract the first time and the midventricle the second time was conducted. Four-dimensional flow cardiac MRI performed before ASA, after the first ASA, and after the second ASA showed serial changes in the flow pathway and acceleration at the midventricle. Supplemental material is available for this article. © RSNA, 2023.

8.
Europace ; 25(4): 1451-1457, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36794652

RESUMO

AIMS: Although the delivery catheter system for pacemaker-lead implantation is a new alternative to the stylet system, no randomized controlled trial has addressed the difference in right ventricular (RV) lead placement accuracy to the septum between the stylet and the delivery catheter systems. This multicentre prospective randomized controlled trial aimed to prove the efficacy of the delivery catheter system for accurate delivery of RV lead to the septum. METHODS AND RESULTS: In this trial, 70 patients (mean age 78 ± 11 years; 30 men) with pacemaker indications of atrioventricular block were randomized to the delivery catheter or the stylet groups. Right ventricular lead tip positions were assessed using cardiac computed tomography within 4 weeks of pacemaker implantation. Lead tip positions were classified into RV septum, anterior/posterior edge of the RV septal wall, and RV free wall. The primary endpoint was the success rate of RV lead tip placement to the RV septum. RESULTS: Right ventricular leads were implanted as per allocation in all patients. The delivery catheter group had higher success rate of RV lead deployment to the septum (78 vs. 50%; P = 0.024) and narrower paced QRS width (130 ± 19 vs. 142 ± 15 ms P = 0.004) than those in the stylet group. However, there was no significant difference in procedure time [91 (IQR 68-119) vs. 85 (59-118) min; P = 0.488] or the incidence of RV lead dislodgment (0 vs. 3%; P = 0.486). CONCLUSION: The delivery catheter system can achieve a higher success rate of RV lead placement to the RV septum and narrower paced QRS width than the stylet system. TRIAL REGISTRATION NUMBER: jRCTs042200014 (https://jrct.niph.go.jp/en-latest-detail/jRCTs042200014).


Assuntos
Estimulação Cardíaca Artificial , Septo Interventricular , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Estudos Prospectivos , Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração/diagnóstico por imagem , Septo Interventricular/diagnóstico por imagem , Catéteres , Eletrocardiografia/métodos
9.
J Nucl Cardiol ; 30(4): 1374-1381, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36547805

RESUMO

BACKGROUND: In transthyretin cardiac amyloidosis (ATTR-CA), 99mTc-pyrophosphate myocardial scintigraphy (99mTc-PYP) is a diagnostic tool that utilizes visual and quantitative evaluation. However, false positive cases can occur because of tracer accumulation in the blood. We investigated the effectiveness of the heart-to-mediastinum (H/M) ratio of 99mTc-PYP in ATTR-CA diagnosis. METHODS: We retrospectively included 164 patients who underwent 99mTc-PYP single-photon emission computed tomography/computed tomography between March 2019 and January 2022. The diagnostic accuracy of ATTR-CA was examined by the heart-to-contralateral lung (H/CL) and H/M ratio calculated at 3 hours post-tracer administration. RESULTS: After the exclusion of patients who did not undergo endomyocardial biopsy, 30 patients (15 each with ATTR-CA and without ATTR-CA) were included. The receiver operating characteristic curve used to distinguish ATTR-CA from non-ATTR-CA patients revealed an area under the curve of 0.986 and 0.943, respectively. A H/M ratio of > 1.41 identified ATTR-CA patients with a sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 100, 93.3, 93.3, and 100%, respectively. Conversely, an H/CL ratio of > 1.3 identified ATTR-CA patients with 100% sensitivity, 40.0% specificity, 62.5% PPV, and 100% NPV. CONCLUSION: The H/M ratio obtained at 3 hours post-injection has the potential to be a novel indicator for ATTR-CA.


Assuntos
Amiloidose , Cardiomiopatias , Humanos , Pirofosfato de Tecnécio Tc 99m , Pré-Albumina , Cardiomiopatias/diagnóstico por imagem , Mediastino , Estudos Retrospectivos , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
11.
Int Heart J ; 63(3): 623-626, 2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35569963

RESUMO

Implantation of a cardiac resynchronization therapy (CRT) device is usually scheduled in the compensated phase of heart failure; however, procedural safety may be sometimes disturbed in the decompensated phase. We report a case of a successful semi-urgent implantation of a CRT device temporary assisted with Impella in a patient with the decompensated phase of severe heart failure dependent on inotropic agents and who cannot maintain the supine position. Impella assistance with left ventricular (LV) unloading and maintenance of end-organ perfusion contributed to early recovery from acute heart failure. Furthermore, an acute effect of mechanical resynchronization by biventricular pacing plays an important role in weaning from the mechanical support or inotropic dependence. These mutual effects of mechanical support and CRT might contribute to a decrease in LV end-diastolic pressure and to a remarkable early recovery from a severely decompensated condition.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Humanos , Resultado do Tratamento
14.
PLoS One ; 16(9): e0257227, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34520495

RESUMO

OBJECTIVES: Reactive oxygen species generated by xanthine oxidoreductase (XOR) are associated with the progression of atherosclerosis. However, changes in plasma XOR (pXOR) activity after percutaneous coronary intervention (PCI) for stable coronary artery disease (CAD) remains unknown. METHODS: Herein, we compared the change in the pXOR activity in patients undergoing PCI with that in patients undergoing coronary angiography (CAG) and further evaluated the relation between changes in pXOR activity and in-hospital and long-term outcomes of patients undergoing PCI. The pXOR activity of 80 consecutive patients who underwent PCI and 25 patients who underwent CAG during the hospitalization was analyzed daily. The percentage changes from baseline regulated time interval was evaluated. RESULTS: We found that although pXOR activity decreased after PCI, and remained low until discharge, no significant changes were observed in patients undergoing CAG. Furthermore, among the patients undergoing PCI, those who experienced in-hospital adverse events, had a higher percentage of pXOR reduction 3 days after PCI. There was no association between these changes and long-term events. CONCLUSIONS: A significant change in pXOR activity was observed in patients undergoing PCI than in patients undergoing CAG, and there seems to be a correlation between the in-hospital outcomes and the percentage reduction from baseline in pXOR activity.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Intervenção Coronária Percutânea/efeitos adversos , Espécies Reativas de Oxigênio/metabolismo , Xantina Desidrogenase/metabolismo , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Ativação Enzimática , Feminino , Hospitais , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
15.
J Arrhythm ; 37(2): 448-449, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33850588

RESUMO

We report a case with a thrombus-like image on pulmonary valve detected by intracardiac echocardiography before transseptal puncture for atrial fibrillation (AF) ablation. The multimodality assessment provided diagnosis of the imaging artifact and exclusion from the harmful mass. This finding could be useful for a safety management of AF ablation and avoidance of an unnecessary interruption of the procedure.

16.
BMC Cardiovasc Disord ; 21(1): 198, 2021 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-33879058

RESUMO

BACKGROUND: The hemodynamics in the left ventricle (LV) and the ascending aorta (AAO) before and after alcohol septal ablation (ASA) in patients with hypertrophic obstructive cardiomyopathy (HOCM) is elucidated. Our objective was to evaluate the pattern changes in AAO and intra-LV flow assessed by four-dimensional (4D) flow magnetic resonance imaging (MRI) before and after ASA and to clarify the association between 4D flow MRI-derived hemodynamic characteristics and the peak pressure gradient (PPG) in patients with drug-refractory HOCM. METHODS: In this retrospective observational study, 11 patients with HOCM underwent 4D flow MRI before and a week after ASA. The 4D flow MRI included blood flow visualization and quantification using streamline images. The combined score of vortex and helix in AAO was analyzed. The duration and phase count of the AAO vortex or helix flow and the size of the intra-LV anterior vortex were quantified. The correlation between the changes in hemodynamics and the resting PPG at LV outflow tract was also analyzed. We used the paired t-test for the comparison between before and after ASA and the Pearson's correlation coefficient for the analysis. RESULTS: The combined score for the incidence of vortex and/or helix flow in AAO after ASA was significantly lower than that before ASA (1.45 ± 0.52 vs. 1.09 ± 0.30, p = 0.046). The duration (744 ± 291 ms vs. 467 ± 258 ms, p < 0.001) and phase count (14.8 ± 4.4 phases vs. 10.5 ± 5.8 phases, p < 0.001) of the vortex or helix flow in AAO were significantly decreased after ASA. The LV anterior vortex area after ASA was significantly larger than that before ASA (1628 ± 420 mm2 vs. 2974 ± 539 mm2, p = 0.009). The delta phase count of the AAO vortex or helix before and a week after ASA was significantly correlated with delta PPG before and a week after ASA (R = 0.79, p = 0.004) and with delta PPG before and 6 months after ASA (R = 0.83, p = 0.002). CONCLUSIONS: Lower vortex or helix flow in AAO and larger diastolic vortex flow in LV were observed after ASA, which suggests the possibility to detect the changes of aberrant hemodynamics in HOCM.


Assuntos
Técnicas de Ablação , Cardiomiopatia Hipertrófica/cirurgia , Etanol/uso terapêutico , Hemodinâmica , Imagem Cinética por Ressonância Magnética , Imagem de Perfusão do Miocárdio , Função Ventricular Esquerda , Idoso , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do Tratamento
17.
Int J Mol Sci ; 20(16)2019 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-31426560

RESUMO

Heart failure (HF) is a rapidly growing global public health problem. Since HF results in high mortality and re-hospitalization, new effective treatments are desired. Although it remains controversial, omega 3 polyunsaturated fatty acids (n-3 PUFAs), such as the eicosapentaenoic acid and docosahexaenoic acid, have been widely recognized to have benefits for HF. In a large-scale clinical trial regarding secondary prevention of HF by n-3 PUFA (GISSI-HF trial), the supplementation of n-3 PUFA significantly reduced cardiovascular mortality and hospitalization. Other small clinical studies proposed that n-3 PUFA potentially suppresses the ventricular remodeling and myocardial fibrosis, which thereby improves the ventricular systolic and diastolic function both in ischemic and non-ischemic HF. Basic investigations have further supported our understanding regarding the cardioprotective mechanisms of n-3 PUFA against HF. In these reports, n-3 PUFA has protected hearts through (1) anti-inflammatory effects, (2) intervention of cardiac energy metabolism, (3) modification of cardiac ion channels, (4) improvement of vascular endothelial response, and (5) modulation of autonomic nervous system activity. To clarify the pros and cons of n-3 PUFA on HF, we summarized recent evidence regarding the beneficial effects of n-3 PUFA on HF both from the clinical and basic studies.


Assuntos
Cardiotônicos/uso terapêutico , Ácidos Graxos Ômega-3/metabolismo , Insuficiência Cardíaca/prevenção & controle , Animais , Ensaios Clínicos como Assunto , Ácidos Graxos Ômega-3/química , Ácidos Graxos Ômega-3/uso terapêutico , Insuficiência Cardíaca/metabolismo , Humanos
18.
Naunyn Schmiedebergs Arch Pharmacol ; 392(8): 949-959, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30919008

RESUMO

Pinacidil, a nonselective ATP-sensitive K+ (KATP) channel opener, has cardioprotective effects for hypertension, ischemia/reperfusion injury, and arrhythmia. This agent abolishes early afterdepolarizations, delayed afterdepolarizations (DADs), and abnormal automaticity in canine cardiac ventricular myocytes. DADs are well known to be caused by the Na+/Ca2+ exchange current (INCX). In this study, we used the whole-cell patch-clamp technique and Fura-2/AM (Ca2+-indicator) method to investigate the effect of pinacidil on INCX in isolated guinea pig cardiac ventricular myocytes. In the patch-clamp study, pinacidil enhanced INCX in a concentration-dependent manner. The half-maximal effective concentration values were 23.5 and 23.0 µM for the Ca2+ entry (outward) and Ca2+ exit (inward) components of INCX, respectively. The pinacidil-induced INCX increase was blocked by L-NAME, a nitric oxide (NO) synthase inhibitor, by ODQ, a soluble guanylate cyclase inhibitor, and by KT5823, a cyclic guanosine monophosphate (cGMP)-dependent protein kinase (PKG) inhibitor, but not by N-2-mercaptopropyonyl glycine (MPG), a reactive oxygen species (ROS) scavenger. Glibenclamide, a nonselective KATP channel inhibitor, blocked the pinacidil-induced INCX increase, while 5-HD, a selective mitochondria KATP channel inhibitor, did not. In the Fura-2/AM study pinacidil also enhanced intracellular Ca2+ concentration, which was inhibited by L-NAME, ODQ, KT5823, and glibenclamide, but not by MPG and 5-HD. Sildenafil, a phosphodiesterase 5 inhibitor, increased further the pinacidil-induced INCX increase. Sodium nitroprusside, a NO donor, also increased INCX. In conclusion, pinacidil may stimulate cardiac Na+/Ca2+ exchanger (NCX1) by opening plasma membrane KATP channels and activating the NO/cGMP/PKG signaling pathway.


Assuntos
Proteínas Quinases Dependentes de GMP Cíclico , GMP Cíclico , Canais KATP/agonistas , Miócitos Cardíacos/efeitos dos fármacos , Óxido Nítrico , Pinacidil/farmacologia , Transdução de Sinais/efeitos dos fármacos , Trocador de Sódio e Cálcio/metabolismo , Animais , Antioxidantes/farmacologia , Cobaias , Ventrículos do Coração/citologia , Ventrículos do Coração/metabolismo , Miócitos Cardíacos/metabolismo , Técnicas de Patch-Clamp , Pinacidil/antagonistas & inibidores , Estimulação Química
20.
J Mol Cell Cardiol ; 121: 103-106, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29981304

RESUMO

BACKGROUND: Hypertension promotes cardiac hypertrophy which finally leads to cardiac dysfunction. Although aberrant mitochondrial dynamics is known to be a relevant contributor of pathogenesis in heart disease, little is known about the relationship between mitochondrial dynamics and cardiac hypertrophy. We investigated the pathophysiological roles of Dynamin-related protein1 (Drp1, a mitochondrial fission protein) on the hypertensive cardiac hypertrophy. METHODS & RESULTS: Dahl salt-sensitive rats were fed with a low-salt (0.3% NaCl) or a high-salt (8% NaCl) chow to promote hypertension with and without administration of mdivi1 (an inhibitor of Drp1: 1 mg/kg/every alternative day), and then the hypertensive cardiac hypertrophy was assessed. High-salt fed rats exhibited left ventricular hypertrophy (LVH), myocytes hypertrophy, and cardiac fibrosis, and mdivi-1 suppressed them without alteration of the blood pressure. Mdivi1 also reduced ROS production by hypertension, which subsequently suppressed the Ca2+-activated protein phosphatase calcineurin and Ca2+/calmodulin-dependent kinase II (CaMKII). CONCLUSIONS: Our results suggest that Drp1 contributes to the pathogenesis of hypertensive cardiac hypertrophy via ROS production and the Drp1 suppression may be effective to prevent the hypertensive cardiac hypertrophy.


Assuntos
Cardiomegalia/genética , Dinaminas/genética , Hipertensão/genética , Hipertrofia Ventricular Esquerda/genética , Animais , Pressão Sanguínea/efeitos dos fármacos , Pressão Sanguínea/genética , Cardiomegalia/tratamento farmacológico , Cardiomegalia/patologia , Dinaminas/antagonistas & inibidores , Humanos , Hipertensão/induzido quimicamente , Hipertensão/tratamento farmacológico , Hipertensão/patologia , Hipertrofia Ventricular Esquerda/induzido quimicamente , Hipertrofia Ventricular Esquerda/tratamento farmacológico , Hipertrofia Ventricular Esquerda/patologia , Masculino , Dinâmica Mitocondrial/efeitos dos fármacos , Dinâmica Mitocondrial/genética , Miócitos Cardíacos/efeitos dos fármacos , Ratos , Ratos Endogâmicos Dahl , Cloreto de Sódio/toxicidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA