1.
Clin Chem Lab Med ; 59(3): 591-597, 2021 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-33112775

RESUMO

OBJECTIVES: Biotin >20 ng/mL may interfere with the Elecsys® Troponin T-high sensitive assay (cTnT-hs; Roche Diagnostics International Ltd). We evaluated the performance of an updated assay, cTnT-hs*, which was designed to reduce biotin interference. METHODS: cTnT-hs* assay performance was assessed using up to two applications (18 min/9 min) on three analyzers (cobas e 411/cobas e 601/cobas e 801). Biotin interference was determined by measuring recovery in an 11-sample series dilution with biotin ranging from 0-3600 ng/mL. Repeatability/reproducibility were evaluated in five serum sample pools (n=75 each). Method comparisons tested: cTnT-hs* vs. cTnT-hs (18 min/cobas e 601); cTnT-hs* assay 18 vs. 9 min (cobas e 601); cTnT-hs* (18 min) on cobas e 601 vs. cobas e 411 and cobas e 601 vs. cobas e 801. Concordance at the 99th percentile decision limit between cTnT-hs* and cTnT-hs (9 min/cobas e 601) was calculated using 300 lithium-heparin plasma samples and a 14 ng/L assay cutoff. RESULTS: cTnT-hs* assay (18 min/cobas e 601) recovery was ≥96% for biotin ≤1250 ng/mL. Across all applications/analyzers, coefficients of variation for repeatability/reproducibility with the cTnT-hs* assay were <5% in most serum sample pools (mean cardiac troponin T: 8.528-9484 ng/L). High correlation (Pearson's r=1.000) was demonstrated for all method comparisons. Concordance at the 99th percentile decision limit was high between the cTnT-hs* and cTnT-hs assays. CONCLUSIONS: The updated cTnT-hs* assay may provide greater tolerance to biotin interference, and shows good analytical and clinical agreement/concordance with the previous cTnT-hs assay.


Assuntos
Troponina T/análise , Biomarcadores , Biotina , Heparina , Reprodutibilidade dos Testes , Troponina
2.
J Clin Microbiol ; 55(7): 2180-2187, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28468860

RESUMO

Screening of blood for human T-cell lymphotropic virus type 1 and type 2 (HTLV-1 and -2, respectively) is important to diagnose and prevent infection and ensure the safety of blood supplies. The Elecsys HTLV-I/II assay is a newly developed, electrochemiluminescence screening assay for the detection of HTLV-1/2 infection. The sensitivity and specificity of the Elecsys HTLV-I/II assay were determined using well-characterized HTLV-1/2-positive serum and plasma samples and routine diagnostic and blood donor samples expected to be HTLV negative, respectively. These results were compared with those for at least one of the following CE-marked assays at seven independent laboratories and the Roche Diagnostics facility in Penzberg, Germany: Abbott Architect rHTLV-I/II, Ortho Avioq HTLV-I/II Microelisa system, Abbott Prism HTLV-I/HTLV-II, and DiaSorin Murex HTLV I+II. Fujirebio INNO-LIA HTLV-I/II Score was used as a confirmatory assay. The Elecsys HTLV-I/II, Abbott Architect rHTLV-I/II, and Abbott Prism HTLV-I/HTLV-II assays detected all HTLV-1/2-positive samples (sensitivity, 100%). Sensitivity for Ortho Avioq HTLV-I/II was 98.63%. The Elecsys HTLV-I/II assay had a specificity of 99.95% in blood donor samples, which was comparable to results for the other assays (range, 99.91 to 100%). In routine diagnostic samples, the specificity of the Elecsys HTLV-I/II assay was 99.83%, compared with 99.70% for Abbott Architect rHTLV-I/II. Specificity for the Elecsys HTLV-I/II assay in potentially cross-reactive samples was 100%, compared with 99.0% for Ortho Avioq HTLV-I/II and 99.2% for DiaSorin Murex HTLV I+II. The Elecsys HTLV-I/II assay has the sensitivity and specificity to support its use as a routine screening assay for detecting HTLV infection.


Assuntos
Sangue/virologia , Infecções por HTLV-I/diagnóstico , Infecções por HTLV-II/diagnóstico , Vírus Linfotrópico T Tipo 1 Humano/isolamento & purificação , Vírus Linfotrópico T Tipo 2 Humano/isolamento & purificação , Programas de Rastreamento/métodos , Europa (Continente) , Humanos , Japão , Medições Luminescentes/métodos , Sensibilidade e Especificidade
3.
Clin Vaccine Immunol ; 22(1): 17-26, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25355799

RESUMO

Syphilis is a health problem of increasing incidence in recent years that may have severe complications if not diagnosed and treated at an early stage. There are many diagnostic tests available for syphilis, but there is no gold standard, and diagnosis therefore usually relies upon a combination of tests. In this multicenter study, we evaluated the treponemal Elecsys syphilis assay for use in the diagnosis of syphilis in routine samples, i.e., when syphilis is suspected or during antenatal or blood donation screening. The sensitivity and specificity of the Elecsys syphilis assay were compared head to head with those of other treponemal assays used in routine clinical practice and were assessed in potentially cross-reactive samples from patients with Epstein-Barr virus, HIV, and Lyme disease. In a total of 8,063 syphilis-negative samples collected from routine diagnostic requests and blood donations, the Elecsys syphilis assay had a specificity of 99.88%. In 928 samples previously identified as syphilis positive, the sensitivity was 99.57 to 100% (the result is presented as a range depending on whether four initially indeterminate samples are included in the assessment). The specificity of the Elecsys syphilis assay in patients with other infections was 100%; no false-positive samples were identified.


Assuntos
Anticorpos Antibacterianos/sangue , Testes Diagnósticos de Rotina/métodos , Sífilis/diagnóstico , Treponema pallidum/imunologia , Humanos , Imunoensaio/métodos , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Sífilis/imunologia
4.
J Med Virol ; 85(8): 1362-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23765774

RESUMO

Routine screening of patients at risk of hepatitis C virus (HCV) infection has become a priority given recent improvements in therapeutic options and the asymptomatic nature of most chronic infections. The aim of this study was to evaluate the performance of the Elecsys® Anti-HCV II assay, a new qualitative antibody immunoassay, compared with currently available assays, and assess its suitability for routine diagnostic testing. The sensitivity of the Elecsys® Anti-HCV II, ARCHITECT® Anti-HCV, AxSYM® HCV 3.0, PRISM® HCV, Vitros® ECi Anti-HCV, Elecsys® Anti-HCV, and ADVIA Centaur® HCV assays was compared using commercially available seroconversion panels and samples from patients known to be HCV positive and infected with HCV genotypes 1-6. Specificity was investigated using samples from blood donors, unselected hospitalized patients, and patients with potential cross-reacting factors or from high-risk groups. The Elecsys® Anti-HCV II assay detected more positive bleeds than the comparator assays, was more sensitive in recognizing early HCV infection, and correctly identified all 765 samples known to be HCV positive, regardless of genotype. The overall specificity of the Elecsys(®) Anti-HCV II assay was 99.84% (n=6,850) using blood donor samples, 99.66% (n=3,922) using samples from unselected hospitalized patients, and 99.66% (n=2,397) using samples from patients with potentially cross-reacting factors or from high-risk groups. The specificity of the Elecsys® Anti-HCV II assay was superior or equal to the comparator assays. In conclusion, the Elecsys® Anti-HCV II assay is a sensitive and specific assay suitable for routine use in the reliable detection of anti-HCV antibodies.


Assuntos
Técnicas de Laboratório Clínico/métodos , Hepacivirus/imunologia , Anticorpos Anti-Hepatite C/sangue , Hepatite C/diagnóstico , Feminino , Humanos , Imunoensaio/métodos , Masculino , Gravidez , Sensibilidade e Especificidade
5.
J Lab Autom ; 18(4): 306-27, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23321915

RESUMO

Clinical laboratories need to test patient samples precisely, accurately, and efficiently. The latest member of the Roche cobas modular platform family, the cobas 8000 modular analyzer series allows compact and convenient consolidation of clinical chemistry and immunochemistry assays in high-workload laboratories with a throughput of 3 to 15 million tests annually. Here we present the results of studies designed to test the overall system performance under routine-like conditions that were conducted at 14 laboratories over 2 y. Experiments that test analytical performance of the new module were integrated with overall system functionality testing of all modules in different configurations. More than two million results were generated and evaluated for ~100 applications using serum/plasma, urine, or EDTA blood samples. During the workflow studies, eight configurations of the possible 38 combinations were used, covering all available analytical modules. The versatility of the module combinations makes the system customizable to fit the needs of diverse laboratories, allowing precise and accurate analysis of a broad spectrum of clinical chemistry and immunochemistry parameters with short turnaround times. This new system will contribute to the ability of clinical laboratories to offer better service to their customers and support vital clinical decision making.


Assuntos
Técnicas de Química Analítica/instrumentação , Técnicas de Laboratório Clínico/instrumentação , Técnicas Analíticas Microfluídicas , Austrália , Automação Laboratorial , Técnicas de Química Analítica/normas , Testes Diagnósticos de Rotina , Europa (Continente) , Ensaios de Triagem em Larga Escala , Humanos , Reprodutibilidade dos Testes , Estados Unidos
6.
J Autom Methods Manag Chem ; 2008: 498921, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18401449

RESUMO

MODULAR ANALYTICS Serum Work Area (in USA Integrated MODULAR ANALYTICS, MODULAR ANALYTICS is a trademark of a member of the Roche Group) represents a further approach to automation in the laboratory medicine. This instrument combines previously introduced modular systems for the clinical chemistry and immunochemistry laboratory and allows customised combinations for various laboratory workloads. Functionality, practicability, and workflow behaviour of MODULAR ANALYTICS Serum Work Area were evaluated in an international multicenter study at six laboratories. Across all experiments, 236000 results from 32400 samples were generated using 93 methods. Simulated routine testing which included provocation incidents and anomalous situations demonstrated good performance and full functionality. Heterogeneous immunoassays, performed on the E-module with the electrochemiluminescence technology, showed reproducibility at the same level of the general chemistry tests, which was well within the clinical demands. Sample carryover cannot occur due to intelligent sample processing. Workflow experiments for the various module combinations, with menus of about 50 assays, yielded mean sample processing times of <38 minutes for combined clinical chemistry and immunochemistry requests; <50 minutes including automatically repeated samples. MODULAR ANALYTICS Serum Work Area offered simplified workflow by combining various laboratory segments. It increased efficiency while maintaining or even improving quality of laboratory processes.

7.
Clin Chem Lab Med ; 42(10): 1186-202, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15552279

RESUMO

The E170 module was evaluated at 13 sites in an international multicentre study. The objective of the study was to assess the analytical performance of 49 analytes, and to collect feedback on the system's reliability and practicability. The typical, within-run coefficients of variation (CVs) for most of the quantitative assays ranged between 1 and 2% while a range of 2-4% was achieved with the infectious disease methods. Total precision CVs were found to be within the manufacturer's expected performance ranges, demonstrating good concordance of the system's measuring channels and a high reproducibility during the 2-4-week trial period. The functional sensitivity of 11 selected assays met the clinical requirements (e.g., thyreotroponin (TSH) 0.008 mU/l, troponin T 0.02 microg/l, total prostate-specific antigen (PSA) 0.03 microg/l). The E170 showed no drift during an 8-hour period and no relevant reagent carryover. Accuracy was confirmed by ring trial experiments and method comparisons vs. Elecsys 2010. The reliability and practicability of the system's hardware and software met with, or even exceeded, the evaluator's requirements. Workflow studies showed that E170 can cover the combined workload of various routine analysers in a variety of laboratory environment. Throughput and sample processing time requirements were achieved while personnel 'hands-on-time' could be reduced.


Assuntos
Química Clínica/métodos , Reprodutibilidade dos Testes , Calibragem , Ferritinas/sangue , Humanos , Masculino , Antígeno Prostático Específico/sangue , Kit de Reagentes para Diagnóstico/classificação , Kit de Reagentes para Diagnóstico/normas , Sensibilidade e Especificidade , Software , Tireotropina/sangue , Tempo , Troponina/sangue