Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Cureus ; 16(4): e58356, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38756279

RESUMO

We experienced a case of bilateral corneal thinning during the oral taking of S-1, a combination anti-cancer drug of tegafur, gimeracil, and oteracil-potassium. A 69-year-old man was prescribed oral S-1 for the treatment of duodenal papilla adenocarcinoma and intraductal papillary mucinous neoplasm. However, he developed a decrease in visual acuity in both eyes after three cycles of S-1 oral taking, and ophthalmic examination revealed corneal thinning exceeding 100 µm and an increase in high-order irregularity of cornea in both eyes. After one month after discontinuation of S-1, his visual acuity and corneal thickness returned to its previous levels. Besides corneal ulcers and perforations, corneal thinning can be recognized as a potential corneal side effect necessitating monitoring during S-1 treatment.

2.
Am J Ophthalmol Case Rep ; 33: 102008, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38374947

RESUMO

Purpose: This study aims to present two different types of giant bleb formation following Ahmed Glaucoma Valve (AGV) implantation: an anterior enlarged giant bleb and a posterior enlarged giant bleb. Observations: In Case 1, a 70-year-old Japanese male underwent AGV implantation for neovascular glaucoma in his right eye (OD). Preoperatively, the patient's intraocular pressure (IOP) and best corrected visual acuity (BCVA) were 23 mmHg and 0.6, respectively, OD, while using 3 antiglaucoma topical medications. Two months post-surgery, the patient began experiencing double vision. Slit lamp evaluation revealed no abnormalities, IOP and BCVA were 24.0 mmHg and 0.8, respectively, OD. A posteriorly enlarged bleb in the superotemporal quadrant OD was found to be causing displacement on T2-weighted orbital MRI. The patient underwent surgical excision of the anterior bleb wall. By three weeks post-surgery, the double vision resolved; IOP and BCVA were 17 mmHg and 0.7, respectively, and a normal bleb in the slit lamp evaluation was identified OD. In Case 2, a 10-year-old Japanese female underwent AGV implantation for childhood glaucoma associated with congenital cataract OD. Preoperatively, IOP and BCVA were 30 mmHg and 0.5, respectively, OD, while using 3 antiglaucoma topical medications. She underwent pars plana vitrectomy (PPV) in addition to AGV implantation. Seven months post-surgery, slip lamp evaluation revealed an anteriorly enlarged giant bleb that only cause her a cosmetic concern. Conclusions and Importance: There are two types of giant bleb formation following AGV implantation based on the direction of the enlargement: an anterior enlarged giant bleb and a posterior enlarged giant bleb. The introduction of this classification contribute to better understanding and management of this unusual surgical complication.

3.
Cureus ; 15(10): e47356, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38022219

RESUMO

We report a case of PreserFlo MicroShunt (PFM) dislocation following a postsurgical needling procedure. A 58-year-old woman underwent PFM implantation for exfoliation glaucoma in her left eye (OS). There were no intraoperative complications. Preoperatively, her best-corrected visual acuity (BCVA) was 0.6, and her intraocular pressure (IOP) was 25 mmHg with three antiglaucoma medications in the OS. On postoperative day 21, the IOP was 21 mmHg OS, and the filtration bleb had shrunk. A needling procedure was performed using a sharp 26-gauge needle to lower the IOP. On postoperative day 29, the BCVA was 0.02, and the IOP was 60 mmHg OS. Gonioscopy revealed no device tip in the anterior chamber, and peripheral anterior synechia was observed at the site of PFM insertion. Anterior segment optical coherence tomography showed a dislocated device in the subconjunctival space. On postoperative day 35, the dislocated PFM was removed, and a new device was inserted. Following the reoperation, no further complications were observed, and bleb formation was obtained. In conclusion, like other glaucoma filtering surgeries, PFM may require postsurgical needling procedures. Needling procedures may cause PFM dislocation and IOP rise, resulting in the requirement for further IOP-reducing procedures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA