Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
Eur J Intern Med ; 106: 90-96, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36202717

RESUMO

BACKGROUND/AIM: Despite the prognostic role of frailty among elderly patients undergoing transcatheter aortic valve implantation (TAVI) is known, its assessment still represents a challenge due to the multitude of scales proposed in literature. The aim of this study was to define the prognostic impact of a simple combined frailty model including both functional and metabolic parameters in a large cohort of patients undergoing TAVI with new generation devices. METHODS AND RESULTS: We examined 1-year survival of patients affected by aortic valve stenosis treated with new generation TAVI devices from the OBSERVANT II study. Frailty of patients undergoing TAVI was stratified in four groups according to a combination of functional (geriatric status scale - GSS) and metabolic (global nutritional risk index - GNRI) assessment. Among 1985 patients included in the analysis, 1008 (51%) had no significant frailty, 246 (12%) had only functional impairment, 522 (26%) had only metabolic impairment and 209 (11%) had both functional and metabolic impairment. The presence of combined functional and metabolic frailty was associated with a two-fold increased risk of 1-year all-cause mortality (HR 2.06 [95% CI 1.35-3.14]; p = 0.001). GNRI as a single parameter had a lower impact on mortality (HR 1.48 [95% CI 1.05 - 2.09]; p = 0.027), whereas GSS did not impact on mortality (HR 1.23 [95% CI 0.77-1.97]; p = 0.386). CONCLUSIONS: In a large real-world cohort of patients undergoing TAVI with new generation devices, combined functional and metabolic frailty had a significant and incremental impact on 1-year mortality.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Estenose da Valva Aórtica/cirurgia , Fatores de Tempo , Resultado do Tratamento , Valva Aórtica/cirurgia
2.
Int J Cardiol ; 349: 31-38, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-34843819

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is safe and feasible in patients with bicuspid aortic valve (BAV), but whether annular size may influence TAVR results in BAV patients remains unclear. We aimed at evaluating the impact of aortic annular size on procedural and clinical outcomes of BAV patients undergoing TAVR, as well as potential interactions between annular dimension and trans-catheter heart valve (THV) type (balloon-expandable (BEV) vs. self-expanding (SEV). METHODS: BEAT is a multicenter registry of consecutive BAV stenosis undergoing TAVR. For this sub-study patients were classified according to annular dimension in small-annulus (area < 400 mm2 or perimeter <72 mm), medium-annulus (area ≥ 400 and < 575 mm2, perimeter ≥72 mm and< 85 mm), large-annulus (area ≥ 575 mm2 or perimeter ≥85 mm). Primary endpoint was Valve Academic Research Consortium-2 (VARC-2) device success. RESULTS: 45(15.5%) patients had small, 132(45.3%) medium, and 114(39.2%) large annuli. Compared with other groups, patients with large annuli were more frequently male, younger, with higher body mass index, larger aortic valve area, higher rate of moderate-severe calcification, lower mean trans-aortic valve gradient and lower left ventricular ejection fraction. In large-annuli SEVs were associated with a lower VARC-2 device success (75.9% vs. 90.6%, p = 0.049) driven by a higher rate of paravalvular valvular leak (PVL) compared to BEVs (20.7% vs. 1.2%, p < 0.001). However, no differences in clinical outcomes were observed according to annular size nor THV type. CONCLUSIONS: TAVR in BAV patients is feasible irrespective of annular size. However in patients with large aortic annulus SEVs were associated with a significantly higher rate of PVLs compared to BEVs.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Catéteres , Constrição Patológica , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
4.
Clin Res Cardiol ; 110(5): 667-675, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33389062

RESUMO

OBJECTIVES: To define the incidence of high residual gradient (HRG) after transcatheter aortic valve replacement (TAVR) in BAVs and their impact on short term outcome and 1-year mortality. BACKGROUND: Transcatheter heart valves (THVs) offer good performance in tricuspid aortic valves with low rate of HRG. However, data regarding their performance in bicuspid aortic valves (BAV) are still lacking. METHODS: The BEAT (Balloon vs Self-Expandable valve for the treatment of bicuspid Aortic valve sTenosis) registry included 353 consecutive patients who underwent TAVR (Evolut R/PRO or Sapien 3 valves) in BAV between June 2013 and October 2018. The primary endpoint was device unsuccess with post-procedural HRG (mean gradient ≥ 20 mmHg). The secondary endpoint was to identify the predictors of HRG following the procedure. RESULTS: Twenty patients (5.6%) showed HRG after TAVR. Patients with HRG presented higher body mass index (BMI) (30.7 ± 9.3 vs. 25.9 ± 4.8; p < 0.0001) and higher baseline aortic mean gradients (57.6 ± 13.4 mmHg vs. 47.7 ± 16.6, p = 0.013) and more often presented with BAV of Sievers type 0 than patients without HRG. At multivariate analysis, BMI [odds ratio (OR) 1.12; 95% confidence interval (CI) 1.05-1.20, p = 0.001] and BAV type 0 (OR 11.31, 95% CI 3.45-37.06, p < 0.0001) were confirmed as independent predictors of high gradient. CONCLUSION: HRG following TAVR in BAVs is not negligible and is higher among patients with high BMI and with BAV 0 anatomy.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/patologia , Doença da Válvula Aórtica Bicúspide/patologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Mortalidade , Sistema de Registros , Resultado do Tratamento
5.
Int J Cardiol ; 325: 109-114, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-33148461

RESUMO

BACKGROUND: Although bicuspid aortic valve (BAV) is not considered a "sweet spot" to trans-catheter aortic valve replacement (TAVR), a certain number of BAV underwent TAVR. Whether BAV phenotype affects outcomes following TAVR remains debated. We aimed at evaluating the impact of BAV phenotype on procedural and clinical outcomes after TAVR using new generation trans-catheter heart valves (THVs). METHODS: patients included in the BEAT registry were classified according to the BAV phenotype revealed at multi-slice computed tomography (MSCT) in type 0 (no raphe) vs. type 1 (1 raphe). Primary end-point was Valve Academic Research Consortium-2 (VARC-2) device success. Secondary end-points included procedural complications, rate of permanent pacemaker implantation, clinical outcomes at 30-day and 1-year. RESULTS: Type 0 BAV was present in 25(7.1%) cases, type 1 in 218(61.8%). Baseline characteristics were well balanced between groups. Moderate-severe aortic valve calcifications at MSCT were less frequently present in type 0 vs. type 1 (52%vs.71.1%,p = 0.05). No differences were reported for THV type, size, pre and post-dilation between groups. VARC-2 success tended to be lower in type 0 vs. type 1 BAV (72%vs86.7%;p = 0.07). Higher rate of mean transprosthetic gradient ≥20 mmHg was observed in type 0 vs. type 1 group (24%vs6%,p = 0.007). No differences were reported in the rate of post-TAVR moderate-severe aortic regurgitation and clinical outcomes between groups. CONCLUSIONS: Our study confirms TAVR feasibility in both BAV types, however a trend toward a lower VARC-2 device success and a higher rate of mean transprosthetic gradient ≥20 mmHg was observed in type 0 vs. type 1 BAV.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Catéteres , Constrição Patológica , Humanos , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Circ Cardiovasc Interv ; 13(7): e008714, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32646304

RESUMO

BACKGROUND: Large data comparing the performance of new-generation self-expandable versus balloon-expandable transcatheter heart valves in bicuspid aortic stenosis are lacking. We aim to compare the safety and performance of balloon-expandable and self-expandable transcatheter heart valves in the treatment of bicuspid aortic stenosis. METHODS: The BEAT (balloon versus self-expandable valve for the treatment of bicuspid aortic valve stenosis) registry included 353 consecutive patients who underwent transcatheter aortic valve implantation using new-generation Evolut R/PRO or Sapien 3 valves in bicuspid aortic valve. RESULTS: A total of 353 patients (n=242 [68.6%] treated with Sapien 3 and n=111 [68.6%] treated with Evolut R (n=70)/PRO [n=41]) were included. Mean age was 77.8±8.3 years and mean Society of Thoracic Surgeons Predicted Risk of Mortality was 4.4±3.3%. Valve Academic Research Consortium-2 device success was similar between Sapien 3 and Evolut R/PRO (85.6% versus 87.2%; P=0.68). In the Sapien 3 group, 4 patients experienced annular rupture whereas this complication did not occur in the Evolut R/PRO group. After propensity score matching, Valve Academic Research Consortium-2 device success was similar between both groups (Sapien 3=85.7% versus Evolut R/Pro=84.4%; P=0.821). Both in the overall and in the matched population, no differences in the rate of permanent pacemaker implant were observed. At 1-year follow-up, the rate of overall death and cardiovascular death were similar between the 2 groups. In the unmatched population, the 1-year echocardiographic follow-up demonstrated similar rate of moderate-to-severe paravalvular aortic regurgitation (Evolut R/PRO 10.5% versus Sapien 3 4.2%, P=0.077); however, after propensity matching, the rate of moderate-to-severe paravalvular leak became significantly higher among patients treated with self-expandable valves (9.3% versus 0%; P=0.043). CONCLUSIONS: Our study confirms the feasibility of both Sapien 3 and Evolut R/PRO implantation in bicuspid aortic valve anatomy; a higher rate of moderate-severe paravalvular aortic regurgitation was observed in the Evolut R/PRO group at 1-year follow-up in the matched cohort, although patients treated with balloon-expandable valve had a higher rate of annular rupture.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Doença da Válvula Aórtica Bicúspide/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Europa (Continente) , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Circ Cardiovasc Interv ; 11(11): e006927, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30571207

RESUMO

BACKGROUND: The impact of preexisting left bundle branch block (LBBB) in transcatheter aortic valve replacement (TAVR) recipients is unknown. The aim of this study was to determine the impact of preexisting LBBB on clinical outcomes after TAVR. METHODS AND RESULTS: This multicenter study evaluated 3404 TAVR candidates according to the presence or absence of LBBB on baseline ECG. TAVR complications and causes of death were defined according to Valve Academic Research Consortium-2 definitions. Follow-up outpatient visits or telephone interviews were conducted at 30 days, 12 months, and yearly thereafter. Echocardiography examinations were performed at baseline, at hospital discharge, and at 1-year follow-up. Preexisting LBBB was present in 398 patients (11.7%) and was associated with an increased risk of permanent pacemaker implantation (PPI; 21.1% versus 14.8%; adjusted odds ratio, 1.51; 95% CI, 1.12-2.04) but not death (7.3% versus 5.5%; adjusted odds ratio, 1.33; 95% CI, 0.84-2.12) at 30 days. At a mean follow-up of 22±21 months, there were no differences between patients with and without preexisting LBBB in overall mortality (adjusted hazard ratio, 0.94; 95% CI, 0.75-1.18) and cardiovascular mortality (adjusted hazard ratio, 0.90; 95% CI, 0.68-1.21). In a subanalysis of 2421 patients without PPI at 30 days and with complete follow-up about the PPI, preexisting LBBB was not associated with an increased risk of PPI or sudden cardiac death. Patients with preexisting LBBB had a lower left ventricular ejection fraction (LVEF) at baseline and at 1-year follow-up ( P <0.001 for both), but those with low LVEF exhibited a similar increase in LVEF over time after TAVR compared with patients with no preexisting LBBB ( P=0.327). CONCLUSIONS: Preexisting LBBB significantly increased the risk of early (but not late) PPI after TAVR, without any significant effect on overall mortality or cardiovascular mortality. Preexisting LBBB was associated with lower LVEF pre-TAVR but did not prevent an increase in LVEF post-TAVR similar to patients without LBBB.


Assuntos
Valva Aórtica/cirurgia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Doenças das Valvas Cardíacas/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Brasil/epidemiologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/mortalidade , Bloqueio de Ramo/fisiopatologia , Canadá/epidemiologia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/mortalidade , Ecocardiografia , Eletrocardiografia , Europa (Continente)/epidemiologia , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Marca-Passo Artificial , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
8.
Circ., cariovasc. interv. (Print) ; 11(11): 006927, Nov. 2018. tab, graf
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1223598

RESUMO

BACKGROUND: The impact of preexisting left bundle branch block (LBBB) in transcatheter aortic valve replacement (TAVR) recipients is unknown. The aim of this study was to determine the impact of preexisting LBBB on clinical outcomes after TAVR. METHODS AND RESULTS: This multicenter study evaluated 3404 TAVR candidates according to the presence or absence of LBBB on baseline ECG. TAVR complications and causes of death were defined according to Valve Academic Research Consortium-2 definitions. Follow-up outpatient visits or telephone interviews were conducted at 30 days, 12 months, and yearly thereafter. Echocardiography examinations were performed at baseline, at hospital discharge, and at 1-year follow-up. Preexisting LBBB was present in 398 patients (11.7%) and was associated with an increased risk of permanent pacemaker implantation (PPI; 21.1% versus 14.8%; adjusted odds ratio, 1.51; 95% CI, 1.12­2.04) but not death (7.3% versus 5.5%; adjusted odds ratio, 1.33; 95% CI, 0.84­2.12) at 30 days. At a mean follow-up of 22±21 months, there were no differences between patients with and without preexisting LBBB in overall mortality (adjusted hazard ratio, 0.94; 95% CI, 0.75­1.18) and cardiovascular mortality (adjusted hazard ratio, 0.90; 95% CI, 0.68­1.21). In a subanalysis of 2421 patients without PPI at 30 days and with complete follow-up about the PPI, preexisting LBBB was not associated with an increased risk of PPI or sudden cardiac death. Patients with preexisting LBBB had a lower left ventricular ejection fraction (LVEF) at baseline and at 1-year follow-up (P <0.001 for both), but those with low LVEF exhibited a similar increase in LVEF over time after TAVR compared with patients with no preexisting LBBB (P=0.327). CONCLUSIONS: Preexisting LBBB significantly increased the risk of early (but not late) PPI after TAVR, without any significant effect on overall mortality or cardiovascular mortality. Preexisting LBBB was associated with lower LVEF pre-TAVR but did not prevent an increase in LVEF post-TAVR similar to patients without LBBB.


Assuntos
Bloqueio de Ramo , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos
9.
J Am Heart Assoc ; 7(15): e008440, 2018 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-30371244

RESUMO

Background Long-term data on durability of currently available transcatheter heart valves are sparse. We sought to assess the incidence of long-term (8-year) structural valve dysfunction and bioprosthetic valve failure in a cohort of patients with transcatheter aortic valve replacement ( TAVR ) who reached at least 5-year follow-up. Methods and Results Consecutive patients with at least 5-year follow-up available undergoing TAVR from June 4, 2007 to March 30, 2012 were included. Structural valve dysfunction and bioprosthetic valve failure were defined according to newly standardized European Association of Percutaneous Cardiovascular Interventions/ European Society of Cardiology/European Association for Cardio-Thoracic Surgery criteria and reported as cumulative incidence function to account for the competing risk of death. A total of 288 consecutive patients with a mean age of 80.7±5.3 years and with a mean Society of Thoracic Surgery mortality score of 8.1±5.1% were analyzed. Survival rate at 8 years was 29.8%. Mean pressure gradients decreased from 53.3±15.9 mm Hg (pre- TAVR ) to 10.5±4.5 mm Hg (in-hospital post- TAVR ) ( P<0.001). There was a small, not significant, increase in the transaortic gradient throughout follow-up. Bioprosthetic valve failure was observed in a total of 11 patients (8-year cumulative incidence function: 4.51%; 95% confidence interval , 1.95%-8.76%). Severe and moderate structural valve dysfunctions were reported in 7 patients (8-year cumulative incidence function: 2.39%; 95% confidence interval, 0.77%-5.71%) and 13 patients (8-year cumulative incidence function: 5.87%; 95% confidence interval , 3.06%-9.96%), respectively. Aortic valve reintervention (redo TAVR ) was successfully performed in 2 patients (0.7%) presenting with symptomatic severe restenosis and intraprosthetic regurgitation subsequent to endocarditis. Conclusions In an aged population of patients with symptomatic severe aortic stenosis treated with first-generation bioprostheses, TAVR was associated with a survival rate of 30% but low rates of bioprosthetic valve failure and structural valve dysfunction at 8 years.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica , Feminino , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/epidemiologia , Recidiva , Reoperação , Índice de Gravidade de Doença
11.
Eur J Cardiothorac Surg ; 52(5): 874-880, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28977359

RESUMO

OBJECTIVES: The most commonly used accesses for transcatheter aortic valve implantation (TAVI) are the transfemoral (TF-TAVI) and the transapical (TA-TAVI) ones. There are concerns about TA-TAVI use in patients with reduced left ventricular ejection fraction (LVEF). The aim of this retrospective multicentre study was to compare the outcomes of TA-TAVI and TF-TAVI in patients with poor LVEF. METHODS: Patients with LVEF ≤35% were included in the analysis. Data were obtained from the Italian Transcatheter Balloon-Expandable Registry (ITER), which enrolled patients undergoing TAVI with the Sapien bioprosthesis in 33 national centres. Patients were divided into 2 groups according to the access: TA or TF. A multivariable logistic regression analysis was performed in order to evaluate whether the type of approach (TA and TF) has an impact on outcomes. RESULTS: Between 2007 and 2012, 1882 patients were enrolled in the Registry. LVEF ≤35% was found in 208 (11.1%) patients. TA-TAVI and TF-TAVI were performed in 69 (33.2%) and 139 (66.8%) patients, respectively. Overall 30-day mortality was 11.6% and 7.9% in TA and TF patients, respectively (P = 0.45). Overall Kaplan-Meier survival was significantly higher in the TF-TAVI group (log rank: P = 0.003). Age [odds ratio (OR) 1.066, P = 0.016], creatinine (OR: 2.301, P < 0.001), preoperative permanent pacemaker (OR: 4.662, P = 0.035) and TA approach (OR: 2.577, P = 0.006) were identified as independent predictors of overall mortality at follow-up. However, the TA approach resulted an independent variable of mortality only 3 years after TAVI. CONCLUSIONS: TAVI yields good results in patients with depressed LVEF. Age, preoperative creatinine and preoperative pacemaker are independently associated with mortality. The TA access is associated with mortality only after 3 years of follow-up, thus probably reflecting a worse general clinical status of these patients.


Assuntos
Valva Aórtica/cirurgia , Volume Sistólico/fisiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Disfunção Ventricular Esquerda/fisiopatologia , Ecocardiografia , Humanos , Itália/epidemiologia , Estimativa de Kaplan-Meier , Sistema de Registros , Estudos Retrospectivos
12.
Circ Cardiovasc Interv ; 10(8)2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28768757

RESUMO

BACKGROUND: We sought to describe an optimized approach to coronary artery disease (CAD) screening and management in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: When invasive coronary angiography showed CAD, the treatment strategy and completeness of revascularization was determined based on coronary anatomy. TAVR was performed in the same setting if percutaneous coronary intervention (PCI) was uncomplicated; otherwise TAVR was postponed. A total of 604 patients undergoing CAD screening at the time of TAVR procedure were prospectively included in this study. Severe CAD was found in 136 patients (22.5%). Among patients with severe CAD, 53 patients (8.8%) underwent uncomplicated PCI. After PCI, TAVR was postponed in 2 patients (0.3%). In 83 patients (13.8%), coronary angiography showed severe CAD that was left untreated. After TAVR, all-cause and cardiovascular 30-day mortality rates were 2.4% and 1.4%, respectively. Disabling stroke, myocardial infarction, and life-threatening bleeding occurred in 0.5%, 0.8%, and 4.0% of patients, respectively. Acute kidney injury II or III rate was 3.3%. At 2 years, all-cause mortality rate was 14.1%. Disabling stroke and myocardial infarction occurred in 2.5% and 1.8% of patients, respectively. Patients undergoing TAVR and PCI in the same session had similar rate of the composite of death, disabling stroke, and myocardial infarction when compared with patients without CAD, and patients with severe CAD left untreated (TAVR+PCI: 10.4%; severe CAD left untreated: 15.4%; no-CAD: 14.8%; P=0.765). CONCLUSIONS: In patients undergoing TAVR, screening of CAD with invasive coronary angiography and ad hoc PCI during TAVR is feasible and was not associated with increased periprocedural risks. PCI followed by TAVR in the same session had similar outcomes than TAVR in which PCI was not performed.


Assuntos
Angiografia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico , Programas de Rastreamento/estatística & dados numéricos , Intervenção Coronária Percutânea/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Masculino
13.
JACC Cardiovasc Interv ; 10(15): 1564-1574, 2017 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-28734885

RESUMO

OBJECTIVES: This study sought to assess the influence of baseline right bundle branch block (RBBB) on all-cause and cardiovascular mortality as well as sudden cardiac death (SCD) among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Few data exist regarding the late clinical impact of pre-existing RBBB in TAVR recipients. METHODS: A total of 3,527 patients (mean age 82 ± 8 years, 50.1% men) were evaluated according to the presence of RBBB on baseline electrocardiography. Intraventricular conduction abnormalities were classified according to the American Heart Association, American College of Cardiology Foundation, and Heart Rhythm Society recommendations for standardization and interpretation of the electrocardiogram. TAVR complications and causes of death were defined according to Valve Academic Research Consortium 2 definitions. RESULTS: RBBB was present on baseline electrocardiography in 362 patients (10.3%) and associated with higher 30-day rates of permanent pacemaker implantation (PPI) (40.1% vs. 13.5%; p < 0.001) and death (10.2% vs. 6.9%; p = 0.024). At a mean follow-up of 20 ± 18 months, pre-existing RBBB was independently associated with all-cause mortality (hazard ratio [HR]: 1.31; 95% confidence interval [CI]: 1.06 to 1.63; p = 0.014) and cardiovascular mortality (HR: 1.45; 95% CI: 1.11 to 1.89; p = 0.006) but not with SCD (HR: 0.71; 95% CI: 0.22 to 2.32; p = 0.57). Patients with pre-existing RBBB and without PPI at discharge from the index hospitalization had the highest 2-year risk for cardiovascular death (27.8%; 95% CI: 20.9% to 36.1%; log-rank p = 0.007). In a subanalysis of 1,245 patients without PPI at discharge from the index hospitalization and with complete follow-up regarding the need for PPI, pre-existing RBBB was independently associated with the composite of SCD and PPI (HR: 2.68; 95% CI: 1.16 to 6.17; p = 0.023). CONCLUSIONS: Pre-existing RBBB was found in 10% of TAVR recipients and was associated with poorer clinical outcomes. Patients with baseline RBBB without permanent pacemakers at hospital discharge may be at especially high risk for high-degree atrioventricular block and/or SCD during follow-up. Future studies should evaluate strategies aimed at the early detection of patients at risk for late development of high-degree atrioventricular block.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bloqueio de Ramo/mortalidade , Morte Súbita Cardíaca/epidemiologia , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Brasil/epidemiologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Canadá/epidemiologia , Causas de Morte , Ecocardiografia , Eletrocardiografia , Europa (Continente)/epidemiologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Modelos de Riscos Proporcionais , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
Am J Cardiol ; 119(9): 1438-1442, 2017 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28325569

RESUMO

Advanced chronic kidney disease (CKD) is associated with poor outcomes in patients who underwent surgical aortic valve replacement, whereas its prognostic role in transcatheter aortic valve implantation (TAVI) remains unclear. This study aimed to investigate outcomes in patients with advanced CKD who underwent TAVI. A total of 1,904 consecutive patients who underwent balloon-expandable TAVI in 33 centers between 2007 and 2012 were enrolled in the Italian Transcatheter Balloon-Expandable Valve Implantation Registry. Advanced CKD was defined according to the estimated glomerular filtration rate: 15 to 29 ml/min/1.73 m2 stage 4 (S4), <15 ml/min/1.73 m2 stage 5 (S5). Edwards Sapien or Sapien-XT prosthesis were used. The primary end point was all-cause mortality during follow-up. Secondary end points were major adverse cardiac events at 30 days and at follow-up, defined with Valve Academic Research Consortium 2 criteria. A total of 421 patients were staged S5 (n = 74) or S4 (n = 347). S5 patients were younger and had more frequently porcelain aorta and a lower incidence of previous stroke. Periprocedural and 30-day outcomes were similar in S5 and S4 patients. During 670 (±466) days of follow-up, S5 patients had higher mortality rates (69% vs 39%, p <0.01) and cardiac death (19% vs 9%, p = 0.02) compared with S4 patients. Male gender (hazard ratio [HR] 1.6, 95% confidence interval [CI] 1.2 to 2.2), left ventricular ejection fraction <30% (HR 2.3, 95% CI 1.3 to 4), atrial fibrillation (HR 1.4, 95% CI 1.0 to 1.9), and S5 CKD (HR 1.5, 95% CI 1.0 to 2.1) were independent predictors of death. In conclusion, TAVI in predialytic or dialytic patients (i.e., S5) is independently associated with poor outcomes with more than double risk of death compared with patients with S4 renal function. Conversely, in severe CKD (i.e., S4) a rigorous risk stratification is required to avoid the risk of futility risk.


Assuntos
Estenose da Valva Aórtica/cirurgia , Taxa de Filtração Glomerular , Falência Renal Crônica/terapia , Mortalidade , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Diálise Renal , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Fibrilação Atrial/epidemiologia , Feminino , Humanos , Falência Renal Crônica/complicações , Masculino , Modelos de Riscos Proporcionais , Insuficiência Renal Crônica/complicações , Índice de Gravidade de Doença , Fatores Sexuais , Volume Sistólico , Resultado do Tratamento
15.
Heart ; 103(12): 931-936, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28069638

RESUMO

BACKGROUND: Percutaneous edge-to-edge mitral valve repair (PMVR) recently emerged as an effective treatment modality for patients with severe mitral regurgitation (MR). Length of postprocedural hospital stay may represent a modifiable cost associated with percutaneous treatment. We looked at feasibility, predictors and safety of early discharge (ED), defined as hospital discharge within 72 hours, in patients undergoing PMVR. METHODS AND RESULTS: Consecutive patients treated with MitraClip from October 2008 to December 2015 were analysed. Primary outcomes of interest were cardiovascular and non-cardiovascular mortality, rehospitalisation for heart failure and major adverse events at 30 days and 90 days. A total of 269 patients were included. Of these, 115 patients were early discharged (ED group). Rates of ED increased from 25.9% for the biennium 2008-2009 to 59.1% in 2014-2015 (p<0.001 for trend). In a penalised logistic regression model, male gender (OR=2.13, 95% CI 1.17 to 3.95) and procedural year (OR=2.13, 95% CI 1.51 to 3.11) were associated with higher probability of ED. Conversely, atrial fibrillation (OR=0.48, 95% CI 0.27 to 0.85), any Mitral Valve Academic Research Consortium bleeding (OR=0.07, 95% CI 0.01 to 0.60), log-transformed N-terminal pro-brain natriuretic peptide levels (OR=0.79, 95% CI 0.63 to 0.99) and postimplant MR grade (OR=0.60, 95% CI 0.37 to 0.94) conferred a lower likelihood of ED. In propensity score-weighted analyses, overall survival, freedom from heart failure and major adverse events at 30 days and 90 days were not different in ED and non-ED groups (all weighted log-rank p value>0.05). CONCLUSIONS: In selected patients undergoing PMVR, ED may be feasible and safe.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Alta do Paciente/tendências , Idoso , Ecocardiografia , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico , Prognóstico , Sistema de Registros , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo
17.
JACC cardiovasc. interv ; 10(15): 1564-1574, 2017. tab, graf
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1064046

RESUMO

This study sought to assess the influence of baseline right bundle branch block (RBBB) on all-cause and cardiovascular mortality as well as sudden cardiac death (SCD) among patients undergoing transcatheter aortic valve replacement (TAVR). Few data exist regarding the late clinical impact of pre-existing RBBB in TAVR recipients. A total of 3,527 patients (mean age 82 8 years, 50.1% men) were evaluated according to the presence of RBBB on baseline electrocardiography. Intraventricular conduction abnormalities were classified according to the American Heart Association, American College of Cardiology Foundation, and Heart Rhythm Society recommendations for standardization and interpretation of the electrocardiogram. TAVR complications and causes of death were defined according to Valve Academic Research Consortium 2 definitions. RBBB was present on baseline electrocardiography in 362 patients (10.3%) and associated with higher 30-day rates of permanent pacemaker implantation (PPI) (40.1% vs. 13.5%; p < 0.001) and death (10.2% vs. 6.9%; p » 0.024). At a mean follow-up of 20 18 months, pre-existing RBBB was independently associated with all-cause mortality (hazard ratio [HR]: 1.31; 95% confidence interval [CI]: 1.06 to 1.63; p » 0.014) and cardiovascular mortality (HR: 1.45; 95% CI: 1.11 to 1.89; p » 0.006) but not with SCD (HR: 0.71; 95% CI: 0.22 to 2.32; p » 0.57). Patients with pre-existing RBBB and without PPI at discharge from the index hospitalization had the highest 2-year risk for cardiovascular death (27.8%; 95% CI: 20.9% to 36.1%; log-rank p » 0.007). In a subanalysis of 1,245 patients without PPI at discharge from the index hospitalization and with complete follow-up regarding the need for PPI, pre-existing RBBB was independently associated with the composite of SCD and PPI (HR: 2.68; 95% CI: 1.16 to 6.17; p » 0.023)


Assuntos
Bloqueio de Ramo , Implante de Prótese de Valva Cardíaca , Morte Súbita Cardíaca
18.
Ann Thorac Surg ; 102(6): e517-e519, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27847070

RESUMO

New-onset systolic anterior motion of the anterior mitral valve leaflet in patients undergoing transcatheter aortic valve replacement is a rare pathophysiologic mechanism leading to postprocedural development of mitral regurgitation and, eventually, left ventricular outflow obstruction. We report the first human case of successful MitraClip implantation to treat new-onset systolic anterior motion of the mitral valve after transcatheter aortic valve replacement causing severe obstruction to left ventricular outflow that was unresponsive to standard medical therapy.


Assuntos
Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Idoso , Feminino , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem
19.
Int J Cardiol ; 224: 440-446, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27710781

RESUMO

BACKGROUND: Although mitral regurgitation (MR) affects a relevant and increasing number of elderly, an optimal management of this high-risk population is challenging. METHODS AND RESULTS: The aim of this prospective, observational study was to compare one-year outcomes of MitraClip therapy in high surgical risk patients with moderate-to-severe or severe MR between patients aged <75 versus ≥75years. A total of 180 patients were included: 92 were <75years and 88 were ≥75years old. At one-year follow-up the primary efficacy endpoint (composite of death, surgery for mitral valve dysfunction and grade 3+ or 4+ MR) occurred in 41 patients (24.5%), with similar rates between those aged <75years (23.9%) and those ≥75years (25.2%), p=0.912. A total of 21 (12.2%) deaths were observed within 1year after the MitraClip procedure, without significant differences in cumulative mortality rates between elderly and younger patients (10.8% vs. 13.3%, respectively, p=0.574). Compared with baseline, the significant reduction in MR severity achieved after the procedure was sustained at one-year follow-up, in both elderly and younger patients and a significant improvement in NYHA functional class was observed in both groups. A total of 18 (10.0%) patients experienced a re-hospitalization for acute heart failure within one-year after the MitraClip procedure, with no significant differences between elderly and younger. At one-year follow-up both elderly and younger patients showed significant reductions in left ventricular volumes, with changes of similar extent between the two subgroups. CONCLUSIONS: MitraClip therapy can be considered a viable option also among subsets with more advanced age.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Complicações Pós-Operatórias , Risco Ajustado/métodos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Ecocardiografia/métodos , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Índice de Gravidade de Doença
20.
Artigo em Inglês | MEDLINE | ID: mdl-27578840

RESUMO

BACKGROUND: Transcatheter aortic valves can degenerate in a manner similar to surgical bioprostheses. METHODS AND RESULTS: Clinical and echocardiographic outcomes of patients who underwent redo transcatheter aortic valve replacement (TAVR) procedures >2 weeks post procedure were collected from 14 centers. Among 13 876 patients, 50 (0.4%) underwent redo TAVR procedure at participating centers. Indications for redo TAVR were moderate-severe prosthetic aortic valve stenosis (n=10, 21.7%), moderate-severe central prosthetic aortic valve regurgitation (n=13, 28.3%), and moderate-severe paraprosthetic aortic valve regurgitation (n=25, 50.0%). The index TAVR was most commonly a Medtronic CoreValve (N=38, 76.0%), followed by Edwards SAPIEN-type valves (n=12, 24.0%) and Portico (n=1, 2.0%). The redo TAVR device was most commonly a CoreValve/Evolut R (n=29, 58.0%), followed by a SAPIEN-type valve (n=20,40.0%) or a Boston Lotus valve (n=1, 2.0%). In 40 patients (80.0%), redo TAVR was performed using the identical device type or that of the succeeding generation. Valve performance was uniformly good after redo TAVR (mean transvalvular gradient post redo TAVR: 12.5±6.1 mm Hg). At hospital discharge, all patients remained alive, with 1 nondisabling stroke (2.0%) and 1 life-threatening bleed (2.0%). Permanent pacemaker implantation was required in 3 out of 35 patients without a prior pacemaker (8.6%). Late survival was 85.1% at a median follow-up of 1589 days (range: 31-3775) after index TAVR and 635 days (range: 8-2460) after redo TAVR. CONCLUSIONS: Redo TAVR for the treatment of postprocedural and late occurrence of paravalvular regurgitation and transcatheter aortic valve prosthesis failure seems to be safe, and it is associated with favorable acute and midterm clinical and echocardiographic outcomes.


Assuntos
Insuficiência da Valva Aórtica/terapia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Canadá , Ecocardiografia , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA