Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Knee Surg ; 35(9): 978-982, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33241546

RESUMO

To determine accuracy of patient-specific instrumentation (PSI), the preoperative three-dimensional (3D) plan should be superimposed on the postoperative 3D image to compare prosthetic alignment. We aimed to compare prosthetic alignment on a preoperative 3D computed tomography (CT) plan and postoperative 3D-CT image, and evaluate the accuracy of PSI during total knee arthroplasty (TKA). Thirty consecutive knees (30 patients) who underwent TKA using PSI were retrospectively evaluated. The preoperative plan was prepared using 3D CT acquisitions of the hip, knee, and ankle joints. The postoperative 3D CT image obtained 1 week after surgery was superimposed onto the preoperative 3D plan using computer software. Differences in prosthetic alignment between the preoperative and postoperative images were measured using six parameters: coronal, sagittal, and axial alignments of femoral and tibial prostheses. Differences in prosthetic alignment greater than 3 degrees were considered outliers. Two observers performed all measurements. All parameters were repeatedly measured over a 4-week interval. This measurement method's intraobserver and interobserver reliabilities were more than 0.81 (very good). For the femoral and tibial prostheses, absolute differences between the preoperative and postoperative 3D CT images were significantly larger in the sagittal than in the coronal and axial planes (p < 0.001). The outlier rate for the sagittal alignment of femoral and tibial prostheses was significantly higher than that for the alignment of coronal and axial planes (p < 0.001). However, there were no significant differences in the range of motion (ROM) before and after TKA when comparing cases with and without outliers in the sagittal plane. Even though the present study did not reveal any issues with the ROM that depended on the presence of an outlier, accurate verification of prosthetic alignment for individual PSI models may be necessary because the designs, referenced images, and accuracy are different in each model.


Assuntos
Prótese do Joelho , Osteoartrite do Joelho , Cirurgia Assistida por Computador , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Imageamento Tridimensional/métodos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
2.
Arch Orthop Trauma Surg ; 141(9): 1583-1590, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33547928

RESUMO

BACKGROUND: In total knee arthroplasty (TKA) using patient-specific instrumentation (PSI), the correlation between the preoperative surgical plan and intraoperative resection size is unclear. The aims of this study were to evaluate whether the computed tomography (CT)-based PSI surgical plan can be executed accurately and to determine the accuracy of bone resection in TKA using PSI. METHODS: Data of 45 consecutive knees undergoing TKA using CT-based PSI were retrospectively evaluated. The preoperative plan was prepared using three-dimensional CT acquisitions of the hip, knee, and ankle joints. Resected bone thicknesses of the femoral condyle of the distal medial, distal lateral, posterior medial, posterior lateral, and medial and lateral tibial plateaus were measured with a Vernier caliper intraoperatively. Then these respective measurements were compared with those in the preoperative CT-predicted bone resection surgical plan, and the measured thickness of resection was subtracted from the planned resection thickness. Errors were defined as: acceptable, ≤ 1.5 mm; borderline, 1.5-2.5 mm; and outliers, > 2.5 mm. RESULTS: Overall, 22 (48.9%) knees had no outliers. There were 20 (44.4%) and 3 (6.7%) knees in which only 1 and 2 resection planes were outliers, respectively. The posterior medial tibial plateau had the lowest proportion of acceptable cuts (44.4%). Posterior femoral resection including the medial and lateral condyles had more outliers (n = 18/90 cuts, 20.0%) (p < 0.001) than the tibial condyles (n = 3/90 cuts, 3.3%) and distal femoral cuts (n = 6/90 cuts, 6.7%). The posterior surface of the femur, where the incidence of outliers was higher, tended to have a higher proportion of undercuts than other surfaces of the femur (> 80%). CONCLUSIONS: PSI showed only fair-to-moderate accuracy. The cutting guide for the posterior femur was less accurate than that for the tibia and distal femur. Specific attention is required when cutting the posterior femur. The PSI design needs to be improved to reduce errors.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Cirurgia Assistida por Computador , Osso e Ossos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
3.
J Arthroplasty ; 35(11): 3156-3160, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32631727

RESUMO

BACKGROUND: Our previous study showed that the decrease in relative change of bone mineral density (BMD) in the lateral part of the tibia was significantly less in the group treated with the cementless porous tantalum component than in the group treated with the cemented cobalt-chromium tibial component up to 5 years after the operation. However, the long-term benefits of porous tantalum tibial component on BMD have not been proven. The aim of this study was to update a matched cohort study at a minimum of 6 years' follow-up period. METHODS: Twenty patients with a porous tantalum tibial component and 18 patients with a cemented cobalt-chromium-alloy tibial component were investigated for more than 6 years in the present study. The mean follow-up period was 11.4 years. Dual X-ray absorptiometry was used to measure the BMD. RESULTS: The decrease in relative change of BMD in the lateral aspect of the tibia was significantly less with the porous tantalum tibial component than that with the cemented cobalt-chromium tibial component up to 5 years. However, at the final follow-up period, no significant difference was observed in the relative change of BMD between the 2 groups. No prosthetic migration or periprosthetic fracture was detected in either group. CONCLUSION: The present study is one of the studies with the longest follow-up period on BMD after total knee arthroplasty. Porous tantalum tibial component did not have a favorable effect on the BMD of the proximal tibia after total knee arthroplasty for long term.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/efeitos adversos , Densidade Óssea , Estudos de Coortes , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Porosidade , Desenho de Prótese , Tantálio , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
4.
J Orthop Surg (Hong Kong) ; 27(1): 2309499019825574, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30798729

RESUMO

BACKGROUND: Joint gap unbalancing during total knee arthroplasty (TKA) induces flexion contracture. Flexion contracture is one of the most serious complications of TKA. When flexion contracture is found during surgery, intraoperative manipulation is often empirically performed. We evaluated the effects of intraoperative manipulation on joint gap and postoperative flexion contracture. MATERIALS AND METHODS: TKA was performed for 136 knees. Intraoperative manipulation was performed for flexion contracture in 61 knees. Joint gap changes before and after manipulation were measured at six positions from extension to 120° of flexion. Manipulation was not performed for 75 knees. The extension angle was measured radiographically immediately after surgery, at 3 months, and 6 months postoperatively. Extension angles with manipulation and without manipulation were compared. RESULTS: Joint gap changes (mm) before and after manipulation were 0.1, 0.0, -0.2, -0.3, -0.1, and -0.3 at 0°, 30°, 45°, 60°, 90°, and 120° of flexion, respectively, indicating that manipulation could not change joint gaps significantly. Extension angles (°) with and without manipulation were -4.0 ± 4.6 and -3.8 ± 3.9 immediately after surgery, -5.3 ± 6.7 and -5.5 ± 6.2 at 3 months postoperatively, and -2.7 ± 6.0 and -3.8 ± 5.8 at 6 months postoperatively. No statistically significant difference existed between the values with or without manipulation during all periods. CONCLUSION: Intraoperative manipulation does not enlarge the gap or resolve postoperative flexion contracture. Developing the new surgical technique is required to achieve perfect balance at TKA.


Assuntos
Artroplastia do Joelho , Contratura/cirurgia , Osteoartrite do Joelho/cirurgia , Idoso , Idoso de 80 Anos ou mais , Contratura/etiologia , Feminino , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/fisiopatologia , Amplitude de Movimento Articular , Resultado do Tratamento
5.
Case Rep Orthop ; 2018: 9321830, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30009068

RESUMO

Calcaneal osteomyelitis (CO) is considered to be difficult to cure when it turned into a chronic phase. We report one case of calcaneal osteomyelitis which arises after the operation of calcaneal fracture. Remission was obtained by performing curettage of the infected cancellous bone of the calcaneal body and filling antibiotic-containing calcium phosphate cements (CPC) within its bone defect. This one-stage surgery is useful to treat calcaneal osteomyelitis.

6.
Case Rep Orthop ; 2015: 469879, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26064742

RESUMO

Rapidly destructive coxarthrosis (RDC) causes rapid and extreme destruction of the hip joint, which was reported by Postel and Kerboull. RDC is commonly unilateral and occurs mostly in elderly women. Immune thrombocytopenic purpura (ITP) is characterized by a low platelet count that is the result of both immune-mediated platelet destruction and suppression of platelet production. In patients with ITP undergoing surgery, bleeding associated with a low preoperative platelet count can lead to unsuccessful outcomes. To the best of our knowledge, there has been only one report describing total hip arthroplasty (THA) for patients with ITP and there have been no reports of THA for RDC with a very low platelet count due to liver cirrhosis (LC) and ITP. We report the case of a patient who had right RDC and a very low platelet count due to LC and ITP in whom THA was successfully performed. Furthermore, this case was also unique in that her platelet count increased after THA. THA for right RDC might resolve ITP by relieving inflammation of the right hip since her platelet count recovered after THA.

7.
Case Rep Orthop ; 2015: 549109, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26064743

RESUMO

Treatment of chronic symptoms caused by a malunion is a difficult problem in orthopedic surgery. We encountered a case of ankle malunion at our hospital about 1 year after the first operation. The patient had been unable to walk with weight-bearing but regained the ability to walk after reconstructive osteotomy of the fibula. Functional scores for the foot and ankle were significantly improved after intervention. Reconstructive osteotomy appears to represent a good option for ankle malunion.

8.
Case Rep Orthop ; 2014: 727949, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25197597

RESUMO

We present a case of osteonecrosis of femoral head (ONFH) that occurred after stent angiography of femoral artery for the treatment of arteriosclerosis obliterans (ASO) of left inferior limb in a 76-year-old woman. No case of late collapse of femoral head as a complication of endovascular procedure such as stent placement has been previously documented. We considered that ONFH occurred after detaining stent at a junction of left deep femoral artery for the treatment of the ischemia of left lateral and medial femoral circumflex artery.

9.
Knee Surg Sports Traumatol Arthrosc ; 22(3): 680-6, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24141905

RESUMO

PURPOSE: Polyethylene wear particle generation is one of the most important factors affecting mid- to long-term results of total knee arthroplasties. Oxidized zirconium was introduced as a material for femoral components to reduce polyethylene wear generation. However, an in vivo advantage of oxidized zirconium on polyethylene wear particle generation is still controversial. The purpose of this study was to compare in vivo polyethylene wear particles between oxidized zirconium total knee prosthesis and conventional cobalt-chromium (Co-Cr) total knee prosthesis. METHODS: Synovial fluid was obtained from the knees of 6 patients with oxidized zirconium total knee prosthesis and from 6 patients with conventional cobalt-chromium (Co-Cr) total knee prosthesis 12 months after the operation. Polyethylene particles were isolated and examined using a scanning electron microscope and image analyser. RESULTS: Total number of particles in each knee was 3.3 ± 1.3 × 10(7) in the case of oxidized zirconium (mean ± SD) and 3.4 ± 1.2 × 10(7) in that of Co-Cr (n.s.). The particle size (equivalent circle diameter) was 0.8 ± 0.3 µm in the case of oxidized zirconium and 0.6 ± 0.1 µm in that of Co-Cr (n.s.). The particle shape (aspect ratio) was 1.4 ± 0.0 in the case of oxidized zirconium and 1.4 ± 0.0 in that of metal Co-Cr (n.s). CONCLUSIONS: Although newly introduced oxidized zirconium femoral component did not reduce the in vivo polyethylene wear particles in early clinical stage, there was no adverse effect of newly introduced material. At this moment, there is no need to abandon oxidized zirconium femoral component. However, further follow-up of polyethylene wear particle generation should be performed to confirm the advantage of the oxidized zirconium femoral component. LEVEL OF EVIDENCE: Therapeutic study, Level III.


Assuntos
Artroplastia do Joelho/instrumentação , Ligas de Cromo , Prótese do Joelho , Próteses Articulares Metal-Metal , Polietileno , Falha de Prótese , Zircônio , Idoso , Feminino , Humanos , Articulação do Joelho/química , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Material Particulado/análise , Líquido Sinovial/química
10.
J Arthroplasty ; 28(10): 1760-4, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23642446

RESUMO

In 21 knees receiving porous tantalum tibial component and 21 knees receiving a cemented cobalt-chromium tibial component, dual x-ray absorptiometry scans were performed for five years post-operatively. The postoperative decrease in the bone mineral density in the lateral aspect of the tibia was significantly less in knees with porous tantalum tibial components (11.6%) than in knees with cemented cobalt-chromium tibial components (29.6%) at five years (p < 0.05). No prosthetic migration or periprosthetic fracture was detected in either group. The present study is one of the studies with the longest follow-up period on bone mineral density after total knee arthroplasty. Porous tantalum tibial component has a favorable effect on the bone mineral density of the proximal tibia after total knee arthroplasty up to five years.


Assuntos
Artroplastia do Joelho/efeitos adversos , Materiais Biocompatíveis , Reabsorção Óssea/diagnóstico por imagem , Prótese do Joelho/efeitos adversos , Osteoartrite do Joelho/cirurgia , Tantálio , Tíbia/diagnóstico por imagem , Absorciometria de Fóton , Idoso , Densidade Óssea , Reabsorção Óssea/etiologia , Ligas de Cromo , Estudos de Coortes , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Masculino , Estresse Mecânico , Tíbia/fisiopatologia
11.
Case Rep Orthop ; 2012: 973489, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23227399

RESUMO

We report the case of a 72-year-old woman whose pseudoaneurysm was difficult to diagnose and treat. The patient had a history of congenital dislocated hip and was undergoing anticoagulation therapy with warfarin due to the mitral valve replacement. Her chief complaint was pain and enlargement of the left buttock, and the laboratory tests revealed severe anemia. However, her elderly depression confused her chief complaint, and she was transferred to a psychiatric hospital. Two months after the onset of the symptoms, she was finally diagnosed with a pseudoaneurysm by contrast-enhanced CT and angiography. IDC coils were used for embolization. A plain CT showed hemostasis as well as a reduced hematoma at 2 months after the embolization. The possible contributing factors for the pseudoaneurysm included bleeding due to warfarin combined with an intramuscular hematoma accompanied by Crowe type IV developmental dysplasia of the hip that led to an arterial rupture by impingement between pelvis and femoral head. Since the warfarin treatment could not be halted due to the valve replacement, embolization was chosen for her treatment, and the treatment outcome was favorable.

12.
Orthopedics ; 35(10 Suppl): 7-12, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23026245

RESUMO

In total hip arthroplasty (THA) for dysplastic hip osteoarthritis, bony deformity makes it difficult to identify the correct cup height and medialization. The authors developed a new technique for registration and navigation of cup position for dysplastic hips using an imageless navigation system. Eighty dysplastic hips (Crowe type I, n=58; type II, n=18; type III, n=4) underwent THA. Thirty-four hips were operated on while in the supine position and 46 hips were operated on while in the lateral position. Before capsulectomy, the anterior pelvic plane and the position of the femur were registered. After exposure of the acetabulum, the teardrop, posterior rim, and medial wall of the acetabulum were registered. Then the cup height, cup medialization, cup inclination, anteversion, and leg lengthening were navigated. The difference between the navigated and radiographic cup heights was 4.5 ± 4.0 mm, the difference in cup medialization was 3.0 ± 2.5 mm, the difference in cup inclination was 4.3° ± 3.1°, the difference in cup anteversion was 5.5° ± 3.8°, and the difference in leg lengthening was 3.7 ± 3.0 mm. Comparison of the first 20 cases with the last 20 cases showed that the accuracy of cup medialization was significantly improved. These differences were not affected by Crowe type or surgical position. Because the correct cup height and medialization are key issues in THA for dysplastic hip osteoarthritis, the accuracy of cup height and medialization in this imageless navigation system were acceptable for clinical application.


Assuntos
Artroplastia de Quadril/métodos , Luxação Congênita de Quadril/cirurgia , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Artroplastia de Quadril/educação , Feminino , Luxação Congênita de Quadril/complicações , Luxação Congênita de Quadril/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/complicações , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/patologia , Posicionamento do Paciente , Radiografia , Reprodutibilidade dos Testes , Decúbito Dorsal , Cirurgia Assistida por Computador/educação , Fatores de Tempo , Resultado do Tratamento
13.
Transplantation ; 93(8): 761-8, 2012 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-22487811

RESUMO

BACKGROUND: We previously reported that transduction of the human interleukin (IL)-10 gene into the total fetal liver stem cells (hIL-10-TFLs) of mice protects against their rejection in an allogeneic host. In this study, we explored the effects of these cells in two different models of organ transplantation. METHODS: Balb/c mice were sublethally irradiated before receiving skin or vascularized heterotopic heart grafts from C57Bl/6 mice. TFLs from C57Bl/6 mice transduced with hIL-10 or untransduced TFLs were injected on the day of transplantation into recipient mice once or also every 20 days thereafter. RESULTS: Skin allograft survival was prolonged for up to 17.8±0.6 days, vs. 9.0±0.4 days, in mice that received hIL-10-TFLs or untransduced TFLs, respectively. Allogeneic heart transplants survived for 86.25±13.8, 46.3±4.6, 28.1±6.1, or 11.5±0.6 days in mice that received repeated injections of hIL-10-TFLs, a single injection of hIL-10-TFLs, repeated injections of untransduced TFLs, or controls, respectively. Histological analyses of the grafts showed fewer inflammatory foci and CD8+ infiltrating cells in mice injected with hIL-10-TFLs compared with untreated mice. Expressions of H-2b and hIL-10 were found in several organs, including the thymus, liver, and the transplant, in hIL-10-TFL-injected mice. Finally, in hIL-10-TFL-injected mice, FoxP3 T cells were present inside the transplanted heart as late as 140 days after transplantation. CONCLUSIONS: In this study, we showed that repeated injections of hIL-10-TFLs are efficient in mitigating transplant rejection. This "prope" tolerance was associated with survival of donor hematopoietic cells in the host.


Assuntos
Transplante de Coração/imunologia , Transplante de Células-Tronco Hematopoéticas , Células-Tronco Hematopoéticas/imunologia , Interleucina-10/imunologia , Tolerância ao Transplante/imunologia , Animais , Linfócitos T CD8-Positivos/imunologia , Fatores de Transcrição Forkhead/imunologia , Rejeição de Enxerto/imunologia , Transplante de Coração/patologia , Humanos , Inflamação/imunologia , Interleucina-10/genética , Interleucina-10/metabolismo , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Transplante de Pele/imunologia , Transdução Genética
14.
Clin Orthop Relat Res ; 468(12): 3201-6, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20405347

RESUMO

BACKGROUND: The direct anterior approach in THA is an intermuscular approach that requires no muscle detachment. However, it is difficult to elevate the proximal femur for access to the femoral canal. QUESTIONS/PURPOSES: We asked (1) which part of the capsule should be released to allow effective elevation of the proximal femur; (2) whether the release of the internal obturator tendon allows elevation; and (3) whether hip hyperextension reduces the ability to elevate the femur. METHODS: We conducted a cadaver study and a clinical study. In the first study, the elevation of the proximal femur was measured in 6 hips in 3 cadavers after excision of the anterior capsule, after the release of the superior capsule or the posterior capsule, after the release of the superior and posterior capsule, and after the release of the internal obturator tendon under traction of 70 N. Each hip was positioned at 0°, 15°, and 25° hyperextension. In the second study of 39 patients, the posterior capsule was released after the superior capsule in the first 13 hips, and the superior capsule was released after the posterior capsule in the next 26 hips. The elevation achieved for each hip was measured as in the cadaver study. RESULTS: In our cadaver study, hip elevation increased after superior capsule release but not after release of the internal obturator tendon. After superior capsule release, the ability to elevate the femur was not diminished by hip hyperextension. In our clinical study, elevation increased after superior capsule release. CONCLUSIONS: Superior capsule release was most effective of all releases for elevating the proximal femur in the direct anterior approach.


Assuntos
Artroplastia de Quadril/métodos , Fêmur/cirurgia , Articulação do Quadril/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Articulação do Quadril/fisiopatologia , Humanos , Japão , Cápsula Articular/cirurgia , Masculino , Amplitude de Movimento Articular , Tendões/cirurgia , Resultado do Tratamento
15.
J Bone Joint Surg Am ; 92(3): 700-6, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20194329

RESUMO

BACKGROUND: Porous tantalum was recently introduced as a metallic implant material for total knee arthroplasty. Its porosity, low modulus of elasticity, and high frictional characteristics were expected to provide physiologic load transfer and relative preservation of bone stock. However, to our knowledge, the effect of a Trabecular Metal tibial component on bone mineral density has not been reported. The purpose of the present study was to compare the periprosthetic bone mineral density between patients managed with uncemented Trabecular Metal and cemented tibial components. METHODS: Twenty-eight knees receiving a Trabecular Metal tibial component and twenty-eight knees receiving a cemented cobalt-chromium tibial component had dual x-ray absorptiometry scans at two weeks preoperatively and at two weeks and six, twelve, eighteen, and twenty-four months postoperatively, to assess periprosthetic bone mineral density. All of the operations were performed by one surgeon through a medial parapatellar approach. RESULTS: None of the differences between the two groups in terms of preoperative bone mineral density in the femoral neck, wrist, lumbar spine, or knee were significant. In both groups, the bone mineral density in the tibia decreased postoperatively. However, the postoperative decrease in bone mineral density in the lateral aspect of the tibia was significantly less in knees with Trabecular Metal components than in knees with cemented tibial components at twenty-four months (mean and standard deviation, -6.7% +/- 22.9% compared with -36.8% +/- 24.2%; p = 0.002). At twenty-four months postoperatively, there was no significant difference between the two groups in terms of the Knee Society score, range of motion of the knee, or bone mineral density in the lumbar spine. No prosthetic migration or periprosthetic fracture was detected in either group. CONCLUSIONS: The decrease in bone mineral density of the lateral tibial plateau was less in knees with a Trabecular Metal tibial component following total knee arthroplasty than in knees with a cemented tibial component. Additional research is needed to determine whether long-term clinical benefits are realized with the use of porous tantalum tibial components for total knee arthroplasty.


Assuntos
Artroplastia do Joelho , Densidade Óssea , Prótese do Joelho , Absorciometria de Fóton , Idoso , Cimentação , Distribuição de Qui-Quadrado , Cromo , Cobalto , Feminino , Humanos , Masculino , Porosidade , Desenho de Prótese , Estatísticas não Paramétricas , Tantálio , Tíbia/cirurgia
17.
J Biomed Mater Res B Appl Biomater ; 91(2): 799-804, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19637367

RESUMO

Reduction of wear with highly crosslinked polyethylene (HXLPE) has been reported in in vitro and in vivo studies of total hip prostheses. However, use of HXLPE in total knee prostheses is still controversial. The aim of this study was to compare in vivo polyethylene wear particle generation of HXLPE with that of conventional polyethylene in total knee prostheses of the same design. Synovial fluid was obtained from four knees with HXLPE inserts and three knees with conventional polyethylene inserts at 1 year after operation. Polyethylene particles were isolated and examined using a scanning electron microscope and image analyzer. The total number of particles in each knee was 0.28 +/- 0.12 x 10(6) in HXPLE group (mean +/- standard error) and 6.87 +/- 2.85 x 10(6) in conventional polyethylene group (p = 0.040). Particle size (equivalent circle diameter) was 0.64 +/- 0.07 microm in HXPLE group and 1.21 +/- 0.21 microm in conventional polyethylene group (p = 0.030). Particle shape (aspect ratio) was 1.33 +/- 0.10 in HXLPE and 1.88 +/- 0.19 in conventional polyethylene (p = 0.035). Thepercentage of particles of submicron size was greater than 90% in HXLPE group and 55% in conventional polyethylene group. Except for the material of the polyethylene insert, the design and material of prostheses were completely the same in both groups. The HXLPE insert generated fewer, smaller, and rounder polyethylene wear particles than the conventional polyethylene insert in the early stage after surgery.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Polietilenos/química , Idoso , Materiais Biocompatíveis , Reagentes de Ligações Cruzadas , Feminino , Humanos , Masculino , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Tamanho da Partícula , Líquido Sinovial/química
18.
Kekkaku ; 82(5): 455-8, 2007 May.
Artigo em Japonês | MEDLINE | ID: mdl-17564124

RESUMO

OBJECTIVE: The Osaka Socio-Medical Center Hospital is a medical care facility located in the Airin area of Osaka city where the prevalence of tuberculosis is high, and treats day laborers and homeless people mainly, either free of charge or with a small fee. To investigate whether this hospital can play a role to reduce the prevalence of tuberculosis in this area, we investigated the case rate of active tuberculosis in outpatients of the hospital. SUBJECTS AND METHODS: Of 1673 patients who first visited the Orthopaedic Outpatient Clinic between March 31, 2005 and June 15, 2006, 538 patients consented to undergo screening and underwent chest X-ray examination (screening group). We also analyzed chest X-ray examination in 2000 patients examined at the Department of Internal Medicine during the same period (control group). RESULTS: Of the 538 patients in the screening group (523 males and 15 females), 13 male patients (2.4%) requiring treatment were detected. Of the 2000 patients in the control group, 85 patients (84 males and 1 female) (4.3%) requiring treatment were detected. CONCLUSION: The tuberculosis case rate (2.4%) in the screening group was similar to that of tuberculosis screenings (1.1-1.8%) in the Airin area in 2004. The case rate in the control group was two times higher. Since the prevalence is very high in patients of this hospital, the hospital should play a significant role in the health care of tuberculosis patients in this community by reinforcing the screening system and enriching the outpatient clinic system.


Assuntos
Pacientes Ambulatoriais/estatística & dados numéricos , Tuberculose/epidemiologia , Tuberculose/prevenção & controle , Adulto , Idoso , Serviços de Saúde Comunitária , Feminino , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Radiografia Torácica , Fatores Socioeconômicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA