Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Lancet ; 403(10445): 2695-2708, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38795719

RESUMO

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Lancet ; maio.2024.
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1555077

RESUMO

BACKGROUND Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1•5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2­4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10•44% and assuming an event rate of 26•10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80•0 years (SD 5•7) for those treated with the Myval THV and 80•4 years (5•4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2•6% [IQR 1•7­4•0] vs contemporary 2•6% [1•7­4•0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of ­2•3% (one-sided upper 95% CI 3•8, pnon-inferiority<0•0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days.

3.
Lancet ; 402(10419): 2317-2325, 2023 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-37972628

RESUMO

BACKGROUND: Calcific aortic stenosis is commonly treated using surgical or transcatheter aortic valve replacement; however, many patients are not considered suitable candidates for these interventions due to severe comorbidities and limited life expectancy. As such, non-invasive therapies might offer alternative therapeutic possibilities in these patients. This study aimed to assess the safety of non-invasive ultrasound therapy and its ability to improve valvular function by softening calcified valve tissue. METHODS: This prospective, multicentre, single-arm series enrolled 40 adult patients with severe symptomatic aortic valve stenosis at three hospitals in France, the Netherlands, and Serbia between March 13, 2019, and May 8, 2022. Patients were treated with transthoracically delivered non-invasive ultrasound therapy. Follow-ups were scheduled at 1, 3, 6, 12, and 24 months. The primary endpoints were procedure-related deaths within 30 days and improved valve function. We report the 6-month data. This study is registered at ClinicalTrials.gov, NCT03779620 and NCT04665596. FINDINGS: 40 high-risk patients with a mean Society of Thoracic Surgeons score of 5·6% (SD 4·4) and multiple severe comorbidities were included. The primary endpoint, procedure-related mortality, did not occur; furthermore, no life-threatening or cerebrovascular events were reported. Improved valve function was confirmed up to 6 months, reflected by a 10% increase in mean aortic valve area from 0·58 cm2 (SD 0·19) at baseline to 0·64 cm2 (0·21) at follow-up (p=0·0088), and a 7% decrease in mean pressure gradient from 41·9 mm Hg (20·1) to 38·8 mm Hg (17·8; p=0·024). At 6 months, the New York Heart Association score had improved or stabilised in 24 (96%) of 25 patients, and the mean Kansas City Cardiomyopathy Questionnaire score had improved by 33%, from 48·5 (SD 22·6) to 64·5 (21·0). One serious procedure-related adverse event occurred in a patient who presented with a transient decrease in peripheral oxygen saturation. Non-serious adverse events included pain, discomfort during treatment, and transient arrhythmias. INTERPRETATION: This novel, non-invasive ultrasound therapy for calcified aortic stenosis proved to be safe and feasible. FUNDING: Cardiawave.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Terapia por Ultrassom , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Neth Heart J ; 31(12): 489-499, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37910336

RESUMO

OBJECTIVE: The importance of revascularisation of significant coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI) is unclear. Despite the lack of randomised controlled trials comparing different revascularisation strategies, guidelines currently recommend percutaneous coronary intervention (PCI) in patients with significant proximal CAD undergoing TAVI. METHODS: In this systematic review and meta-analysis, a systematic search was conducted to identify studies comparing TAVI with and without PCI in patients with significant CAD on pre-TAVI coronary angiography. Endpoints were all-cause mortality, cardiac death, stroke, myocardial infarction and major bleeding. RESULTS: In total, 14 studies were included, involving 3838 patients, of whom 1806 (47%) underwent PCI before TAVI. All-cause mortality did not differ significantly between TAVI with and without preceding PCI at 30 days, 1 year and > 1 year. There were no significant differences in risk of cardiac death, stroke or myocardial infarction between the groups. However, TAVI performed with PCI resulted in a higher risk of major bleeding within 30 days after TAVI (odds ratio: 0.66; 95% confidence interval: 0.46-0.94). CONCLUSION: This systematic review and meta-analysis showed no significant differences in clinical outcomes between patients with concomitant significant CAD who were treated with TAVI with and without preceding PCI at both short- and long-term follow-up. However, there was a higher risk of major bleeding at 30 days in patients undergoing TAVI with preceding PCI. In the context of serious risk of bias in the included studies, results of randomised controlled trials are warranted.

5.
EuroIntervention ; 19(9): 766-771, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37605804

RESUMO

About one-third of patients undergoing transcatheter aortic valve implantation (TAVI) use oral anticoagulants (OAC), mainly due to atrial fibrillation. General guidelines advise interrupting OAC in patients with a high risk of bleeding undergoing interventions. However, preliminary observational data suggest that the continuation of OAC during TAVI is safe and may reduce the risk of periprocedural thromboembolic events. The Periprocedural Continuation Versus Interruption of Oral Anticoagulant Drugs During Transcatheter Aortic Valve Implantation (POPular PAUSE TAVI) is a multicentre, randomised clinical trial with open-label treatment and blinded endpoint assessment. Patients are randomised 1:1 to periprocedural continuation versus interruption of OAC and are stratified for vitamin K antagonist or direct oral anticoagulant use. The primary endpoint is a composite of cardiovascular mortality, all stroke, myocardial infarction, major vascular complications and type 2-4 bleeding within 30 days after TAVI, according to the Valve Academic Research Consortium-3 criteria. Secondary endpoints include separate individual and composite outcomes, quality of life and cost-effectiveness. Since continuation of OAC is associated with the ancillary benefit that it simplifies periprocedural management, the primary outcome is first analysed for non-inferiority; if non-inferiority is proven, superiority will be tested. Recruitment started in November 2020, and the trial will continue until a total of 858 patients have been included and followed for 90 days. In summary, POPular PAUSE TAVI is the first randomised clinical trial to assess the safety and efficacy of periprocedural continuation versus interruption of OAC in patients undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Qualidade de Vida , Anticoagulantes/uso terapêutico , Hemorragia , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
6.
Cardiol Res ; 14(4): 291-301, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37559713

RESUMO

Background: Drug-eluting stents (DESs) based on biodegradable polymers (BPs) have been introduced to reduce the risk for late and very late stent thrombosis (ST), which were frequently observed with earlier generations of DES designs based on durable polymers (DPs); however, randomized controlled trials on these DES designs are scarce. The meriT-V trial is a randomized, active-controlled, non-inferiority trial with a prospective, multicenter design that evaluated the 2-year efficacy of a novel third-generation, ultra-thin strut, BP-based BioMime sirolimus-eluting stent (SES) versus the DP-based XIENCE everolimus-eluting stent (EES) for the treatment of de novo lesions. Methods: The meriT-V is a randomized trial that enrolled 256 patients at 15 centers across Europe and Brazil. Here, we report the outcomes of the extended follow-up period of 2 years. The randomization of enrolled patients was in a 2:1 ratio; the enrolled patients received either the BioMime SES (n = 170) or the XIENCE EES (n = 86). The three-point major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction (MI), or ischemia-driven target vessel revascularization (ID-TVR), was considered as the composite safety and efficacy endpoint. Ischemia-driven target lesion revascularization (ID-TLR) was evaluated as well as the frequency of definite/probable ST, based on the first Academic Research Consortium definitions. Results: The trial had a 2-year follow-up completion rate of 98.44% (n = 252/256 patients), and the clinical outcomes assessment showed a nonsignificant difference in the cumulative rate of three-point MACE between both arms (BioMime vs. XIENCE: 7.74% vs. 9.52%, P = 0.62). Even the MI incidences in the BioMime arm were insignificantly lower than those of the XIENCE arm (1.79% vs. 5.95%, P = 0.17). Late ST was observed in 1.19% cases of the XIENCE arm, while there were no such cases in the BioMime arm (P = 0.16). Conclusions: The objective comparisons between the novel BP-based BioMime SES and the well-established DP-based XIENCE EES in this randomized controlled trial show acceptable outcomes of both the devices in the cardiac deaths, MI, ID-TVR, and ST. Moreover, since there were no incidences of cardiac death in the entire study sample over the course of 2 years, we contend that the findings of the study are highly significant for both these DES designs. In this preliminary comparative trial, the device safety of BioMime SES can be affirmed to be acceptable, considering the lower three-point MACE rate and absence of late ST in the BioMime arm over the 2-year period.

7.
Cardiol Res. ; 14(4): 291-301, ago.2023. ilus
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1525284

RESUMO

BACKGROUND: Drug-eluting stents (DESs) based on biodegradable polymers (BPs) have been introduced to reduce the risk for late and very late stent thrombosis (ST), which were frequently observed with earlier generations of DES designs based on durable polymers (DPs); however, randomized controlled trials on these DES designs are scarce. The meriT-V trial is a randomized, active-controlled, non-inferiority trial with a prospective, multicenter design that evaluated the 2-year efficacy of a novel third-generation, ultra-thin strut, BP-based BioMime sirolimus-eluting stent (SES) versus the DP-based XIENCE everolimus-eluting stent (EES) for the treatment of de novo lesions. METHODS: The meriT-V is a randomized trial that enrolled 256 patients at 15 centers across Europe and Brazil. Here, we report the outcomes of the extended follow-up period of 2 years. The randomization of enrolled patients was in a 2:1 ratio; the enrolled patients received either the BioMime SES (n = 170) or the XIENCE EES (n = 86). The three-point major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction (MI), or ischemia-driven target vessel revascularization (ID-TVR), was considered as the composite safety and efficacy endpoint. Ischemia-driven target lesion revascularization (ID-TLR) was evaluated as well as the frequency of definite/probable ST, based on the first Academic Research Consortium definitions. RESULTS: The trial had a 2-year follow-up completion rate of 98.44% (n = 252/256 patients), and the clinical outcomes assessment showed a nonsignificant difference in the cumulative rate of three-point MACE between both arms (BioMime vs. XIENCE: 7.74% vs. 9.52%, P = 0.62). Even the MI incidences in the BioMime arm were insignificantly lower than those of the XIENCE arm (1.79% vs.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doenças Cardiovasculares , Everolimo
8.
Rev Esp Cardiol (Engl Ed) ; 76(11): 872-880, 2023 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36898524

RESUMO

INTRODUCTION AND OBJECTIVES: No comparisons have been published yet regarding the newest iteration of balloon- and self-expandable transcatheter heart valves for the treatment of bicuspid aortic valve (BAV) stenosis. METHODS: Multicenter registry of consecutive patients with severe BAV stenosis treated with balloon-expandable transcatheter heart valves (Myval and SAPIEN 3 Ultra, S3U) or self-expanding Evolut PRO+(EP+). TriMatch analysis was carried out to minimize the impact of baseline differences. The primary endpoint of the study was 30-day device success, and the secondary endpoints were the composite and individual components of early safety at 30 days. RESULTS: A total of 360 patients (age 76.6±7.6 years, 71.9% males) were included: 122 Myval (33.9%), 129 S3U (35.8%), and 109 EP+(30.3%). The mean STS score was 3.6±1.9%. There were no cases of coronary artery occlusion, annulus rupture, aortic dissection, or procedural death. The primary endpoint of device success at 30 days was significantly higher in the Myval group (Myval: 100%; S3U: 87.5%; and EP+: 81.3%), mainly due to higher residual aortic gradients with S3U and greater≥moderate aortic regurgitation (AR) with EP+. No significant differences were found in the unadjusted rate of pacemaker implantation. CONCLUSIONS: In patients with BAV stenosis deemed unsuitable for surgery, Myval, S3U and EP+showed similar safety but balloon-expandable Myval had better gradients than S3U, and both balloon-expandable devices had lower residual AR than EP+, suggesting that, taking into consideration the patient-specific risks, any of these devices can be selected with optimal outcomes.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Constrição Patológica , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Desenho de Prótese
9.
Eur Heart J Qual Care Clin Outcomes ; 9(4): 417-426, 2023 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35876646

RESUMO

BACKGROUND: Multisite artery disease is considered a 'malignant' type of atherosclerotic disease associated with an increased cardiovascular risk, but the impact of multisite artery disease on clinical outcomes after percutaneous coronary intervention (PCI) is unknown. METHODS: Patients enrolled in the large, prospective e-Ultimaster study were grouped into (1) those without known prior vascular disease, (2) those with known single-territory vascular disease, and (3) those with known two to three territories (i.e coronary, cerebrovascular, or peripheral) vascular disease (multisite artery disease). The primary outcome was coronary target lesion failure (TLF), defined as the composite of cardiac death, target vessel-related myocardial infarction, and clinically driven target lesion revascularization at 1-year. Inverse propensity score weighted (IPSW) analysis was performed to address differences in baseline patient and lesion characteristics. RESULTS: Of the 37 198 patients included in the study, 62.3% had no prior known vascular disease, 32.6% had single-territory vascular disease, and 5.1% had multisite artery disease. Patients with known vascular disease were older and were more likely to be men and to have more co-morbidities. After IPSW, the TLF rate incrementally increased with the number of diseased vascular beds (3.16%, 4.44%, and 6.42% for no, single, and multisite artery disease, respectively, P < 0.01 for all comparisons). This was also true for all-cause death (2.22%, 3.28%, and 5.29%, P < 0.01 for all comparisons) and cardiac mortality (1.26%, 1.91%, and 3.62%, P ≤ 0.01 for all comparisons). CONCLUSIONS: Patients with previously known vascular disease experienced an increased risk of adverse cardiovascular events and mortality post-PCI. This risk is highest among patients with multisite artery disease.Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02188355.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Masculino , Humanos , Feminino , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento , Sistema de Registros , Artérias
10.
Eur Heart J Cardiovasc Imaging ; 24(5): 687-693, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-36342269

RESUMO

AIMS: To study if any qualitative or quantitative optical coherence tomography (OCT) variables in combination with thin cap fibroatheroma (TCFA) patients could improve the identification of lesions at risk for future major adverse cardiac events (MACEs). METHODS AND RESULTS: From the combined optical coherence tomography morphologic and fractional flow reserve hemodynamic assessment of non- culprit lesions to better predict adverse event outcomes in diabetes mellitus patients: COMBINE (OCT-FFR) trial database (NCT02989740), we performed a detailed assessment OCT qualitative and quantitative variables in TCFA carrying diabetes mellitus (DM) patients with vs. without MACE during follow-up. MACEs were defined as a composite of cardiac death, target vessel myocardial infarction, clinically driven target lesion revascularization, and hospitalization for unstable angina. From the 390 fractional flow reserve (FFR)-negative DM patients, 98 (25.2%) had ≥1 OCT-detected TCFA, of which 13 (13.3%) had MACE and 85 (86.7%) were event-free (non-MACE). The baseline characteristics were similar between both groups; however, a smaller minimal lumen area (MLA) and lower mean FFR value were observed in MACE group (1.80 vs. 2.50 mm2, P = 0.01, and 0.85 vs. 0.89, P = 0.02, respectively). Prevalence of healed plaque (HP) was higher in the MACE group (53.85 vs. 21.18%, P = 0.01). TCFA were predominantly located proximal to the MLA. TCFA area was smaller in the MACE group, while no difference was observed regarding the lesion area. CONCLUSION: Within TCFA carrying patients, a smaller MLA, lower FFR values, and TCFA location adjacent to a HP were associated with future MACE. Carpet-like measured lesion area surface was similar, while the TCFA area was smaller in the MACE arm, and predominantly located proximal to the MLA.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Placa Aterosclerótica , Humanos , Placa Aterosclerótica/patologia , Tomografia de Coerência Óptica/métodos , Angina Instável , Vasos Coronários/patologia , Doença da Artéria Coronariana/patologia , Valor Preditivo dos Testes , Angiografia Coronária
11.
J Interv Cardiol ; 2022: 3139476, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36320718

RESUMO

Objective: In TAVR, area sizing is used for balloon-expandable (BE) valves, whereas self-expanding valves are sized to annulus perimeter. For BE valves, this seems illogical: these frames force a circular shape even on an ellipsoid annulus. This can potentially lead to relative undersizing when area sizing is being applied. We developed a perimeter-based sizing algorithm to evaluate the safety and feasibility of perimeter sizing for the Myval BE valve. Methods: In this prospective single-center study, 60 patients with severe aortic stenosis treated with the Myval BE valve were included. Perimeter sizing was used with limited oversizing of 3.7% ± 1.3% compared to the annulus perimeter. After TAVR, clinical outcomes were evaluated at 30 days and 1 year. An echocardiographic follow-up took place at 30 days. Results: At 30 days, the need for PPI and stroke occurred in 2% and 3% of the patients, respectively. Moreover, cardiac death and moderate-severe PVL were absent. At 1-year, cardiac death and stroke were observed in 3% and 8% of the patients, respectively. In 33.3% of the patients, a larger valve size was implanted compared to the valve size calculated by area sizing. Conclusions: Perimeter sizing with the Myval BE valve leads to substantial use of larger valve sizes and favorable clinical outcomes, with low PPI and the absence of significant PVL. A randomized controlled trial is being planned to prove the superiority of this alternative sizing method.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Projetos Piloto , Estudos Prospectivos , Tomografia Computadorizada Multidetectores/métodos , Acidente Vascular Cerebral/etiologia , Morte , Desenho de Prótese , Resultado do Tratamento
12.
Clin Cardiol ; 45(12): 1211-1219, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36072999

RESUMO

BACKGROUND: Elderly patients with ST-elevation myocardial infarction (STEMI) who undergo percutaneous coronary intervention (PCI) are usually excluded from major trials. HYOPTHESIS: This study sought to assess 1-year clinical outcomes following PCI with a drug-eluting stent in patients older than 80 years old with STEMI. METHODS: The large all-comer, multicontinental e-ULTIMASTER registry included 7507 patients with STEMI who underwent PCI using the Ultimaster stent. The primary clinical endpoint was 1-year target lesion failure, a composite of cardiac death (CD), target vessel-related myocardial infarction (TV-MI), or clinically driven target lesion revascularization (CD-TLR). RESULTS: There were 457 (6.1%) patients in the elderly group (≥80 years old) that were compared to 7050 (93.9%) patients <80 years. The elderly patients included more female patients and had significantly more comorbidities and had more complex coronary anatomy. The primary endpoint occurred in 7.2% of the elderly, compared to 3.1% of the younger group (p < .001). All-cause mortality was significantly higher among the elderly group compared to the younger group (10.1% vs. 2.3%, p < .0001), as well as CD (6.1% vs. 1.6%, p < .0001), but not TV-MI (1.1% vs. 0.7%, p = .34) or CD-TLR (1.1% vs. 1.4%, p = .63). CONCLUSION: Elderly patients with STEMI presentation had a higher incidence of the composite endpoint than younger patients. All-cause and CD were higher for elderly patients compared to patients younger than 80 years old. However, there was no difference in the incidence of TV-MI or target lesion revascularizations. These findings suggest that PCI for STEMI in elderly patients is relatively safe.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Intervenção Coronária Percutânea/efeitos adversos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Sistema de Registros , Prognóstico
13.
J Interv Cardiol ; 2022: 6858962, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36128073

RESUMO

Objectives: To determine the incidence of upper extremity dysfunction (UED), after a transradial percutaneous coronary intervention (TR-PCI). Background: Transradial approach (TRA) is the preferred approach for coronary interventions. However, upper extremity complications may be underreported. Methods: The ARCUS was designed as a prospective cohort study, including 502 consecutive patients admitted for PCI. Patients treated with transfemoral PCI (TF-PCI) acted as a control group. A composite score of physical examinations and questionnaires was used for determining UED. Clinical outcomes were monitored during six months of follow-up, with its primary endpoint at two weeks. Results: A total of 440 TR-PCI and 62 control patients were included. Complete case analysis (n = 330) at 2 weeks of follow-up showed that UED in the TR-PCI group was significantly higher than that in the TF-PCI group: 32.7% versus 13.9%, respectively (p=0.04). The three impaired variables most contributing to UED were impaired elbow extension, wrist flexion, and extension. Multivariate logistic regression showed that smokers were almost three times more likely to develop UED. Conclusions: This study demonstrates that UED seems to occur two times more in TR-PCI than in TF-PCI at 2 weeks of follow-up. However, no significant long-term difference or difference between the intervention arm and the contralateral arm was found at all timepoints.


Assuntos
Intervenção Coronária Percutânea , Artéria Femoral , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Artéria Radial , Resultado do Tratamento , Extremidade Superior
14.
J Am Heart Assoc ; 11(17): e025459, 2022 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-36000428

RESUMO

Background Coronary bifurcation lesions (CBLs) are frequently encountered in clinical practice and are associated with worse outcomes after percutaneous coronary intervention. However, there are limited data around the prognostic impact of different CBL distributions. Methods and Results All CBL percutaneous coronary intervention procedures from the prospective e-Ultimaster (Prospective, Single-Arm, Multi Centre Observations Ultimaster Des Registry) multicenter international registry were analyzed according to CBL distribution as defined by the Medina classification. Cox proportional hazards models were used to compare the hazard ratio (HR) of the primary outcome, 1-year target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and clinically driven target lesion revascularization), and its individual components between Medina subtypes using Medina 1.0.0 as the reference category. A total of 4003 CBL procedures were included. The most prevalent Medina subtypes were 1.1.1 (35.5%) and 1.1.0 (26.8%), whereas the least prevalent was 0.0.1 (3.5%). Overall, there were no significant differences in patient and procedural characteristics among Medina subtypes. Only Medina 1.1.1 and 0.0.1 subtypes were associated with increased target lesion failure (HR, 2.6 [95% CI, 1.3-5.5] and HR, 4.0 [95% CI, 1.6-9.0], respectively) at 1 year, compared with Medina 1.0.0, prompted by clinically driven target lesion revascularization (HR, 3.1 [95% CI, 1.1-8.6] and HR, 4.6 [95% CI, 1.3-16.0], respectively) as well as cardiac death in Medina 0.0.1 (HR, 4.7 [95% CI, 1.0-21.6]). No differences in secondary outcomes were observed between Medina subtypes. Conclusions In a large multicenter registry analysis of coronary bifurcation percutaneous coronary intervention procedures, we demonstrate prognostic differences in 1-year outcomes between different CBL distributions, with Medina 1.1.1 and 0.0.1 subtypes associated with an increased risk of target lesion failure.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Morte , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
15.
Patient Relat Outcome Meas ; 13: 145-155, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35783347

RESUMO

Purpose: The use of the Disability of the Arm, Shoulder and Hand (DASH) questionnaire and its shortened version, the QuickDASH, have been used to assess upper extremity function following a transradial percutaneous coronary intervention (TR-PCI). However, the use of these scores has not yet been validated for TR-PCI induced complications in the upper extremity. The aim of this study was to establish the validity of the DASH and the QuickDASH, for the assessment of upper extremity dysfunction following a transradial percutaneous coronary intervention (TR-PCI). Patients and Methods: This study was a diagnostic retrospective analysis of the ARCUS study, of whom 440 underwent TR-PCI and 62 control patients were treated via the transfemoral approach. All participants completed the DASH and QuickDASH questionnaire prior to the procedure and at each follow-up visit up to six months of follow-up. Receiver operating characteristics (ROC) were constructed to determine the validity of the questionnaires, using physical examinations to determine the occurrence of upper extremity dysfunction, according to the ARCUS study. Results: At each follow-up moment, the area under the curve (AUC) showed a poor ability of the DASH and QuickDASH to discriminate between patients with and without upper extremity dysfunction (AUC: 0.565-0.586). There was no significant difference between the questionnaires (p > 0.05). Conclusion: The DASH and QuickDASH questionnaires are both equally incapable of discriminating between patients with and without upper extremity dysfunction following a TR-PCI. Study results suggest that the DASH and QuickDASH questionnaires are incapable of discerning changes in upper extremity function as a result of procedural complications following a TR-PCI vs cardiac induced activity cessation.

16.
J Invasive Cardiol ; 34(6): E462-E468, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35652709

RESUMO

BACKGROUND: Randomized controlled trials for in-stent restenosis (ISR) and de novo lesions in small-diameter vessels have shown promising results, but data on DCB use in real-world practice are still scarce. The aim of the PEARL (Paclitaxel-Eluting Angioplasty Balloon in the Real-World) registry was to evaluate the safety and efficacy of a paclitaxel DCB in real-world percutaneous coronary intervention (PCI) practice. METHODS: Between 2014 and 2019, a total of 513 patients treated with the Protégé paclitaxel DCB (Wellinq) were prospectively included at 4 hospitals in the Netherlands. The primary endpoint was 2-year major adverse cardiac event (MACE), defined as cardiac death, target-vessel myocardial infarction, or target-lesion revascularization (TLR). RESULTS: DCB was used for ISR in 382 patients and for de novo lesions in 131 patients. Acute coronary syndrome was the reason for presentation in 58.9% of patients. At lesion level, 34.1% of lesions were classified as type B2 and 36.1% as type C. Predilation was performed in 62.2% and noncompliant DCB was used in 40.7% of lesions. DCB-related procedural complications were infrequent (3.3%, mostly coronary dissection [2.3%]). Bailout stenting was required in 3.1%. MACE during 2-year follow-up occurred in 17.1% of patients treated for ISR and 9.7% of patients treated for de novo lesions. The incidence of TLR was 11.7% of ISR patients and 2.9% of de novo patients. History of coronary artery bypass grafting and lesion length were predictors of MACE in patients treated for ISR. CONCLUSION: The use of Protégé paclitaxel DCB for PCI of ISR and de novo lesions is safe and effective during 2-year follow-up.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/cirurgia , Humanos , Paclitaxel/farmacologia , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Resultado do Tratamento
17.
Circ Cardiovasc Interv ; 15(5): e011728, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35485232

RESUMO

BACKGROUND: Autopsy studies have established that thin-cap fibroatheromas (TCFAs) are the most frequent cause of fatal coronary events. In living patients, optical coherence tomography (OCT) has sufficient resolution to accurately differentiate TCFA from thick-cap fibroatheroma (ThCFA) and not lipid rich plaque (non-LRP). However, the impact of OCT-detected plaque phenotype of nonischemic lesions on future adverse events remains unknown. Therefore, we studied the natural history of OCT-detected TCFA, ThCFA, and non-LRP in patients enrolled in the prospective multicenter COMBINE FFR-OCT trial (Combined Optical Coherence Tomography Morphologic and Fractional Flow Reserve Hemodynamic Assessment of Non-Culprit Lesions to Better Predict Adverse Event Outcomes in Diabetes Mellitus Patients). METHODS: In the COMBINE FFR-OCT trial, patients with diabetes and ≥1 lesion with a fractional flow reserve >0.80 underwent OCT evaluation and were clinically followed for 18 months. A composite primary end point of cardiac death, target vessel-related myocardial infarction, target-lesion revascularization, and hospitalization for unstable angina was evaluated in relation to OCT-based plaque morphology. RESULTS: A total of 390 patients (age 67.5±9 years; 63% male) with ≥1 nonischemic lesions underwent OCT evaluation: 284 (73%) had ≥1 LRP and 106 (27%) non-LRP lesions. Among LRP patients, 98 (34.5%) had ≥1 TCFA. The primary end point occurred in 7% of LRP patients compared with 1.9% of non-LRP patients (7.0% versus 1.9%; hazard ratio [HR], 3.9 [95% CI, 0.9-16.5]; P=0.068; log rank-P=0.049). However, within LRP patients, TCFA patients had a much higher risk for primary end point compared with ThCFA (13.3% versus 3.8%; HR, 3.8 [95% CI, 1.5-9.5]; P<0.01), and to non-LRP patients (13.3% versus 1.9%; HR, 7.7 [95% CI, 1.7-33.9]; P<0.01), whereas ThCFA patients had risk similar to non-LRP patients (3.8% versus 1.9%; HR, 2.0 [95% CI, 0.42-9.7]; P=0.38). Multivariable analyses identified TCFA as the strongest independent predictor of primary end point (HR, 6.79 [95% CI, 1.50-30.72]; P=0.013). CONCLUSIONS: Among diabetes patients with fractional flow reserve-negative lesions, patients carrying TCFA lesions represent only one-third of LRP patients and are associated with a high risk of future events while patients carrying LRP-ThCFA and non-LRP lesions portend benign outcomes. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02989740.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Reserva Fracionada de Fluxo Miocárdico , Placa Aterosclerótica , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/terapia , Vasos Coronários , Diabetes Mellitus/diagnóstico , Feminino , Humanos , Lipídeos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/patologia , Valor Preditivo dos Testes , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
18.
Hand (N Y) ; : 15589447211073832, 2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35245991

RESUMO

BACKGROUND: The transradial artery access is the benchmark approach in transradial percutaneous coronary intervention (TR-PCI). The purpose of this study was to evaluate the different complications, treatments, and outcome of upper extremity dysfunction following a TR-PCI. METHODS: This was a prospective cohort substudy of patients with access-site complications. The study population consisted of 433 patients treated with TR-PCI. Referral to the hand center was mandated if the patient experienced new-onset or increase of preexistent symptoms in the upper extremity. Patients were followed up to the last control visit (5-7 months after the index procedure) at the hand center. Outcome results were categorized in "symptom-free," "improvement of symptoms," and "no improvement." RESULTS: Forty-one (9% of total) patients underwent assessment at the hand center. Most frequent referral indication was pain in the intervention arm. Women, preexisting sensibility disorder, and osteoarthritis in the intervention arm were associated with increased odds of referral. The most common complications diagnosed were carpal tunnel syndrome (n = 18) and osteoarthritis (n = 15). Thirty patients required further medical treatment. Immobilization therapy was most applied. Seventeen (4% of total) patients had persisting symptoms despite medical treatment. CONCLUSIONS: The occurrence of complications in the upper extremity after a TR-PCI is small. Despite medical treatment, symptoms persisted in 4% of all patients treated with TR-PCI. Possible explanations for the persisting symptoms are exacerbation of latent osteoarthritis and carpal tunnel syndrome by trauma-induced edema. Awareness of TR-PCI-induced complications among all specialists is essential to optimize patient care.

19.
Int J Cardiol ; 351: 25-31, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-34979152

RESUMO

BACKGROUND: Several studies have compared surface electrocardiographic changes following different self-expandable (SE) (Evolut (Medtronic, USA); Acurate (Boston Scientific, USA); Portico (Abbott, USA); and Allegra (NVT, Germany)) and balloon-expandable (BE) Sapien-3 (Edwards Lifesciences, USA) transcatheter heart valves. We aimed to compare these prosthesis with the novel Myval BE prosthesis (Meril Life, India). METHODS: Academic European registry of consecutive patients with severe aortic stenosis who received any of the 6 aforementioned valves. Baseline, post-procedural, and discharge 12­leads electrocardiograms (ECG) were centrally analyzed and compared. RESULTS: A total of 1131 patients were included: 135 Myval (11.9%), 290 Sapien-3 (25.6%), 298 Evolut (26.3%), 180 Acurate (15.9%), 125 Portico (11.1%), and 103 Allegra (9.1%). There were no baseline differences in intraventricular conduction disturbances rate. Compared to the novel BE Myval, there were similar procedural and in-hospital outcomes. Similar rates of early new permanent pacemaker implant (PPI) were observed amongst Myval (7.4%), Sapien-3 (13.4%), and Acurate (9.1%), but Evolut, Portico, and Allegra presented significantly higher rates (18.5%, p = 0.003; 29.5% p < 0.001 and 22%, p = 0.001, respectively). Central analysis of ECGs, unraveled significant prolongation of the PR segment with Evolut, Portico and Allegra whereas Evolut, Acurate, and Portico showed significant QRS widening compared to Myval. However, at discharge no differences in PR segment duration were observed while, Evolut, and Portico- but not Acurate, Allegra or Sapien-3 - still presented significant widening of QRS segment compared to Myval. CONCLUSIONS: After blinded central ECG analysis, the novel Myval balloon-expandable prosthesis was associated with a low rate of early conduction disturbances.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
20.
Catheter Cardiovasc Interv ; 99(3): 889-895, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34390296

RESUMO

OBJECTIVES: We aimed to describe hemodynamic performance and clinical outcomes at 30-day follow-up of the balloon-expandable (BE) Myval transcatheter heart valve (THV) in low-risk patients. BACKGROUND: The results of the next-generation BE Myval THV in low-risk aortic stenosis (AS) patients are still unknown. METHODS: Retrospective registry performed in nine European centers including patients with low predicted operative mortality risk according to Society of thoracic surgeons (STS) and European system for cardiac operative risk evaluation (EuroSCORE-II) scores. RESULTS: Between September 2019 and February 2021, a total of 100 patients (51% males, mean age 80 ± 6.5 years) were included. Mean STS score and EuroSCORE-II were 2.4 ± 0.8% and 2.2 ± 0.7%, respectively. Intermediate sizes were used in 39% (21.5 mm: 8%, 24.5 mm: 15%, 27.5 mm: 15%). There were no cases of valve embolization, coronary artery occlusion, annulus rupture, or procedural death. A definitive pacemaker implantation was needed in eight patients (8%). At 30-day follow-up aortic valve area (0.7 ± 0.2 vs. 2.1 ± 0.6 cm2 ) and mean aortic valve gradient (43.4 ± 11.1 vs. 9.0 ± 3.7 mmHg) improved significantly (p < 0.001). Moderate aortic regurgitation occurred in 4%. Endpoints of early safety and clinical efficacy were 3 and 1%, respectively. CONCLUSIONS: Hemodynamic performance and 30-day clinical outcomes of the BE Myval THV in low-risk AS patients were favorable. Longer-term follow-up is warranted.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA